Communications Tower
Project Information
- Bid Title
- Communications Tower
- Issuing Agency
- City of Mount Vernon
- Location
- Illinois
- Published Date
- Jun 8, 2026
- Closing Date
- Jul 1, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
The City of Mount Vernon, Illinois, is seeking proposals for the design, engineering, and permitting services for a communications tower. All qualified contractors/vendors are invited to submit a sealed proposal.
Important Dates
Due Date & Time: Wednesday, July 1, 2026, at 1 p.m. (local time)
Submission Requirements
Email subject lines shall be clearly marked: “Communications Tower.”
Email:
bryan.jennings@mtvernon.comQuestions
Questions regarding this proposal should be directed to:Bryan Jennings
Assistant Fire Chief
Phone: 618-316-9303
Email: bryan.jennings@mtvernon.com - Attachment Preview
-
REQUEST FOR PROPOSALS (RFP)Engineering Design and Permitting Services250-Foot Self-Supporting Communications Tower1. INTRODUCTIONThe Owner is soliciting proposals from qualified engineering consultants to providecomprehensive design, engineering, and permitting services for a 250-foot self-supportingcommunications tower and associated site improvements.The proposed tower will support public safety communications and related municipal operations.The selected consultant shall provide all professional services necessary to deliver a fullypermitted, constructible design, including coordination with regulatory agencies, preparation ofsealed construction documents, and support during bidding and construction.The Owner intends to advance this project in a timely manner and desires to initiate constructionas soon as practicable. Consultants should provide an efficient, realistic project schedule thatsupports timely permitting, design completion, and construction readiness.All work shall be performed under the supervision of a Professional Engineer licensed in theState of Illinois.2. PROJECT INFORMATION• Project Title: 250-Foot Communications Tower Project• Project Location: Mt Vernon, IL• Owner: City of Mt Vernon• Project Purpose: Construction of a communications tower to support public safety radiocommunications (City and County VHF frequencies) and municipal telemetry systems,with consideration for future equipment and co-location.3. SCOPE OF SERVICESThe consultant shall provide all labor, materials, and expertise required to complete thefollowing:3.1 Site Evaluation and Due Diligence• Review site conditions, access, and existing infrastructure• Coordinate and manage geotechnical investigation, including soil borings and report• Coordinate and/or procure boundary and topographic survey as required for design andpermitting• Identify zoning requirements, setbacks, and land use constraints1• Evaluate utility availability and site access requirements3.2 Engineering Design• Structural design of a 250-foot self-supporting (lattice) communications tower• Foundation design based on geotechnical findings• Design of mounting systems for antennas, platforms, and cable management• Wind, ice, and seismic loading analysis per applicable standards• Design of site improvements including access roads, grading, and drainage• Design of electrical service, grounding, and lightning protection systems3.3 Regulatory Compliance and PermittingThe consultant shall prepare, submit, and coordinate all required applications and approvals,including but not limited to:• Local zoning approvals (conditional use permits, variances if required)• Building permits• FAA review and determinations, including preparation and submission of requiredapplications• FCC compliance and Antenna Structure Registration (ASR)• Environmental and historic preservation reviews (NEPA, SHPO, if applicable)The consultant shall respond to agency comments and revise submissions as needed to obtainapprovals.3.4 Construction DocumentsPrepare complete, signed, and sealed construction documents including:• Site plans (grading, drainage, access)• Structural drawings and details• Foundation plans and details• Tower elevations and equipment layouts• Electrical/grounding plans3.5 Bidding and Construction Support• Assistance in preparation of contractor bid packages• Respond to Requests for Information (RFIs)• Review contractor submittals and shop drawings• Provide construction observation services; scope and level of effort to be defined in theproposal24. DELIVERABLESThe consultant shall provide the following:• Signed and sealed engineering drawings (PDF and editable CAD format)• Structural calculations• Geotechnical report• Survey documentation (if performed under this contract)• Complete permit application packages• FAA/FCC documentation• Final “Issued for Construction” (IFC) document set• Bidding documents and technical specifications5. APPLICABLE CODES AND STANDARDSAll work shall comply with the latest adopted versions of applicable codes and standards,including but not limited to:• ANSI/TIA-222 (Structural Standard for Antenna Supporting Structures)• International Building Code (IBC)• Applicable state and local building codes• FAA and FCC regulations• OSHA requirements and considerations for design safety6. CONSULTANT QUALIFICATIONSProposals will only be considered from firms meeting the following minimum qualifications:• Licensed Professional Engineer (PE) in the State of Illinois• Demonstrated experience with at least three (3) similar communications tower projectsexceeding 200 feet in height• Proven experience with permitting processes in applicable jurisdictions• Familiarity with FAA and FCC regulatory requirements7. PROJECT SCHEDULEThe consultant shall provide a detailed project schedule identifying major tasks, milestones, andanticipated review durations.At a minimum, the schedule shall include the following:• Notice to Proceed to Preliminary Design• Permitting Submissions and Agency Review• Final Construction Documents3The schedule shall account for coordination with the Owner, regulatory review timelines, andpotential revisions required to obtain approvals.8. PROPOSAL REQUIREMENTSProposals shall include the following:1. Cover Letter2. Technical Approach describing the firm’s understanding of the project, methodology,and key considerations3. Relevant Experience including similar completed projects4. Key Personnel and resumes5. Project Schedule6. Fee Proposal (lump sum or hourly with not-to-exceed amount)7. Assumptions and Exclusions8. References (minimum of three, including contact information)9. EVALUATION CRITERIAProposals will be evaluated based on the following criteria:• Relevant Experience: 30%• Technical Approach: 25%• Project Schedule: 15%• Cost: 20%• References: 10%The Owner reserves the right to request interviews with selected firms and to consider interviewperformance, if conducted, in the final evaluation.10. INSURANCE AND CONTRACT REQUIREMENTSThe selected consultant shall:• Maintain professional liability insurance in an amount not less than $1,000,000.00.• Provide proof of general liability and workers’ compensation insurance• Agree to standard indemnification provisions• Acknowledge that all deliverables become property of the Owner upon completion11. ADDITIONAL REQUIREMENTS• Coordination with utility providers as necessary• Identification of any subcontractors and their roles• Provide alternate pricing for optional services (e.g., construction phase support), if notincluded in the base proposal412. SUBMISSION INSTRUCTIONS• Proposal Due Date: July 1, 2026, at 1:00 p.m. local time• Submission Method: Electronic submission via email tobryan.jennings@mtvernon.com. Email subject lines shall be clearly marked:“Communications Tower”.• Contact for Questions:Bryan JenningsAssistant Fire Chiefbryan.jennings@mtvernon.com(618) 316-9303All questions regarding this RFP may be submitted by email or phone and must be received nolater than 5 p.m. local time on June 24, 2026.13. RESERVATION OF RIGHTSThe Owner reserves the right to:• Reject any or all proposals• Waive informalities or irregularities in proposals• Request clarification or additional information from any proposer• Cancel or reissue this RFP at any time• Accept the proposal deemed to be in the best interest of the Owner14. ATTACHMENTS• Project site aerial map (GIS)• Site location information5
- Commodity Codes
-
- NAICS 237130Power and Communication Line and Related Structures Construction
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Custom Multi-Layered Dimensio...
Follow Custom Multi-Layered Dimensional Command Shield Sign System Active Contract Opportunity Notice ID
DEPT OF DEFENSE
Bid Due: 7/12/2026
JOL-08-05 Storage Tanks (West...
Project: JOL-08-05 Storage Tanks (West & Central HPZ/Stryker/Washington) Ref. #: 2939-0426 Type: RFQ
City of Joliet
Bid Due: 7/24/2026