RFQ 26-511 Airport Park Breakroom & Ceiling Renovation
Project Information
- Bid Title
- RFQ 26-511 Airport Park Breakroom & Ceiling Renovation
- Issuing Agency
- City of Shreveport
- Location
- Louisiana
- Published Date
- May 4, 2026
- Closing Date
- May 19, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
RFQ 26-511 Airport Park Breakroom & Ceiling RenovationBid Documents, PlansIt shall be the responder's responsibility to make inquiry as to the addenda issued. - Attachment Preview
-
SHREVEPORT PUBLIC ASSEMBLY & RECREATIONAIRPORT PARK COMMUNITY CENTERKITCHEN & LOBBY CEILING RENOVATIONS6500 KENNEDY DRIVESHREVEPORT, LOUISIANA 71109PROJECT ASSOCIATESARCHITECTRUSSELL G. DeLANCY, AIA, ARCHITECT505 TRAVIS STREET, SUITE 560SHREVEPORT, LOUISIANA 71101(318) 673-7868PROJECT LOCATION MAPSHREVEPORTREGIONALAIRPORTPROJECT SITEAIRPORT PARK COMMUNITY CENTER6500 KENNEDY DRIVESHREVEPORT, LOUISIANANORTHHOLLYWOOD AVE.W. 70TH STREETCITY OF SHREVEPORTCITY ADMINISTRATIONCITY OF SHREVEPORTTOM ARCENEAUX - MAYORTOM DARK - CHIEF ADMINISTRATIVE OFFICERCITY COUNCILTABATHA H. TAYLOR - DISTRICT AGARY BROOKS - DISTRICT BJIM TALIAFERRO - DISTRICT CGRAYSON BOUCHER - DISTRICT DDR. ALAN JACKSON, JR. - DISTRICT EJAMES GREEN - DISTRICT FURSULA BOWMAN - DISTRICT GSHREVEPORT PUBLIC ASSEMBLY & RECREATIONSHELLY RAGLE - DIRECTORDETAIL NUMBERGENERAL NOTES1. ALL WORK SHALL CONFORM WITH THE FOLLOWING CODES:- 2023 LOUISIANA STATE UNIFORM CONSTRUCTION CODE- 2021 INTERNATIONAL BUILDING CODE- 2021 INTERNATIONAL EXISTING BUILDING CODE- 2021 INTERNATIONAL MECHANICAL CODE- 2021 INTERNATIONAL PLUMBING CODE- 2021 INTERNATIONAL FUEL GAS CODE- 2015 NFPA 101 LIFE SAFETY CODE REQUIREMENTS- 2010 ADA-ABA ACCESSIBLITY GUIDELINES- 2020 NATIONAL ELECTRIC CODE2. ALL WORK SHALL CONFORM TO ALL OTHER PERTINENT CODES, REGULATIONS, LAWS ANDORDINANCES AS REQUIRED BY THE CITY OF SHREVEPORT AND THE STATE OF LOUISIANA.3. ALL PLAN DIMENSIONS INDICATED ARE TO COLUMN CENTERLINE, TO FACE OF CONCRETE,FACE OF PARTITION, OR TO FACE OF MASONRY UNLESS NOTED OTHERWISE.4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS IN THE FIELD AND, INTHE EVENT OF DISCREPANCY, REPORTING SUCH DISCREPANCY TO THE ARCHITECT, BEFORECOMMENCING WORK.5. TEMPORARY BARRICADES FOR THE PROTECTION OF PEDESTRIANS SHALL BE PROVIDED ASREQUIRED BY THE CITY OF SHREVEPORT AND/OR THE STATE OF LOUISIANA.6. DURING CONSTRUCTION PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF 2A-10B:CWITHIN A 75 FOOT TRAVEL DISTANCE OF ALL PORTIONS OF THE BUILDING ON EACH FLOOR.LOCATE AS DIRECTED BY THE LOUISIANA STATE FIRE MARSHAL.7. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIALKNOWLEDGE OR EFFORT.DRAWING SYMBOLSROOMXXXROOM NAME & ROOM NUMBERX/X.XXX/X.XXXXXEXTERIOR ELEVATION MARKSHEET NUMBERINTERIOR ELEVATION MARKPARTITION TYPEWINDOW FRAME TYPEDETAIL NUMBERX/X.XXDETAIL NUMBERXX.XXXX.XXXXDOOR NUMBERXX/X.XXSHEET NUMBERDETAIL SECTION MARKENLARGED PLAN DETAILBUILDING SECTION MARKSHEET NUMBERWALL SECTION MARKPLAN KEY NOTEABBREVIATIONS@A.F.F.ALUM.ANOD.APPROX.BD.BLDG.BLK.BM.CC.B.C.I.P.C.J.C.L.CLR.CMUCOL.CONC.DBL.DET.DIA.DIM.DN.APD.S.P.DWGS.EA.E.F.D.ELEC.EQ.EWCEXIST.EXT.F.D.C.F.D.H.C.FECFIN.FL.F.H.C.FIN.F.L.FLR.F.O.C.F.O.S.F.O.M.GA.GALV.GEN.G.I.GYP.HT.H.B.H.M.H.P.ATABOVE FINISHED FLOORALUMINUMANODIZEDAPPROXIMATELYBOARDBUILDINGBLOCKBEAMCOMPACT STALLCATCH BASINCAST IN PLACECONTROL JOINTCENTER LINECLEARCONCRETE MASONRY UNITCOLUMNCONCRETEDOUBLEDETAILDIAMETERDIMENSIONDOWNACCESSIBLE PARKINGDRY STANDPIPEDRAWINGSEACHEMERGENCY FLOOR DRAINELECTRICALEQUALELECTRIC WATER COOLEREXISTINGEXTERIORFIRE DEPT. CONNECTION (INPUT)FIRE DEPT. HOSE CONNECTION(2-1/2" & 1-1/2" OUTLETS)FIRE EXTINGUISHER CABINETFINISH FLOORFIRE HOSE CABINETFINISHEDFLOW LINEFLOORFACE OF CONCRETEFACE OF STUDFACE OF MASONRYGAUGEGALVANIZEDGENERALGALVANIZED IRONGYPSUMHEIGHTHOSE BIBBHOLLOW METALHIGHPOINTHORIZ.I.D.INT.JAN.LAV.LLH.LLV.MANUF.MAS.MAX.MECH.M.H.MIN.MISC.M.O.MTL.N.I.C.O.C.O.D.OPG.P.L.P.P.PR.R.D.REINF.REQ'DR.O.SSCHED.S.D.SECT.SHT.SIM.SPSPECS.S/SSTD.STL.STRUCT.T.C.TEL.T.O.C.T.O.S.T.S.T.W.TYP.U.N.O.W/W/OW.C.W.S.P.W.W.M.W.P.HORIZONTALINSIDE DIAMETERINTERIORJANITOR'S CLOSETLAVATORYLONG LEG HORIZONTALLONG LEG VERTICALMANUFACTURERMASONRYMAXIMUMMECHANICALMANHOLEMINIMUMMISCELLANEOUSMASONRY OPENINGMETALNOT IN CONTRACTON CENTEROUTSIDE DIAMETEROPENINGPROPERTY LINEPOWER POLEPERIMETERROOF DRAINREINFORCED (ING)REQUIREDROUGH OPENINGSTALL WIDTHSCHEDULESTORM DRAINSECTIONSHEETSIMILARSPRINKLER RISERSPECIFICATIONSSERVICE SINKSTANDARDSTEELSTRUCTURALTOP OF CURBTELEPHONETOP OF CONCRETETOP OF STEELTOP OF SPANDRELTOP OF WALK, WALLTYPICALUNLESS NOTED OTHERWISEWITHWITHOUTWATER CLOSETWET STANDPIPEWELDED WIRE MESHWATERPROOFDRAWING INDEXCOVER SHEETA1.01 DEMOLITION PLANA2.01 FLOOR PLANA2.02 REFLECTED CEILING PLANA3.01 INTERIOR ELEVATIONS / MILLWORK SECTIONSAPRIL 21, 2026CITY OF SHREVEPORTREVISIONS:GENERAL DEMOLITION NOTES1. ALL DEMOLITION WORK WILL BE PERFORMED IN A SAFE AND ORDERLY MANNER.2. ALL DEBRIS SHALL BE PROPERLY AND LEGALLY HAULED AND DISPOSED.3. DEMOLITION CONTRACTOR WILL BE RESPONSIBLE FOR ALL FEES, APPLICATIONSAND LICENSES ASSOCIATED WITH DEMOLITION AND DISPOSAL.4. OWNER SHALL MAINTAIN FIRST RIGHT OF REFUSAL ON ALL REMOVED ITEMS.5. ALL DEMOLITION WORK SHALL BE COORDINATED WITH NEW WORK AND SHALLINCLUDE ALL NECESSARY PENETRATIONS IN WALLS AND FLOOR SLABS ASSOCIATEDWITH NEW SCOPE.6. DURING DEMOLITION ACTIVITY, EXTREME CARE SHALL BE TAKE NOT TO DAMAGEEXISTING FEATURES THAT ARE TO REMAIN INPLACE. ANY DAMAGE TO EXISTINGFEATURES INTENED TO REMAIN SHALL BE REPAIRED/REPLACED TO THE SATISFACTIONOF THE OWNER AT THE CONTRACTOR'S EXPENSE.7. ALL DEMOLITION ACTIVITY SHALL BE COORDINATED AND SCHEDULED WITH THEBUILDING OWNER.8. ALL DOORS AND FRAMES IDENTIFIED TO BE REMOVED SHALL BE SALVAGED FOR REUSE.THIS SCOPE SHALL ALSO INCLUDE THE SALVAGE OF ALL HARDWARE.9. CONTRACTOR SHOULD BE AWARE OF LOAD BEARING WALL DURING DEMOLITIONACTIVITIES. PROPER BRACING SHOULD BE USED TO INSURE STRUCTURAL INTEGRITY.DEMOLITION PLAN NOTESD1 REMOVE EXISTING CEILING PANELS AND GRID. PREP AREA TO RECEIVE NEW GRID AND ACOUSTIC CEILING PANELS.D2 REMOVE VERTICAL PORTION OF ACOUSTIC CEILING PANELS. PREP AREA TO CONSTRUCT NEW DRYWALL BULKHEAD.D3 REMOVE EXISTING LIGHT FIXTURES SHOWN DASHED. PREP TO RECEIVE NEW FIXTURE. SEE REFLECTED CEILING PLAN.D4 REMOVE EXISTING HVAC SUPPLY AIR GRILLS SHOWN DASHED. PREP DUCT TO RECEIVE NEW GRILL.D5 REMOVE EXISTING HVAC RETURN AIR FILTER GRILLS SHOWN DASHED. PREP DUCT TO RECEIVE NEW RETURN AIR FILTER GRILL.D6 SALVAGE EXISTING CEILING MOUNTED SPEAKERS FOR REINSTALLATION.D7 EXISTING SLOT DIFFUSER TO REMAIN. CLEAN.D8 REMOVE EXISTING EXIT LIGHT SHOWN DASHED. PREP TO RECEIVE NEW EXIT FIXTURE.D9 REMOVE EXISTING MILLWORK.EXISTING VENT HOOD TO REMAIN. PROTECT FROM DEMOLITION SCOPE.REMOVE EXISTING STAINLESS STEEL SINK & FAUCET. PREP PLUMBING TO RECEIVE NEW SCHEDULED SINK & FAUCET.REMOVE EXISTING ELECTRIC RANGE.PARTITION LEGENDEXISTING PARTITION TO REMAINEXISTING PARTITION TO BE REMOVEDNEW PARTITION (SHOWN ON FLOOR PLAN)DEMOLITION PLANSCALE: 1/8" = 1'-0"APRIL 21, 202622GAMES11031CORRIDOR21021LOBBY10126GALLEY1043742/A3.01 985CITY OF SHREVEPORTREVISIONS:FLOOR PLAN GENERAL NOTES1. ONLY AREAS THAT HAVE RECEIVED ROOM NAMES & NUMBERS ARE IN THE SCOPE OF WORK. ALL OTHER AREAS ARE N.I.C.2. REFER TO SHEET A1.01 FOR DEMOLITION SCOPE.3. REFER TO SHEET A2.02 FOR REFLECTED CEILING PLAN.PARTITION LEGENDEXISTING PARTITION TO REMAINEXISTING PARTITION TO BE REMOVED (SHOWN OF DEMOLITION PLAN)NEW PARTITION NON-FIRE RATEDFLOOR PLAN KEY NOTESPREP AREA TO RECEIVE NEW ACOUSTIC LAY-IN CEILING PANELS AND GRID. SEE REFLECTED CEILING PLAN FOR SCOPE.DRYWALL BULKHEAD SHOWN DASHED. SEE REFLECTED CEILING PLAN.EXISTING ICE MACHINE TO REMAIN. REMOVE FROM KITCHEN AREA AND REINSTALL AT COMPLETION OF WORK.NEW REFRIGERATOR EQUAL TO GE MODEL GTS22KYNRFS. VERIFY POWER.NEW KITCHEN SINK EQUAL TO ELKAY STAINLESS STEEL SINK MODEL LGR4322C. PROVIDE WITH DRAINS AND FAUCET SETEQUAL TO ELKAY LK3001CR. PROVIDE ALL NECESSARY PLUMBING WORK.EXISTING VENT HOOD TO REMAIN IN PLACE.NEW ELECTRIC SLIDE-IN RANGE EQUAL TO GE MODEL GR5500PVSS. VERIFY POWER.NEW MILLWORK. PAINTED FRONTS W/ PLASTIC LAMINATE TOP & FULL BACKSPLASH.PROVIDE COOKING RESTRICTION SIGNAGE IN BREAK ROOM. SEE 12/A3.01GENERAL FINISH NOTES1. NEW DRYWALL BULKHEADS SHALL HAVE AN ORANGE PEEL TEXTURE, PAINTED TO MATCH THE ADJACENT EXISTING WALL.2. NEW CEILING PANEL SHALL EQUAL TO ARMSTRONG SCHOOL ZONE FINE FISSURED #1713, 24" X 24" SQUARE EDGE. COLOR: WHITE.3. NEW CEILING GRID SHALL EQUAL TO ARMSTRONG PRELUDE XL 15/16" EXPOSED TEE GRID SYSTEM. COLOR: WHITE.4. THE NEW MILLWORK FRONTS, DOORS AND DRAWERS ARE TO BE PAINTED SEMI-GLOSS, COLOR TO BE SELECTED BY OWNER.5. THE NEW MILLWORK COUNTER TOP & BACKSPLASH SHALL BE PLASTIC LAMINATE EQUAL TO WILSONART. COLOR AND TEXTURE TO BE SELECTED BY OWNER.FLOOR PLANSCALE: 1/8" = 1'-0"APRIL 21, 2026C1C2C8C48"C36"C5C3C3 C5C4C7C6C7CITY OF SHREVEPORTREVISIONS:CEILING LEGENDNEW 2 X 4 LED LAY-IN LIGHT FIXTURE EQUAL TOLITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENSNEW 2 X 4 LED LAY-IN LIGHT FIXTURE EQUAL TOLITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENS, 90 MINUTE EMERGENCY BATTERY PACKNEW 2 X 2 LED LAY-IN LIGHT FIXTURE EQUAL TOLITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENSNEW 2 X 2 LED LAY-IN LIGHT FIXTURE EQUAL TOLITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENS, 90 MINUTE EMERGENCY BATTERY PACK.NEW EXIT LIGHT EQUAL TO LITHONIA LIGHTING, LQM, RED LETTERS, WHITE HOUSING, BATTERY BACK-UP.REINSTALLED EXISTING SPEAKER. CLEAN SPEAKER BEFORE REINSTALLATION.NEW 24 X 24 SUPPLY AIR CEILING DIFFUSER EQUAL TO TITUS TMS, FULL FACE LAY-IN MOUNTNEW 24 X 24 RETURN AIR CEILING FILTER GRILL EQUAL TO TITUS 350RF, LAY-IN T BAR MOUNT, 1" FILTER.REINSTALLED EXISTING SLOT DIFFUSER. CLEAN DIFFURSER BEFORE REINSTALLATION.C2C1GENERAL CEILING NOTES1. WORK IS ONLY SCHEDULED IN ROOMS THAT HAVE RECIEVED ROOM NAMES AND NUMBERS ON THE FLOOR PLAN. ALL OTHER AREAS ARE N.I.C.2. PROVIDE NEW CEILING GRID COMPATIBLE WITH SCHEDULED CEILING PANELS. COLOR: WHITE.3. COORDINATE ALL OTHER TRADES WITH CEILING WORK TO MINIMIZE DAMAGING EXPOSURE TO OTHER WORK.4. WHERE APPLICABLE, SUPPORT LIGHT FIXTURE WITH HANGER WIRE AT EACH CORNER.5. PROVIDE 1 BOX OF ATTIC STOCK OF EACH TYPE OF CEILING PANEL.7. INSTALL NEW SUSPENDED CEILING AT THE ORIGINAL CEILING HEIGHT. FIELD VERIFY.REFLECTED CEILING PLAN NOTESNEW CEILING INSTALLED AT 14'-0"NEW CEILING INSTALLED AT 10'-0"NEW CEILING INSTALLED AT 8'-0"NEW HVAC SUPPLY REGISTER. PROVIDE ALL NECESSARY DUCT WORK FOR PROPER INSTALLATION.NEW LIGHT FIXTURE. PROVIDE ALL NECESSARY WIRING AND SUPPORTS FOR PROPER INSTALLATION.EXISTING VENT HOOD TO REMAIN. CLEAN.NEW DRYWALL FURR-DOWN.NEW HVAC RETURN AIR GRILL. PROVIDE ALL NECESSARY DUCT WORK FOR PROPER INSTALLATION.REFLECTED CEILING PLANSCALE: 1/8" = 1'-0"APRIL 21, 20261'-7 1/2"7/A3.108'-2"4'-0"EXISTING VENT HOOD TO REMAIN1'-2"2'-6 1/2"DRYWALL FURRDOWN5/A3.01COOKING RESTRICTIONSIGNAGESEE 12/A3.011'-2"9'-8"3'-2 1/2"3'-3"7/A3.013'-2 1/2"1'-2"DRYWALL FURRDOWN1'-2"2'-4"7/A3.018'-2"5'-10"8/A3.01DRYWALL FURRDOWN5/A3.014/A3.01STAINLESS STEEL SINK5/A3.01CITY OF SHREVEPORTREVISIONS:2'-4 1/2"2'-6"NEW WALL BASEEXISTING DOOR & FRAMEINTERIOR ELEVATIONSCALE: 1/2" = 1'-0"2'-0"PLAS LAM CLAD3/4" WATER RESISTANT PLYWOOD COUNTER TOP& SPLASHSCHEDULED SINK2'-5 1/2"CABINET PULLSAPPLIANCE BY OWNERFULL HEIGHT BACK SPLASH2'-0"PLAS LAM CLAD3/4" MDF COUNTER TOP & SPLASHFULL HEIGHT BACK SPLASH8'-0"ADJUSTABLE SHELFINTERIOR ELEVATIONSCALE: 1/2" = 1'-0"2'-0"PLAS LAM CLAD3/4" MDF COUNTER TOP & SPLASHPAINTED1/4" MDF BACKPAINTED3/4" MDF BOTTOM3/4"FALSE DRAWERFRONTPAINTED3/4" MDF DOOR1/2" DRAWER BOXW/ 1/4" PLYWOOD BOTTOMPAINTED1/4" MDF BACKPAINTED3/4" MDF ADJ SHELFPAINTED3/4" MDF BOTTOM3/4"PAINTED3/4" MDF DOORCOORDINATE ELECTRICALREQUIREMENTSSCHEDULED APPLIANCE3"3"USE WATER RESISTANT PLYWOODAT SINK COUNTER TOPMILLWORK SECTIONSCALE: 1 1/2" = 1'-0"MILLWORK SECTIONSCALE: 1 1/2" = 1'-0"MILLWORK SECTIONSCALE: 1 1/2" = 1'-0"1'-6"FULL HEIGHT BACK SPLASH5'-10"APPLIANCE BY OWNERINTERIOR ELEVATIONSCALE: 1/2" = 1'-0"NEW WALL BASEEXISTING ICE MAKEREXISTING DOOR & FRAMEDRYWALL FURRDOWNPAINTED1/4" MDF BACK ON1X WOOD CLEATSPAINTED3/4" MDF DOORPAINTEDINTERIOR1'-2"PAINTED3/4" MDF ADJ SHELVESDRYWALL FURRDOWNPAINTED3/4" MDF DOORPAINTED1/4" MDF BACK ON1X WOOD CLEATSPAINTED3/4" MDF ADJ SHELVESPAINTEDINTERIOR1'-2"SCHEDULED APPLIANCEPAINTED1/4" MDF BACK ON1X WOOD CLEATSPAINTED3/4" MDF DOORPAINTEDINTERIOR1'-2"VENT HOODMILLWORK SECTIONSCALE: 1 1/2" = 1'-0"MILLWORK SECTIONSCALE: 1 1/2" = 1'-0"MILLWORK SECTIONSCALE: 1 1/2" = 1'-0"SCHEDULED ACOUSTIC CEILINGWOOD STUD FRAMINGSECURED TO STRUCTURE2X HEADER4 3/4"ALIGN EDGE ANGLE TRIMWITH DRYWALLSCHEDULED ACOUSTIC CEILINGCEILING DETAILSCALE: 1 1/2" = 1'-0"SCHEDULED ACOUSTIC CEILINGWOOD STUD FRAMING2X HEADER4 3/4"ALIGN EDGE ANGLE TRIMWITH DRYWALLLINE OF EXISTING PARTITIONCEILING DETAILSCALE: 1 1/2" = 1'-0"SIGNAGE MUST DISPLAY:RAISED CHARACTER VERBALDESCRIPTIONPROVIDE SIGNAGE W/ LIGHT COLOREDCHARACTERS/TEXT & DARK BACKGROUNDARCHITECT TO SELECT COLORS9"BY ORDER OF THESTATE FIRE MARSHALCOOKING SHALL NOTPRODUCE ANYGREASE LADEN VAPORSSIGNAGESCALE: 3" = 1'-0"APRIL 21, 2026
- Commodity Codes
-
- NAICS 236118Residential Remodelers
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Bid Number Description Date Issued Bid Open Date/Time 50017-D2600050 Window Replacements Non-Mandatory Pre-Bid
State Government of Louisiana
Bid Due: 7/08/2026
Re-Bid #0004 Chiller Replacement
Bid Number Description Date Issued Bid Open Date/Time 50014-0004 Re-Bid #0004 Chiller Replacement
State Government of Louisiana
Bid Due: 7/22/2026