HVAC Equipment Replacement for Northeast Middle School
Project Information
- Bid Title
- HVAC Equipment Replacement for Northeast Middle School
- Issuing Agency
- Guilford County Schools
- Location
- North Carolina
- Published Date
- May 7, 2026
- Closing Date
- May 19, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- 6829
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
QuoteID Description Bids Closed Scope of Work 6829HVAC Equipment Replacement for Northeast Middle School HVAC Equipment Replacement for Northeast Middle School HVAC Equipment Replacement for Northeast Middle School05/19/2026 - Attachment Preview
-
HVAC EQUIPMENT REPLACMENTFORNORTHEAST GUILFORD MIDDLE SCHOOL6720 McLEANSVILLE ROADNA ALMcLEANSVILLE, NORTH CAROLINAPERGUILFORD COUNTY BOARD OF EDUCATIONDr. WHITNEY OAKLEYSUPERINTENDENTSIGNATURE:DATE:SIGNATURE:DATE:SIGNATURE:DATE:TRIAD ENGINEERING CONSULTANTS, INCPLUMBINGMECHANICAL ANDELECTRICAL ENGINEERINGEmail: Admin@TriadEngMEP.com2638-100 Willard Dairy RdHigh Point, NC 27265(336) 338-8943Firm LicenseC-04922605ENGINEERINGTHE PIEDMONTTRIAD SINCE 19840 VICINITY MAPSITE27090 NO SCALE180SHEET NO.C4"SUCTIONHYDRONIC INDICATORASSEMBLYSHUTOFF VALVE(BUTTERFLY)SUCTION DIFFUSERSERVICE CLEARANCEFOR STRAINER REMOVALADJUSTABLE SUPPORT FOOTDISCHARGECONCENTRIC REDUCER (AS REQUIRED)FLEX CONNECTOR(TYP)TRIPLE DUTY VALVEBASE MOUNTED PUMP -SEE SCHEDULEMOTOR -SEE SCHEDULEPUMP & MOTOR BASE1/2" DRAIN TO FLOOR DRAINDETAIL4 BASE MOUNTED PUMPME0.01 SCALE: NONEFLOORINERTIA BASE ON ISOLATION SPRINGS.DIMENSIONS TO BE AT LEAST 4" LARGERTHAN PUMP BASE PLUS SUCTIONDIFFUSER FOOT SUPPORT.FILL BASE WITH CONCRETE.ELECTRICAL SYMBOL LEGENDSYMBOL"NL"DESCRIPTIONA LINEAR LIGHT FIXTURE - LETTER INDICATES FIXTURE TYPE. SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS. HALF SHADING INDICATES FIXTURE TO BEEQUIPPED WITH EMERGENCY BATTERY PACK WIRED TO UNSWITCHED CONDUCTOR TO PROVIDE 90 MINUTES OPERATION ON POWER LOSS.DENOTES LIGHTING FIXTURE TO BE USED AS A NIGHTLIGHT. FIXTURE SHALL BE CONNECTED UNSWITCHED TO THE LOCAL LIGHTING CIRCUIT.UNIVERSAL MOUNT EMERGENCY EXIT FIXTURE (SHADING INDICATES FACES). ARROW INDICATES DIRECTIONAL ARROWS REQUIRED. MOUNT TO CEILING ATLOCATION INDICATED. MOUNT TO WALL IF CEILING IS HIGHER THAN 12'-0". CIRCUIT TO LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHING.SURFACE MOUNTED PANELBOARDJ WP OR J WP JUNCTION BOX SIZED PER N.E.C. REQUIREMENTS. 'WP' INDICATES WEATHERPROOF.WIRING AND RACEWAY CONCEALED IN WALLS AND/OR ABOVE CEILINGSWITCH LEG WIRING AND RACEWAY CONCEALED IN WALLS AND/OR ABOVE CEILINGWIRING AND RACEWAY CONCEALED IN/OR UNDER FLOOR OR UNDERGROUNDLOW VOLTAGE CONDUIT AND WIRING - BY E.C. CONDUIT SIZE IS 1/2" UNLESS NOTED OTHERWISE.INDICATES CONDUIT TURNED DOWN TO FLOOR BELOWINDICATES CONDUIT TURNED UP TO FLOOR ABOVELP1-2 CIRCUIT HOMERUN WITH PANEL DESIGNATION AND CIRCUIT NUMBER.120, 208, 277, OR 480 VOLT MOTOR AS NOTED ON PLANS240V/3P/200A/N3R/FPNHEAVY DUTY LOCKABLE DISCONNECT SWITCH - FUSED OR NON-FUSED AS INDICATED - BY E.C.VOLTAGE/#POLES/AMPERAGE/NEMA RATING/FUSE CONDITION FUSE CONDITION AS FOLLOWS: NF=(NON-FUSED), FPN=(FUSE PER EQUIPMENT NAMEPLATE),XXXAFU=FUSED WITH XXX AMP FUSES, SE = SERVICE ENTRANCE LABEL. FURNISH WITH GROUND BAR. FURNISH WITH SOLID NEUTRAL WHEN A NEUTRALCONDUCTOR IS INCLUDED IN THE CIRCUIT OR FEEDER.COMBINATION STARTER AND FUSED DISCONNECT SWITCH - BY E.C. UNLESS NOTED OTHERWISEMECHANICAL LEGENDEXISTING PIPING (THIN LINEWEIGHT)NEW PIPING (THICKER LINEWEIGHT)HWSHOT WATER SUPPLY PIPING - BOILER LOOPHWRHOT WATER RETURN PIPING - BOILER LOOPHWSBHOT WATER SUPPLY PIPING - BUILDING LOOPHWRBHOT WATER RETURN PIPING - BUILDING LOOPMAKEUP WATER PIPING FOR EQUIPMENTCONCRETE SHALL BE 3000 PSI AIR ENTRAINED MIX.*TOP OF PAD TO BE SMOOTH AND LEVEL.#5x6" DOWELS AT 8" O.C.AROUND PERIMETER OF PADUSE THIS PAD DETAIL FOR SHOT FEEDER ONLYSHOT FEEDER3 CONCRETE PAD DETAILME0.01 SCALE: NONESYSTEM RETURN PIPING. SEE PLAN FOR SIZE.HWSHWRLID AND FUNNEL1/2"x1/2" CHAMFER ALL AROUND#4 WELDED WIRE FABRIC4 QT ASME POT FEEDER TANKNEEDLE VALVE1/4" BALL VALVE FOR SAMPLING - WITHBRASS CHAIN TETHERED CAP.DRAIN VALVE WITH BRASSCHAIN TETHERED CAPPAINTED STEEL FRAME WITH4" CONC. PADLEGS BOLTED TO PAD ALL PIPING 3/4" UNLESS NOTED OTHERWISEALL VALVES ARE 3/4" BALL VALVES UNLESS NOTED OTHERWISEPROVIDE ONE SHOT FEEDER IN MECHANICAL ROOM FOR HW SYSTEM.DETAILHYDRONIC CHEMICAL2 SHOT FEEDER SYSTEMME0.01 SCALE: NONE3/4" BYPASS LOOP0-80 PSIPRESSURE GAGEUNION (TYP)DIELECTRIC UNIONPCONNECT TO AIRRELEASE LINE0-200 PSI PRESSUREGAGEPEXIST. PIPING WHEREAPPLICABLEWATER METER EQUAL TOHERSEY 452NEW LEAD-FREE REDUCED PRESSUREZONE BACKFLOW PREVENTER.PRESSURE REDUCING VALVESET AT 18 PSIGBALL VALVE (TYP.)** ALL MAKE-UP WATER PIPING SHALL BE 1" COPPER U.N.O.MAKEUP WATER1 CIRCUIT DETAILME0.01 SCALE: NONEPIPE AIR GAP FUNNEL DRAINTO FLOOR DRAIN OR SUMPEXIST. COPPERCW FROMMANIFOLD INMECH. RMHYDRONIC INDICATOR ASSEMBLY AND TUBING TOCHECK PUMP PERFORMANCE.5X4 ECCENTRIC REDUCER (FLAT ON MOTOR SIDE)4" SHUTOFF VALVE4" FLEX CONNECTOR (TYP).SUCTION DIFFUSER WITH SCREEN REMOVALCLEARANCE.MOTOR SERVICECLEARANCEMOTOR - SEE SCHEDULEFLEX CONNECTOR(PUMP OUTLET SIZED)INLINE TRIPLE DUTY VALVE(PUMP OUTLET SIZED)PUMP - SEE SCHEDULEREDUCER AND BLIND FLANGE TO MATE WITH PUMPBASE FLANGE PATTERN.3"∅ STEEL WELDED PIPE STAND ANCHORED TOFLOOR WITH EPOXY SET ANCHOR BOLTS AND BLINDFLANGE OR 12x12x1/4" STEEL PLATE.ADJUSTABLE FLOOR SUPPORT BOLTED TO FLANGEAND FLOOR.ADJUSTABLE SADDLE TYPE PIPE SUPPORT FORSUPPLY PIPING.HIGH CAPACITY AIR VENTBUILT-IN HIGHCAPACITY AIR VENTDAS DIRT-AIR SEPARATOR -B&G SRS OR EQUAL. (INSULATE)RETURN FROM SYSTEM -SEE PLAN FOR SIZEBUTTERFLY VALVEAT INLETPROVIDE MANUALBLOWDOWN VALVEAT OUTLETROUTE DISCHARGES TOFLOOR DRAIN OR SUMP1-1/2" AIR RELEASEPIPING TO CONNECT TOEXIST. TANKS.MAKEUP WATER CIRCUIT - SEEDETAIL THIS SHT.TO COMP. TANKS - SEEPLAN.PRESSURE RELIEF VALVESET AT 75 PSITO PUMP SUCTION -SEE PLAN FOR SIZEDETAIL5 INLINE PUMPME0.01 SCALE: NONEGENERAL MECHANICAL NOTES1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE N.C. STATE BUILDING CODE AND LOCAL CODESAND ORDINANCES. MATERIALS SHALL BE NEW UNLESS NOTED OTHERWISE.2. OBTAIN AND PAY FOR ALL PERMITS, FEES, INSPECTIONS ETC. AS REQUIRED FOR WORK UNDER THIS CONTRACT.3. SCHEDULE ALL REQUIRED INSPECTIONS WITH AHJ AND MAKE CORRECTIONS RESULTING FROM INSPECTIONS. PROVIDE ALL ACCESS, LADDERS,EQUIPMENT, INSTRUMENTS, ETC AS REQUIRED BY AHJ TO MAKE INSPECTIONS.4. HYDRONIC HOT WATER PIPING SHALL BE SCHEDULE 40 BLACK STEEL.5. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL EXCEPT CONNECTIONS TO EQUIPMENT SHALL BE FLEXIBLE STAINLESS STEEL.6. STEEL PIPING 2" AND SMALLER PIPING SHALL BE THREADED AND COUPLED WITH CAST IRON FITTINGS. STEEL PIPING 2-1/2" AND LARGERPIPING SHALL BE WELDED WITH STANDARD PATTERN FITTINGS. SEGMENTED FITTINGS SHALL NOT BE UTILIZED UNLESS NO STANDARD FITTING ORCOMBINATION OF FITTINGSWILL MAKE THE REQUIRED DIRECTIONAL CHANGE IN THE AVAILABLE SPACE.7. THREADED JOINTS SHALL BE MADE WITH NPT THREADS AND UTILIZING A THREAD SEALING COMPOUND. REMOVABLE UNIONS SHALL BE PROVIDEDTO ALLOW REMOVAL OF VALVES AND EQUIPMENT. DI-ELECTRIC UNIONS ORE DI-ELECTRIC NIPPLES SHALL BE USED WHERE PIPING OF DISSIMILARMETALS ARE JOINED.8. WELDED JOINTS SHALL BE MADE WITH BUTT-WELDED JOINTS. WELDERS SHALL BE ASME CERTIFIED. BOLT FLANGES SHALL BE PROVIDED TOALLOW REMOVAL OF VALVES AND EQUIPMENT.9. SUPPORT PIPING WITH MSSP STANDARD GALVANIZED STEEL PIPE HANGERS SIZED FOR THE DIAMETER OF THE PIPE PLUS INSULATION THICKNESSAND SPACED NO FURTHER THAN 8' ON CENTER AND WITHIN 2' OF ELBOWS. SUPPORT SUSPENDED HANGERS WITH ALL-THREAD ROD SECUREDWITH DOUBLE NUTS TO LOCK POSITION. PROVIDE SADDLE SUPPORTS WITH TOP RESTRAINTS ANCHORED TO BASE FOR NON-SUSPENDEDSUPPORTS. SADDLE SUPPORTS SHALL BE ANCHORED TO STRUCTURE.10. HOT WATER PIPING PIPING SHALL BE INSULATED WITH 1-1/2" WALL THICKNESS PREFORMED HIGH DENSITY 3 POUND PER CUBIC FOOT PIPEINSULATION WITH ALL SERVICE JACKET THAT IS THEN COVERED WITH PVC JACKET. FITTINGS SHALL BE INSULATED WITH LOOSE OR SEGMENTEDFIBERGLASS INSULATION IN PVC FITTING COVERS. TAPE ALL SEAMS AND JOINTS. PROVIDE RIGID INSERTS AND ROLL-FORMED GALVANIZED STEELPIPE SHIELDS AT HANGERS. SECURE PIPE SHIELD TO INSULATED PIPE WITH BLACK ZIP TIE. SEAL ENDS OF EACH SECTION OF INSULATION WITHMASTIC PRIOR TO INSTALLATION.11. ALL NEW INTERIOR HOT WATER SUPPLY AND RETURN PIPING, MAKEUP WATER PIPING, FITTINGS, AND VALVES SHALL BE COVERED WITH PVCJACKET COLORED FOR SERVICE: RED COLOR FOR HOT WATER SUPPLY AND RETURN. GREEN COLOR FOR MAKEUP WATER.12. LABEL ALL NEW PIPING WITH PLASTIC MARKERS ENCIRCLING CIRCUMFERENCE OF INSULATED PIPE DENOTING SERVICE AND WITH FLOW ARROWS TOINDICATE FLUID FLOW DIRECTION. SECURE MARKERS WITH (2) BLACK ZIP TIES LOCATED NEAR ENDS OF PIPE MARKER.11. LABEL BOILERS AND PUMPS WITH LAMINATED NAMEPLATE FIELD WITH 1/2" HIGH WHITE LETTERS. SCREW ATTACHED TO THE FRAME OF THEEQUIPMENT.12. NEW HVAC CONTROLS SHALL BE AN OPEN PROTOCOL BACNET SYSTEM UTILIZING BTL LISTED DEVICES AND COMMUNICATING USING BACNETPROTOCOL. SYSTEMS USING PROPRIETARY LEVEL PROTOCOL ARE NOT ALLOWED.13. PROVIDE CONDUIT FOR ALL NEW CONTROL WIRING - EMT FOR INDOOR APPLICATIONS AND RIGD OR IMC FOR EXTERIOR APPLICATIONS.14. WARRANTY ALL WORK, EQUIPMENT, AND MATERIALS FOR A MINIMUM OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER.15. WARRANTY REFRIGERANT AND COMPRESSOR PARTS FOR AN ADDITIONAL 4 YEARS BASE BID WITH NO DEDUCTIBLE TO REPLACE PARTS AND ALLREFRIGERANT LOST OR CONTAMINATED BY EQUIPMENT BURNOUT.16. WARRANTY REFRIGERANT AND COMPRESSOR PARTS FOR AN ADDITIONAL 5 YEARS UNDER ALTERNATE 2.DAS AND6 AIR CONTROL PIPING DETAILME0.01 SCALE: NONEGENERAL ELECTRICAL NOTES1. ELECTRICAL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE ANDALL APPLICABLE LOCAL AND STATE CODES.2. ALL REQUIRED ELECTRICAL PERMITS AND INSPECTION FEES SHALL BE OBTAINED AND PAID FOR BY THE ELECTRICAL CONTRACTOR.3. SCHEDULE ALL REQUIRED INSPECTIONS WITH AHJ AND MAKE CORRECTIONS RESULTING FROM INSPECTIONS. PROVIDE ALL ACCESS, LADDERS,EQUIPMENT, INSTRUMENTS, ETC AS REQUIRED BY AHJ TO MAKE INSPECTIONS4. COORDINATE WITH EQUIPMENT SUPPLIER FOR FIELD WIRING OF COMPONENTS REQUIRED FOR OPERATION OF EQUIPMENT.5. FIELD VERIFY ALL EXISTING CIRCUITS, PANELS, BREAKERS ETC FOR RATINGS, CAPACITIES, LOCATION, AND CONDITION TO ENSURE SUITABILITYFOR USE AND MAKE MODIFICATIONS REQUIRED FOR NEW CONFIGURATIONS.6. GUARANTEE ALL WORK AND MATERIALS FOR ONE YEAR EFFECTIVE THE DAY THE PROJECT IS ACCEPTED BY OWNER.7. ALL MATERIALS SHALL BE NEW AND U.L. LISTED UNLESS SPECIFICALLY NOTED OTHERWISE.8. MAKE ALL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING POWER CONNECTIONS.9. GENERAL WIRING SHALL BE INDIVIDUAL COPPER CONDUCTORS WITH THHN/THWN INSULATION UNLESS NOTED OTHERWISE RATED AT NOT LESSTHAN 600 VOLTS AND CONCEALED IN CONDUIT. MINIMUM WIRE SIZE IN CONDUIT IS #12 AWG. #12 AND #10 CONDUCTORS SHALL BESOLID. CONDUCTORS #8 AND LARGER SHALL BE STRANDED TYPE. WIRING TO LIGHTING FIXTURES SHALL BE AS REQUIRED BY U.L. LABEL.10. CONDUIT SHALL BE RIGID OR IMC OUTDOORS AND IN UTILITY ROOMS WHEN WITHIN 10' OF FLOOR OR PLATFORM LEVEL. CONDUITS INSTALLEDABOVE 10' INDOORS MAY BE EMT. USE RMC OR IMC FOR EXPOSED OUTDOOR APPLICATIONS. USE SCHEDULE 40 PVC BELOW GRADE ORFLOOR SLAB. USE IMC OR RMC WHERE REQUIRED BY CODE OR WHERE SUBJECT TO PHYSICAL DAMAGE INCLUDING CONDUITS WITHIN 10' OFFLOOR IN UTILITY ROOMS. USE IMC OR RMC FOR CONDUIT INSTALLED IN HAZARDOUS AREAS. USE IMC OR RMC ELBOWS WHERETRANSITIONING FROM BELOW GRADE TO ABOVE GRADE.11. SUPPORT ALL CONDUIT WITH STRAPS AND CLAMPS. RUN ALL CONDUIT PARALLEL OR PERPENDICULAR TO STRUCTURE. SECURE SUPPORTS TOSTRUCTURE.12. SECURE CONDUITS TO STRUCTURE AT CONNECTIONS TO EQUIPMENT AND DEVICES. PROVIDE LB OR LR TYPE FITTING AND TRANSITION TOLIQUIDTITE FLEX OR MC CABLE AS APPLICABLE TO MAKE FINAL CONNECTIONS TO EQUIPMENT.13. COORDINATE CONDUIT LOCATIONS WITH LARGER UTILITIES SUCH AS PIPE AND DUCTS. CONDUITS SHALL BE COORDINATED AND ADJUSTED TOAVOID CONFLICTS.14. COORDINATE LOCATION AND REQUIREMENTS FOR ELECTRICAL CONNECTIONS TO EQUIPMENT.15. RECEPTACLES INSTALLED IN THE VERTICAL POSITION SHALL HAVE THE GROUND PIN ORIENTED IN THE UP POSITION.16. PROVIDE AN EMBOSSED ADHESIVE TAPE LABEL ON EACH RECEPTACLE, CONTROL DEVICE STATION, AND OTHER MISCELLANEOUS ITEMS.INDICATE PANELBOARD AND CIRCUIT NUMBER ON THE LABEL TO READILY IDENTIFY WHERE THE DEVICE IS SERVED FROM. THE LIGHT SWITCHLABEL SHALL BE PLACED ON THE BACKSIDE OF THE COVERPLATE. THE LETTERING SHALL BE 3/16" WHITE LETTERS ON BLACK BACKGROUNDOR BLACK LETTERS OR CLEAR BACKGROUND.17. LABEL INDIVIDUAL CONDUCTORS IN PANELBOARD, SWITCHBOARDS, JUNCTION BOXES, DEVICE BOXES, ETC. WITH WIRE MARKERS IDENTIFYING THECIRCUIT POSITION NUMBER TO WHICH THE CONDUCTOR IS CONNECTED.18. LABEL DISCONNECT SWITCHES, EQUIPMENT ENCLOSURE PANELS, ETC WITH ENGRAVED PHENOLIC NAMEPLATES ATTACHED TO THE COVER OF THEITEM IN A VISIBLE LOCATION. INCLUDE THE ITEM IDENTIFICATION, VOLTAGE, PHASE AND FEEDER OR CIRCUIT SOURCE WHERE APPLICABLE.ENGRAVED LABELS SHALL USE 1/2" HIGH LETTERING. USE BLACK PLATES WITH WHITE LETTERS FOR 277/480 VOLT EQUIPMENT. USE BLUEPLATES WITH WHITE LETTERS FOR 120/208 VOLT EQUIPMENT.19. PROVIDE NEW DIRECTORIES FOR EACH PANEL WITH CIRCUITS MODIFIED UNDER THIS CONTRACT. FIELD VERIFY EACH EXISTING CIRCUIT USE.MARK EXISTING BREAKERS THAT ARE NOT WIRED AS SPARE. THE PANEL DIRECTORIES SHALL BE TYPED.20. FUSES 0 -600 AMPS SHALL BE UL CLASS "RK1" LOW PEAK DUAL ELEMENT TIME DELAY AS MANUFACTURED BY BUSSMAN OR EQUAL.21. ALL TERMINALS, SPLICING CONNECTORS, LUGS, ETC. SHALL BE IDENTIFIED FOR USE WITH THE TYPE OF CONDUCTOR CONNECTED AND SHALLBE PROPERLY INSTALLED.NA ALPERSHEET NO.ME0.01MAIN ENTRYADMIN OFFICES(SECOND FLOOR)COMMONSGYMNASIUMEXIST. 5 PSI GAS PIPINGON ROOFEXIST. 7'x4' MASONRY CHIMNEY - PROVIDE (2) NEW14"∅ STAINLESS STEEL FLUE LINERS IN (2)VITRIFIED CLAY FLUES, AND NEW STAINLESS STEELCAP ON TOP OF CHIMNEY WITH SHED TOP ANDSCREENED SIDES. SEE DETAIL 3/503.MECHANICAL ROOM IN BASEMENTBELOW. SEE ME4.01 FOR ENLARGEDPLAN OF THIS ROOM.EXIST. 5 PSI GAS PIPINGON ROOFGAS DROP TO MECHANICALROOM BELOWMAIN BUILDINGANNEX CLASSROOMSCLASSROOM ANNEX - SEE ME4.02AND ME4.04 FOR WORK ON ROOFIN THIS AREANA ALPERAUXILLARY GYM - ALTERNATE BID #1.SEE ME4.03 AND ME4.05 FOR WORKON ROOF IN THIS AREAAUXILIARY GYMOVERALL1 CAMPUS BUILDINGS PLANME1.01 SCALE: 1/16" = 1'-0"SHEET NO.ME1.01PROVIDE ONE NEW STAINLESS STEEL HOOD (~7'x4'x2' TALL)WITH SIDE AND END SCREENS TO PROTECT (3) EXISTING17.25"x17.25" CHIMNEY FLUES. CHIMNEY TERMINATES ~5'ABOVE ROOF. REPAIR CHIMNEY CAP BLOCKS WITH NEWMORTAR AT JOINTS.DEMO 14"∅ FLUE PENETRATION THISFLUE AND INSTALL CLEANOUT TYPE CAPIN THIMBLE. SEAL TIGHT WITHSEALANT.DEMO 10"∅ FLUE PENETRATION THISFLUE. CORE DRILL NEW OPENING FOR15" ID THIMBLE FITTING.DEMO. COMPRESSION TANK ABOVE ANDASSOCIATED SUPPORTS.DEMO BOILER COMPLETE INCLUDINGASSOCIATED FLUE, HWS, HWR PIPINGTO HEADERS, POWER WIRING ANDCONTROLS WIRING. DEMO GAS PIPINGTO MAIN ABOVE. (TYP OF 3).DEMO GAS TRAIN TO BURNERS. PLUGAT CONNECTION TO ANY COMMON VENTPIPING.DEMO GAS BRANCH SERVING B3TO THIS POINT AND CAP MAIN.DEMO MAKEUP WATER CIRCUIT PIPINGABOVE AND DROPS TO BOILERS.EXIST. CHILLED WATER PUMPS ANDASSOCIATED PIPING, STARTERS,CONTROLS, ETC TO REMAIN. PROTECTFROM DAMAGE.EXIST. MAKEUP WATER CIRCUIT PIPINGABOVE TO REMAIN.EXIST. CHILLER AND ASSOCIATED PIPINGTO REMAIN. PROTECT FROM DAMAGEDEMO HWR AT FLOOR FROMHEADER TO BOILERS 1 & 280G HW COMPTANK (ABOVE)BOILERBOILERB3B2DEMO ALL SUPPLY AND RETURNPIPING FROM BOILERS TO SUPPLYAND RETURN HEADERS AT WALL.EXIST. 5" RETURN HEADER ~24"AFF AND ASSOCIATEDRISERS TO REMAIN UNLESS NOTED OTHERWISE.DEMO GAS TRAIN TO BURNERS.REUSE VENT LINES FOR NEWGAS TRAIN. (TYP OF 2)DEMO BOILER B3 RETURN RISER,AND CONTROL VALVE. PROVIDEBLIND FLANGE ON RISERSHUTOFF VALVEDEMO STARTERS AND SUPPORT FRAMINGFOR P8,10,11. DEMO CIRCUITS TOPANEL PB IN ELECTRICAL RM.P-8P-9BOILERP-10B1P-11DEMO 5" SUPPLY HEADER, ANDRISERS TO ~8' AFF. DEMO ALLPUMPS, VALVES, ETC. ZONESUPPLY PIPING ABOVE TO REMAIN.DEMO SUPPLY RISER FROM B-3INCLUDING CONTROL VALVE.GGDEMO AIR SEPARATOR ABOVEMCCP-12P-13GGRETAIN REGULATOR VENT PIPINGAND CONTROLS INTERFACEWIRING WITH BMS TO BERECONNECTED TO NEW BOILERS.(TYP OF 2)SUCTION RESIDUAL OIL FROM ABANDONED FUELOIL LINES. DEMO LINES FLUSH TO FLOOR ANDFILL WITH GROUT. (TYP AT EACH BOILER.)REMOVE AND SALVAGE SHOTFEEDER FOR REUSE IN NEWLOCATION.DEMO STARTER FOR P13. DEMO CIRCUITTO PANEL PB IN ELECTRICAL ROOM.EXIST. 120 GALLON COMPRESSION TANKS(4) ABOVE TO REMAIN. RECONNECT AIRRELEASE PIPING AS REQUIRED FORLOCATION OF NEW SEPARATOR.EXIST. ECONOMIZER HX ANDASSOCIATED PIPING TO REMAIN.PROTECT FROM DAMAGE.MECHANICAL ROOMCHW BUFFER GTANKGEXIST. CHILLED WATER BUFFER TANKAND ASSOCIATED PIPING TO REMAIN.PROTECT FROM DAMAGE.EXIST. GAS MAIN ATSTRUCTURE ABOVEEXIST. FD. PROTECT FROMCLOGGING AND DRAIN LINE ROD 50'CLEAR AT SUBSTANTIAL COMPLETION.(TYP OF 6 INCLUDING THE ONE INTHE ELECTRICAL RM.)EXIST. REFRIG. MONITOR TOREMAIN.EMEXIST. GAS DOMESTIC WATERHEATERS TO REMAIN. PROTECTFROM DAMAGE.PBEXIST. GAS RISER TO ROOFTO REMAIN.SLOPE DN.ENCLOSED COMBINATION SOFTSTARTERS EQUAL TO SQUARE DATS22D32S6U WITH INTEGRATEDBYPASS, A 50A BREAKER, A 32ACONTACTOR W/120V COIL. RUNINDICATING LIGHT AND MANUALH-O-A SWITCH ON FRONT OFNEMA 1 ENCLOSURE.1/2"C (3)#12+#12G TO NEW 35A/3PBRKR IN PANEL PB (TYP)1/2"C W/(3)#12+#12GINERTIA PAD FOR BASEMOUNTED PUMP (TYP).EXIST. INLINE CHILLEDWATER PUMP ~8' AFF.CONNECT NEW GAS PIPINGTO EXIST. 5 PSI MAINABOVE. (TYP).6X5 TEE ~12"AFF. RISE UP TO CONNECT TOEXIST. 5" AT ELBOW.6" HWR (12"AFF)NEW 5" BOILER LOOP HWS DROP TO 12" CLABOVE EXIST. HEADER. CONNECT TO NEW HWRRISEREXIST. 5" BHWR HEADER (~24"AFF)DV2DV15" HWS 11'AFFP91" BOILER DRAIN VALVE (TYP)NEW REINFORCED 6" CONC.PAD FOR EACH BOILER.NEW 5" HWR RISER FROM EXIST.BWR HEADER WITH VALVE IN RISER.BOILERP8B13082 MBHBOILERB23082 MBHGGGG1/2"C W/(3)#12+#12G2-1/2" LOW PRESSUREGAS FROM REGULATOR TOBURNER. (TYP).5" DROP TO PUMP SUCTIONDIFFUSER (TYP).MCCSHUTOFF VALVEIN RISER (TYP)DAS P10 GGP111/2"C W/(3)#10+#10GTO NEW MOTOR.(TYP OF 2)1/2"C W/(3)#12+#12G TOEXIST. 15A/3P BRKR INPANEL PB (TYP OF 2)LONG RADIUSELBOW AT PUMPTYPICAL ENCLOSED COMBINATIONSOFT STARTER PACKAGE EQUAL TOSQUARE D ATS22D32S6U WITHINTEGRATED BYPASS, 50A BREAKER,32A CONTACTOR W/120V COIL.RUN INDICATING LIGHT ANDMANUAL H-O-A SWITCH ON FRONTOF NEMA 1 ENCLOSURE.1/2"C W/(3)#10+#10GTO NEW 50A/3P BRKRIN PANEL PB.MECHANICAL ROOMNEW 1" MAKEUP WATER PIPINGWITH PRV STATION AND BYPASS.CONNECT TO EXIST. AIR RELEASEPIPING.PAINT ALL NEW AND EXIST. GAS PIPING INMECHANICAL ROOM SAFETY YELLOW WITH 2COATS OIL BASED SEMIGLOSS ENAMEL.CHW BUFFER GTANKGEMADD NEW 1" RPZ BFP ABOVE TOMAKEUP WATER BRANCH SERVINGBOILER EQUIPMENT. PROVIDEFUNNEL AIR GAP FITTING AT VENTAND PIPE TO NEAREST FLOOR DRAIN.ELECTRICAL ROOMPBNA ALPERMDP1MDP24000A1200AEXIST. FULLY LOUVERED 4'-0"DOORS AND 8'x3' LOUVERABOVE TO REMAIN\ FORBOILER COMBUSTION AIR ANDVENTILATION.EXIST. EXHAUST FAN ANDASSOCIATED DUCT TO REMAIN.DRIVE RAMP DOWNMAIN BUILDINGBASEMENT MECHANICAL ROOM1 DEMOLITION PLANME4.01 SCALE: 1/4" = 1'-0"EXIST. PANEL PBADD THE FOLLOWING BREAKERS:35A/3P FOR PUMP P835A/3P FOR PUMP P950A/3P FOR PUMP P1050A/3P FOR PUMP P11MDP1MDP24000A1200AMAIN BUILDINGBASEMENT MECHANICAL ROOM2 REPLACEMENT PLANME4.01 SCALE: 1/4" = 1'-0"PAINT ALL NEW AND EXIST.GAS PIPING IN MECHANICALROOM SAFETY YELLOW. 2COATS OIL BASED SEMIGLOSSENAMEL.DRIVE RAMP DOWSHEET NO.ME4.01GEXIST. ROOF ACCESS HATCHDISCONNECT AND DEMO DEDICATED OUTSIDEAIR VENTILATION UNIT AND ASSOCIATEDCONDENSING UNIT, DISCONNECT SWITCH,POWER WIRING CONNECTIONS, CONTROLSWIRING CONNECTIONS, ETC COMPLETE.GGEXIST. 5 PSI GASPIPE ON ROOFGMECHANICAL AND ELECTRICAL DEMOLITION PLAN NOTES:1. PRIOR TO DISCONNECTING OR DISASSEMBLING ANY AIR HANDLING EQUIPMENT,MEASURE AND RECORD THE STATIC PRESSURE PRODUCED IN THE SUPPLY, RETURN,AND EXHAUST DUCT MAINS FOR EACH SYSTEM WITH THE SYSTEM FAN OPERATING ATFULL SPEED. THESE READINGS ARE TO BE USED AS A REFERENCE FOR ADJUSTINGNEW EQUIPMENT AIRFLOWS. FOR VAV SYSTEMS, MAKE READINGS WITH ALL VAV BOXESCOMMANDED OPEN.2. AFTER DISCONNECTING ALL UTILITIES, REMOVE UNIT FROM CURB.3. REMOVE EXISTING GASKET MATERIAL AND DUCT TRANSITIONS AND FLEX CONNECTORSAND PREPARE FOR NEW TRANSITION WITH FLEX CONNECTOR.4. REMOVE EXISTING COUNTER-FLASHING SKIRT ON EXISTING VIBRATION PORTION OFCURB BY REMOVING ALL SCREWS AND TERMINATION BAR SECURING SKIRT TO BACKFACE OF COUNTER-FLASHING FLANGE.5. REMOVE VIBRATION ISOLATED PORTION OF THE EXISTING CURB INCLUDING THEFLOATING TOP RAIL AND THE SUPPORT SPRINGS AND SPRING HOUSINGS INTEGRALWITH THE BASE OF THE CURB.6. CUT ROOF AS REQUIRED AND REMOVE NAILER FROM CURB.7. GRIND TOP SURFACES SMOOTH WHERE SPRING HOUSINGS ARE REMOVED.8. PREPARE CURB FOR INSTALLATION OF NEW 8" HEIGHT EXTENSION OF EXISTING CURB,WITH ADAPTER TO TRANSITION DIMENSIONS AS REQUIRED TO SUIT NEW UNIT. INCLUDEA NEW 2x4 TREATED WOOD NAILER AT AN ELEVATION OF ~12" ABOVE THE EXISTINGROOF SURFACE. SECURE CURB EXTENSION TO BASE CURB WITH SELF TAPPINGSCREWS 24" ON CENTER AND WITHIN 6" OF CORNERS.DEMO ROOF CURB VIBRATION ISOLATION RAIL,SPRINGS AND HOUSINGS COMPLETE. SEEDEMOLITION PLAN NOTES.DISCONNECT AND DEMO 27.5T GAS PACKAGEDUNIT AND ASSOCIATED DISCONNECT SWITCH,GAS PIPING, POWER WIRING CONNECTIONS,CONTROLS WIRING CONNECTIONS, ETCCOMPLETE.ANNEX CLASSROOMROOF LEVEL1 MECHANICAL/ELECTRICAL DEMOLITION PLANME4.02 SCALE: 1/4" = 1'-0"NA ALPERSHEET NO.ME4.02
- Commodity Codes
-
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
DSS Chiller, Cooling Tower, a...
Bid Number: FB26251 Bid Title: DSS Chiller, Cooling Tower, and Boiler Replacement Category:
City of Winston-Salem
Bid Due: 7/07/2026
DSS Chiller, Cooling Tower, a...
Solicitation Number: 281-FB26251 Project Title: DSS Chiller, Cooling Tower, and Boiler Replacement Description:
State Government of North Carolina
Bid Due: 7/07/2026