Replacement of Metal and Single Ply Roofs
Project Information
- Bid Title
- Replacement of Metal and Single Ply Roofs
- Issuing Agency
- City of Sevierville
- Location
- Tennessee
- Published Date
- Jun 4, 2026
- Closing Date
- Jun 30, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid Title: Replacement of Metal and Single Ply Roofs
Category: General Bids Status: Open Description: RECEIPT AND OPENING OF BIDS
The City of Sevierville, Tennessee (herein called the “Owner”) invites bids on the form(s) attached hereto for REPLACEMENT OF METAL and SINGLE PLY ROOFS. The Owner will RECEIVE BIDS UNTIL 3:00 PM, JUNE 30, 2026, at Sevierville City Hall, 120 Gary Wade Boulevard, Sevierville, Tennessee, 37862 (Mailing address: P. O. Box 5500, Sevierville, Tennessee, 37864-5500). Bids will then be publicly opened and read aloud at Sevierville City Hall, 120 Gary Wade Boulevard, Sevierville, Tennessee. The envelope containing the bid must be sealed, addressed to Bob Moncrief, Project Manager, and must bear the following information:Name of Bidder
Bidder’s Address
Date and Time of Bid Opening
Bid Enclosed: City Hall Roof ReplacementNOTE: Each bidder shall submit three (3) copies of the completed bid packet or bid packet may be rejected.
The Owner may consider informal any bid not prepared and submitted in accordance with the provisions hereof and may waive any informality or reject any and all bids. Any bid received after the time and date specified shall not be considered.Publication Date/Time: 6/2/2026 12:00 AM Closing Date/Time: 6/30/2026 3:00 PM Contact Person: City of Sevierville
Public Works Department
120 Gary Wade Boulevard
P. O. Box 5500
Sevierville, TN 37864-5500
Contact: Bob Moncrief
Phone: (865) 868-1552
Email: bmoncrief@seviervilletn.orgQualifications: The Owner may make such investigations as he/she deems necessary to determine the ability of the Bidder to supply the necessary roof replacement, and the Bidder shall furnish to the Owner all such information and data for the purpose as the Owner may request. The Owner reserves the right to reject any bid if the evidence submitted by, or investigation of, such Bidder fails to satisfy the Owner that such Bidder is properly qualified to carry out the obligation of the contract by supplying the roof replacement contemplated therein. Conditional bids will not be accepted. Related Documents: - Attachment Preview
-
Sevierville City Hall - Roof Replacement120 Gary Wade Rd.Sevierville, TN 37862Owner: City of Sevierville120 Gary Wade Blvd,Sevierville, Tn 37862Engineer: Metal Roof Consultants105 Versailles DriveCary, NC 27511CORRECT SCALE WHEN PRINTED ON 24"x36" PAPERSITE MAPDRAWING INDEX100 - COVER SHEET200 - NOTES300 - NEW METAL ROOF PLAN301 - NEW MEMBRANE ROOF PLAN600 - METAL ROOF DETAILS601 - METAL ROOF DETAILS602 - METAL ROOF DETAILS603 - METAL ROOF DETAILS604 - METAL ROOF DETAILS605 - METAL ROOF DETAILS700 - MEMBRANE ROOF DETAILSCover Sheet100MRS 2500 roof panel -ASTM E 1592 test results(24 gauge panel, 16" wide, 90 degree seam, Galvalume)Purlin Space1 '-0"2'-0"2'-6"3-0"3'-6"4'-0"4'-6"5'-0"Load (psf)160.0129.2114.299.284.269.254.239.2Comments3 Test Average, SF =1.75InterpolatedInterpolatedInterpolatedInterpolatedInterpolatedInterpolated3 Test Average, SF =1.75Roof Wind Pressures -IBC 2012 -ASCE 7-10Occupancy -AssemblyRoof Slope - 4 / 12Ultimate Wind Speed - 115 mphNominal Wind Speed - 89.1 mphExposure - BComponents & Cladding Nominal Wind Pressures (PSF)Zone 1 - 13.1 psfZone 2 - 22.7 psfZone 3 - 33.6 psfPANEL PROFILESROOF PANELWALL PANELEXTERIOR FACECORRECT SCALE WHEN PRINTED ON 24"x36" PAPERNotes:1) See Hugger framing information on Sheet 200.2) Install a standard Hugger member over each existingpurlin, connected as described on Sheet 200.3) Install a new standing seam metal roof panel over the Huggers.Metal roof panels shall match style and color of the CommunityCenter as well as meet the requirements of the specificationsand these drawings.4) One Hugger over all purlin locations w/ three (3) #12-14DP3 fasteners per connection to existing purlin.5) 7/8" butyl tape sealant under all Hugger connection pointswith fasteners going through tape caulk. Contractor isresponsible for all temporary weathertightness duringconstruction as well as any interior damages caused byfaulty seals.NEW ROOF PANELFILL ALL VOIDS BETWEEN THENEW ROOF & THE OLD ROOFWITH BATT. INSULATIONNEW ROOF HUGGER12-14 DP3 (3) PER PANELEXISTING ROOF PANEL7/8" TRI BEAD TAPE SEALANTBETWEEN THE EXISTINGPANEL AND THE ROOFHUGGEREXISTING PURLINTYPICAL FASTENING PATTERN FORROOF HUGGER LAP USE #12-14 DP3TYPICAL ROOF ASSEMBLYNotes200CORRECT SCALE WHEN PRINTED ON 24"x36" PAPER160026021600SLOPE16032602160016002602SLOPE16012604LOW2602SLOPESLOPE260216021600SLOPE1604 LOW1600 HIGH26021601SLOPE16021601160116011601160126021600ROOF VALLEYROOF HIP1602SLOPE26021601160016022602SLOPE1 NEW METAL ROOF COVERING PLAN1/8" = 1'-0"16002602SLOPE260216001600SLOPE2604LOW1600MetalRoof Plan300CORRECT SCALE WHEN PRINTED ON 24"x36" PAPERBACKUP ROOF DRAINROOF DRAIN41" : 12 TYP.SLOPE1603ALL 3 SIDESTHE SAME41" : 12 TYP.SLOPE16011601REMOTE CONDENSORATTIC VENTATTIC VENT16011601ATTIC VENT1601160141" : 12 TYP.SLOPEBACKUP ROOF DRAINATTIC VENTBACKUP ROOF DRAINROOF DRAINSLOPE41" : 12 TYP.SLOPE41" : 12 TYP.1ATTIC VENT6011601BACKUP ROOF DRAINROOF DRAINROOF HATCHSLOPE41" : 12 TYP.BACKUP ROOF DRAINATTIC VENT1601160116011601NEW TPO ROOF MEMBRANESEE PAGE 700 FOR FLASHINGDETAILS1 NEW MEMBRANE ROOF COVERING PLAN1/8" = 1'-0"MembraneRoof Plan301CORRECT SCALE WHEN PRINTED ON 24"x36" PAPEREXISTING METAL TRUSSEXISTING METAL ROOF PANELSEXISTING PURLINEXISTING GUTTER TO BE REMOVEDEXISTING HAT CHANNELEXISTING VENTEXISTING MASONRYEXISTING INSULATIONEXISTING LOW EAVE CONDITIONS-5 COLORGUARD SNOW RETENTION SYSTEM INCLUDINGNON PENETRATING "VERSACLIP" RIB CLAMPS 16" O.C.CROSSMEMBER CONTINUOUS WITH EXP JOINTS,SNO-CLIP WITH RUBBER TOE 1 PER PANEL 16" O.C.4" UNFACED BATT INSULATIONNEW METAL ROOF PANELSSEALANT BETWEEN PANEL RIBSPOWDER-COATED GUTTER HANGER 32" O.C.112" DEEP CHANNEL WITH 3 4" FLANGES MADEFROM 18 GA. GALVALUME OR .063 ALUMINUM#12-14 LONG LIFE (5) PER PANELCONTINUOUS TRI BEAD TAPE SEALANTNEW GUTTER16 GA. 38" OFFSET EAVE PLATEATTACHED TO THE ROOF HUGGERW/ #12-14 x 1.25" TEK 3 @ 12" O.C.DOWNSPOUT STRAINERDOWNSPOUT OUTLET SEALED AND RIVETED TO GUTTER24 GA PREFINISHED DOWNSPOUTDOWNSPOUT STRAP 5' O.C. MAX.1 LOW EAVE DETAIL3" = 1'-0"FLOATING PANEL CLIP WITH (2) #12-14 DP3 FASTENERS4" ROOF HUGGER SET ON CONTINUOUSTRI BEAD TAPE SEALANT FASTENEDTO THE EXISTING PURLINSW/ (3) 12-14 DP3 PER PANELNEW LOW EAVE CONDITIONRoof Details600
- Commodity Codes
-
- NAICS 238160Roofing Contractors
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Project: Life Safety Upgrades South Central Correctional Facility Clifton, Wayne County, Tennessee SBC
State Government of Tennessee
Bid Due: 7/23/2026
COG2027-01 Germantown Athleti...
Project Title Release Date Pre-Bid Meeting Information Bid Opening Date Results Questions Deadline
City of Germantown