Transportation Maintenance Deltona - Replace Emergency Generator and MDP
Project Information
- Bid Title
- Transportation Maintenance Deltona - Replace Emergency Generator and MDP
- Issuing Agency
- Volusia County Schools
- Location
- Florida
- Published Date
- Jul 8, 2026
- Closing Date
- Jul 15, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Project No. 2648209
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Transportation Maintenance Deltona - Replace Emergency Generator and MDP - Project No. 2648209
Mandatory Prebid Meeting: June 25, 2026 at 10:00 AM Bid: July 15, 2026 at 1:00 PM Project Bid Documents: Plans
Project Manual
Prebid Sign-in
Addendum No. 1 issued 7/08/2026Estimate: $128,226 Consultant: Kimley-Horn and Associates, Inc.
Jeremy Demboski
(813) 620-1460Owner: VCS Project Manager
Jim Bott
(386) 947-8786Bid Status: Active - Attachment Preview
-
TRANSPORTATION/MAINTENANCEVOLUSIACOUNTY SCHOOLSDELTONAREPLACEEMERGENCYSCHOOL BOARDMEMBERSRUBEN COLONBOARD CHAIR"LEADING WITH GRACE AND RESPECT"THE SCHOOL BOARD OF VOLUSIAGENERATOR AND MDPKRISTA GOODRICHDONNA BROSEMERJAMIE HAYNESVICE BOARD CHAIRMEMBERMEMBERCOUNTY FLORIDA200 North Clara AvenueDeLand, Florida 32720VCS Project NO. 2648209JESSIE THOMPSONDR. CARMEN J. BALGOBINMEMBERSUPERINTENDENT201 N FRANKLIN STSUITE 1400TAMPA, FL 33602PHONE: 813.620.1460REGISTRY NO. 35106This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.2101 Eustace Ave, Deltona, FL 32725DESCRIPTION OF WORKREPLACE THE EXISTING 60 KW 208Y/120V GENERATOR AND THE EXISTING STANDBY ELECTRICALDISTRIBUTION SYSTEM TO PROVIDE ADDITIONAL ELECTRICAL STANDBY POWER CAPACITY FOR THE SITE. ANALTERNATE SERVICE, OF A NEW LARGER DIESEL GENERATOR FOR THE ENTIRE SITE LOCATED BY THE MAINDISTRIBUTION PANEL IN LIEU OF REPLACING THE EXISTING GENERATOR FOR THE TRANSPORTATIONBUILDING.Architect's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe Florida Building Code.ENGINEERS & CONSULTANTSELECTRICALKIMLEY-HORN201 N FRANKLIN ST, SUITE 1400TAMPA, FL 33602(813) 635 - 5555JIMMY NGUYENJIMMY.NGUYEN@KIMLEY-HORN.COMWWW.KIMLEY-HORN.COMSTRUCTURALKIMLEY-HORN11601 KEW GARDENS AVE, SUITE 200PALM BEACCH GARDENS, FL 33410(561) 840 - 0281SHEILA PREBLESHEILA.PREBLE@KIMLEY-HORN.COMWWW.KIMLEY-HORN.COMCIVILKIMLEY-HORN6876 MARWICK LANE , SUITE 350ORLANDO , FL 32827(407) 409 - 7003BLAKE WAGNERBLAKE.WAGNER@KIMLEY-HORN.COMWWW.KIMLEY-HORN.COMPROJECT SHEET INDEXSHEET NUMBERGENERALG000CIVILC300C310C400ELECTRICALE000ED100E100E500E600STRUCTURALS100SHEET NAMECOVER SHEETOVERALL EXISITNG CONDITIONS AND DEMOLITION PLANEXISITNG CONDITIONS AND DEMOLITION PLANSITE PLANELECTRICAL SYMBOLS, ABBREVIATIONS, AND NOTESELECTRCIAL DEMO SITE PLANELECTRICAL SITE PLANELECTRICAL RISER DIAGRAMELECTRICAL DETAILSGENERAL SLAB DETAILLOCATION MAPNOT TO SCALECONSTRUCTION DOCUMENTS 03/19/2025ARCH/ENGR OF RECORDJIMMY NGUYEN PE 91973DESIGNED BYJNISSUE DATE03/19/2026DRAWN BYJNJAE PROJECT NUMBER145642004SHEET TITLECOVER SHEETDRAWING NO.G00072SITE BENCHMARK #5077274GASGASEGASESITE BENCHMARK #5047372NOT FOR CONSTRUCTIONNORTH7372717170SITE BENCHMARK #5026876 MARWICK LANESUITE 350ORLANDO, FL 32827PHONE: (407) 602-0423REGISTRY No. 35106This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.PRELIMINARYFOR REVIEW ONLYNOT FOR RECORDATION PURPOSESENGINEERPE NO.DATESITE BENCHMARK #50169ARCH/ENGR OF RECORDDESIGNED BYBJWDRAWN BYNDFISSUE DATE02/18/2026AE PROJECT NUMBER145642004SHEET TITLEOVERALL EXISTINGCONDITIONS ANDDEMOLITION PLANDRAWING NO.C300GASGASGASEESFSFSFSF72SFNOT FOR CONSTRUCTIONNORTH6876 MARWICK LANESUITE 350ORLANDO, FL 32827PHONE: (407) 602-0423REGISTRY No. 35106This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.PRELIMINARYFOR REVIEW ONLYNOT FOR RECORDATION PURPOSESENGINEERPE NO.DATEARCH/ENGR OF RECORDDESIGNED BYBJWDRAWN BYNDFISSUE DATE02/18/2026AE PROJECT NUMBER145642004SHEET TITLEEXISTING CONDITIONSAND DEMOLITION PLANDRAWING NO.C310CONCRETE SIDEWALK DETAILNOT FOR CONSTRUCTIONNORTH6876 MARWICK LANESUITE 350ORLANDO, FL 32827PHONE: (407) 602-0423REGISTRY No. 35106This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.PRELIMINARYFOR REVIEW ONLYNOT FOR RECORDATION PURPOSESENGINEERPE NO.DATEARCH/ENGR OF RECORDDESIGNED BYBJWDRAWN BYNDFISSUE DATE02/18/2026AE PROJECT NUMBER145642004SHEET TITLESITE PLANDRAWING NO.C400SYSTEM SYMBOLSEQUIPMENTSMSHOAMOTOR RATED SWITCHMOTOR RATED HAND-OFF-AUTO SWITCHEMERGENCY POWER OFF SWITCH, MUSHROOM TYPEDISCONNECT, HEAVY DUTY, NON-FUSIBLEDISCONNECT, HEAVY DUTY, FUSIBLEMAGNETIC MOTOR STARTERCOMBINATION MOTOR STARTER & DISCONNECTVFDVARIABLE FREQUENCY DRIVEW ALLW ALLTELECTRICAL PANEL, SURFACE MOUNTEDELECTRICAL PANEL, FLUSH MOUNTEDTRANSFORMERDPW ALLACWH-1 AC11W ALLAUDIO/VIDEODISTRIBUTION PANELBOARDINVERTEREQUIPMENT CALLOUTAUXILIARY SYSTEM CABINETSAUDIO SPEAKERTELECOMMUNICATION DEVICES##DATA OUTLET, DASH INDICATES 42" AFF#TELEPHONE OUTLET##WAPCRDATA OUTLET, CEILING MOUNTEDDATA OUTLET, IN FLOOR BOX, REUSE DEMOLISHED AMF50 FLOOR BOX HOUSING WHENAVAILABLE. IF NOT, PURCHASE SAME OR EQUIVALENT.WIRELESS ACCESS POINT (WAP)MOUNTING(UON)CARD READERFVMTELECOMMUNICATION DEVICE TYPE DESIGNATION LEGENDX = TYPE, # = NUMBER OF DATA DROPSE000ED100E100E500E600ELECTRICAL SHEET LIST#SHEET NAMEELECTRICAL SYMBOLS, ABBREVIATIONS, AND NOTESELECTRCIAL DEMO SITE PLANELECTRICAL SITE PLANELECTRICAL RISER DIAGRAMELECTRICAL DETAILSELECTRICAL SYMBOLSCONDUIT AND RACEWAYCONDUIT RUN IN OR ON CEILING OR WALL.CONDUIT RUN IN FLOOR, UNDER FLOOR, OR UNDERGROUND.MARKS INDICATE QTY OF CONDUCTORS IN CONDUIT EXCLUDING GROUND. NO MARKSINDICATE (2) CONDUCTORS. ADD GROUND PER NEC FOR EMT & NON-METALLIC CONDUIT.LONG MARK INDICATES GROUND FOR ISOLATED GROUNDING SYSTEM. SIZE PER NEC.BRANCH CIRCUIT (DIAGRAMMATIC)LA-1LA-[1,3,5]ON HA-1HOMERUN INDICATING PANEL AND CIRCUIT NUMBER.HOMERUN WITH CIRCUIT NUMBER IN BRACKETS INDICATING MULTI-PHASE LOAD."ON" INDICATES CIRCUITING SPLIT AT DIFFERENT LOCATIONSCONDUIT DOWN.CONDUIT UP.CONDUIT STUB AND CAP.POWER DEVICESDUPLEX CONVENIENCE OUTLET, +18" AFF (TYPICAL).MOUNTING(UON)W, +18" AFFDUPLEX CONVENIENCE OUTLET, COUNTER HEIGHT +42" AFF (TYPICAL).W, FVMHCONVENIENCE OUTLET W/ GFCI PROTECTION.W, +18" AFFWPIGMONCONVENIENCE OUTLET W/ GFCI PROTECTION & WEATHER PROOF-IN-USE COVER.DUPLEX CONVENIENCE OUTLET W/ DEDICATED CIRCUIT & ISOLATED GROUND.DUPLEX CONVENIENCE OUTLET FOR MONITOR. COORDINATE WITH ARCH/OWNER.DUPLEX CONVENIENCE OUTLET WITH INTEGRAL USB CHARGING PORTS.W, +18" AFFW, +18" AFFW, +60" AFFW, +18" AFFEWCREFDISPDUPLEX CONVENIENCE OUTLET FOR ELECTRIC WATER COOLERDUPLEX CONVENIENCE OUTLET W/ DEDICATED CIRCUIT FOR REFRIGERATOR.DUPLEX CONVENIENCE OUTLET W/ DEDICATED CIRCUIT FOR WASTE DISPOSAL.DOUBLE DUPLEX CONVENIENCE OUTLET.W, +30" AFFW, +42" AFFW, +18" AFFW, +18" AFFDUPLEX CONVENIENCE OUTLET, CEILING MOUNTED, FVMH.C, FVMHQUAD RECEPTACLE IN FLOOR BOX.FLDUPLEX RECEPTACLE IN FLOOR BOX.FLJ USESPECIAL PURPOSE OUTLET, NEMA CONFIGURATION AND VOLTAGE AS NOTED.JUNCTION BOX, SPECIFIC USE AS NOTED.W, FVMHW, FVMHABBREVIATIONSACAFFANSIAWGBLDGCUDIAEXEMTENTETCIEEEGECGFCIkWKVAMCMHNECNEMANFPANORMNTSOCPPHPWRPVCSESSPDSWBDTYPUBCULUONUPSWXFMRWPARMORED CABLEABOVE FINISHED FLOORAMERICAN NATIONAL STANDARDS INSTITUTEAMERICAN WIRE GAUGEBUILDINGCOPPERDIAMETEREXISTING TO REMAIN. PROVIDE WHITE TRIM FOR NON-WHITE TRIM DEVICESELECTRIC METAL TUBINGELECTRIC NON-METALLIC TUBINGETCETERAINSTITUTE FOR ELECTRONIC AND ELECTRICAL ENGINEERSGROUNDING ELECTRODE CONDUCTORGROUND FAULT CIRCUIT INTERRUPTKILOWATTKILOVOLT-AMPSMETAL CLADMOUNTING HEIGHTNATIONAL ELECTRICAL CODENATIONAL ELECTRIC MANUFACTURERS ASSOCIATIONNATIONAL FIRE PROTECTION AGENCYNORMALNOT TO SCALEOVER CURRENT PROTECTIONPHASEPOWERPOLYVINYL CHLORIDESERVICE ENTRANCE SECTIONSURGE PROTECTION DEVICESWITCHBOARDTYPICALUNIFORM BUILDING CODEUNDERWRITERS LABORATORYUNLESS NOTED OTHERWISEUNINTERRUPTED POWER SUPPLYWIRETRANSFORMERWEATHER PROOFGENERAL NEW NOTES:1.FURNISH ALL LABOR, MATERIALS, TOOLS, ACCESSORIES, ETC. REQUIRED FOR A COMPLETE WORKING ELECTRICAL SYSTEM.2.ALL ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL CODES AND ORDINANCES, AS WELL ASALL CURRENT STANDARDS, CODES AND PRACTICES AS REQUIRED BY NEC 2020, NEMA, ANSI, NFPA, UBC, UL, IEEE, AND UTILITYCOMPANY STANDARDS.3.ALL EQUIPMENT, MATERIALS, AND WORK SHOWN ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTING OR NOTED OTHERWISE ONOTHER SHEETS.4.VERIFY EXACT LOCATION OF ALL RECEPTACLES ABOVE OR ADJACENT TO COUNTERS, FIXTURES, MIRRORS OUTDOOR FIXTURESAND MOUNTING HEIGHTS AND LOCATIONS OF ALL FIXTURES AND BOXES PRIOR TO ROUGH-IN. NO EXTRA COSTS WILL BE ALLOWEDFOR FAILURE TO COMPLY.5.ANY POWER OUTAGE OF ANY CIRCUIT SHALL BE APPROVED BY THE OWNER IN WRITING A MINIMUM OF TWO WEEKS PRIOR TOOUTAGE. ALL OUTAGES SHALL BE DONE EXACTLY WHEN DETERMINED BY THE OWNER AND DONE BEFORE OR AFTER WORKINGHOURS AND ON WEEKENDS. NO SINGLE OUTAGE SHALL REQUIRE MORE THAN 4 HOURS. PROVIDE TEMPORARY POWER, HEAT ANDCOOLING AS REQUIRED DURING OUTAGE.6.DUE TO THE REQUIREMENTS TO INTERFACE WITH EXISTING FACILITIES AND UTILITIES, IT IS REQUIRED THAT THE CONTRACTORVISIT THE SITE TO DETERMINE EXISTING CONDITIONS PRIOR TO BID.7.PRIOR TO PURCHASE OF ANY PANEL, PROTECTIVE DEVICES, SWITCH, STARTER, CONDUIT, WIRE, ETC., TO FEED ANY PIECE OFMECHANICAL EQUIPMENT, VERIFY THE VOLTAGE, PHASE, AND LOAD OF THAT ITEM IN THE FIELD AND/OR WITH THE PARTICULARENTITY INVOLVED IN FURNISHING THE ITEM SUCH THAT THE PROPER SIZE & RATING OF THE MATERIALS ARE PURCHASED. NOEXTRAS WILL BE ALLOWED FOR FAILURE TO COMPLY. THIS APPLIES TO ALL EQUIPMENT UNDER OTHER SECTIONS & BY THEOWNER.8.ALL RECEPTACLES SHALL MATCH THE MALE PLUG CONNECTOR OF ALL EQUIPMENT PROVIDED. VERIFY PRIOR TO PURCHASE. SEEGENERAL NOTE 7.9.PULL ROPES: PROVIDE 300 POUND PULL WIRE OR NYLON EQUIVALENT IN ALL INTERIOR EMPTY CONDUIT RUNS. PROVIDE 1/4" DIANYLON PULL ROPE IN EACH EMPTY EXTERIOR CONDUIT OR DUCT.10. COORDINATE WITH MECHANICAL CONTRACTOR TO AVOID CONFLICTS BETWEEN DUCT WORK, SUPPLY & EXHAUST DIFFUSERS,LIGHTING, SOUND SYSTEMS, AND FIRE ALARM SYSTEM FIXTURES.11. ELECTRICAL CONTRACTOR SHALL GUARANTEE THE ELECTRICAL WORK TO BE FREE FROM DEFECTS IN MATERIALS ANDWORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF FINAL ACCEPTANCE.12. VERIFY THE EXACT LOCATION AND ELEVATION OF ALL ELECTRICAL EQUIPMENT PRIOR TO ROUGH-IN. FINAL CONNECTIONS OFEQUIPMENT SHALL BE PER MANUFACTURERS APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. THE ELECTRICALCONTRACTOR SHALL PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED.13. ORDER AND/OR RELEASE ORDERED MATERIALS PROMPTLY AFTER SUBMITTAL APPROVAL. NO SUBSTITUTIONS OR ALTERNATEMETHODS OF INSTALLATION WILL BE ACCEPTED FOR FAILURE TO ORDER MATERIALS IN A TIMELY FASHION.14. OBTAIN WRITTEN APPROVAL FROM THE ENGINEER OF ALL SHOP DRAWINGS AND MANUFACTURERS DATA FOR PANEL BOARDS,TRANSFORMERS, WIRING DEVICES, ETC. BEFORE RELEASING ORDERED MATERIALS. SUBMITTAL DATA SHALL INDICATE THAT THECONTRACTOR HAS REVIEWED THE INFORMATION THEREIN AND THAT THE PROPOSED EQUIPMENT WILL MEET THE PHYSICALCONSTRAINTS AT THE JOB SITE. ANY SUBSTITUTIONS SHALL BE OF THE EQUIVALENT OR BETTER QUALITY THAN THE SPECIFIEDCOMPONENTS.15. TYPE MC OR TYPE AC CABLE SHALL ONLY BE USED WITH THE SPECIFIC WRITTEN PERMISSION OF THE PROGRAM/PROJECTMANAGER. ENT TYPE CONDUIT IS NOT ALLOWED.16. CONDUIT/CONDUCTOR RUNS SHOWN ARE DIAGRAMMATICAL ONLY. THE BEST FINAL CONDUIT ROUTING SHALL BE AS DETERMINEDBY THE ELECTRICAL CONTRACTOR AT THE TIME OF CONSTRUCTION.17. ALL WIRE SHALL BE COPPER. MINIMUM SIZE FOR POWER WIRING SHALL BE #10 AWG. STRANDED UNLESS OTHERWISE NOTED.MINIMUM SIZE FOR CONTROL WIRING SHALL BE #14 AWG.18. PROVIDE ALL PANEL BOARDS WITH TYPED DIRECTORIES INSTALLED UNDER A CLEAR PLASTIC COVER. SUBMIT DIRECTORYINFORMATION TO THE OWNER FOR APPROVAL PRIOR TO FINALIZATION.19. SERIES RATING OF UPSTREAM OR DOWNSTREAM CIRCUIT BREAKERS OR FUSES IS PROHIBITED. ONLY FULLY RATED SYSTEMCOMPONENTS WILL BE ACCEPTED.20. PROVIDE ALL TRENCHING, EXCAVATION, BACK FILLING, SHORING, PUMPING, COMP ACTION TEST ETC. THAT ARE REQUIRED FORTHE SCOPE OF ELECTRICAL WORK.21. ALL PANEL BOARDS, SWITCHES, MOTOR STARTERS, AND SWITCHBOARD CIRCUIT BREAKERS SHALL HAVE ENGRAVED MICARTANAMEPLATES.22. ALL CIRCUITS THAT SHARE A NEUTRAL SHALL BE PROVIDED WITH MULTIPOLE BREAKER.23. PROVIDE CIRCUIT BREAKER LOCK LOCKED IN THE 'ON' POSITION FOR ALL CIRCUITS SERVING EMERGENCY LIGHTING.24. ALL EMERGENCY FIXTURES SHALL BE ALWAYS ON AS NIGHT LIGHTS AND WIRED TO THE UNSWITCHED HOT LEG OF THE CIRCUIT.25. ALL ANALOG INSTRUMENTATION WIRING SHALL BE SHIELDED.26. IN ADDITION TO SURFACE RACEWAY AND/OR FLOOR MOUNTED OUTLET BOXES AND POWER POLES INDICATED ON ELECTRICALDRAWINGS, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CABLE TRAY AND FLUSH MOUNTED OUTLET BOXES/BACK BOXESAND ASSOCIATED CONDUIT FOR ALL TELECOMMUNICATIONS OUTLETS (INCLUDING PA/MASTER CLOCK/SOUND SYSTEMS,CATV/VIDEO SYSTEMS, AND SECURITY SYSTEMS) ON THIS PROJECT.Compliance DataThe following are the primary codes under which this project isdesigned and permittedCODEAPPLICABLE CODE BOOK AND YEARBUILDING CODEELECTRICALENERGYACCESSIBILITY2023 FBC (IBC 2018 with Amendments)2020 National Electrical CodeIECC 2021 with Amendments2021 IBC - Chapter 11FIRE ALARM2023 Florida Fire Prevention Code201 N FRANKLIN STSUITE 1400TAMPA, FL 33602PHONE: 813.620.1460REGISTRY NO. 35106This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.JIMMY NGUYENPE 91973ARCH/ENGR OF RECORDDESIGNED BYJNDRAWN BYJNJISSUE DATE03/19/2026AE PROJECT NUMBER145642004SHEET TITLEELECTRICAL SYMBOLS,ABBREVIATIONS, ANDNOTESDRAWING NO.E000
- Commodity Codes
-
- NAICS 238210Electrical Contractors and Other Wiring Installation Contractors
- NAICS 335312Motor and Generator Manufacturing
- NAICS 811310Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Security Enhancements & Emerg...
Project ID: 25-8391 Title: Security Enhancements & Emergency Generator Immokalee Airport (IMM) Addenda:
Collier County
Bid Due: 7/31/2026
Number Title Status Due Date Contact 26-908 Generator Replacement Open 9/3/2026 3:00:00 PM
County of Lake
Bid Due: 9/03/2026