IFB 25-081 Shreveport City Jail Generator Replacement
Project Information
- Bid Title
- IFB 25-081 Shreveport City Jail Generator Replacement
- Issuing Agency
- City of Shreveport
- Location
- Louisiana
- Published Date
- Dec 2, 2025
- Closing Date
- Jan 8, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
IFB 25-081 Shreveport City Jail Generator ReplacementIt shall be the responder's responsibility to make inquiry as to the addenda issued. - Attachment Preview
-
GENERATOR REPLACEMENTSHREVEPORT JAILCITY OF SHREVEPORTSHREVEPORT, LOUISIANASHEET INDEXED1.1ED1.2EP1.1EP7.1EP8.1ELECTRICALELECTRICAL DEMOLITION FLOOR PLAN - WESTELECTRICAL DEMOLITION FLOOR PLAN - EASTELECTRICAL FLOOR PLAN - WESTELECTRICAL DETAILS, NOTES, & SYMBOLSELECTRICAL DETAILS, RISER DIAGRAM, & PANEL SCHEDULESEMA Engineering & Consulting, Inc.Tyler | Austin | Houston | El PasoDFW | San Antonio | ShreveportTexas Firm Registration No. F-893Louisiana Firm Registration No. EF-5818www.EMAengineer.comREVIEW ONLYNOT FOR REGULATORYAPPROVAL, PERMITTING,OR CONSTRUCTIONEngineer: James M. Tate IIILicense State: TX License No.: 10286423710-24-2025 4/1/2024 10:52:47 AMDate:ISSUE DATEOCT. 24, 2025ISSUE STATUSDATESHREVEPORTLOCATION MAPNORTHKEY PLANEMA JOB #: 5-001-1898-006DRAWN BY:MSACHECKED:CMCCOVER PAGESHEET NUMBERCOVER SUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THECONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTINGAND NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE ANDWORKING SYSTEM.J ED13H2MECH. / ELEC.L2ED4 ED3CONTROLBOOKING DESKOFFICE 1ED5OFFICE 2ED5RELEASEOFFICE 3ED5OFFICE JAIL COMNDRED6ED5J ED9EXISTING PANEL EHDPEXISTING ATS ED2EXISTING PANEL MHDPMECH./ ELEC.ED1EXISTING EMERGENCY GENERATOR1ELECTRICAL DEMOLITION FLOOR PLAN - WEST1/8"=1'-0"CU-3ED7EL1ET1 ED12EH1 ED10ED8AHU-3L1T1MECH./ ELEC.H1ELECTRICAL GENERAL NOTES1. SEE SHEET EP7.1 FOR GENERAL NOTES APPLICABLE TO THE ENTIRE DRAWING SET.ELECTRICAL DEMOLITION PLAN NOTESEMA Engineering & Consulting, Inc.Tyler | Austin | Houston | El PasoDFW | San Antonio | ShreveportTexas Firm Registration No. F-893ED1EXISTING GENERATOR TO BE REMOVED AND REPLACE. REMOVE EXISTING CONDUIT AND WIRING BACK TLoOuisiana Firm Registration No. EF-5818SOURCE.www.EMAengineer.comED2 EXISTING ATS TO BE REMOVED. REMOVE EXISTING CONDUIT AND WIRING BACK TO SOURCE.ED3 EXISTING LIGHTING TO REMAIN IN PLACE AND OPERATIONAL.REVIEW ONLYED4 EXISTING RECEPTACLES IN THIS ROOM TO BE REMOVED. EXISTING CONDUIT AND WIRING TO REMAIN ANDANPOPTRFOOVRALR, EPGEURLMAITTTOIRNYG,BE REUSED TO PROVIDE POWER TO NEW RECEPTACLES.OR CONSTRUCTIONED5EXISTING RECEPTACLES IN THIS ROOM TO BE REMOVED. REMOVE EXISTING CONDUIT AND WIRING BACKTO SOURCE.Engineer: James M. Tate III10-24-2025 ED6EXISTING LIGHT FIXTURES TO REMAIN IN ROOMS 242, 243, 244, AND 245. REMOVE EXISTING CONDUIT ANDLicense State: TX License No.: 108264327WIRING BACK TO NEAREST JUNCTION POINT SERVING THESE ROOMS. EXISTING CIRCUIT TO REMAIN FOR4/1/2024 10:52:47 AMOTHER AREAS.Date:ED7REMOVE EXISTING CIRCUIT SERVING CONDENSER UNIT FROM EXISTING PANEL 'H1'. REMOVE CONDUITAND WIRING BACK TO SOURCE. TURN BREAKER OFF AND MARK AS 'SPARE'.ISSUE DATEOCT. 24, 2025 ED8REMOVE EXISTING CIRCUIT SERVING AIR HANDLER UNIT FROM EXISTING PANEL 'H1'. REMOVE CONDUITAND WIRING BACK TO SOURCE. TURN BREAKER OFF AND MARK AS 'SPARE'.ISSUE STATUSDATEED9REMOVE EXISTING CIRCUIT SERVING FACP FROM EXISTING PANEL 'L2'. REMOVE CONDUIT AND WIRINGBACK TO SOURCE. TURN BREAKER OFF AND MARK AS 'SPARE'.DISCONNECT AND REMOVE EXISTING UPSTREAM CONDUIT AND FEEDER BACK TO SOURCE FOR PANELED10 'EH1'. TURN EXISTING UPSTREAM BREAKER OFF AND MARK AS 'SPARE'.ED12DISCONNECT AND REMOVE EXISTING UPSTREAM CONDUIT AND FEEDER BACK TO SOURCE FORTRANSFORMER 'ET1' THAT IS FEEDING PANEL 'EL1'. TURN EXISTING UPSTREAM BREAKER OFF ANDMARKAS 'SPARE'.ED13 EXISTING FULL BODY SCANNER TO REMAIN IN PLACE AND OPERATIONAL.NO ELECTRICAL SCOPE IN THIS AREAKEY PLANEMA JOB #: 5-001-1898-006DRAWN BY:MSACHECKED:CMCELECTRICAL DEMOLITIONFLOOR PLAN - WESTSHEET NUMBERSUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THECONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTINGAND NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE ANDWORKING SYSTEM.ED1.1214821482148KL1214821482148KT1KH1 MECH. / ELEC.EL2ET2 ED15EH2 ED11ELECTRICAL GENERAL NOTES1. SEE SHEET EP7.1 FOR GENERAL NOTES APPLICABLE TO THE ENTIRE DRAWING SET.ELECTRICAL DEMOLITION PLAN NOTESED3 EXISTING LIGHTING TO REMAIN IN PLACE AND OPERATIONAL.EMA Engineering & Consulting, Inc.Tyler | Austin | Houston | El PasoDFW | San Antonio | ShreveportTexas Firm Registration No. F-893Louisiana Firm Registration No. EF-5818www.EMAengineer.comED11DISCONNECT AND REMOVE EXISTING UPSTREAM CONDUIT AND FEEDER'EH2'. TURN EXISTING UPSTREAM BREAKER OFF AND MARK AS 'SPARE'.BACKTO SOURCE FORPANELED14 EXISTING RECEPTACLES IN THIS ROOM TO REMAIN IN PLACE AND OPERATIONAL.REVIEW ONLYED15DISCONNECT AND REMOVE EXISTING UPSTREAM CONDUIT AND FEEDER BACK TO SOURCE FORTRANSFORMER 'ET2' THAT IS FEEDING PANEL 'EL2'. TURN EXISTING UPSTREAM BREAKER OFF AND MARKNOT FOR REGULATORYAPPROVAL, PERMITTING,OR CONSTRUCTIONAS 'SPARE'.Engineer: James M. Tate IIILicense State: TX License No.: 10284632710-24-2025 4/1/2024 10:52:47 AMDate:ISSUE DATEOCT. 24, 2025ISSUE STATUSDATECONTROL 2ED14ED3NO ELECTRICAL SCOPE IN THIS AREA1MEP FLOOR PLAN TEMPLATE1/8"=1'-0"KEY PLANEMA JOB #: 5-001-1898-006DRAWN BY:MSACHECKED:CMCELECTRICAL DEMOLITIONFLOOR PLAN - EASTSHEET NUMBERSUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THECONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTINGAND NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE ANDWORKING SYSTEM.ED1.2H2MECH. / ELEC.L2E13JE1CONTROLE1BOOKING DESKOFFICE 1EL3-3EL3-1OFFICE 2RELEASEOFFICE 3EL3-7EL3-5OFFICE JAIL COMNDREL3-2EL3-4EL3-9E10 EL3-10EL3-11EL3-8EL3-17J E2E6 E11 E12EXISTING PANEL EHDPNEW ATS-S E8EXISTING PANEL MHDP E9MECH./ ELEC.E8E14NEW ATS-1 EL3-16E7NEW GENERATOREXISTING EMERGENCY GENERATOR1ELECTRICAL FLOOR PLAN - WEST1/8"=1'-0"EL3TXEL3CU-3E3E4EL1ET1MECH./ ELEC.EH1 E5AHU-3L1T1H1ELECTRICAL GENERAL NOTES1. SEE SHEET EP7.1 FOR GENERAL NOTES APPLICABLE TO THE ENTIRE DRAWING SET.ELECTRICAL PLAN NOTESEMA Engineering & Consulting, Inc.Tyler | Austin | Houston | El PasoDFW | San Antonio | ShreveportTexas Firm Registration No. F-893E1 PROVIDE POWER TO NEW RECEPTACLES IN THIS ROOM FROM EXISTING CIRCUIT IN PANEL 'EL' THAT Louisiana Firm Registration No. EF-5818PREVIOUSLY SERVED REMOVED RECEPTACLES. EXTEND ELECTRICAL CONDUIT AND WIRE AS REQUIRED.pwww.EMAengineer.comE2PROVIDE BATTERY PACK FOR FIRE ALARM CONTROL PANEL AS REQUIRED FOR LIFE SAFETY. EXTENDELECTRICAL CONDUIT AND WIRE AS REQUIRED.REVIEW ONLY PROVIDE POWER TO EXISTING CONDENSER FROM EXISTING PANEL 'EHDP'. PROVIDE 80A 3P BREAKER. USEE3 #3 WIRE. REUSE EXISTING DISCONNECT AND FUSES. EXTEND ELECTRICAL CONDUIT AND WIRE ASNOT FOR REGULATORYREQUIRED.APPROVAL, PERMITTING,OR CONSTRUCTIONE4PROVIDE POWER TO EXISTING AIR HANDLER UNIT FROM EXISTING PANEL 'EHDP'. PROVIDE 80A 3PBREAKER. USE #3 WIRE. REUSE EXISTING DISCONNECT AND FUSES. EXTEND ELECTRICAL CONDUIT ANDEngineer: James M. Tate IIIWIRE AS REQUIRED.License State: TX License No.: 102846237E5 PROVIDE NEW 60A 3P BREAKER IN EXISTING PANEL 'EH1' TO FEED PANEL 'EH2'. SEE RISER DIAGRAM FORMORE INFORMATION.Date:10-24-2025 4/1/2024 10:52:47 AME6PROVIDE NEW 50A 3P BREAKER, AND 30A 3P BREAKER IN EXISTING PANEL 'EHDP' TO FEED EXISTINGTRANSFORMER 'ET1' AND TRANSFORMER 'ET2' RESPECTIVELY. SEE RISER DIAGRAM FOR MOREINFORMATION.E7 NEW GENERATOR TO BE INSTALLED IN THIS LOCATION. SEE SHEET EP7.1 FOR MORE INFORMATION.E8 NEW ATS TO BE INSTALLED IN THIS LOCATION. SEE RISER DIAGRAM FOR MORE INFORMATION.ISSUE DATEOCT. 24, 2025ISSUE STATUSDATEE9PROVIDE NEW 100A 3P BREAKER FOR LIFE SAFETY PANEL'S ATS-S IN EXISTING PANEL 'MHDP'. ATS-SFEEDS PANEL 'EH1'. UTILIZE AVAILABLE BREAKER SPACES.E10PROVIDE NEW LIGHTING CIRCUIT TO SERVE EXISTING LIGHT FIXTURESA245 FROM PANEL 'EH1'. PROVIDE 20A 1P BREAKER WITH #12 WIRE.INROOMSA216,A243,A244,ANDE11PROVIDE NEW 30A 3P BREAKER IN EXISTING PANEL 'EHDP' TO FEED NEW TRANSFORMERAVAILABLE BREAKER SPACES. SEE RISER DIAGRAM FOR MORE INFORMATION.'TXEL3'.UTILIZEE12 REUSE EXISTING 225A 3P BREAKER IN EXISTING PANEL 'MHDP' TO FEED NEW ATS-1. SEE RISER DIAGRAMFOR MORE INFORMATION.E13 EXISTING FULL BODY SCANNER TO REMAIN IN PLACE AND OPERATIONAL.E14 WEATHERPROOF GFCI MAINTENANCE OUTLET INSTALLED 18" A.F.F.NO ELECTRICAL SCOPE IN THIS AREAKEY PLANEMA JOB #: 5-001-1898-006DRAWN BY:MSACHECKED:CMCELECTRICAL FLOOR PLAN- WESTSHEET NUMBERSUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THECONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTINGAND NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE ANDWORKING SYSTEM.EP1.1GENERATOR INFOSIZE (kW) - 200kWVOLTAGE (V) - 480vPHASE (ph) - 3PRI. BREAKER (A) - 225ASEC. BKR (A) - 100AATS INFO SUPPORT EQUIP CTKSATS-1 SIZE (Amps) - 300A 120V GFCI Maint Outlet - EL3-16ATS-S SIZE (Amps) - 100A 120V Battery Charger - EL3-14w/ Maintenance Bypass - N120v Block Heater - EL3-12Service Entrance Rated - NPROVIDE 1"CONDUITS FROMSERVING PANEL TOSUPPORTEQUIPMENT LISTEDIN THIS DETAIL.Provide Signage at the service entrance equipment indicating"Emergency Power Source via Generator" per NEC 700.7Slab around generatorto extend 3' beyondgenerator dimensionsfor access.Slab - consultstructural engineer forrequirements.Prime MoverDIMENSIONS:LENGTH -234inWIDTH - 54inHEIGHT - 111inGensetMainBreaker(s)48 Hr Diesel Belly TankSEE DRAWINGS FORGENERATOR ATSLOCATIONCOORDINATE EXACTLOCATION OF REMOTEANNUNCIATOR PANELWITH OWNERATSNEMA 3RALL FEEDERSPER RISERDIAGRAM1" C. TOGENSETGENERATOR PAD TO BE 3' LARGER THANGENERATOR DIMENSIONS ALL THE WAY AROUNDFOR ACCESS AND MAINTENANCE.TO PARENT PANEL OR TXTO DOWNSTREAMPANEL OR LOAD1GENERATOR INFORMATIONN.T.S.BC2277/480V, 3PH, 4WFed from MDPA/C # B105208V, 3PHCircuit BAC-15PANELBOARD LABEL (TYPICAL)HVAC DISCONNECT SWITCH LABEL (TYPICAL)NOTES:1. ATTACH SECURELY WITH NON-CORRODING STAINLESS STEEL SCREWS, NON-CORRODING POP RIVETSARE ACCEPTABLE, ADHESIVE ATTACHMENT IS NOT ACCEPTABLE.2. LABEL ALL PANELBOARDS, SWITCHBOARDS, TRANSFORMERS, HVAC DISCONNECT SWITCHES, ANDMOTOR CONTROL CENTERS AS REQUIRED, REFERENCE SPECIFICATION SECTION 260553.2ELECTRICAL EQUIPMENT IDENTIFICATIONN.T.S.WALLROOF3" MIN.12" MAX.JOISTROOFCEILINGROUTE CONDUIT IN WALL UP ASHIGH AS POSSIBLE. DO NOT RUNCONDUIT EXPOSED ON WALL.ROUTE CONDUIT IN EXPOSED AREASPERPENDICULAR OR PARALLEL TO WALLS.ROUTE CONDUIT AS HIGH AS POSSIBLEAND ROUTE CONDUIT RUNS ADJACENT TOEACH OTHER. CONDUIT SHALL BEORDERLY AND NEAT.3EXPOSED CONDUIT ROUTINGN.T.S.NEVER SUPPORT CONDUITS FROM BOTTOM CHORD OF JOIST.USE WHERE ATTIC SPACE ISGREATER THAN 3'-0"ATTACH TO TOP CHORD OFSTRUCTURE AS REQUIREDWITH BEAM CLAMPSCHANNEL PIPESTRAPS OR CLIPS1/4" CONTINUOUSTHREADED RODCONDUIT(S) AS REQUIREDGALVANIZED CHANNEL - 1 5/8" X 1 5/8"X 12 GAUGE SPACED AS DIRECTEDFINISHED CEILING ASSCHEDULED4CONDUIT SUPPORTN.T.S.2"3M FIRE BARRIER FS-195+WRAP/STRIP. (FOR FIRERATED WALL PENETRATIONSOR EXTERIOR WALLS)CONDUIT3M FIRE BARRIER RC-1 RESTRICTINGCOLLAR OR PPD. (FOR FIRE RATEDWALL PENETRATIONS OR EXTERIORWALLS)WALL - SEE ARCHITECTURAL FORCONSTRUCTION TYPE2"GALVANIZEDSTEEL SLEEVECONDUITFILL PER SPECIFICATIONAND NEC5WALL PENETRATIONN.T.S.3"2"3"MIN MIN MINGRADE PER NEC 300.5(D)(3)WARNING TAPEEARTH FILLCONCRETE ENCASEMENT FORPRIMARY AND SECONDARY FEEDERS.SAND BACKFILL/IMBEDMENT FOR ALLOTHER FEEDERSCONDUIT (QUANTITY VARIES)12" MAX PER NEC 300.5(A) or24" MIN. UTILITY REQUIREMENTS,WHICHEVER IS GREATER.3" MINSUPPORT CONDUITPER NEC 352.30B4" MINPLASTIC SPACE SUPPORTSSEE SPECIFICATION SECTION 26 20 00 PART 3 & 26 05 33 FOR MORE INFORMATION.6UNDERGROUND CONDUITSN.T.S.ELECTRICAL GENERAL NOTES1. BRANCH CIRCUIT - PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH CIRCUIT. MULTIPLECIRCUITS SHALL NOT SHARE A COMMON NEUTRAL. NEUTRAL CONDUCTORS SHALL BE SIZED AS LARGEAS THE PHASE CONDUCTORS. NEUTRAL CONDUCTORS SHALL NOT BE OF A REDUCED SIZE.2. CONDUIT - WHERE POSSIBLE, ALL CONDUIT AND/OR CABLING SHALL BE INSTALLED BETWEEN THEBOTTOM AND TOP CHORD OF JOIST. WHERE NO CEILINGS ARE SCHEDULED, ALL CONDUIT SHALL BE UPAGAINST BOTTOM OF THE TOP CHORD. DO NOT SUPPORT OR REST CONDUITS ON BOTTOM CHORD OFTHE JOISTS.3. CONDUIT - ROUTE CONDUIT IN EXPOSED AREAS PERPENDICULAR OR PARALLEL TO WALLS. ROUTECONDUIT AS HIGH AS POSSIBLE AND ROUTE CONDUIT RUNS ADJACENT TO EACH OTHER. CONDUITSSHALL BE ORDERLY AND NEAT.4. EQUIPMENT - DURING THE SUBMITTAL PHASE, THIS CONTRACTOR SHALL SUBMIT LAYOUT OF ALLPANELS, SWITCHGEAR, TRANSFORMERS, CONTACTORS, ETC. IN EACH EQUIPMENT ROOM WHERE THISEQUIPMENT IS LOCATED. ALL LAYOUTS MUST BE DRAWN TO SCALE AND DIMENSIONED.ELECTRICAL DEMOLITION GENERAL NOTES1. UNLESS NOTED ON DRAWINGS, ALL LIGHTING, SWITCHES, OUTLETS AND OTHER ELECTRICAL DEVICESARE TO REMAIN.2. REFER TO SPECIFICATION SECTION 26 05 05, ELECTRICAL DEMOLITION REMODELING, FOR GENERALDEMOLITION REQUIREMENTS.3. ALL MATERIAL REMOVED AND NOT RETAINED BY THE OWNER SHALL BE DISPOSED OF OFF SITE IN ALAWFUL MANNER.EMA Engineering & Consulting, Inc.Tyler | Austin | Houston | El PasoDFW | San Antonio | ShreveportTexas Firm Registration No. F-893Louisiana Firm Registration No. EF-5818www.EMAengineer.comREVIEW ONLYNOT FOR REGULATORYAPPROVAL, PERMITTING,OR CONSTRUCTIONEngineer:License State: TX License No.: 10863710-24-2025 4/1/2024 10:52:47 AMDate:ISSUE DATEOCT. 24, 2025ISSUE STATUSDATESYMBOLDESCRIPTIONBRANCH CIRCUIT - CONDUIT IN WALL or ABOVE CEILING, INDICATES DEVICES AND EQUIPMENT ON A CIRCUIT.NOT INTENDED TO SHOW ROUTINGBRANCH CIRCUIT OR FEEDER CONDUIT UNDER FLOOR or UNDERGROUNDCL-1,3,5SWITCH WIRE - SWITCH CIRCUITARROW INDICATES HOMERUN, TEXT INDICATES PANEL AND CIRCUITPANEL BOARD or SWITCHGEAR (SEE PANEL SCHEDULES AND RISER DIAGRAM);SPECIAL PANEL, EQUIPMENT RACK, CABINET, ETC. - SURFACE MOUNT ; FLUSH MOUNTTXPOWER TRANSFORMER - SEE PANEL SCHEDULE, RISER AND SPECIFICATIONSDISCONNECT / SAFETY SWITCH - SEE SCHEDULES FOR MORE INFORMATION;GROUND ; WEATHERHEAD;J; JGFCI DUPLEX RECEPTACLE @6" ABOVE BACKSPLASH IF SHOWN AT MILLWORK or @18" AFF ; WEATHERPROOF GFCIJUNCTION BOX - @ 18" AFF OR AS NOTED ; FLUSH WALLS / FLUSH CEILING or FLOOR or ELSE;;SRRECEPTACLE @18" AFF OR AS NOTED - DUPLEX ; QUAD ; SIMPLEXSURFACE-MOUNT RACEWAY - SEE SPECIFICATIONS FOR MORE INFORMATIONFIRE ALARM SIGNALLIGHT SWITCH BANK (REFER TOSTACKING DIAGRAM)THERMOSTATINTERCOMDEVICEFIRE ALARMPULL STATION80"4" 4" 4"ELECTRICAL ANDCOMMUNICATION4"44"OUTLETS.18"SWITCH & OUTLET LOCATION DIAGRAM1 TO 45 TO 67 TO 8NOTE:1. IF HIGH WATTAGE DIMMERS ARE USED ADJACENTTO LIGHTING BANK, STACKING IS TO BE USED ASINDICATED.2. PROVIDE SINGLE GANGING PLATE W/ 1, 2, 3, OR 4SWITCH LEG CAPACITY WHEREVER POSSIBLE.PLANDIMEN.COVER PLATE STACKING DIAGRAMPLANDIMEN.PLANDIMEN.4" 4"MAX. MAX.4" MAX.4" MAX.FLOOR OUTLET DIAGRAMOUTLET DIAGRAMN.T.S.4" 4"MAX. MAX.KEY PLANEMA JOB #: 5-001-1898-006DRAWN BY:MSACHECKED:CMCELECTRICAL DETAILS,NOTES, AND SYMBOLSSHEET NUMBERSUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THECONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTINGAND NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE ANDWORKING SYSTEM.EP7.1
- Commodity Codes
-
- NAICS 238210Electrical Contractors and Other Wiring Installation Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
* Rebid* Proprietary* Enteral...
Bid Number Description Date Issued Bid Open Date/Time 3000026431 * Rebid* Proprietary* Enteral
State Government of Louisiana
Bid Due: 7/14/2026
Bid Number Description Date Issued Bid Open Date/Time 50005-002991 DENTAL SUPPLIES Original: 50005-002991
State Government of Louisiana
Bid Due: 7/14/2026