Communications Tower

Project Information

Bid Title
Communications Tower
Issuing Agency
City of Mount Vernon
Location
Illinois
Published Date
Jun 8, 2026
Closing Date
Jul 1, 2026
Government Level
State & Local
Status
Closed
Original Source
Join to Access Full Details
Project Description

The City of Mount Vernon, Illinois, is seeking proposals for the design, engineering, and permitting services for a communications tower. All qualified contractors/vendors are invited to submit a sealed proposal.

Important Dates

Due Date & Time: Wednesday, July 1, 2026, at 1 p.m. (local time)

Submission Requirements

Email subject lines shall be clearly marked: “Communications Tower.”

Email:
bryan.jennings@mtvernon.com

Questions
Questions regarding this proposal should be directed to:

Bryan Jennings
Assistant Fire Chief
Phone: 618-316-9303
Email: bryan.jennings@mtvernon.com

Proposal Documents

Attachment Preview
REQUEST FOR PROPOSALS (RFP)
Engineering Design and Permitting Services
250-Foot Self-Supporting Communications Tower
1. INTRODUCTION
The Owner is soliciting proposals from qualified engineering consultants to provide
comprehensive design, engineering, and permitting services for a 250-foot self-supporting
communications tower and associated site improvements.
The proposed tower will support public safety communications and related municipal operations.
The selected consultant shall provide all professional services necessary to deliver a fully
permitted, constructible design, including coordination with regulatory agencies, preparation of
sealed construction documents, and support during bidding and construction.
The Owner intends to advance this project in a timely manner and desires to initiate construction
as soon as practicable. Consultants should provide an efficient, realistic project schedule that
supports timely permitting, design completion, and construction readiness.
All work shall be performed under the supervision of a Professional Engineer licensed in the
State of Illinois.
2. PROJECT INFORMATION
Project Title: 250-Foot Communications Tower Project
Project Location: Mt Vernon, IL
Owner: City of Mt Vernon
Project Purpose: Construction of a communications tower to support public safety radio
communications (City and County VHF frequencies) and municipal telemetry systems,
with consideration for future equipment and co-location.
3. SCOPE OF SERVICES
The consultant shall provide all labor, materials, and expertise required to complete the
following:
3.1 Site Evaluation and Due Diligence
Review site conditions, access, and existing infrastructure
Coordinate and manage geotechnical investigation, including soil borings and report
Coordinate and/or procure boundary and topographic survey as required for design and
permitting
Identify zoning requirements, setbacks, and land use constraints
1
Evaluate utility availability and site access requirements
3.2 Engineering Design
Structural design of a 250-foot self-supporting (lattice) communications tower
Foundation design based on geotechnical findings
Design of mounting systems for antennas, platforms, and cable management
Wind, ice, and seismic loading analysis per applicable standards
Design of site improvements including access roads, grading, and drainage
Design of electrical service, grounding, and lightning protection systems
3.3 Regulatory Compliance and Permitting
The consultant shall prepare, submit, and coordinate all required applications and approvals,
including but not limited to:
Local zoning approvals (conditional use permits, variances if required)
Building permits
FAA review and determinations, including preparation and submission of required
applications
FCC compliance and Antenna Structure Registration (ASR)
Environmental and historic preservation reviews (NEPA, SHPO, if applicable)
The consultant shall respond to agency comments and revise submissions as needed to obtain
approvals.
3.4 Construction Documents
Prepare complete, signed, and sealed construction documents including:
Site plans (grading, drainage, access)
Structural drawings and details
Foundation plans and details
Tower elevations and equipment layouts
Electrical/grounding plans
3.5 Bidding and Construction Support
Assistance in preparation of contractor bid packages
Respond to Requests for Information (RFIs)
Review contractor submittals and shop drawings
Provide construction observation services; scope and level of effort to be defined in the
proposal
2
4. DELIVERABLES
The consultant shall provide the following:
Signed and sealed engineering drawings (PDF and editable CAD format)
Structural calculations
Geotechnical report
Survey documentation (if performed under this contract)
Complete permit application packages
FAA/FCC documentation
Final “Issued for Construction” (IFC) document set
Bidding documents and technical specifications
5. APPLICABLE CODES AND STANDARDS
All work shall comply with the latest adopted versions of applicable codes and standards,
including but not limited to:
ANSI/TIA-222 (Structural Standard for Antenna Supporting Structures)
International Building Code (IBC)
Applicable state and local building codes
FAA and FCC regulations
OSHA requirements and considerations for design safety
6. CONSULTANT QUALIFICATIONS
Proposals will only be considered from firms meeting the following minimum qualifications:
Licensed Professional Engineer (PE) in the State of Illinois
Demonstrated experience with at least three (3) similar communications tower projects
exceeding 200 feet in height
Proven experience with permitting processes in applicable jurisdictions
Familiarity with FAA and FCC regulatory requirements
7. PROJECT SCHEDULE
The consultant shall provide a detailed project schedule identifying major tasks, milestones, and
anticipated review durations.
At a minimum, the schedule shall include the following:
Notice to Proceed to Preliminary Design
Permitting Submissions and Agency Review
Final Construction Documents
3
The schedule shall account for coordination with the Owner, regulatory review timelines, and
potential revisions required to obtain approvals.
8. PROPOSAL REQUIREMENTS
Proposals shall include the following:
1. Cover Letter
2. Technical Approach describing the firm’s understanding of the project, methodology,
and key considerations
3. Relevant Experience including similar completed projects
4. Key Personnel and resumes
5. Project Schedule
6. Fee Proposal (lump sum or hourly with not-to-exceed amount)
7. Assumptions and Exclusions
8. References (minimum of three, including contact information)
9. EVALUATION CRITERIA
Proposals will be evaluated based on the following criteria:
Relevant Experience: 30%
Technical Approach: 25%
Project Schedule: 15%
Cost: 20%
References: 10%
The Owner reserves the right to request interviews with selected firms and to consider interview
performance, if conducted, in the final evaluation.
10. INSURANCE AND CONTRACT REQUIREMENTS
The selected consultant shall:
Maintain professional liability insurance in an amount not less than $1,000,000.00.
Provide proof of general liability and workers’ compensation insurance
Agree to standard indemnification provisions
Acknowledge that all deliverables become property of the Owner upon completion
11. ADDITIONAL REQUIREMENTS
Coordination with utility providers as necessary
Identification of any subcontractors and their roles
Provide alternate pricing for optional services (e.g., construction phase support), if not
included in the base proposal
4
12. SUBMISSION INSTRUCTIONS
Proposal Due Date: July 1, 2026, at 1:00 p.m. local time
Submission Method: Electronic submission via email to
bryan.jennings@mtvernon.com. Email subject lines shall be clearly marked:
“Communications Tower”.
Contact for Questions:
Bryan Jennings
Assistant Fire Chief
bryan.jennings@mtvernon.com
(618) 316-9303
All questions regarding this RFP may be submitted by email or phone and must be received no
later than 5 p.m. local time on June 24, 2026.
13. RESERVATION OF RIGHTS
The Owner reserves the right to:
Reject any or all proposals
Waive informalities or irregularities in proposals
Request clarification or additional information from any proposer
Cancel or reissue this RFP at any time
Accept the proposal deemed to be in the best interest of the Owner
14. ATTACHMENTS
Project site aerial map (GIS)
Site location information
5
Commodity Codes
  • NAICS 237130Power and Communication Line and Related Structures Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.

Government Bids

Empower Your Bidding Strategy

Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.

  • Access an extensive database of bids, including comprehensive local and state opportunities.
  • Receive customized alerts for the bids that matter most to your business.
  • Explore detailed specifications to ensure precise and competitive submissions.
  • Gain a competitive edge with up-to-date information and exclusive opportunities.

See Also

Custom Multi-Layered Dimensio...

Follow Custom Multi-Layered Dimensional Command Shield Sign System Active Contract Opportunity Notice ID

DEPT OF DEFENSE

Bid Due: 7/12/2026

JOL-08-05 Storage Tanks (West...

Project: JOL-08-05 Storage Tanks (West & Central HPZ/Stryker/Washington) Ref. #: 2939-0426 Type: RFQ

City of Joliet

Bid Due: 7/24/2026