Spruce Creek Elementary - Replace 60 Ton Chiller
Project Information
- Bid Title
- Spruce Creek Elementary - Replace 60 Ton Chiller
- Issuing Agency
- Volusia County Schools
- Location
- Florida
- Published Date
- Feb 19, 2026
- Closing Date
- Mar 11, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Project No. 2648251
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Spruce Creek Elementary - Replace 60 Ton Chiller - Project No. 2648251
Mandatory Prebid Meeting: February 18, 2026 at 2:00 PM Bid: March 11, 2026 at 1:00 PM Project Bid Documents: Plans
Project Manual
Prebid Sign-in SheetsEstimate: $308,890 Consultant: Kimley-Horn and Associates, Inc.
Kevin Peterson
(813) 553-3701Owner: VCS Project Manager
Robert Larkin
(386) 947-8786Bid Status: Active - Attachment Preview
-
VOLUSIA SPRUCE CREEK ELEMENTARYCOUNTY SCHOOLS"LEADING WITH GRACE AND RESPECT"REPLACE 60 TON CHILLERTHE SCHOOL BOARD OF VOLUSIACOUNTY FLORIDA200 North Clara AvenueDeLand, Florida 32720VCS Project NO. 2648251642 TAYLOR RD, PORT ORANGE, FL 32127SCHOOL BOARDMEMBERSRUBEN COLONKRISTA GOODRICHDONNA BROSEMERJAMIE HAYNESJESSIE THOMPSONDR. CARMEN J. BALGOBINBOARD CHAIRBOARD VICE CHAIRBOARD MEMBERBOARD MEMBERBOARD MEMBERSUPERINTENDENT200 S. ORANGE AVENUESUITE 600ORLANDO, FL 32801PHONE: 407.898.1511REGISTRY NO. 351062025 ©This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.DESCRIPTION OF WORKREPLACE EXISTING 55 TON AIR-COOLED SCROLL CHILLER SERVING BUILDING 13 IN KIND WITH NEW 60 TON AIR-COOLEDCHILLER. UPDATE CONTROL COMPONENTS, SEQUENCES, AND GRAPHICS FOR NEW CHILLER.Architect's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe Florida Building Code.ENGINEERS & CONSULTANTSMECHANICALKIMLEY-HORN, AND ASSOCIATES, INC.201 N FRANKLIN ST, SUITE 1400TAMPA, FL 33602(813) 556 - 6670JEREMY DEMBOSKIJEREMY.DEMBOSKI@KIMLEY-HORN.COMWWW.KIMLEY-HORN.COMELECTRICALKIMLEY-HORN, AND ASSOCIATES, INC.201 N FRANKLIN ST, SUITE 1400TAMPA, FL 33602(813) 635 - 5555JIMMY NGUYENJIMMY.NGUYEN@KIMLEY-HORN.COMWWW.KIMLEY-HORN.COMLOCATION MAP601289.xxxxxxxxxxxxxxxxxxxx891.9021.65231.56901.74018.3176.9PROJECT LOCATION2.3570xx85190.407.9NOT TO SCALEPROJECT SHEET INDEXSHEET NUMBERCoordinationG001COVER SHEETSHEET NAMEELECTRICALE000E001E100E101E501ELECTRICAL SYMBOLS, ABBREVIATIONS, AND NOTESELECTRICAL SPECIFICATIONSELECTRICAL SITE PLANPOWER PLANELECTRICAL RISER DIAGRAMS & SCHEDULESMECHANICALM000M100M101M102M501M502MECHANICAL SYMBOLS, ABBREVIATIONS, AND NOTESSITE PLANMECHANICAL DEMO PLANMECHANICAL NEW PLANMECHANICAL PIPING DIAGRAMS AND DETAILSMECHANICAL CONTROLSCONSTRUCTION DOCUMENTS - 11/18/2025ARCH/ENGR OF RECORDJEREMY DEMBOSKIPE 94304DESIGNED BYKJPDRAWN BYSRMISSUE DATE11/18/2025AE PROJECT NUMBER145642001SHEET TITLECOVER SHEETDRAWING NO.G001EQUIPMENTSMSHOAMOTOR RATED SWITCHMOTOR RATED HAND-OFF-AUTO SWITCHEMERGENCY POWER OFF SWITCH, MUSHROOM TYPEDISCONNECT, HEAVY DUTY, NON-FUSIBLEDISCONNECT, HEAVY DUTY, FUSIBLEMAGNETIC MOTOR STARTERCOMBINATION MOTOR STARTER & DISCONNECTVFDVARIABLE FREQUENCY DRIVEWALLWALLTELECTRICAL PANEL, SURFACE MOUNTEDELECTRICAL PANEL, FLUSH MOUNTEDTRANSFORMERDPDISTRIBUTION PANELBOARDWALLACWH-1 AC11INVERTEREQUIPMENT CALLOUTWALLAUDIO/VIDEOSAUXILIARY SYSTEM CABINETAUDIO SPEAKERMOUNTING(UON)FVMTELECOMMUNICATION DEVICES##DATA OUTLET, DASH INDICATES 42" AFF#TELEPHONE OUTLET##WAPDATA OUTLET, CEILING MOUNTEDDATA OUTLET, IN FLOOR BOX, REUSE DEMOLISHED AMF50 FLOOR BOX HOUSING WHENAVAILABLE. IF NOT, PURCHASE SAME OR EQUIVALENT.WIRELESS ACCESS POINT (WAP)CRCARD READERTELECOMMUNICATION DEVICE TYPE DESIGNATION LEGENDX = TYPE, # = NUMBER OF DATA DROPSE000E001E100E101E501ELECTRICAL SHEET LIST#SHEET NAMEELECTRICAL SYMBOLS, ABBREVIATIONS, AND NOTESELECTRICAL SPECIFICATIONSELECTRICAL SITE PLANPOWER PLANELECTRICAL RISER DIAGRAMS & SCHEDULESCompliance DataThe following are the primary codes under which this project isdesigned and permittedCODEAPPLICABLE CODE BOOK AND YEARBUILDING CODEELECTRICALENERGYACCESSIBILITY2023 FBC Eighth Edition2020 National Electrical Code2023 FBC Energy Conservation Eighth Edition2023 FBC - Chapter 11FIRE ALARM2023 Florida Fire Prevention Code, Eighth EditionELECTRICAL SYMBOLSCONDUIT AND RACEWAYCONDUIT RUN IN OR ON CEILING OR WALL.CONDUIT RUN IN FLOOR, UNDER FLOOR, OR UNDERGROUND.MARKS INDICATE QTY OF CONDUCTORS IN CONDUIT EXCLUDING GROUND. NO MARKSINDICATE (2) CONDUCTORS. ADD GROUND PER NEC FOR EMT & NON-METALLIC CONDUIT.LONG MARK INDICATES GROUND FOR ISOLATED GROUNDING SYSTEM. SIZE PER NEC.BRANCH CIRCUIT (DIAGRAMMATIC)LA-1LA-[1,3,5]ON HA-1HOMERUN INDICATING PANEL AND CIRCUIT NUMBER.HOMERUN WITH CIRCUIT NUMBER IN BRACKETS INDICATING MULTI-PHASE LOAD."ON" INDICATES CIRCUITING SPLIT AT DIFFERENT LOCATIONSCONDUIT DOWN.CONDUIT UP.CONDUIT STUB AND CAP.POWER DEVICESDUPLEX CONVENIENCE OUTLET, +18" AFF (TYPICAL).MOUNTING(UON)W, +18" AFFDUPLEX CONVENIENCE OUTLET, COUNTER HEIGHT +42" AFF (TYPICAL).W, FVMHCONVENIENCE OUTLET W/ GFCI PROTECTION.W, +18" AFFWPIGMONCONVENIENCE OUTLET W/ GFCI PROTECTION & WEATHER PROOF-IN-USE COVER.DUPLEX CONVENIENCE OUTLET W/ DEDICATED CIRCUIT & ISOLATED GROUND.DUPLEX CONVENIENCE OUTLET FOR MONITOR. COORDINATE WITH ARCH/OWNER.DUPLEX CONVENIENCE OUTLET WITH INTEGRAL USB CHARGING PORTS.W, +18" AFFW, +18" AFFW, +60" AFFW, +18" AFFEWCREFDISPDUPLEX CONVENIENCE OUTLET FOR ELECTRIC WATER COOLERDUPLEX CONVENIENCE OUTLET W/ DEDICATED CIRCUIT FOR REFRIGERATOR.DUPLEX CONVENIENCE OUTLET W/ DEDICATED CIRCUIT FOR WASTE DISPOSAL.DOUBLE DUPLEX CONVENIENCE OUTLET.W, +30" AFFW, +42" AFFW, +18" AFFW, +18" AFFDUPLEX CONVENIENCE OUTLET, CEILING MOUNTED, FVMH.C, FVMHQUAD RECEPTACLE IN FLOOR BOX.FLDUPLEX RECEPTACLE IN FLOOR BOX.FLJ USESPECIAL PURPOSE OUTLET, NEMA CONFIGURATION AND VOLTAGE AS NOTED.JUNCTION BOX, SPECIFIC USE AS NOTED.W, FVMHW, FVMHACAFFANSIAWGBLDGCUDIAEXEMTENTETCIEEEGECGFCIkWKVAMCMHNECNEMANFPANORMNTSOCPPHPWRPVCSESSPDSWBDTYPUBCULUONUPSWXFMRWPABBREVIATIONSARMORED CABLEABOVE FINISHED FLOORAMERICAN NATIONAL STANDARDS INSTITUTEAMERICAN WIRE GAUGEBUILDINGCOPPERDIAMETEREXISTING TO REMAIN. PROVIDE WHITE TRIM FOR NON-WHITE TRIM DEVICESELECTRIC METAL TUBINGELECTRIC NON-METALLIC TUBINGETCETERAINSTITUTE FOR ELECTRONIC AND ELECTRICAL ENGINEERSGROUNDING ELECTRODE CONDUCTORGROUND FAULT CIRCUIT INTERRUPTKILOWATTKILOVOLT-AMPSMETAL CLADMOUNTING HEIGHTNATIONAL ELECTRICAL CODENATIONAL ELECTRIC MANUFACTURERS ASSOCIATIONNATIONAL FIRE PROTECTION AGENCYNORMALNOT TO SCALEOVER CURRENT PROTECTIONPHASEPOWERPOLYVINYL CHLORIDESERVICE ENTRANCE SECTIONSURGE PROTECTION DEVICESWITCHBOARDTYPICALUNIFORM BUILDING CODEUNDERWRITERS LABORATORYUNLESS NOTED OTHERWISEUNINTERRUPTED POWER SUPPLYWIRETRANSFORMERWEATHER PROOFGENERAL NEW NOTES:A.FURNISH ALL LABOR, MATERIALS, TOOLS, ACCESSORIES, ETC. REQUIRED FOR A COMPLETE WORKINGELECTRICAL SYSTEM.B.ALL ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL CODES ANDORDINANCES, AS WELL AS ALL CURRENT STANDARDS, CODES AND PRACTICES AS REQUIRED BY NEC2017, NEMA, ANSI, NFPA, UBC, UL, IEEE, AND UTILITY COMPANY STANDARDS.C.ALL EQUIPMENT, MATERIALS, AND WORK SHOWN ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTINGOR NOTED OTHERWISE ON OTHER SHEETS.D.ANY POWER OUTAGE OF ANY CIRCUIT SHALL BE APPROVED BY THE OWNER IN WRITING A MINIMUM OFTWO WEEKS PRIOR TO OUTAGE. ALL OUTAGES SHALL BE DONE EXACTLY WHEN DETERMINED BY THEOWNER AND DONE BEFORE OR AFTER WORKING HOURS AND ON WEEKENDS. NO SINGLE OUTAGE SHALLREQUIRE MORE THAN 4 HOURS. PROVIDE TEMPORARY POWER, HEAT AND COOLING AS REQUIREDDURING OUTAGE.E.DUE TO THE REQUIREMENTS TO INTERFACE WITH EXISTING FACILITIES AND UTILITIES, IT IS REQUIREDTHAT THE CONTRACTOR VISIT THE SITE TO DETERMINE EXISTING CONDITIONS PRIOR TO BID.F.PRIOR TO PURCHASE OF ANY PANEL, PROTECTIVE DEVICES, SWITCH, STARTER, CONDUIT, WIRE, ETC., TOFEED ANY PIECE OF MECHANICAL EQUIPMENT, VERIFY THE VOLTAGE, PHASE, AND LOAD OF THAT ITEM INTHE FIELD AND/OR WITH THE PARTICULAR ENTITY INVOLVED IN FURNISHING THE ITEM SUCH THAT THEPROPER SIZE & RATING OF THE MATERIALS ARE PURCHASED. NO EXTRAS WILL BE ALLOWED FORFAILURE TO COMPLY. THIS APPLIES TO ALL EQUIPMENT UNDER OTHER SECTIONS & BY THE OWNER.G.PULL ROPES: PROVIDE 300 POUND PULL WIRE OR NYLON EQUIVALENT IN ALL INTERIOR EMPTY CONDUITRUNS. PROVIDE 1/4" DIA NYLON PULL ROPE IN EACH EMPTY EXTERIOR CONDUIT OR DUCT.H.COORDINATE WITH MECHANICAL CONTRACTOR TO AVOID CONFLICTS BETWEEN DUCT WORK, SUPPLY &EXHAUST DIFFUSERS, LIGHTING, SOUND SYSTEMS, AND FIRE ALARM SYSTEM FIXTURES.I.ELECTRICAL CONTRACTOR SHALL GUARANTEE THE ELECTRICAL WORK TO BE FREE FROM DEFECTS INMATERIALS AND WORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF FINAL ACCEPTANCE.J.VERIFY THE EXACT LOCATION AND ELEVATION OF ALL ELECTRICAL EQUIPMENT PRIOR TO ROUGH-IN.FINAL CONNECTIONS OF EQUIPMENT SHALL BE PER MANUFACTURERS APPROVED WIRING DIAGRAMS,DETAILS, AND INSTRUCTIONS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE MATERIALS ANDEQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED.NOTE: COORDINATE LUMINAIRE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS.K.ORDER AND/OR RELEASE ORDERED MATERIALS PROMPTLY AFTER SUBMITTAL APPROVAL. NOSUBSTITUTIONS OR ALTERNATE METHODS OF INSTALLATION WILL BE ACCEPTED FOR FAILURE TO ORDERMATERIALS IN A TIMELY FASHION.L.OBTAIN WRITTEN APPROVAL FROM THE ENGINEER OF ALL SHOP DRAWINGS AND MANUFACTURERS DATAFOR PANEL BOARDS, TRANSFORMERS, WIRING DEVICES, ETC. BEFORE RELEASING ORDERED MATERIALS.SUBMITTAL DATA SHALL INDICATE THAT THE CONTRACTOR HAS REVIEWED THE INFORMATION THEREINAND THAT THE PROPOSED EQUIPMENT WILL MEET THE PHYSICAL CONSTRAINTS AT THE JOB SITE. ANYSUBSTITUTIONS SHALL BE OF THE EQUIVALENT OR BETTER QUALITY THAN THE SPECIFIED COMPONENTS.M.TYPE MC OR TYPE AC CABLE SHALL ONLY BE USED WITH THE SPECIFIC WRITTEN PERMISSION OF THEPROGRAM/PROJECT MANAGER. ENT TYPE CONDUIT IS NOT ALLOWED.N.CONDUIT/CONDUCTOR RUNS SHOWN ARE DIAGRAMMATICAL ONLY. THE BEST FINAL CONDUIT ROUTINGSHALL BE AS DETERMINED BY THE ELECTRICAL CONTRACTOR AT THE TIME OF CONSTRUCTION.O.ALL WIRE SHALL BE COPPER. MINIMUM SIZE FOR POWER WIRING SHALL BE #10 AWG. STRANDED UNLESSOTHERWISE NOTED. MINIMUM SIZE FOR CONTROL WIRING SHALL BE #14 AWG.P.PROVIDE ALL PANEL BOARDS WITH TYPED DIRECTORIES INSTALLED UNDER A CLEAR PLASTIC COVER.SUBMIT DIRECTORY INFORMATION TO THE OWNER FOR APPROVAL PRIOR TO FINALIZATION.Q.SERIES RATING OF UPSTREAM OR DOWNSTREAM CIRCUIT BREAKERS OR FUSES IS PROHIBITED. ONLYFULLY RATED SYSTEM COMPONENTS WILL BE ACCEPTED.R.ALL PANEL BOARDS, SWITCHES, MOTOR STARTERS, AND SWITCHBOARD CIRCUIT BREAKERS SHALL HAVEENGRAVED MICARTA NAMEPLATES.S.ALL CIRCUITS THAT SHARE A NEUTRAL SHALL BE PROVIDED WITH MULTIPOLE BREAKER.200 S. ORANGE AVENUESUITE 600ORLANDO, FL 32801PHONE: 407.898.1511REGISTRY NO. 351062025 ©This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.JIMMY NGUYENPE 91973ARCH/ENGR OF RECORDDESIGNED BYJNDRAWN BYSRMISSUE DATE11/18/2025AE PROJECT NUMBER145642001SHEET TITLEELECTRICAL SYMBOLS,ABBREVIATIONS, AND NOTESDRAWING NO.E000PART ONE - GENERAL1.1. THE WORK: ALL WORK SHALL BE NEW UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALLPROVIDE THE WORK SHOWN ON THE DRAWINGS AND SPECIFIED FOR ITS INDIVIDUALSECTIONS OF WORK. THE WORD "WORK" IS DEFINED AS ALL LABOR, TRANSPORTATION,MATERIAL, EQUIPMENT, TOOLS, INSTALLATION, SUPERVISION AND ANY OTHER INCIDENTALITEMS OR SERVICES NECESSARY FOR THE PROPER INSTALLATION AND OPERATION OF THECOMPLETE SYSTEMS, WHICH SHALL BE PROVIDED BY THIS CONTRACTOR WHETHER OR NOTSPECIFICALLY INDICATED OR NOTED.1.2. RESPONSIBILITY: THIS CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACTIONS OF ITSPERSONNEL, SUPPLIERS, AND SUB-CONTRACTORS. THIS CONTRACTOR SHALL BERESPONSIBLE FOR THE PERFORMANCE OF ALL WORK AS MAY BE REQUIRED TOACCOMMODATE OR SUPPORT THE ELECTRICAL WORK. EXAMPLES: PAINTING, STRUCTURALSUPPORTS, CUTTING AND PATCHING, EXCAVATION AND BACKFILL, CONCRETE PADS, ROOFJACKS, ETC. REQUIRING THIS CONTRACTOR'S ENGAGEMENT OF APPROPRIATE TRADES TOPERFORM SUCH WORK FOR THE PROPER INSTALLATION AND OPERATION OF COMPLETEELECTRICAL SYSTEMS.1.3. MINIMUM REQUIREMENTS: THESE SPECIFICATIONS ESTABLISH THE MINIMUM REQUIREMENTSFOR THE WORK AND MATERIALS, EQUIPMENT AND METHODS TO BE PROVIDED. THEDRAWINGS MAY INDICATE REQUIREMENTS WHICH EXCEED THESE MINIMUMS.1.4. GENERAL CONDITIONS: ALL GENERAL CONDITIONS, SPECIAL REQUIREMENTS OR GENERALREQUIREMENTS OF THE CONSTRUCTION SPECIFICATIONS ARE MADE PART OF THISSPECIFICATION AND HAVE THE SAME FORCE AND EFFECT AS IF COMPLETELY REPRODUCED.1.5. DEFINITIONS:AHJ: AUTHORITY HAVING JURISDICTION.ASSEMBLY: AN INSTALLATION OR SYSTEM OF MULTIPLE COMPONENTS REQUIRING MULTIPLECONNECTIONS. (EXAMPLES: TRASH COMPACTOR, MOTORIZED DOOR, HVAC SPLIT SYSTEM,ETC.).EQUAL: ACCEPTED BY THE ENGINEER AS EQUAL.FF&E: FURNISHINGS, FIXTURES AND EQUIPMENT - PROVIDED BY OTHERS AT JOBSITE.RECEIVE, PROTECT, STORE, ASSEMBLE, INSTALL AND CONNECT. PROVIDE MINIMUM 5XSTRUCTURAL BACKING. (EXAMPLES: CHANDELIERS, PROJECTORS, ETC.).PROVIDE: FURNISH, INSTALL, ACTIVATE, AND COMMISSION.1.6. CODES: ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONALELECTRICAL CODE (NEC), THE 2018 EDITION OF THE INTERNATIONAL ENERGY CONSERVATIONCODE (IECC), AND ALL OTHER ADOPTED APPLICABLE FEDERAL, STATE, AND LOCALREGULATIONS.1.7. PERMITS: PAY ALL FEES AND OBTAIN ALL PERMITS AND INSPECTIONS REQUIRED FOR THEWORK.1.8. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND SCHEMATIC IN NATURE, AND INDICATE THETYPE, SIZE, ARRANGEMENT AND LOCATIONS OF MATERIALS AND EQUIPMENT. WORKINCLUDES CERTAIN COMPONENTS, APPURTENANCES, AND RELATED SPECIALTIES THAT MAYNOT BE SHOWN. PROVIDE ALL NECESSARY ITEMS TO COMPLETE THE WORK ACCORDING TOINDUSTRY STANDARDS. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TOREQUIRE FINISHED WORK, TESTED AND READY FOR OPERATION. DO NOT SCALE DRAWINGS.ARRANGEMENT OF EQUIPMENT AND ROUTING OF FEEDERS AND BRANCH CIRCUITING SHALLBE PLUMB AND AT RIGHT ANGLES TO BUILDING CONSTRUCTION, AND MAY REQUIREMODIFICATION DUE TO UNFORESEEN CONDITIONS REQUIRING ONSITE REVISIONS DURINGCONSTRUCTION. (SEE ALSO "BIDDING").1.9. COORDINATION: THIS PROJECT REQUIRES A HIGH LEVEL OF COORDINATION ANDCOOPERATION WITH OWNER, ARCHITECT, OTHER TRADES, VENDORS, AND SPECIALTYCONTRACTORS. CAREFULLY EXAMINE ALL CONTRACT DOCUMENTS INCLUDING, BUT NOTLIMITED TO, SHOP DRAWINGS, ETC. FOR ALL GENERAL CONSTRUCTION, STRUCTURAL,MECHANICAL, PLUMBING, ELECTRICAL, AND SPECIALTY CONTRACTOR WORK. PRIOR TOROUGH-IN, COORDINATE THE WORK WITH ALL OTHER TRADES, TAKING RESPONSIBILITY FORTHE PROPER FITTING OF MATERIAL INTO THE BUILDING AS PLANNED WITHOUT INTERFERENCEWITH OTHER WORK. ESTABLISH AND VERIFY LOCATIONS, HEIGHTS, CONNECTION METHODS,ETC. WITH EQUIPMENT INSTALLER (AND OWNER, ARCHITECT, AND/OR INTERIOR DESIGNERFOR FF&E ITEMS), AND MAKE REASONABLE MODIFICATIONS IN THE LAYOUTS NEEDED TOPREVENT CONFLICTS WITH OTHER TRADES IN ORDER TO PROVIDE ACCESS FOR THE PROPEREXECUTION OF THE WORK.1.10. IDENTICAL: ALL WORK REQUIRED FOR IDENTICAL ITEMS AND ASSEMBLIES OF THE PROJECTSHALL BE PROVIDED, ALTHOUGH EACH SPECIFIC IDENTICAL ITEM MAY NOT BE SHOWN INDETAIL.1.11. VERIFICATION: CHECK AND VERIFY ALL SIZES, DIMENSIONS, AND CONDITIONS BEFORESTARTING ANY WORK. ANY DEVIATION(S) OR PROBLEM(S) SHALL BE TRANSMITTED TO THEENGINEER FOR REVIEW.1.12. CONNECTIONS: CONNECT ALL EQUIPMENT, SYSTEMS, AND ASSEMBLIES PROVIDED BYOTHERS INCLUDING CONTROLS, SAFETY DEVICES AND INTERCONNECTIONS. EXCEPTION: DONOT INTERCONNECT THE CONTROL SYSTEMS OF THOSE MECHANICAL AND PLUMBINGSYSTEMS WHICH ARE SPECIFICALLY NOTED TO BE THE RESPONSIBILITY OF THOSE TRADES.PROVIDE FUSIBLE DISCONNECT SWITCHES AND MOTOR STARTERS FOR ALL EQUIPMENTEXCEPT THOSE ITEMS WHICH ARE SPECIFICALLY LISTED WITH INTEGRALSTARTERS/DISCONNECT SWITCHES. WHERE STARTERS AND/OR DISCONNECT SWITCHES AREFURNISHED TOGETHER WITH EQUIPMENT, RECEIVE, INSTALL, AND CONNECT THOSE ITEMS.1.13. SUBMITTAL: SUBMIT TO THE ENGINEER COMPLETE ELECTRONIC SETS OF SHOP DRAWINGSAND TECHNICAL DATA SHEETS FOR ALL EQUIPMENT AND MATERIALS SPECIFIED HEREIN. THEENGINEER SHALL REVIEW SHOP DRAWINGS AND TECHNICAL DATA SHEETS FORCONFORMANCE WITH THE CONTRACT DOCUMENTS AND ISSUE A WRITTEN ASSESSMENT TOTHE OWNER PRIOR TO COMMENCEMENT OF WORK. THE ENGINEER'S FAILURE TO CORRECTERRORS IN THE SUBMITTAL SHALL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATION TOPERFORM THE WORK AS SHOWN AND/OR SPECIFIED. THE CONTRACTOR SHALL BERESPONSIBLE FOR ALL ENGINEERING FEES NECESSARY TO CHANGE PROJECT DOCUMENTSBASED ON ALTERNATE SUBMITTAL PACKAGES/EQUIPMENT SUBSTITUTIONS.1.14. OR-EQUAL SUBSTITUTIONS: ALL PROPOSED "OR EQUAL" SUBSTITUTIONS SHALL BESUBMITTED TO THE ENGINEER FOR CONSIDERATION PRIOR TO BIDDING AND AFTER ALLREQUIREMENTS ASSOCIATED WITH SUBSTITUTED EQUIPMENT AND/OR MATERIALS HAVE BEENCOORDINATED WITH OTHER BUILDING TRADES, INCLUDING ALL MECHANICAL, STRUCTURAL,AND/OR ARCHITECTURAL ELEMENTS. THE OWNER'S REPRESENTATIVE SHALL PRE-APPROVEANY PROPOSED SUBSTITUTION IN WRITING. IDENTIFY AND ANNOTATE ALL REVISEDREQUIREMENTS PER BUILDING TRADE ON THE SHOP DRAWINGS. ALSO IDENTIFY ALL COSTDEBITS OR CREDITS IN WRITING FOR THE PROPOSED CHANGES PER BUILDING TRADE ANDSUMMARIZE THESE AS A TOTAL NET-TO-OWNER CHARGE OR CREDIT FOR CONSIDERATION.1.15. AS-BUILT: UPON COMPLETION OF CONSTRUCTION, SUPPLY THE ENGINEER WITH AS-BUILTDOCUMENTS ACCURATELY SHOWING THE MATERIALS AND EQUIPMENT AS INSTALLED.PROVIDE OPERATION AND MAINTENANCE MANUAL(S) CONTAINING APPROVED SHOPDRAWINGS, OPERATING AND MAINTENANCE INSTRUCTION FOR SWITCHGEAR, LIGHTINGFIXTURES, CONTROLS, AND SPECIALTY EQUIPMENT.1.16. GUARANTEE: ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A MINIMUM OFONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER (LONGER IF REQUIRED BY GENERALAND/OR SPECIAL CONDITIONS). IN ADDITION, THE INSTALLATION SHALL BE GUARANTEED TOPERFORM AS SPECIFIED AND FULFILL EACH AND EVERY REQUIREMENT OF THE DRAWINGSAND SPECIFICATIONS WHEN OPERATED IN ACCORDANCE WITH THE CONTRACTOR'SINSTRUCTIONS. SHOULD THE INSTALLATION IN ANY WAY FAIL TO DO SO, THE CONTRACTORWILL, WITHOUT DELAY AND WITHOUT COST TO THE OWNER, PROVIDE WHATEVER ADDITIONALEQUIPMENT, MATERIAL, AND LABOR REQUIRED TO CORRECT THE DEFICIENCY AND COMPLYWITH THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. WHERE SPECIFIEDEQUIPMENT HAS A LONGER GUARANTEE PERIOD, THE TERMS OF THAT GUARANTEE SHALLGOVERN (EXAMPLE: LED SYSTEM WITH 5 YEAR GUARANTEE). INCANDESCENT LAMPS AREEXEMPT BUT SHALL BE NEW AND UNUSED AT THE TIME OF FINAL ACCEPTANCE.1.18. IECC COMPLIANCE: COMPLY WITH ALL REQUIREMENTS SET FORTH IN THE IECC COMPLIANCECERTIFICATE INCLUDED IN THESE DOCUMENTS. HIRE A COMMISSIONING AGENT TO COMPLYWITH AND PERFORM ALL ASPECTS OF SECTION C408 OF THE 2018 IECC.BIDDING1.19. SITE VISIT: CONTRACT DOCUMENTS INDICATE NEW WORK TO BE PERFORMED AND DO NOTPURPORT TO SHOW ALL EXISTING CONDITIONS. VISIT THE SITE PRIOR TO SUBMITTING A BIDTO BECOME FAMILIAR WITH EXISTING CONDITIONS. COMPARE THE WORK SPECIFIED IN THECONTRACT DOCUMENTS AGAINST EXISTING CONDITIONS, AND IDENTIFY AND ANNOTATE ALLWORK OR CONDITIONS THAT ARE DIFFERENT FROM THE CONTRACT DOCUMENTS OR THEIRINTENT. UPON DISCOVERY, IMMEDIATELY NOTIFY AND REPORT IN WRITING ANYDISCREPANCIES TO THE ENGINEER. NO EXTRAS OR CHANGE ORDERS WILL BE ALLOWED FORFAILURE TO PERFORM THE PRE-BID SITE VISIT.ELECTRICAL SPECIFICATIONS1.20.1.21.1.22.1.23.BASIS OF PROPOSAL: PROPOSAL SHALL BE BASED ON MANUFACTURERS AND MODELS ASLISTED UNLESS "OR EQUAL" IS INDICATED. PROVIDE SUBSTITUTION REQUESTS A MINIMUM OFFIVE (5) BUSINESS DAYS PRIOR TO BID DATE CLOSING TO ALLOW TIME FOR DUECONSIDERATION OF PROPOSED ALTERNATE AND SUBSEQUENT NOTIFICATION TO ALL OTHERBIDDERS IN THE EVENT SUBSTITUTION IS DEEMED ACCEPTABLE. DETERMINATION OFSUBSTITUTION EQUALITY RESTS SOLELY WITH THE ENGINEER.VALUE ENGINEERING (V.E.) INITIATIVES: IN ADDITION TO THE "AS SPECIFIED/OR EQUAL" BASEBID, A COST REDUCTION INITIATIVE(S) MAY BE PROPOSED BASED ON SUBSTITUTIONS OFEQUIPMENT, MATERIALS, AND/OR METHODS. EACH SUCH PROPOSAL SHALL INCLUDE A DATASHEET(S) ON THE SPECIFIED ITEM(S), THE PROPOSED SUBSTITUTE(S), AND THE NET CREDITTO THE OWNER, INCLUDING ALL CREDITS AND CHARGES FROM ALL MEMBERS OF THECONSTRUCTION TEAM. THE ENGINEER WILL REVIEW AND RENDER AN OPINION TO THEOWNER. IF THE V.E. INITIATIVE IS DECLINED, PROVIDE THE SPECIFIEDEQUIPMENT/MATERIAL/METHOD. IF THE V.E. INITIATIVE IS ACCEPTED, AND IF SUCHACCEPTANCE RESULTS IN A REQUIREMENT TO REVISE ANY DESIGN DOCUMENTS, THECHARGES FOR THESE REVISIONS SHALL BE BILLED TO THE CONTRACTOR AND THE INVOICINGSHALL BE SETTLED BEFORE THE PROJECT IS SIGNED OFF FOR FINAL ACCEPTANCE.BIDDING: THE CIVIL, ARCHITECTURAL, MECHANICAL, KITCHEN, AND/OR INTERIOR DRAWINGSCONTAIN DETAILED DESCRIPTIONS, CIRCUITING, AND CONNECTION REQUIREMENTS WHICHARE PART OF THIS CONTRACTOR'S RESPONSIBILITIES. DO NOT SUBMIT BIDS ON THISPROJECT PRIOR TO REVIEWING ALL PROJECT DRAWINGS, SPECIFICATIONS, AND ADDENDA.SPECIFICATIONS BOOK: THE SPECIFICATIONS CONTAIN SIGNIFICANT INFORMATION,CONDITIONS, AND PROCEDURES WHICH MAY HAVE A SUBSTANTIAL IMPACT ON THISCONTRACTOR'S COSTS. DO NOT SUBMIT A BID ON THIS PROJECT UNLESS THESPECIFICATIONS HAVE BEEN THOROUGHLY REVIEWED. THE GENERAL NOTES CONTAINEDHEREIN ARE COMPLIMENTARY TO THE SPECIFICATIONS BOOK, AND IN COMPARISON THE MORESTRINGENT REQUIREMENT(S) SHALL GOVERN.PART TWO - PRODUCTS2.1. EQUIPMENT STANDARDS: ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND OF THEHIGHEST QUALITY AVAILABLE ("SPECIFICATION GRADE"). EQUIPMENT SHALL BECONSTRUCTED TO NEMA STANDARDS AND SHALL BE LABELED FOR THEIR INTENDED PURPOSEBY A RECOGNIZED TESTING AGENCY ACCEPTABLE TO THE AHJ (U.L., CSA, ETL, ETC.).2.2. ACCEPTABLE MANUFACTURERS AND SUPPLIERS : WHERE EQUIPMENT AND MATERIALS ARENOT SPECIFIED BY NAME THEY ARE DEEMED TO GENERIC, SUBJECT TO THEREQUIREMENTS LISTED HEREIN. THESE MANUFACTURERS ARE CONSIDERED CAPABLE OFOFFERING EQUIVALENT PRODUCTS. MINIMUM STANDARD IN ALL INSTANCES IS COMMERCIALGRADE:SWITCHGEAR: EATON, GENERAL ELECTRIC, SIEMENS, SQUARE DLIGHT FIXTURES: ACUITY, COOPER, HUBBELL, THOMASWIRING DEVICES: HUBBELL, LEVITON, LEGRAND, WIREMOLD2.3. CIRCUITING: ALL WIRING SHALL BE IN CONDUIT, CONCEALED WHERE POSSIBLE EXCEPT FORBRANCH CIRCUITS WITHIN EACH RESIDENTIAL UNIT. EMT WITH STEEL INSULATED THROAT SETSCREW FITTINGS MAY BE USED IN DRY, PROTECTED INTERIOR LOCATIONS. PVC SCHEDULE 40SHALL BE USED BELOW GRADE AT MINIMUM -24". WRAPPED RIGID ELBOWS AND RISERSSHALL BE USED FOR ALL THROUGH-GRADE TRANSITIONS AND STUB-UPS. RGS OR IMCCONDUIT WITH THREADED FITTINGS SHALL BE USED IN ALL LOCATIONS WHERE EXPOSED TOTHE ELEMENTS OR SUBJECT TO PHYSICAL DAMAGE. IMC OR RIGID CONDUIT BELOW GRADESHALL BE HALF-LAP WRAPPED WITH 20 MIL PVC TAPE. TYPE ENT RACEWAY IS NOT ALLOWED.CONNECT RECESSED AND SUSPENDED LIGHTING FIXTURES, MOTORIZED AND/OR VIBRATINGEQUIPMENT WITH STEEL FLEX OR SEALTITE CONDUIT. ALL CONDUIT SHALL HAVE PULL CORD IFOTHERWISE EMPTY.2.4. MC CABLE: MC CABLE MAY BE USED ONLY WITH SPECIFIC PERMISSION FROM THE ENGINEER.MC CABLE USE SHALL BE LIMITED TO CIRCUITING SOLUTIONS IN TIGHT CONDITIONS WHERECONDUIT AND WIRE CIRCUITING CANNOT FIT. HOMERUNS AND FEEDERS SHALL BE CONDUITAND WIRE.2.5. WIRING: ALL WIRE SHALL BE COPPER UNLESS OTHERWISE NOTED. ALL WIRE SHALL BESTRANDED IN SIZES #8 AWG AND LARGER. SINGLE PHASE BRANCH CIRCUITS SHALL INCLUDEA SEPARATE NEUTRAL WIRE WITH EACH PHASE WIRE. NEUTRAL SHALL BE WHITE WITH COLORSTRIPE MATCHING COLOR OF PHASE WIRE. HOMERUNS TO PANELBOARDS SHALL BE MINIMUM#12 AWG CU IN 3/4" CONDUIT UNLESS OTHERWISE NOTED.2.6. FUSES AND CIRCUIT BREAKERS: FUSES AND CIRCUIT BREAKERS SHALL BE SIZED PER ACTUALRESPECTIVE APPLICATION (i.e., MOTOR CIRCUIT PROTECTOR, GROUND FAULT CIRCUITINTERRUPTER, ARC FAULT CIRCUIT INTERRUPTER, ETC.). FUSES SHALL BE DUAL ELEMENT,CURRENT-LIMITING, AND SHALL BE INTERCHANGEABLE BETWEEN FRAME SIZES WITHSTANDARD FACTORY FUSE REDUCERS. PROVIDE LOCKABLE SPARE FUSE CABINET WITH (3)SPARE FUSES OF EACH SIZE USED.2.7. DISTRIBUTION SWITCHGEAR: SWITCHGEAR SHALL HAVE COPPER BUS AND HEAVY GAUGEHOUSINGS. SWITCHGEAR IN LOCATIONS OTHER THAN LOCKED ELECTRIC ROOMS SHALL HAVELOCKABLE COVERS. SWITCHGEAR SHALL HAVE NO LESS THAN 20% SPARE BUSSED ANDUSABLE SPACE, MEASURED AS A PERCENTAGE OF THE SPACE OCCUPIED BY SPECIFIEDCIRCUIT BREAKERS, SWITCHES, ETC.2.8. SERVICE SWITCHGEAR: IN ADDITION TO THE ABOVE, SERVICE SWITCHGEAR SHALL MEET THEREQUIREMENTS OF THE SERVING UTILITY.2.9. PANELBOARDS: PANELS SHALL HAVE COPPER BUS AND HARDWARE, BOLT-ON CIRCUITBREAKERS, FLUSH MONO-FLAT TRIM, PIANO HINGED DOORS AND COVER (DOOR-IN-DOOR)WITH LOCKABLE MASTER-KEYED FLUSH LATCHES. FLUSH-MOUNTED PANELS SHALL HAVEEMPTY CONDUITS STUBBED TO ACCESSIBLE ATTIC SPACE: (1) 3/4" CONDUIT FOR EACH THREE(3) SPARE/SPACE CIRCUITS.2.10. SAFETY SWITCHES: SWITCHES SHALL BE GENERAL DUTY UP TO 250 VOLTS, HEAVY DUTYABOVE 250 VOLTS. FUSIBLE SWITCHES SHALL BE FUSED PER THE NAMEPLATEREQUIREMENTS OF THE EQUIPMENT BEING CONNECTED.2.11. MOTOR STARTERS: STARTERS SHALL BE MINIMUM NEMA SIZE 1 WITH INTEGRAL CONTROLTRANSFORMER, RED NEON "RUN" PILOT LIGHT AND "ON-OFF-AUTO" SELECTOR SWITCH ONCOVER. OVERLOAD DEVICES SHALL BE SIZED PER THE NAMEPLATE AMPERAGE OF THEEQUIPMENT BEING CONTROLLED.2.12. CONTACTORS: CONTACTORS SHALL BE ELECTRICALLY HELD WITH "ON-OFF-AUTO" SELECTORSWITCH ON COVER.2.13. RATINGS: ALL ELECTRICAL EQUIPMENT SHALL BE FULLY RATED FOR BRACING IN EXCESS OFTHE MAXIMUM AVAILABLE FAULT CURRENT CALCULATED AND SHOWN AT THE EQUIPMENTCONNECTION POINT WITHIN THE DISTRIBUTION SYSTEM. MINIMUM RATING SHALL BE 10K AIC.2.14. WIRING DEVICES: WIRING DEVICES (SWITCHES, RECEPTACLES, ETC.) SHALL BESPECIFICATION GRADE "DECORA" STYLE, MINIMUM 20-AMP RATED. COVER PLATES SHALL BENYLON. DEVICE AND PLATE COLOR(S) SHALL BE AS SPECIFIED BY ARCHITECT OR INTERIORDESIGNER - VERIFY PRIOR TO COMMENCEMENT OF WORK. WIRING DEVICES EXPOSED TO THEELEMENTS SHALL HAVE WEATHERPROOF-IN-USE LOCKABLE COVERS. RAISED STEEL BOXCOVERS MAY BE USED IN UTILITY AREAS. REFER TO FOOD SERVICE NOTES (IF APPLICABLE TOTHIS PROJECT) FOR ADDITIONAL REQUIREMENTS.2.15. TRANSFORMERS: TRANSFORMERS SHALL BE TYPE TP-1 MINIMUM, WITH ALUMINUM WINDINGS,RATED FOR 150°C RISE (UNLESS OTHERWISE NOTED), MOUNTED ON RUBBER-IN-SHEARVIBRATION ISOLATORS, CONNECTED WITH FLEXIBLE CONDUIT. PUBLISHED AND MEASUREDNOISE RATING SHALL NOT EXCEED NEMA TP-20 MAXIMUM.2.16. LIGHTING FIXTURES: LIGHT FIXTURES SHALL BE PROVIDED WITH ALL ASSOCIATED HARDWARE(HANGER BARS, PENDANTS, STEMS, RESTRAINTS, CHAINS, CORDS, LAMPS, ETC.). LENSESSHALL BE ACRYLIC, REFLECTORS SHALL BE ANODIZED. FLUORESCENT BALLASTS SHALL BEELECTRONIC, PROGRAM RAPID START, THD LESS THAN 10%. FLUORESCENT LAMPS SHALLHAVE MINIMUM CRI OF 80%. INCANDESCENT LAMPS SHALL BE 120 VOLT, INSIDE FROST,MINIMUM 2000 HOUR LIFE. LOW VOLTAGE INCANDESCENT LAMPS SHALL BE HIR HALOGEN,MINIMUM 3000 HOUR LIFE. EXTERIOR LIGHTING FIXTURES SHALL BE INSTALLED TO PREVENTWATER, DUST AND INSECT INTRUSION, WITH GASKETING FOR DOOR/BACKPLATE AND SEALANTAT THE WIRING ENTRY POINT. REFER TO LIGHTING FIXTURE SCHEDULE WITHIN PLAN SET FORADDITIONAL REQUIREMENTS (LED CRITERIA, ETC.).2.17. TAMPERPROOF: ALL EQUIPMENT AND CIRCUITING ACCESSIBLE BY THE PUBLIC SHALL BEDEMONSTRATED TO BE TAMPERPROOF AND VANDAL RESISTANT. OPENABLE DEVICES ANDEQUIPMENT SHALL BE PAD LOCKABLE.PART THREE - EXECUTION3.1. GROUNDING: GROUND ALL EQUIPMENT AND SYSTEM NEUTRAL IN ACCORDANCE WITH THEREQUIREMENTS OF NEC ARTICLE 250. PROVIDE CODE-SIZED EQUIPMENT GROUNDINGCONDUCTOR IN ALL FEEDERS AND BRANCH CIRCUIT RACEWAYS. WHERE ISOLATED GROUNDSARE INDICATED, PROVIDE INSULATED CONDUCTOR (GREEN WITH YELLOW STRIPE).3.2. UTILITY SERVICES: PROVIDE POWER AND COMMUNICATIONS SYSTEM SERVICES INACCORDANCE WITH THE REQUIREMENTS OF THE SERVING UTILITIES. CONTRACTOR TOPROVIDE ARC FLASH STUDY AND LABELLING ON ALL NEW EQUIPMENT IN ACCORDANCE WITHNEC. PROVIDE EXCAVATION, RACEWAY, STRUCTURES, GROUNDING, ETC. AS DIRECTED.POWER SERVICES AND DISTRIBUTION SYSTEM AIC RATING SHALL EXCEED MAXIMUMAVAILABLE FAULT CURRENT THROUGH UTILITY SERVICE TRANSFORMER. CONTACT SERVINGUTILITIES AND OBTAIN THEIR REQUIREMENTS PRIOR TO BID. (UTILITY SERVICE AND LINEEXTENSION CHARGES PAID BY OTHERS).3.3. TEMPORARY CONSTRUCTION POWER : PROVIDE TEMPORARY ELECTRICAL POWERDISTRIBUTION AND LIGHTING AS REQUIRED FOR ALL TRADES THAT REQUIRE SERVICE DURINGTHE COURSE OF THIS PROJECT IN COMPLIANCE WITH ALL NEC AND OSHA REQUIREMENTS.OWNER SHALL NOT BE RESPONSIBLE FOR TEMPORARY POWER CHARGES.3.4. LOCATIONS: INDICATED LOCATIONS OF ALL OUTLETS AND EQUIPMENT ARE SUBJECT TOCHANGE. SHIFT/RELOCATE/RECONFIGURE ANY OUTLET, EQUIPMENT OR CONNECTION POINTUP TO 10' AS DIRECTED BY ENGINEER AT NO ADDED COST.3.5. WORKMANSHIP: THE WORK SHALL BE INSTALLED PARALLEL AND AT RIGHT ANGLES TO THEBUILDING LINES, LEVEL AND PLUMB. THE WORK SHALL BE WELL SUPPORTED AND SOLIDLYMOUNTED. DRESS AND TIE WIRING IN PANELBOARDS AND SWITCHGEAR. THE WORK SHALL BELEFT CLEAN WITH NO DIRT, DENTS, ABRASIONS, PAINT SPLATTERS, OR OTHERIRREGULARITIES.3.6. FIRE STOPPING: ALL PENETRATED FIRE RATED SURFACES SHALL BE FIRE SEALED WITHAPPROVED U.L. LISTED SEALANTS AS LISTED WITHIN ARCHITECTURAL SPECIFICATIONS. DONOT EXCEED MAXIMUM ALLOWABLE SURFACE PENETRATIONS DEPENDENT ON RATING OFSURFACES. REFER TO ARCHITECTURAL DRAWINGS FOR DETERMINATION OF PENETRATIONLOCATIONS THROUGH FIRE RATED ASSEMBLIES.3.7. SUPPORTS AND HANGERS : PROVIDE 3" HIGH HOUSEKEEPING CONCRETE PAD BENEATHFLOOR MOUNTED EQUIPMENT, EXTENDING 3" BEYOND EQUIPMENT FOOTPRINT. SUPPORTAND ALIGN ALL RACEWAYS, CABINETS, BOXES, BACK BOXES, FIXTURES, AND EQUIPMENTFROM STRUCTURE. SECURE ALL SUPPORTING METHODS BY MEANS OF TOGGLE BOLTS INHOLLOW MASONRY, EXPANSION BOLTS IN SOLID MASONRY, CONCRETE PRESET INSERTS OREXPANSION BOLTS IN CONCRETE, MACHINE SCREWS OR BOLTS IN METAL, AND WOODSCREWS IN WOOD CONSTRUCTION. ALL SUPPORTING SYSTEMS AND COMPONENTS SHALL BERATED FOR A MINIMUM OF FIVE (5) TIMES THE ACTUAL LOAD.3.8. SLEEVES AND PENETRATIONS: PENETRATIONS OF ALL SURFACES SHALL BE PROVIDED WITHSLEEVES THAT SHALL BE SEALED WITH LIKE MATERIALS AND SHALL BE FINISHED WITHESCUTCHEON PLATES. PENETRATIONS BELOW GRADE LEVEL SHALL BE WATERTIGHT.PENETRATIONS AT EXTERIOR WALLS SHALL BE WEATHERPROOF. ROOF PENETRATIONSSHALL BE FLASHED AND COUNTER FLASHED.3.9. EXPANSION AND CONTRACTION: RACEWAYS PASSING THROUGH BUILDING EXPANSIONJOINTS, ON ROOF, AND IN AREAS OF TEMPERATURE VARIATIONS GREATER THAN 30°F SHALLBE INSTALLED WITH EXPANSION FITTINGS.3.10. IDENTIFICATION: IDENTIFY ALL EQUIPMENT, SWITCHBOARD CIRCUITS AND ELECTRICALLY-CONNECTED EQUIPMENT WITH ENGRAVED NAMEPLATES. BOXES SHALL BE MARKED WITHPANEL AND CIRCUIT NUMBERS (PERMANENT PEN ACCEPTABLE ABOVE CEILING).NAMEPLATES SHALL BE FASTENED WITH A MINIMUM OF TWO (2) SCREWS. PANELDIRECTORIES SHALL BE TYPED. CONDUCTORS SHALL BE TAGGED WITH CIRCUIT NUMBERS ATSOURCE, JUNCTION BOXES, AND ALL OUTLET BOXES WITH PERMANENT ADHESIVE MARKERSTRIP. PANEL DIRECTORIES SHALL BE TYPED. IDENTIFY WIRING DEVICES WITH SELFADHESIVE CLEAR SATIN FINISH LABELS WITH SOURCE AND CIRCUIT NUMBER.3.11. ELECTRIC ROOM CODE COMPLIANCE : DUE TO THE DIAGRAMMATIC NATURE OF THE DESIGNDOCUMENTS (ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, ETC.), COORDINATEWITH ALL OTHER SUBCONTRACTORS AT THE START OF THIS PROJECT TO INFORM AND VERIFYTHAT NO FOREIGN SYSTEMS OR EQUIPMENT ARE MOUNTED ABOVE ELECTRICAL EQUIPMENTOR PASS THROUGH THE DESIGNATED ELECTRIC ROOMS, AND THAT A MINIMUM OF 7'-0" ISPROVIDED AS CLEAR HEADROOM ALONG ACCESS PATHS TO ELECTRIC ROOMS. ANYREROUTING OR RELOCATION OF SYSTEMS THAT A SUBCONTRACTOR FEELS WILLCOMPROMISE THE DESIGN INTENT SHALL BE DESCRIBED IN WRITING AND FORWARDED TOTHE DESIGN ENGINEER FOR FURTHER REVIEW. ALL PIPING TO HVAC UNITS THAT COOLELECTRIC ROOMS SHALL BE LOCATED ABOVE ENTRY DOOR. THE SPRINKLER PIPING TOPROVIDE PROTECTION FOR THE ELECTRIC ROOM IS PREFERRED TO ENTER THE ROOM ABOVETHE ENTRY DOOR AND RUN DOWN THE AISLE SPACES OF THE ROOM. ALL INSTALLATIONSSHALL BE FULLY COORDINATED AMONGST ALL TRADES.3.12. ELECTRICALLY-OPERATED EQUIPMENT: VERIFICATION AND SUBSTITUTION: FEEDERS ANDOVER-CURRENT DEVICES (INCLUDING STARTERS, DISCONNECTS, ETC.) HAVE BEEN DESIGNEDBASED ON INFORMATION PROVIDED BY THE RESPONSIBLE CONSULTANT AND/OR DESIGNATEDSUPPLIER. PRIOR TO ROUGH-IN, COORDINATE WITH THE APPROPRIATE TRADE AND/ORINSTALLER TO DETERMINE THAT THE ACTUAL NAMEPLATE ELECTRICAL REQUIREMENTSMATCH THIS DESIGN. ALL ADDITIONAL ELECTRICAL COSTS RELATED TO THE CONNECTION OFEQUIPMENT WHICH VARIES FROM THE ORIGINAL SPECIFICATIONS SHALL BE RESOLVED WITHINTHE CONSTRUCTION TEAM AT NO ADDITIONAL COST TO THE OWNER.3.13. ADDITIONAL SYSTEMS AND EQUIPMENT CONNECTIONS : IN ADDITION TO EQUIPMENT POWERFEEDERS AND CONNECTIONS INDICATED ON THE ELECTRICAL DRAWINGS, PROVIDE 120VCONTROL POWER CONNECTIONS TO SMOKE/FIRE DAMPERS, VAV BOXES, TEMPERATURECONTROL, FIRE ALARM PANELS, DOOR HOLDING/LATCHING DEVICES, ETC. AS INDICATED INTHE PROJECT DRAWINGS AND SPECIFICATIONS AS WELL AS ALL DESIGN-BUILD SYSTEMDRAWING.MAX NO. PER PROVIDE SMOKEITEMPOWER SOURCE20A CIRCUIT DETECTORSFIRE/SMOKE DAMPEREMERGENCY10YESVAV TERMINAL (NO FAN)NORMAL (VERIFY)10NOTEMPERATURE CONTROL PANELEMERGENCY (VERIFY) 1NOFIRE ALARM PANELEMERGENCY1NODOOR HOLDING/LATCHING DEVICES EMERGENCY10NO3.14. HOURS OF OPERATION: CONDUCT WORK TO MINIMIZE DISRUPTION OF OWNER'S ONGOINGBUSINESS OPERATIONS. PROVIDE BARRICADES, NOISE ABATEMENT, AND DUST CONTAINMENTMEASURES TO ENSURE THE SAFETY AND COMFORT OF PATRONS, STAFF, AND WORKERS.INTERRUPTIONS OF EXISTING POWER, COMMUNICATIONS, AND/OR FIRE ALARM SYSTEMSSHALL BE PERFORMED ONLY AT SUCH TIMES AS DIRECTED BY OWNER OR RESIDENTENGINEER. OUTAGES SHALL BE MOMENTARY IN NATURE, EACH SUCH OUTAGE (OROPERATION WHICH MAY POSE RISK OF AN ACCIDENTAL OUTAGE) SHALL BE SCHEDULED AMINIMUM OF FORTY-EIGHT (48) HOURS IN ADVANCE.3.15. COMMUNICATIONS SYSTEMS: THE ELECTRICAL CONTRACTOR SHALL PROVIDE OUTLETS ANDRACEWAYS FOR COMMUNICATION SYSTEMS AS INDICATED HEREIN, INCLUDING TELEPHONE,DATA, POINT-OF-SALE, SOUND, SECURITY, AUDIO/VISUAL, CCTV, MATV, ETC. CABLING ANDDEVICES SHALL BE INSTALLED AND TERMINATED BY OTHERS.PART FOUR - SPECIAL SYSTEMS4.1. THIRD PARTY TESTING: PROVIDE ALL ASSOCIATED COSTS FOR THIRD PARTY TESTING OF ALLEQUIPMENT, CONDUCTORS, GROUND FAULT, GROUND FAULT COORDINATION STUDY WITHREPORT PREPARATION, ETC. AS REQUIRED BY THE NEC, AHJ, AND ALL OTHER GOVERNINGAUTHORITIES.200 S. ORANGE AVENUESUITE 600ORLANDO, FL 32801PHONE: 407.898.1511REGISTRY NO. 351062025 ©This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.JIMMY NGUYENPE 91973ARCH/ENGR OF RECORDDESIGNED BYJNDRAWN BYSRMISSUE DATE11/18/2025AE PROJECT NUMBER145642001SHEET TITLEELECTRICAL SPECIFICATIONSDRAWING NO.E001GIRLS BOYS13-005A13-004APRIMARY/INTERMCLASSROOM13-005PRIMARY/INTERMCLASSROOM13-004HVAC EQUIPCOUURT13-001812E101 E101BOYS/GIRLS13-003APRIMARY/INTERMCLASSROOM13-003MECHANICAL13-0013CUSTODIAL13-0015CORRIDOR13-0017ELECT.13-0012GIRLS BOYS13-002A13-001APRIMARY/INTERMCLASSROOM13-002SYSTEMS13-0014PRIMARY/INTERMCLASSROOM13-001GIRLS13-019BOYS13-020PRIMARY/INTERMCLASSROOM13-006PRIMARY/INTERMCLASSROOM13-007TEACHERPLANNING13-008TEACHERPLANNING13-009PRIMARY/INTERMCLASSROOM13-0010PRIMARY/INTERMCLASSROOM13-0011GIRLS BOYS13-006A13-007AGIRLS BOYS13-0010A13-0011A1ELECTRICAL NEW PLAN3/32" = 1'-0"GENERAL DEMO NOTES:A.MAKE ALL NECESSARY ALTERNATION TO COORDINATE AND CONNECT THE EXISTING WITH THE NEWELECTRICAL WORK TO THE END THAT WHEN THE WORK IS COMPLETE. THE ENTIRE ELECTRICALINSTALLATION, EXISTING AND NEW, SHALL BE IN COMPLETE OPERATION CONDITION. THE DRAWINGSINDICATE THE WORK WHICH IS TO BE IN PLACE AT THE COMPLETION OF THE INSTALLATION.B.EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY, ALL EXISTING FIXTURES, SWITCHES AND OTHERMATERIALS OR EQUIPMENT THAT IS REPLACED WITH NEW AND IS NOT INDICATED TO BE REUSED SHALL BETURNED OVER TO THE OWNER OR BE DISPOSED OF AS DIRECTED BY THE OWNER.C.EXISTING MATERIAL TO REMAIN UPON COMPLETION IS INDICATED ON DRAWINGS AS EXISTING. CONDUIT ANDWIRING IS EXISTING TO THEIR RESPECTIVE SOURCE. ALTHOUGH NOT INDICATED ON THE DRAWINGS, THISMAY REQUIRE TEMPORARY REMOVAL OR RE-ROUTING OF CONDUITS AND REPLACING EXISTING WIRINGWITH NEW DURING THE COURSE OF CONSTRUCTION WORK.D.FURNISH AND INSTALL NEW BLANK PLATES FOR ALL REMOVED OUTLETS,6S.86WSIFT2C2H.7ESFS, LIGHT FIXTURES, ETC.,WHEN THE OUTLET BOX IS TO REMAIN.CASEMENTE.REMOVE ALL EXISTING CONDUCTORS AND EXPOSED CONDUITS ABANDONED BACK TO PANEL BOARD. LABELNEW PANEL DIRECTORY AS "SPARE"EFCO SERIES 660 SH (3)6.86 SF = 20.58 SF SH +22.7 SF CASEMENT = 43.28 SF TOTALF.MAINTAIN CONTINUITY OF ALL ELECTRICAL SYSTEMS, EQUIPMENT, ETC., REMAINING IN OPERATION WHICH ISBEING FED BYCONDUIT ANDWANIRAINBGA,NADSORNEEQDUOIRUETDLETTO. MSAUIINTTTAHINEINEXGISCTO5SI%NFN(NGT8A9I7NTCUGUORSIANFTL)DYCVILESTANIHSTOSIALRNALOTSLOIO.MCNO= 4N4.S85ISTOFRE-ROUTINGOFREQUIREDGENERAL NEW NOTES:A.FURNISH ALL LABOR, MATERIALS, TOOLS, ACCESSORIES, ETC. REQUIRED FOR A COMPLETE WORKINGELECTRICAL SYSTEM.B.ALL ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL CODES ANDORDINANCES, AS WELL AS ALL CURRENT STANDARDS, CODES AND PRACTICES AS REQUIRED BY NEC2017, NEMA, ANSI, NFPA, UBC, UL, IEEE, AND UTILITY COMPANY STANDARDS.C.ALL EQUIPMENT, MATERIALS, AND WORK SHOWN ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTINGOR NOTED OTHERWISE ON OTHER SHEETS.D.ANY POWER OUTAGE OF ANY CIRCUIT SHALL BE APPROVED BY THE OWNER IN WRITING A MINIMUM OFTWO WEEKS PRIOR TO OUTAGE. ALL OUTAGES SHALL BE DONE EXACTLY WHEN DETERMINED BY THEOWNER AND DONE BEFORE OR AFTER WORKING HOURS AND ON WEEKENDS. NO SINGLE OUTAGE SHALLREQUIRE MORE THAN 4 HOURS. PROVIDE TEMPORARY POWER, HEAT AND COOLING AS REQUIREDDURING OUTAGE.E.DUE TO THE REQUIREMENTS TO INTERFACE WITH EXISTING FACILITIES AND UTILITIES, IT IS REQUIREDTHAT THE CONTRACTOR VISIT THE SITE TO DETERMINE EXISTING CONDITIONS PRIOR TO BID.F.PRIOR TO PURCHASE OF ANY PANEL, PROTECTIVE DEVICES, SWITCH, STARTER, CONDUIT, WIRE, ETC., TOFEED ANY PIECE OF MECHANICAL EQUIPMENT, VERIFY THE VOLTAGE, PHASE, AND LOAD OF THAT ITEM INTHE FIELD AND/OR WITH THE PARTICULAR ENTITY INVOLVED IN FURNISHING THE ITEM SUCH THAT THEPROPER SIZE & RATING OF THE MATERIALS ARE PURCHASED. NO EXTRAS WILL BE ALLOWED FORFAILURE TO COMPLY. THIS APPLIES TO ALL EQUIPMENT UNDER OTHER SECTIONS & BY THE OWNER.G.PULL ROPES: PROVIDE 300 POUND PULL WIRE OR NYLON EQUIVALENT IN ALL INTERIOR EMPTY CONDUITRUNS. PROVIDE 1/4" DIA NYLON PULL ROPE IN EACH EMPTY EXTERIOR CONDUIT OR DUCT.H.COORDINATE WITH MECHANICAL CONTRACTOR TO AVOID CONFLICTS BETWEEN DUCT WORK, SUPPLY &EXHAUST DIFFUSERS, LIGHTING, SOUND SYSTEMS, AND FIRE ALARM SYSTEM FIXTURES.I.ELECTRICAL CONTRACTOR SHALL GUARANTEE THE ELECTRICAL WORK TO BE FREE FROM DEFECTS INMATERIALS AND WORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF FINAL ACCEPTANCE.J.VERIFY THE EXACT LOCATION AND ELEVATION OF ALL ELECTRICAL EQUIPMENT PRIOR TO ROUGH-IN.FINAL CONNECTIONS OF EQUIPMENT SHALL BE PER MANUFACTURERS APPROVED WIRING DIAGRAMS,DETAILS, AND INSTRUCTIONS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE MATERIALS ANDEQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED.NOTE: COORDINATE LUMINAIRE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS.K.ORDER AND/OR RELEASE ORDERED MATERIALS PROMPTLY AFTER SUBMITTAL APPROVAL. NOSUBSTITUTIONS OR ALTERNATE METHODS OF INSTALLATION WILL BE ACCEPTED FOR FAILURE TO ORDERMATERIALS IN A TIMELY FASHION.L.OBTAIN WRITTEN APPROVAL FROM THE ENGINEER OF ALL SHOP DRAWINGS AND MANUFACTURERS DATAFOR PANEL BOARDS, TRANSFORMERS, WIRING DEVICES, ETC. BEFORE RELEASING ORDERED MATERIALS.SUBMITTAL DATA SHALL INDICATE THAT THE CONTRACTOR HAS REVIEWED THE INFORMATION THEREINAND THAT THE PROPOSED EQUIPMENT WILL MEET THE PHYSICAL CONSTRAINTS AT THE JOB SITE. ANYSUBSTITUTIONS SHALL BE OF THE EQUIVALENT OR BETTER QUALITY THAN THE SPECIFIED COMPONENTS.M.TYPE MC OR TYPE AC CABLE SHALL ONLY BE USED WITH THE SPECIFIC WRITTEN PERMISSION OF THEPROGRAM/PROJECT MANAGER. ENT TYPE CONDUIT IS NOT ALLOWED.N.CONDUIT/CONDUCTOR RUNS SHOWN ARE DIAGRAMMATICAL ONLY. THE BEST FINAL CONDUIT ROUTINGSHALL BE AS DETERMINED BY THE ELECTRICAL CONTRACTOR AT THE TIME OF CONSTRUCTION.O.ALL WIRE SHALL BE COPPER. MINIMUM SIZE FOR POWER WIRING SHALL BE #10 AWG. STRANDED UNLESSOTHERWISE NOTED. MINIMUM SIZE FOR CONTROL WIRING SHALL BE #14 AWG.P.PROVIDE ALL PANEL BOARDS WITH TYPED DIRECTORIES INSTALLED UNDER A CLEAR PLASTIC COVER.SUBMIT DIRECTORY INFORMATION TO THE OWNER FOR APPROVAL PRIOR TO FINALIZATION.Q.SERIES RATING OF UPSTREAM OR DOWNSTREAM CIRCUIT BREAKERS OR FUSES IS PROHIBITED. ONLYFULLY RATED SYSTEM COMPONENTS WILL BE ACCEPTED.R.ALL PANEL BOARDS, SWITCHES, MOTOR STARTERS, AND SWITCHBOARD CIRCUIT BREAKERS SHALL HAVEENGRAVED MICARTA NAMEPLATES.S.ALL CIRCUITS THAT SHARE A NEUTRAL SHALL BE PROVIDED WITH MULTIPOLE BREAKER.200 S. ORANGE AVENUESUITE 600ORLANDO, FL 32801PHONE: 407.898.1511REGISTRY NO. 351062025 ©This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.JIMMY NGUYENPE 91973ARCH/ENGR OF RECORDDESIGNED BYJNDRAWN BYSRMISSUE DATE11/18/2025AE PROJECT NUMBER145642001SHEET TITLEELECTRICAL SITE PLANDRAWING NO.E1001(EX)CH-14CH-1HVAC EQUIPCOUURT13-0018KEYNOTES1 ELECTRICAL CONTRACTOR SHALL DEMOLISH FUSES ANDEQUIPMENT FEEDERS FROM CH-1 TO DISC SW. ELECTRICALRACEWAYS AND DISC SW SHALL REMAIN IN PLACE AND BEPROTECTED DURING ALL PHASES OF CONSTRUCTION.2 ELECTRICAL CONTRACTOR SHALL DEMOLISH EXISTING125A, 480V/3P CKT BKR FROM PANEL EPP 3737. FEEDERSAND RACEWAY SHALL REMAIN IN PLACE AND BEPROTECTED DURING ALL PHASES OF CONSTRUCTION.MEGGER TESTING SHALL BE PERFORMED BY ANETA-CERTIFIED TECHNICIAN TO VERIFY THE EXISTINGFEEDERS ARE SUFFICIENT AND ACCEPTABLE FOR REUSE.ELECTRICAL CONTRACTOR SHALL PROVIDE FEEDERLENGTHS TO ENGINEER OF RECORD.3 ELECTRICAL CONTRACTOR SHALL PROVIDE 150A, 480V/3PCKT BKR IN PANEL EPP 3737 AND RECONNECT EXISTINGFEEDERS.4 ELECTRICAL CONTRACTOR SHALL INSTALL 150A FUSES ANDEXTEND FEEDERS FROM DISC SWITCH TO CH-1. ELECTRICALCONTRACTOR SHALL PROVIDE FEEDER LENGTHS TOENGINEER OF RECORD.200 S. ORANGE AVENUESUITE 600ORLANDO, FL 32801PHONE: 407.898.1511REGISTRY NO. 351062025 ©This document is an instrument of service preparedsolely for Kimley-Horn's client and for a particularpurpose. Any other use or reliance is without liability toKimley-Horn.ELEC ETR 0605ELEC ETR 0604 ELEC EPP 3730ELEC EPP 3734ELEC EPP 3733ELEC EPP 3731ELEC EPP 3732ELEC EPP 37352 ELEC EPP 37371ELECTRICAL DEMO ENLARGED PLAN3/8" = 1'-0"MECHANICAL13-0013CUSTODIAL13-0015ELEC ETR 0605ELEC ETR 0604 ELEC EPP 3730ELEC EPP 3731ELEC EPP 3734ELEC EPP 3733ELEC EPP 3732ELEC EPP 3735ELECT.13-00123 ELEC EPP 3737SYSTEMS13-00142ELECTRICAL NEW ENLARGED PLAN3/8" = 1'-0"JIMMY NGUYENPE 91973ARCH/ENGR OF RECORDDESIGNED BYJNDRAWN BYSRMISSUE DATE11/18/2025AE PROJECT NUMBER145642001SHEET TITLEPOWER PLANDRAWING NO.E101
- Commodity Codes
-
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Administration Center HVAC Ch...
Project ID: Y26-753 Title: Administration Center HVAC Chiller Plant Upgrades Addenda: 0 Release
Orange County
Bid Due: 7/30/2026
Main Agency Pinellas County School Board Status Active Fiscal Year 2026 Primary Contact
Pinellas County School Board
Bid Due: 7/08/2026