FY'26 Southslope Capital Equipment Replacements Addendum No. 1
Project Information
- Bid Title
- FY'26 Southslope Capital Equipment Replacements Addendum No. 1
- Issuing Agency
- City of Tulsa
- Location
- Oklahoma
- Published Date
- Apr 1, 2026
- Closing Date
- Apr 10, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Project Number - WPC 26-4
Project Title – FY'26 Southslope Capital Equipment Replacements
Bid Opening Date - April 10, 2026
Pre-Bid date, time, and place – Wednesday, March 25, 2026 at 10:00 a.m. SSWWTP Conference Room, 5300 S. Elwood Ave.Pre-Qualification Classification - A or D
SBE Utilization - N/AElectronic Proposal | Specification Book | Technical Specifications | Drawings | Pre-bid Attendees | Addendum No. 1
- Attachment Preview
-
DATE:April 1, 2026Ms. Cindy CanteroWater Pollution Control Section Manager175 East 2nd Street, 13th FloorTulsa, Oklahoma 74103RE: TMUA PROJECT NO. WPC 26-4, FY'26 SOUTHSLOPE CAPITAL EQUIPMENT REPLACEMENTSSUBJECT: ADDENDUM 1 - 4/1/2026Dear Ms. Cantero:This Addendum 1 consisting of nine (9) items is, hereby, made a part of the Contract Documents to thesame extent as though it were originally included, therein, and shall supersede anything contained inthe Plans and Specifications with which it might conflict. Receipt of this Addendum 1 shall be denotedin Bidder's Proposal. Failure to do so will result in the bid being deemed non-responsive.1. Pre-Bid Conference Bidder Question #1a. Question: "Will you please clarify the Basis of Award?"b. Response: Refer to the Proposal, page P-2, paragraph titled "Basis of Award."2. Pre-Bid Conference Bidder Question #2a. Question: "Are bidders required to submit two printed copies of their Proposal?"b. Response: No, submit one (1) printed hardcopy of your bid proposal forms.3. Pre-Bid Conference Bidder Question #3a. Question: "Are bidders required to submit an electronic flash drive with their Proposal?"b. Response: No, do not submit an electronic flash drive.4. Pre-Bid Conference Bidder Question #4a. Question: "What is to be done with the existing electrical conduit and box located at the scum pit?"b. Response: Remove and replace junction box and a portion of conduit run as shown in Addendum 1,revised Sheet 4 and revised Sheet 5.5. Pre-Bid Conference Bidder Question #5a. Question: "Will the existing damper on the Odor Control Piping at the scum pit need to be reinstalled?If so, this will require an additional pipe spool in order to get the attachment flange at the rightelevation."b. Response: Yes, the existing damper shall be reinstalled. Add a PVC spool pipe as shown in Addendum1, revised Sheet 5.6. Pre-Bid Conference Bidder Question #6a. Question: "The existing pressure gauges [on STP01 discharge and on STP02 discharge] are installedon isolation rings. Are the new gauges to be installed on isolation rings as well? Do you have P&IDdrawings available of this area [of Digester 3&4]?5300 S Elwood Ave, Tulsa OK 74107 | (918) 591-4482 | (918) 405-4907Page 1b. Response: Yes, install pressure gauges and switches on isolation rings to match the existingconfiguration. And, yes, Owner will provide available information regarding existing equipmentduring construction.7. Refer to SHEET 4 - ADD. ALT. #1 SCUM PIT HATCH REPLACEMENTa. Replace entire drawing with the attached drawing.b. Revise C - DEMOLITION PLAN as shown on the revised drawing.c. Add D - I/O CABLE PRESERVATION NOTES as shown on the revised drawing.8. Refer to SHEET 5 - ADD. ALT. #1 SCUM PIT HATCH REPLACEMENTa. Replace entire drawing with the attached drawing.b. Revise B - SCUM PIT HATCH PLAN as shown on the revised drawing.9. Refer to SHEET 7 - CC MAKE-UP AIR UNIT REPLACEMENTa. Replace entire drawing with the attached drawing.b. Revise B - EXISTING ROOF PLAN as shown on the revised drawing.Sincerely,Samuel H. Ray, P.E., S.E.3/31/20265300 S Elwood Ave, Tulsa OK 74107 | (918) 591-4482 | (918) 405-4907Page 2VIEW LOOKING NORTHEASTA PHOTO OF EXISTING SCUM PITREMOVE ELECTRICAL JUNCTION BOX.SEE I/O CABLE PRESERVATION NOTES.REMOVE AND PRESERVE ALLHANDRAILS. DELIVERHANDRAILS TO CITY OF TULSAFOR STORAGE. CUT OFFANCHORS FLUSH WITHCONCRETE.REMOVE AND DISPOSE OFALL METAL COVER PLATES.REMOVE HANDWHEEL, AND CUTOFF EXTENSION ROD BELOWHATCH.REMOVE FRP ODOR CONTROLGOOSENECK, AND DELIVER IT TOCITY OF TULSA FOR STORAGE.REMOVE CONDUITAS SHOWN ANDBACK TO WEST TOVERTICAL BEND.REFER TO I/O CABLEPRESERVATIONNOTES.C DEMOLITION PLAN5 5/8"±6"±10'-1"±9'-1"±8'-1 3/4"±5 5/8"±6"±INSIDE FACEOF CURBINSIDE FACEOF PIT WALLOUTSIDE FACEOF CURB1PHOAT/O4B EXISTING SCUM PIT PLAN1REMOVE FRP ODOR CONTROL DAMPER AND1. THE EXISTING CONDUIT AND ELECTRICAL180 PIPE BEND, AND PRESERVE THESEJUNCTION BOX CONTAIN AN I/O CABLECOMPONENTS FOR REINSTALLATION.THAT IS IN SERVICE AND SHALL BEPRESERVED.2. COORDINATE THE SCHEDULING OF THISREMOVE AND DISPOSE OF ALLHATCHES, PANELS AND FRAMES.WORK WITH PLANT STAFF.3. DISCONNECT CABLE FROM ITS TERMINALEND IN CABINET RIO10 IN WEST PUMPHOUSE.4. WITHDRAW CABLE FROM CONDUIT ANDJUNCTION BOX TO FACILITATE DEMOLITIONOF CONDUIT AND BOX.5. MAXIMUM TIME CABLE MAY REMAINDISCONNECTED IS TWELVE (12) HOURS INONE DAY FROM 7:00AM TO 7:00PM.6. SEE B/5 FOR CONDUIT AND JUNCTIONBOX REPLACEMENT.REMOVE AND DISPOSE OF ALLD SUPPORT FRAMING CONNECTED TO PITWALLS.I/O CABLE PRESERVATIONNOTESALL WORK ON THIS SHEET ISIN ADDITIVE ALTERNATE #1.1 ADDENDUM 1 - ISSUED 4/1/2026SHEET TITLE:ADD. ALT. #1SCUM PIT HATCH REPLACEMENTPROJECT:WPC 26-4 CAPITALEQUIPMENT REPLACEMENTSOWNER:CITY OF TULSA, OKLAHOMATULSA METROPOLITAN UTILITY AUTHORITYENGINEER:SAMUEL H. RAY, P.E.APPROVAL:____________________________________WPC SECTION MANAGERISSUE DATE:FEBRUARY 12, 2026SHEET NUMBER:4 OF 11 SHEETSBEAM CENTERLINE6061 T6 ALUMINUM WIDE FLANGEBEAM, DEPTH=6", WIDTH=6",THICKNESS=0.240", WITH (2)-1/2" DIA.STAINLESS STEEL HILTI HIT-HY 200ADHESIVE ANCHORS AT EACH ENDWITH 4 1/2" EMBEDMENT.DETAILC/5INSIDE FACEOF CURBINSIDE FACEOF PIT WALLBELOWA SCUM PIT FRAMING PLANOUTSIDE FACEOF CURBTOP OF BEAM ELEVATIONSHALL MATCH TOP OF EXISTINGCONCRETE CURB ELEVATION.HATCHES AND SAFETYGRATE SYSTEMALUMINUM WIDE FLANGE BEAM1/4"x5"x0'-10" REINFORCEDNEOPRENE BEARING PADEACH END OF BEAMTOP OF CURBOUTSIDE FACE OF CURBEXISTING CONCRETEPAVINGC SCUM PIT DETAIL12"x12" WEATHERPROOF 316STAINLESS STEEL JUNCTION BOX.CONNECT TO EXISTING BURIEDVERTICAL CONDUIT AND TO NEWHORIZONTAL CONDUIT.ADD 8" SCH. 80 PVC SPOOLPIPE TO RAISE 180 PIPE BEND1AND DAMPER UP TO FIT ONNEW HATCH.(4) HATCHES AS SHOWN WITHINTEGRAL FALL PROTECTIONSAFETY GRATE BELOW EACHHATCH, SPEC. 214.013'-9"3'-9"8" DIA. HOLE THROUGH HATCHWITH 3/4" No. 9 STAINLESS STEELEXPANDED METAL MESH MOUNTEDTO UNDERSIDE OF HATCH.1 1/2" I.D. ALUMINUM CONDUIT RUN FROMNEW JUNCTION BOX TO WEST TO VERTICALBEND. MOUNT CONDUIT AT GROUND LEVELAND WITHIN 2" OF CONCRETE CURB. PULLEXISTING I/O CABLE BACK THROUGH NEWJUNCTION BOX AND NEW CONDUIT, ANDRECONNECT TO TERMINAL BLOCK INCABINET RIO10 IN WEST PUMP HOUSE.1'-0"INSIDE FACEOF CURBINSIDE FACEOF PIT WALLBELOWB SCUM PIT HATCH PLANREINSTALL AND RECONNECTFRP ODOR CONTROL DAMPERAND 180 PIPE BEND.(1) SOLID FIXED PANEL WITH8" DIA. HOLE AT FRP ODORCONTROL FLANGE.OUTSIDE FACE OF CURBALUMINUM FRAME SET ONTOP OF EXISTING CONCRETECURB AND FASTENED WITH(8)-1/2" DIA. STAINLESS STEELHILTI HIT-HY 200 ADHESIVEANCHORS WITH 4 1/2"EMBEDMENT.SHEET TITLE:ADD. ALT. #1SCUM PIT HATCH REPLACEMENTPROJECT:WPC 26-4 CAPITALEQUIPMENT REPLACEMENTSOWNER:CITY OF TULSA, OKLAHOMATULSA METROPOLITAN UTILITY AUTHORITYENGINEER:SAMUEL H. RAY, P.E.(1) SOLID FIXED PANELALL WORK ON THIS SHEET ISIN ADDITIVE ALTERNATE #1.1 ADDENDUM 1 - ISSUED 4/1/2026APPROVAL:____________________________________WPC SECTION MANAGERISSUE DATE:FEBRUARY 12, 2026SHEET NUMBER:5 OF 11 SHEETS
- Commodity Codes
-
- NAICS 423450Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Follow Vascular Ultrasound System Active Contract Opportunity Notice ID 36C25926Q0592 Related Notice Department/Ind.
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 7/10/2026
Operating Table-OK City-36C24...
Follow Operating Table-OK City-36C24W26Q0194 Active Contract Opportunity Notice ID 36C24WQ0194 Related Notice Department/Ind.
VETERANS AFFAIRS, DEPARTMENT OF
Bid Due: 7/09/2026