Bid 26121 - Edward L. Smith Library HVAC Replacement
Project Information
- Bid Title
- Bid 26121 - Edward L. Smith Library HVAC Replacement
- Issuing Agency
- Town of North Branford
- Location
- Connecticut
- Published Date
- Jan 27, 2026
- Closing Date
- Mar 4, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Bid 26121
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid Number: Bid 26121
Bid Title: Bid 26121 - Edward L. Smith Library HVAC Replacement
Category: Bids Status: Open Description: The Edward L. Smith Library HVAC Replacement project consists of removal and replacement of the building’s VRF systems with controls, perimeter electric heating systems, exhaust fans with controls and supplemental electrical, structural, cutting, patching, and painting scope of work. CHRO and Prevailing Wage Rates are required.
Publication Date/Time: 1/27/2026 4:15 PM Publication Information: ADVERTISED 01/25/2026 Closing Date/Time: 3/4/2026 11:00 AM Submittal Information: Submit PDF of bids digitally to: bids@nbct.us Hard Copy Bid Bond Bid Opening Information: Town Hall Pre-bid Meeting: Friday February 6, 2026 10AM Business Hours: M_F 8:30-4:30 Fax Number: 203-484-6025 Related Documents: - Attachment Preview
-
LOCATION PLANN NOT TO SCALETOWN OF NORTH BRANFORD3 OLD POST ROAD,NORTHFORD, CT 06472EDWARD L. SMITH LIBRARY HVAC REPLACEMENTBID DOCUMENTSJANUARY 16, 2026ENGINEER:919 Middle StreetMiddletown, CT 06467Phone: (860) 635-7740Fax: (860) 635-7312PROJECT LOCATIONINDEX OF DRAWINGSNO.TITLECOVER SHEETM001MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONSMD101 MECHANICAL LOWER LEVEL PLAN - DEMOLITION WORKMD102 MECHANICAL UPPER LEVEL PLAN - DEMOLITION WORKM101MECHANICAL LOWER LEVEL PLAN - NEW WORKM102MECHANICAL UPPER LEVEL PLAN - NEW WORKM401MECHANICAL DETAILSM402MECHANICAL DETAILSM403MECHANICAL DETAILSM404MECHANICAL DETAILSM405MECHANICAL DETAILSM406MECHANICAL DETAILSM407MECHANICAL PIPING DIAGRAMSM408MECHANICAL CONTROL DIAGRAMSM501MECHANICAL SCHEDULESE001ELECTRICAL NOTES, SYMBOLS LIST AND ABBREVIATIONSED-101 ELECTRICAL FIRST FLOOR PLAN DEMOLITIONED-102 ELECTRICAL SECOND FLOOR PLAN DEMOLITIONE-101ELECTRICAL FIRST FLOOR PLAN NEW WORKE-102ELECTRICAL SECOND FLOOR PLAN NEW WORKE-401ELECTRICAL PANEL SCHEDULESE-402ELECTRICAL SCHEDULES & ONE-LINE DIAGRAMGENERAL MECHANICAL SYMBOLSHVAC SYMBOLS----11Room5NUMBER OF DETAIL ON SHEETNUMBER OF SHEET WHERE DETAIL APPEARSDEMOLITION WORK KEYNOTENEW WORK KEYNOTECONTINUATION SYMBOLROOM NAME AND NUMBER18"x12"18"/12"18"Ø18"x18" S/ASQUARE DUCT SIZE TAG (WIDTH x HEIGHT)OVAL DUCT SIZE TAG (WIDTH / HEIGHT)ROUND DUCT SIZE TAG (DIAMETER)EXISTING DUCT (THIN, LIGHT LINES)DUCT BEING DEMOLISHEDSUPPLY AIRAREA NOT IN CONTRACT18"x18" O/AOUTSIDE AIREXISTING ITEM TO BE REMOVEDTHICK, DASHED LINES ON DEMOLITION DWGSINDICATE EXISTING ITEM TO BE REMOVED18"x18" R/A18"x18" T/A18"x18" E/ARETURN AIRTRANSFER AIRGENERAL EXHAUST AIRTHICK, DARK SOLID LINES ON NEW WORKDWGS INDICATE NEW OR RELOCATED ITEMSTHIN, LIGHT LINES ON DEMOLITION AND NEWWORK DWGS INDICATE EXISTING ITEMS TOREMAIN IN PLACE AND BE REUSEDPOINT OF DEMOLITION WORK CONNECTION TO EXISTINGCAPPROVIDE PERMANENT CAP (INSULATE CAP AS REQUIRED)POINT OF DEMOLITION WORK CONNECTION TO EXISTINGPROVIDE TEMPORARY CAP DURING CONSTRUCTIONPOINT OF NEW WORK CONNECTION TO EXISTINGETRSUB LETTERS ETR INDICATES EXISTING EQUIPMENT TO REMAIN INTACTABBREVIATIONSØABVACADADDAFFAFGAFUEALTAPARCHBFFBLWBODBOPBTUBTUHCAPCBCFMCLGCOCWDDBDHWGDIADNDWEAEATELECEQUIPEWCEWTE/AEXISTFFCOFDFDCFLFOFOVFORFOSFPMFSFTFTRGALGFGCGPMGWHBHPHTGHTRHVLSHWIDININVKHWGLBLB/HRLATLPGROUNDABOVEAIR CONDITIONINGAREA DRAINADDENDUMABOVE FINISHED FLOORABOVE FINISHED GRADEANNUAL FUEL UTILIZATION EFFICIENCYALTERNATEACCESS PANELARCHITECT/ARCHITECTURALBELOW FINISHED FLOORBELOWBOTTOM OF DUCTBOTTOM OF PIPEBRITISH THERMAL UNITSBRITISH THERMAL UNITS PER HOURCAPACITYCATCH BASINCUBIC FEET PER MINUTECEILINGCLEAN OUTCOLD WATERDEGREEDRY BULBDOMESTIC HOT WATER GENERATORDIAMETERDOWNDISTILLED WATEREACHENTERING AIR TEMPERATUREELECTRICALEQUIPMENTELECTRIC WATER COOLERENTERING WATER TEMPERATUREEXHAUST AIREXISTINGDEGREES FAHRENHEITFLOOR CLEAN OUTFLOOR DRAINFIRE DEPARTMENT CONNECTIONFLOORFUEL OILFUEL OIL VENTFUEL OIL RETURNFUEL OIL SUPPLYFEET PER MINUTEFLOOR SINKFOOT/FEETFIN TUBE RADIATIONGALLONGAS-FIREDGENERAL CONTRACTORGALLONS PER MINUTEGREASE WASTEHOSE BIBHORSE POWERHEATINGHEATERHIGH VOLUME LOW SPEEDHOT WATERINDIRECTINCHINVERTKITCHEN HOT WATER GENERATORPOUNDPOUNDS PER HOURLEAVING AIR TEMPERATURELIQUEFIED PETROLEUM GASLVRLWTM/AMAXMBHMCFMDMECHMFRMINMISCMTRMU/ANCNCNICNONONTSOO/AORDPDPIVPLBGPRESSPRVPSIPSIGPWRRR/ARCPRDRECREDRHRL/ARMRPMRWSFS/ASANSFSDSMSPSPSTMTT.O.P.TDTDRTEMPTYPUGVACVVAVVENTVTRWWBWCOWHLOUVERLEAVING WATER TEMPERATUREMIXED AIRMAXIMUMONE THOUSAND BTU PER HOURONE THOUSAND CUBIC FEETMOTORIZED DAMPERMECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMOTORMAKE-UP/AIRNOISE CRITERIANORMALLY CLOSEDNOT IN CONTRACTNUMBERNORMALLY OPENNOT TO SCALEOXYGENOUTSIDE AIROVERFLOW ROOF DRAINPRESSURE DROPPOST INDICATOR VALVEPLUMBINGPRESSUREPRESSURE REDUCING VALVEPOUNDS PER SQUARE INCHPOUNDS PER SQUARE INCH GAUGEPOWERDUCT RISERRETURN AIRRADIANT CEILING PANELROOF DRAINRECESSEDREDUCERRELATIVE HUMIDITYRELIEF AIRROOMREVOLUTIONS PER MINUTERAIN WATERSQUARE FOOTSUPPLY AIRSANITARYSQUARE FOOTSMOKE DAMPERSURFACE MOUNTSTANDPIPESTATIC PRESSURESTEAMTHERMOSTATTOP OF PIPETEMPERATURE DROPTRENCH DRAINTEMPERATURETYPICALUNDERGROUNDVACUUMVENTVARIABLE AIR VOLUMEVENTILATIONVENT THROUGH ROOFWASTEWET BULBWALL CLEAN OUTWALL HYDRANTEQUIPMENT ABBREVIATIONSACACCUAHUASBCHCTCUHCHWPDBPDCDCPDUEFEDCAIR CONDITIONING UNITAIR COOLING CONDENSING UNITAIR HANDLING UNITAIR SEPARATORBOILERCHILLERCOOLING TOWERCABINET UNIT HEATERCHILLED WATER PUMPDOMESTIC WATER BOOSTER PUMPDUCT MOUNTED COILDOMESTIC WATER CIRCULATING PUMPDISTRIBUTION (REFRIGERANT) UNITEXHAUST FANELECTRIC DUCT COILETEXPANSION TANKEWH ELECTRIC WATER HEATERFCU FAN COIL UNITFPFIRE PUMPGIGREASE INTERCEPTORGRV GRAVITY ROOF VENTILATORHWP HEATING WATER PUMPHRU HEAT RECOVERY UNITPRV POWER ROOF VENTILATORRERETURN/EXHAUST FANRTU ROOFTOP UNITSFSHOT FEEDERSPSUMP PUMPUHUNIT HEATERVRF-CP VRF CONTROL PANELWH WATER HEATER18"x18" L/A18"x18" GE/A18"x18" SE/A6"Ø FLUE6"Ø C/ADROPDROPDROPDROPDROPDROPGENERAL RELIEF AIRGREASE EXHAUST AIRSMOKE EXHAUST AIREXHAUST GAS FLUECOMBUSTION AIRRECTANGULAR SUPPLY/OUTSIDE COMBUSTION AIR DUCT RISEROUND SUPPLY/OUTSIDE COMBUSTION AIR DUCT RISERECTANGULAR RETURN/TRANSFER AIR DUCT RISEROUND RETURN/TRANSFER AIR DUCT RISERECTANGULAR EXHAUST/RELIEF/SMOKE/GREASE/FLUE AIRDUCT RISEROUND EXHAUST/RELIEF/SMOKE/GREASE/FLUE AIR DUCT RISEINTERNAL ACOUSTICALLY 1.5" LINED DUCTWORKTYPE (SEE SCHEDULE)SUPPLY DIFFUSERGRILLES, REGISTERS & DIFFUSERS TAGA 4009X9CFMNECK SIZETYPE (SEE SCHEDULE)RETURN GRILLEB1 40012X12CFMNECK SIZETYPE (SEE SCHEDULE)EXHAUST GRILLEB 40010X10CFMNECK SIZETYPE (SEE SCHEDULE)LSD1 2001 / 4' - 0" / 8"LINEAR SLOTDIFFUSERLINEAR DIFFUSER TAGLSD1 2001 / 4' - 0" / 8"8' - 0"AFFCFMNUMBER OF SLOTS /ACTIVE SLOT LENGTH (PLENUM LENGTH) /NECK SIZEELEVATION (CENTER OF FACE)LSD1 2001 / 4' - 0" / 8"HEATINGCOILFLOWVAV-XXHtg: 3.7 GPMVAV BOXBOTTOM OF EQUIPMENTELEVATIONMECHANICAL EQUIPMENT TAGSVAV-XX10' - 0"OPERATING WEIGHTNOT INCLUDING CURBRTU-XX4.0 tonRTU-XX590 lbEXISTING VAV BOXTO REMAINVAV LABELMAX CFMEXISTING RELOCATEDEQUIPMENTVAV-S-3355/155(R)VAV-XXNOMINAL COOLINGCAPACITYMIN CFM FUEL INPUTGAS PIPE FLOWROOFTOP UNITRTU-XX115000 Btu/h115 CFHEQUIPMENT BY OTHERS(REFER TO OTHER DISCIPLINEFOR ADDITIONAL INFORMATION)VAV-XXCOMB. FIRE/SMOKE DAMPERFIRE DAMPERSMOKE DAMPER12"x12" S/ASD FDDAMPER TAGSF/SDVD MMANUAL BALANCING DAMPERMOTORIZED DAMPERBACKDRAFT DAMPERBD12"x12" S/APIPING SYMBOLSCHWRCHWSCCWCWRCWSDFORFOSGWRGWSHWRHRRHWSGPGRLRSRHGSTMSCRMPSMPRSHWRSHWSTHWRTHWSTFORTFOSTPRVDPIPE ANCHORCHILLED WATER RETURNCHILLED WATER SUPPLYCONDENSATE DRAINCOLD MAKEUP WATERCONDENSER WATER RETURNCONDENSER WATER SUPPLYDRAINFUEL OIL RETURNFUEL OIL SUPPLYGEOTHERMAL WATER RETURNGEOTHERMAL WATER SUPPLYHEATING WATER RETURNHEAT RECOVERY RETURNHEATING WATER SUPPLYNATURAL GASPROPANE GASREFRIGERANT-LIQUIDREFRIGERANT-SUCTIONREFRIGERANT-HOT GASLOW PRESSURE STEAMLOW PRESSURE STEAM CONDENSATE RETURNMEDIUM PRESSURE STEAMMEDIUM PRESSURE STEAM CONDENSATE RETURNSCHEDULED HOT WATER RETURNSCHEDULED HOT WATER SUPPLYTEMPORARY HEATING WATER RETURNTEMPORARY HEATING WATER SUPPLYTEMPORARY FUEL OIL RETURNTEMPORARY FUEL OIL SUPPLYTEMPORARY PRESSURE RELIEF VALVE DISCHARGEPIPE GUIDESBLIND FLANGE (BF)PIPE TEE DOWNIN-LINE EXPANSIONCOMPENSATORSTEAM TRAP ASSEMBLYSTEEL PENETRATION /PIPE SLEEVEPIPE ELBOW UPTAKEOFF FROM TOPOF MAIN PIPETAKEOFF FROMBOTTOM OF MAINPIPEDIRECTION OF FLUIDFLOWAIR VENTCOMPANION FLANGEPIPE ELBOW DOWNPIPE CAP (CAP)UNIONBALL VALVEPRESSUREREGULATORBUTTERFLY VALVEVALVES AND FITTINGSMLOCK SHIELD VALVEPRESSUREMREDUCING VALVEY-STRAINER2-WAY CONTROL VALVE3-WAY CONTROL VALVESAFETY RELIEF VALVECHECK VALVEBALANCING VALVE SQUICK OPENING VALVESOLENOID VALVEGATE VALVEPLUG VALVEGLOBE VALVEGAS SHUTOFF COCKCONTROLS SYMBOLSWCWIRED CONTROLLERDSDUCT SMOKE DETECTORAOANALOG OUTPUTAIANALOG INPUTBOBINARY OUTPUTBIBINARY INPUTFSFLOW SWITCHPSSTATIC PRESSURE SENSORFGM NATURAL GAS FLOW METERFOM OIL FLOW METERNGM NATIONAL GRID NATURALGAS METERWM WATER METERFILTER SECTIONSPSTATIC PRESSURE SENSOR - HIGH LIMITHSPSTATIC PRESSURE SENSOR - LOW LIMITLTTHERMOSTATHEATING COILTSTEMPERATURE SENSORT/CO2 THERMOSTAT & CARBON DIOXIDE SENSORCOOLING COILT/RH THERMOSTAT & RELATIVE HUMIDITY SENSORRHRELATIVE HUMIDITY SENSORCO2 CARBON DIOXIDE SENSORH2HYDROGEN SENSORNO2 NITROGEN DIOXIDE SENSORCOCARBON MONOXIDE SENSORCOCARBON MONOXIDE &NO2 NITROGEN DIOXIDE SENSORSTARTERTBMS TEMPERATURE SENSORIN THERMOWELLTHERMOMETER INTHERMOWELLT/PTEMPERATURE/PRESSURE GAUGEMMOTORIZED DAMPER -PARALLEL BLADESMMOTORIZED DAMPER -OPPOSED BLADES* NOTE *ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS INTHIS SET.THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BEUSED IN THIS SET OF DRAWINGS.FVDBYPVARIABLE FREQUENCY DRIVE(VFD) WITH MANUAL BYPASSFANPUMPPROJECT:GENERAL MECHANICAL NOTES1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETEAND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND ASREQUIRED BY CODE.2. VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE BEGINNING ANY WORK. COORDINATE NEWWORK WITH THE OWNER PRIOR TO COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SIGNIFIESACCEPTANCE OF CONDITIONS.3. CONTRACT DOCUMENT DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE ANDGENERAL ARRANGEMENT ONLY. PROVIDE ADDITIONAL DUCTWORK, PIPING, AND THEIR FITTINGS.4. MAINTAIN CLEAR ACCESS TO SERVICE EQUIPMENT AND OTHER ACCESSORIES REQUIRING SERVICE,VISUAL INSPECTION OR HAND OPERATION. WHERE INDICATED OR REQUIRED, PROVIDE ACCESS PANELSOF THE TYPE SELECTED TO SUIT MATERIALS IN WHICH INSTALLED.5. ADJUST DUCTWORK SIZES TO PROPERLY CONNECT TO MECHANICAL EQUIPMENT.6. LOCATIONS, DUCTWORK, PIPING, AND EQUIPMENT AS INDICATED ON THE DRAWING, ARE APPROXIMATEAND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL BE COORDINATED WITH ALL OTHERTRADES TO AVOID INTERFERENCE IN THE FIELD.7. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH WRITTENMANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE CODES ANDREGULATIONS.8. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE ANDELECTRICAL SPECIFICATIONS.9. ALL PRESSURES LISTED ARE GAUGE UNLESS OTHERWISE NOTED.10. PRIOR TO STARTING WORK, SUBMIT SHOP DRAWINGS AND SUBMITTALS FOR ALL MECHANICALEQUIPMENT, DUCTWORK, DAMPERS, PIPING, PIPING FITTINGS, VALVES, INSULATION, PIPING ANDDUCTWORK SUPPORTS, AND CONTROLS.11. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS AND SHALL ARRANGE FOR ALLREQUIRED INSPECTIONS.12. PROVIDE ONE YEAR WARRANTY FOR ALL WORKMANSHIP AND MATERIALS AFTER THE DATE OF FINALACCEPTANCE. REFER TO MECHANICAL SPECIFICATIONS FOR EQUIPMENT EXTENDED WARRANTYREQUIREMENTS.13. FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL CONFORM TO ALLREQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL CODES.14. MECHANICAL CONTRACTOR SHALL COORDINATE ALL HVAC EQUIPMENT (VOLTAGE, PHASE, ETC.) WITHTHE ELECTRICAL CONTRACTOR PRIOR TO ORDER OF ANY MECHANICAL EQUIPMENT. MECHANICALCONTRACTOR SHALL BE RESPONSIBLE FOR ANY MISMATCH BETWEEN MECHANICAL EQUIPMENT,ELECTRICAL REQUIREMENTS AND THE ELECTRICAL SERVICE, AS DESIGNED. MECHANICAL ANDELECTRICAL COORDINATION STATEMENTS SHALL BE INCLUDED WITH EQUIPMENT SUBMITTALS ANDELECTRICAL REQUIREMENTS AND THE ELECTRICAL SERVICE, AS DESIGNED. MECHANICAL ANDELECTRICAL COORDINATION STATEMENTS SHALL BE INCLUDED WITH EQUIPMENT SUBMITTALS ANDSHOP DRAWINGS.15. THE MECHANICAL CONTRACTOR SHALL PROVIDE FULL SUPPORT TO THE COMMISSIONING AGENTTHROUGHOUT ALL PHASES OF THE COMMISSIONING PROCESS INCLUDING PREPARATION, FUNCTIONALTESTING, DOCUMENTATION, AND RESOLUTION OF DEFICIENCIES.APPLICABLE CODES2022 BUILDING CODE OF CONNECTICUT2021 FIRE CODE OF CONNECTICUT2022 MECHANICAL CODE OF CONNECTICUT2022 ENERGY CONSERVATION CONSTRUCTION CODE OF CONNECTICUT2022 PLUMBING CODE OF CONNECTICUT2022 EXISTING BUILDING CODE OF CONNECTICUTAPPLICABLE LOCAL LAWS AND CODESHVAC ENERGY CODE COMPLIANCEMECHANICAL DESIGN COMPLIES WITH THE FOLLOWING SECTIONS OFTHE 2022 ENERGY CONSERVATION CONSTRUCTION CODE OF CONNECTICUT:1. C403.1.12. C403.2.23. C403.3.14. C403.3.25. C403.4.16. C403.12.2.17. C403.12.38. C403.12.3.1Edward L. SmithLibrary HVACReplacement3 Old Post RoadNorthford, CT06472MEP/FP ENGINEERS:919 Middle StreetMiddletown, CT06457(860) 635-7740www.aiengineers.comDISCLAIMER:THIS DOCUMENT CONTAINS PROPRIETARY INFORMATIONBELONGING TO AI ENGINEERS OR ITS AFFILIATEDCOMPANIES AND SHALL BE USED ONLY FOR THEPURPOSE FOR WHICH IT WAS SUPPLIED. IT SHALL NOT BECOPIED, REPRODUCED OR OTHERWISE USED, NOR SHALLSUCH INFORMATION BE FURNISHED IN WHOLE OR IN PARTTO OTHERS EXCEPT IN ACCORDANCE WITH THE TERMSOF ANY AGREEMENT UNDER WHICH IT WAS SUPPLIED, ORWITH THE PRIOR WRITTEN CONSENT OF AI ENGINEERS,AND SHALL BE RETURNED UPON REQUEST.ISSUANCE:# DATE1 01-16-26DESCRIPTIONBID DOCUMENTSLOCATION PLANN NOT TO SCALECONSTRUCTIONSTAGE AREASEAL:DRAWING TITLE:MECHANICAL NOTES,SYMBOLS, ANDABBREVIATIONSDATE: 01-16-25DRAWN BY: HBCHECKED BY: OASCALE:NTSJOB #:4465DRAWING #:M001EXISTING 1 1/4" CUP TO REMAINMECHANICAL DEMOLITION WORK GENERAL NOTES:1. LOCATION AND QUANTITIES OF EQUIPMENT IS BASED ON THE BEST AVAILABLE INFORMATION AT TIME OF DESIGN. THE DEMOLITION WORK SHALLINCLUDE PROVIDING ALL MATERIALS AND LABOR FOR EXTENSIONS, CONNECTIONS, CUTTING, PATCHING, REPAIRING, ELECTRICAL WORK, ANDTEMPORARY CONNECTIONS REQUIRED TO MAINTAIN SERVICE PENDING THE COMPLETION OF THE PERMANENT WORK. NOTES AND GRAPHICREPRESENTATION SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED. EXTENT OF THE DEMOLITION WORK SHALL BE COORDINATED WITHOWNER AND ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS PRIOR TO THE SUBMISSION OF HIS BID.2. DEMOLITION WORK SHALL NOT AFFECT OPERATION OF ANY EXISTING BUILDING SYSTEMS, BUT IF ANY EXISTING WORK REQUIRED TO REMAIN BUTINTERFERING WITH NEW WORK SHALL BE RELOCATED AND RECONNECTED USING LIKE MATERIALS AND METHODS OF THE EXISTING SERVICE ANDSHALL CONFORM TO CONTRACT DOCUMENTS. COORDINATE DEMOLITION WORK AND SHUT DOWN OF THE EXISTING HVAC SYSTEMS WITH ALL TRADES,UTILITY COMPANIES, AND THE OWNER 10 BUSINESS DAYS PRIOR TO COMMENCEMENT OF WORK.3. PROTECT THE INTEGRITY OF ALL ITEMS THAT ARE INDICATED TO REMAIN. WHERE ITEMS THAT ARE INDICATED TO REMAIN ARE NOT IN PROPERWORKING ORDER PRIOR THE START OF NEW WORK, REPORT ANY ISSUES IMMEDIATELY TO THE ENGINEER OF RECORD AND THE OWNER'SREPRESENTATIVE.4. EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE PROTECTION EQUIPMENT REQUIREMENTS SHALL BE MAINTAINED. COVER ALLFIRE ALARM DEVICES DURING CONSTRUCTION HOURS THEN AT END OF EACH WORKING DAY UNCOVER AND CLEAN THEM.5. MAKE SAFE ANY UNPROTECTED, EXPOSED ELECTRICAL WIRING AT A POINT OF DEMOLITION. CAPS SHALL BE AIRTIGHT OR WATERTIGHT DEPENDINGON TYPE OF SERVICE.6. RESTORE EXISTING FIREPROOFING DUE TO DEMOLITION SCOPE OF WORK.7. DEMOLITION MATERIALS REQUIRED TO BE TURNED OVER TO THE OWNER SHALL BE PLACED IN A MUTUALLY ACCEPTABLE LOCATION COORDINATEDWITH THE OWNER'S REPRESENTATIVE. OTHERWISE, THE DEMOLITION MATERIALS INCLUDING REFRIGERANT, SHALL BE REMOVED FROM THE BUILDINGAND DISPOSED IN ACCORDANCE WITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS. MATERIALS SHALL BE REMOVED FROM THE BUILDINGAFTER REGULAR BUSINESS HOURS AND SHALL BE TAKEN OFF-SITE NO LATER THAN THE START OF THE NEXT BUSINESS DAY. DEBRIS SHALL NOT BEALLOWED TO ACCUMULATE ON THE SITE. MECHANICAL ROOMS SHALL BE SWEPT CLEANED EACH DAY. DUST OR DEBRIS SHALL NOT BE PERMITTED TOENTER EXISTING FLOOR DRAINS AND SPACES ADJACENT TO MECHANICAL ROOMS.8. CONTRACTOR SHALL PROVIDE A SUBMITTED PLAN TO PROTECT EXISTING MEP SYSTEMS/EQUIPMENT, WALLS, CEILINGS, CARPETS, FLOORS,FURNITURE, IT EQUIPMENT AND BOOKS DURING CONSTRUCTION FOR OWNER APPROVAL.9. PATCH WALL TO MATCH EXISTING CONDITIONS WHERE EXISTING WIRED CONTROLLERS ARE REMOVED AND NEW WIRED CONTROLLERS NOT BEINSTALLED IN SAME LOCATION.EXISTING FIREDAMPER TOREMAIN, TYPICALEXISTING 1" CDOWN TOJANITOR SINKTO REMAINEXISTING 8X20 O/A UPAND FIRE DAMPER TOREMAIN. REMOVE DUCT6" BELOW UPPER FLOOR.CRAWL SPACEB-15REMOVE EXISTING 6HEAT PUMP HP-8REMOVE EXISTING 1" CAND WYE FITTINGCONNECTINGEXISTING 6X8 E/AUP TO REMAINCONDENSATE TO SINKDRAINEXISTING 8X4 E/ASTOBR-A03GE18X6 R/ASTORY AREAB-04WC1027WCTO REMAIN1127DATA/STORAGEB-11T 15FD18X6 S/AFD27EXISTING 10X619DIFFUSER AND FIREDAMPER TO REMAIN.CAP DUCTWORK.MEN'SROOMB-13 2718X6 S/AWOMEN'SROOMB-1427PASSAGE2710X6S/A23121X06X6S/SA/A10X6 S/ACO2 1614OFBF-I0C2E8X4 S/A DN.CIRCULATION DESK27FDB-12B-01FDFD2715827ELEV.MACH.ROOM FDB-09FDFDFD FD27 277JANITOR ROOMB-08212513WCERU-49EF-324STACK AREAB-072327STACK AREA27B-0627232323EXISTING TRANSFER AIRGRILLES AND FIRE DAMPERTO REMAIN, TYPICAL2312WC4 HP-423DU-22223ELEV.EXISTING 1 1/4"C UP TO REMAIN5 HP-31" C23HP-5T231" C311/4" CCOND-126 28 CAP1 1/4 " C181 1/4 " C202020HP-6 21" CEXISTING 1 1/4" CUP TO REMAINSTAIR10523COND-2292630CAP2712Φ E/A10X10 E/A2730EXISTING 1 1/4" CUP TO REMAINEXISTING E/ALOUVER TO REMAINEXISTING BUILDING COLUMNENCLOSURE TO REMAIN, TYPICALMECHANICAL DEMO WORK KEY NOTES1 REMOVE EXISTING CEILING CASSETTE UNIT HP-7 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.2REMOVE EXISTING O/A DUCTED HEAT PUMP UNIT HP-6 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.REMOVE EXISTING O/A DUCTED HEAT PUMP UNIT HP-5 WITH SUPPORT, DUCTWORK, CONDENSATE3 PIPING AND CONTROL WIRING WITH SUPPORT.REMOVE EXISTING O/A DUCTED HEAT PUMP UNIT HP-4 WITH SUPPORT, DUCTWORK, CONDENSATE4 PIPING AND CONTROL WIRING WITH SUPPORT.5REMOVE EXISTING O/A DUCTED HEAT PUMP UNIT HP-3 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.6REMOVE EXISTING O/A DUCTED HEAT PUMP UNIT HP-8 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.7 REMOVE EXISTING WALL-MOUNTED CASSETTE UNIT HP-1 WITH SUPPORT, DUCTWORK,CONDENSATE PIPING AND CONTROL WIRING WITH SUPPORT.1HP-78 REMOVE EXISTING WALL-MOUNTED CASSETTE UNIT HP-2 WITH SUPPORT, DUCTWORK,CONDENSATE PIPING AND CONTROL WIRING WITH SUPPORT.9 REMOVE EXISTING ERU-4 WITH SUPPORT, DUCTWORK, CONTROL WIRING AND ACCESSORIES WITHSUPPORT.1" CREADING AREAB-0517 EWH-110REMOVE EXISTING WIRED CONTROLLER WITH CONTROL WIRING SERVING HP-8 AND SUPPORT.INSTALL 316 SS PLATE #4 FINISH IN PLACE OF SENSOR.11 REMOVE EXISTING WIRED CONTROLLER WITH CONTROL WIRING SERVING HP-6 AND HP-7 ANDSUPPORT. INSTALL 316 SS PLATE #4 FINISH IN PLACE OF SENSOR.12 REMOVE EXISTING WIRED CONTROLLER WITH CONTROL WIRING SERVING HP-3, HP-4, AND HP-5AND SUPPORT. INSTALL 316 SS PLATE #4 FINISH IN PLACE OF SENSOR.13 REMOVE EXISTING WIRED CONTROLLER WITH CONTROL WIRING SERVING HP-1 AND HP-2 ANDSUPPORT. INSTALL 316 SS PLATE #4 FINISH IN PLACE OF SENSOR.EXISTING 1 1/4" CUP TO REMAIN14 REMOVE EXISTING ERU-4 CO2 SENSOR WITH CONTROL WIRING WITH SUPPORT.15 REMOVE EXISTING ELECTRIC DUCT HEATER IN ITS ENTIRETY WITH SUPPORT, THERMOSTAT, ANDCONTROL WIRING.16 REMOVE EXISTING ERU-4 WIRED CONTROLLER WITH CONTROL WIRING. INSTALL 316 SS PLATE #4FINISH IN PLACE OF SENSOR.17 REMOVE EXISTING ELECTRIC WALL HEATER EWH-1. EXISTING BACKBOX AND SUPPORT TO REMAIN.18 REMOVE EXISTING ELECTRIC WALL HEATER EWH-2. EXISTING BACKBOX AND SUPPORT TO REMAIN.19 REMOVE EXISTING ELECTRIC WALL HEATER EWH-6. EXISTING BACKBOX AND SUPPORT TO REMAIN.20 REMOVE EXISTING RADIANT CEILING PANEL WITH CONTROL WIRING AND SUPPORT.21 REMOVE EXISTING ELECTRIC WALL HEATER EWH-3. EXISTING BACKBOX AND SUPPORT TO REMAIN.22 REMOVE EXISTING BRANCH SELECTOR UNIT DU-2 WITH SUPPORT, CONDENSATE PIPING ANDCONTROL WIRING WITH SUPPORT.REMOVE EXISTING REFRIGERANT SUCTION AND REFRIGERANT LIQUID PIPING WITH SUPPORTS.23 NOTE: EACH DASHED DEMO LINE REPRESENTS TWO EXISTING PIPING LINES.24 REMOVE EXISTING EXHAUST FAN EF-3, EXHAUST FAN SUPPORT, CONTROL WIRING ANDDUCTWORK WITH SUPPORT.25 REMOVE EXISTING ACCESS PANEL TO CRAWL SPACE WITH FRAME.26 REMOVE EXISTING CONCRETE PAD, CONDENSING UNIT, PIPING AND WIRING WITH SUPPORT.27 EXISTING DUCTWORK TO REMAIN.28 REMOVE EXISTING CONDENSING UNIT COND-1 WITH REFRIGERANT PIPING, CONTROL, CONTROLWIRING, AND SUPPORT.29 REMOVE EXISTING CONDENSING UNIT COND-2 WITH REFRIGERANT PIPING, CONTROL, CONTROLWIRING, AND SUPPORT.30 REMOVE, CLEAN AND STORE EXISTING EQUIPMENT SCREEN FOR REINSTALLATION.PROJECT:Edward L. SmithLibrary HVACReplacement3 Old Post RoadNorthford, CT06472MEP/FP ENGINEERS:919 Middle StreetMiddletown, CT06457(860) 635-7740www.aiengineers.comDISCLAIMER:THIS DOCUMENT CONTAINS PROPRIETARY INFORMATIONBELONGING TO AI ENGINEERS OR ITS AFFILIATEDCOMPANIES AND SHALL BE USED ONLY FOR THEPURPOSE FOR WHICH IT WAS SUPPLIED. IT SHALL NOT BECOPIED, REPRODUCED OR OTHERWISE USED, NOR SHALLSUCH INFORMATION BE FURNISHED IN WHOLE OR IN PARTTO OTHERS EXCEPT IN ACCORDANCE WITH THE TERMSOF ANY AGREEMENT UNDER WHICH IT WAS SUPPLIED, ORWITH THE PRIOR WRITTEN CONSENT OF AI ENGINEERS,AND SHALL BE RETURNED UPON REQUEST.ISSUANCE:# DATE1 01-16-26DESCRIPTIONBID DOCUMENTSSEAL:DRAWING TITLE:MECHANICALLOWER LEVEL PLAN -DEMOLITION WORKDATE: 01-16-25DRAWN BY: HBCHECKED BY: OASCALE:AS NOTEDJOB #:4465DRAWING #:MD1011-1/4"C DN TOREMAINEXISTING ACCESSDOOR TO ATTIC TOREMAINEXISTING E/ALOUVER TOREMAINMECHANICAL DEMOLITION WORK GENERAL NOTES:PROJECT:1. LOCATION AND QUANTITIES OF EQUIPMENT IS BASED ON THE BEST AVAILABLE INFORMATION AT TIME OF DESIGN. THE DEMOLITION WORK SHALLINCLUDE PROVIDING ALL MATERIALS AND LABOR FOR EXTENSIONS, CONNECTIONS, CUTTING, PATCHING, REPAIRING, ELECTRICAL WORK, ANDTEMPORARY CONNECTIONS REQUIRED TO MAINTAIN SERVICE PENDING THE COMPLETION OF THE PERMANENT WORK. NOTES AND GRAPHICREPRESENTATION SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED. EXTENT OF THE DEMOLITION WORK SHALL BE COORDINATED WITHOWNER AND ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS PRIOR TO THE SUBMISSION OF HIS BID.2. DEMOLITION WORK SHALL NOT AFFECT OPERATION OF ANY EXISTING BUILDING SYSTEMS, BUT IF ANY EXISTING WORK REQUIRED TO REMAIN BUTINTERFERING WITH NEW WORK SHALL BE RELOCATED AND RECONNECTED USING LIKE MATERIALS AND METHODS OF THE EXISTING SERVICE ANDSHALL CONFORM TO CONTRACT DOCUMENTS. COORDINATE DEMOLITION WORK AND SHUT DOWN OF THE EXISTING HVAC SYSTEMS WITH ALL TRADES,UTILITY COMPANIES, AND THE OWNER 10 BUSINESS DAYS PRIOR TO COMMENCEMENT OF WORK.3. PROTECT THE INTEGRITY OF ALL ITEMS THAT ARE INDICATED TO REMAIN. WHERE ITEMS THAT ARE INDICATED TO REMAIN ARE NOT IN PROPERWORKING ORDER PRIOR THE START OF NEW WORK, REPORT ANY ISSUES IMMEDIATELY TO THE ENGINEER OF RECORD AND THE OWNER'SREPRESENTATIVE.4. EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE PROTECTION EQUIPMENT REQUIREMENTS SHALL BE MAINTAINED. COVER ALLFIRE ALARM DEVICES DURING CONSTRUCTION HOURS THEN AT END OF EACH WORKING DAY UNCOVER AND CLEAN THEM.5. MAKE SAFE ANY UNPROTECTED, EXPOSED ELECTRICAL CONTROL WIRING AT A POINT OF DEMOLITION. CAPS SHALL BE AIRTIGHT OR WATERTIGHTDEPENDING ON TYPE OF SERVICE.6. RESTORE EXISTING FIREPROOFING DUE TO DEMOLITION SCOPE OF WORK.7. DEMOLITION MATERIALS REQUIRED TO BE TURNED OVER TO THE OWNER SHALL BE PLACED IN A MUTUALLY ACCEPTABLE LOCATION COORDINATEDWITH THE OWNER'S REPRESENTATIVE. OTHERWISE, THE DEMOLITION MATERIALS INCLUDING REFRIGERANT, SHALL BE REMOVED FROM THE BUILDINGAND DISPOSED IN ACCORDANCE WITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS. MATERIALS SHALL BE REMOVED FROM THE BUILDINGAFTER REGULAR BUSINESS HOURS AND SHALL BE TAKEN OFF-SITE NO LATER THAN THE START OF THE NEXT BUSINESS DAY. DEBRIS SHALL NOT BEALLOWED TO ACCUMULATE ON THE SITE. MECHANICAL ROOMS SHALL BE SWEPT CLEANED EACH DAY. DUST OR DEBRIS SHALL NOT BE PERMITTED TOENTER EXISTING FLOOR DRAINS AND SPACES ADJACENT TO MECHANICAL ROOMS.Edward L. SmithLibrary HVACReplacement3 Old Post RoadNorthford, CT06472MEP/FP ENGINEERS:8. CONTRACTOR SHALL PROVIDE A SUBMITTED PLAN TO PROTECT EXISTING MEP SYSTEMS/EQUIPMENT, WALLS, CEILINGS, CARPETS, FLOORS,FURNITURE, IT EQUIPMENT AND BOOKS DURING CONSTRUCTION FOR OWNER APPROVAL.9. PATCH WALL TO MATCH EXISTING CONDITIONS WHERE EXISTING WIRED CONTROLLERS ARE REMOVED AND NEW WIRED CONTROLLERS NOT BEINSTALLED IN SAME LOCATION.MECHANICAL DEMO WORK KEY NOTES8X20 O/A DNTO REMAIN1610X4161HP-92ERU-31"C1618X6EXISTING E/A LOUVERTO REMAINREMOVE EXISTING 1"C DNAND WYE FITTINGCONNECTING CONDENSATETO SINK DRAIN6BREAKROOM1121610X68WC1612X5 EF-23312X516STORAGE113HP-1118X8918X6167TWC CO28X6106 LIBRARIAN11OFFICE111ADULT31CIRCULATION111MEN11516128X616EF-3 32WOMEN1141216HP-1314COMMUNITYROOM1021331VESTIBULE101ADULT FICTION1061414HP-181517WWCCCOC1O272CIRCULATION DESKB-01HP-15253114T6"Ø161" C12X61612X6HP-17161614X6STACKAREA10414X61616EXISTING 1 1/4" CDN. TO REMAINOFFICE10318WC191"C2012X6EXISTING O/ALOUVER TO REMAINWC218"Ø24HP-16311"CERU-112X612X6ERU-2232212X6SEMINAR116CAPCAP16510X6COPYAREA10916420X8WC16X618X610"Ø16313114X616ELEV.3012X61"C28 HP-122914WCT3131STACKAREA10727DU-11-1/4" C3HP-10161"CADULTREADING/REFERENCE108161618X6EXISTING1-1/4" C DN TOREMAIN311414CAPEXISTING O/ALOUVER TO REMAINEXISTING BUILDING COLUMNENCLOSURE TO REMAINCAP PIPING AT WALL ANDABANDON EXISTING RS & RLPIPING RISERS IN PLACEHP2-164STAIR10531CAP141 1/4" CEXISTING 1" C DN31TO REMAINEXISTING 1 1/4" CDN TO REMAINEXISTING E/ALOUVER TO REMAIN1 REMOVE EXISTING CEILING CASSETTE UNIT HP-9 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.2 REMOVE EXISTING ERU-3 WITH SUPPORT, DUCTWORK, CONTROL WIRING AND ACCESSORIESWITH SUPPORT.3 REMOVE EXISTING CEILING CASSETTE UNIT HP-10 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.4 REMOVE EXISTING WIRED CONTROLLERS WITH CONTROL WIRING WITH SUPPORT FOR HP-9 ANDHP-10. INSTALL 316 SS PLATE #4 FINISH IN PLACE OF CONTROLLERS.5 REMOVE EXISTING ELECTRIC WALL HEATER EWH-5 AND SUPPORT.6 REMOVE EXISTING 1.5kW ELECTRIC BASEBOARD RADIATOR WITH SUPPORT.7 REMOVE EXISTING THERMOSTAT AND CONTROL WIRING AND SUPPORT. INSTALL 316 SS PLATE#4 FINISH IN PLACE OF THERMOSTAT.8 REMOVE EXISTING WIRED CONTROLLER WITH CONTROL WIRING FOR HP-11. INSTALL 316 SSPLATE #4 FINISH IN PLACE OF CONTROLLER.9 REMOVE EXISTING O/A DUCTED HEAT PUMP UNIT HP-11 WITH SUPPORT, DUCTWORK,CONDENSATE PIPING AND CONTROL WIRING WITH SUPPORT.10 REMOVE EXISTING THERMOSTAT AND CO2 SENSOR WITH CONTROL WIRING AND SUPPORT.INSTALL 316 SS PLATE #4 FINISH IN PLACE OF SENSORS.11REMOVE EXISTING ERU FILTER SENSORS WITH CONTROL WIRING AND SUPPORT. INSTALL 316 SSPLATE #4 FINISH IN PLACE OF SENSORS.12 REMOVE EXISTING 750W ELECTRIC BASEBOARD RADIATION.13 REMOVE EXISTING ELECTRIC WALL HEATER EWH-4 AND SUPPORT.14 REMOVE EXISTING RADIANT CEILING PANEL WITH THERMOSTAT, CONTROL WIRING ANDSUPPORT. INSTALL 316 SS PLATE #4 FINISH IN PLACE OF SENSORS.REMOVE EXISTING CEILING CASSETTE UNIT HP-18 WITH SUPPORT, CONDENSATE PIPING AND15 CONTROL WIRING WITH SUPPORT.16 EXISTING DUCTWORK TO REMAIN.17 REMOVE EXISTING WIRED CONTROLLER, CO2 SENSOR AND CONTROL WIRING.18 REMOVE EXISTING WIRED CONTROLLER AND CONTROL WIRING WITH SUPPORT FOR HP-17.19 REMOVE EXISTING CEILING CASSETTE UNIT HP-17 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING AND SUPPORT.20 REMOVE EXISTING ERU-1 WITH SUPPORT, DUCTWORK, CONTROL WIRING AND ACCESSORIESWITH SUPPORT.21 REMOVE EXISTING WIRED CONTROLLER AND CONTROL WIRING FOR HP-16 AND SUPPORT.INSTALL 316 SS PLATE #4 FINISH IN PLACE OF CONTROLLER.22 REMOVE EXISTING ERU-2 WITH SUPPORT, DUCTWORK, CONTROL WIRING AND ACCESSORIESWITH SUPPORT.23 REMOVE EXISTING 1.5kW ELECTRIC BASEBOARD RADIATION.24 REMOVE EXISTING CEILING CASSETTE UNIT HP-16 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.25 REMOVE EXISTING CEILING CASSETTE UNIT HP-15 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.919 Middle StreetMiddletown, CT06457(860) 635-7740www.aiengineers.comDISCLAIMER:THIS DOCUMENT CONTAINS PROPRIETARY INFORMATIONBELONGING TO AI ENGINEERS OR ITS AFFILIATEDCOMPANIES AND SHALL BE USED ONLY FOR THEPURPOSE FOR WHICH IT WAS SUPPLIED. IT SHALL NOT BECOPIED, REPRODUCED OR OTHERWISE USED, NOR SHALLSUCH INFORMATION BE FURNISHED IN WHOLE OR IN PARTTO OTHERS EXCEPT IN ACCORDANCE WITH THE TERMSOF ANY AGREEMENT UNDER WHICH IT WAS SUPPLIED, ORWITH THE PRIOR WRITTEN CONSENT OF AI ENGINEERS,AND SHALL BE RETURNED UPON REQUEST.ISSUANCE:# DATE1 01-16-26DESCRIPTIONBID DOCUMENTSSEAL:26 REMOVE EXISTING CEILING CASSETTE UNIT HP-14 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING WITH SUPPORT.27 REMOVE EXISTING BRANCH SELECTOR UNIT DU-1 WITH SUPPORT, CONDENSATE PIPING ANDCONTROL WIRING WITH SUPPORT.28 REMOVE EXISTING CEILING CASSETTE UNIT HP-12 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING.29 REMOVE EXISTING WIRED CONTROLLERS WITH SUPPORT AND CONTROL WIRING FOR HP-12 ANDHP-13. INSTALL 316 SS PLATE #4 FINISH IN PLACE OF CONTROLLERS.30REMOVE EXISTING CEILING CASSETTE UNIT HP-13 WITH SUPPORT, DUCTWORK, CONDENSATEPIPING AND CONTROL WIRING.31 REMOVE EXISTING REFRIGERANT SUCTION AND REFRIGERANT LIQUID PIPING WITH SUPPORTS.NOTE: EACH DASHED DEMO LINE REPRESENTS TWO EXISTING PIPING LINES.DRAWING TITLE:MECHANICALUPPER LEVEL PLAN -DEMOLITION WORK32 REMOVE EXISTING EXHAUST FAN EF-1, EXHAUST FAN SUPPORT, CONTROL WIRING ANDDUCTWORK WITH SUPPORT.33 REMOVE EXISTING EXHAUST FAN EF-2, EXHAUST FAN SUPPORT, CONTROL WIRING ANDDUCTWORK WITH SUPPORT.DATE: 01-16-25DRAWN BY: HBCHECKED BY: OASCALE:AS NOTEDJOB #:4465DRAWING #:MD102PROJECT:MECHANICAL NEW WORK GENERAL NOTES:MECHANICAL NEW WORK KEY NOTES1. BEFORE SUBMITTING THE BID, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BECOME FULLY FAMILIAR WITH THE EXISTING CONDITIONS AND THEDOCUMENTS OF OTHER TRADES UNDER WHICH HIS WORK WILL BE ACCOMPLISHED. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANYASSUMPTIONS, OMISSIONS OR ERRORS HE MADE AS A RESULT OF FAILURE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS.2. THIS DRAWING IS DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED TO DETERMINE THE EXACT LOCATION OR EXTENT OF THE WORK. EXACT PIPINGAND DUCTWORK ROUTING, DUCTWORK AND PIPING LENGTHS TO BE VERIFIED IN FIELD.THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONSPRIOR TO THE START OF THE NEW WORK. COORDINATE NEW WORK SCOPE OF WORK WITH ALL TRADES, DEMOLITION SCOPE OF WORK AND THE OWNER.3. IF ANY EXISTING WORK REQUIRED TO REMAIN BUT INTERFERING WITH NEW WORK SHALL BE RELOCATED AND RECONNECTED USING LIKE MATERIALSAND METHODS OF THE EXISTING SERVICE AND SHALL CONFORM TO CONTRACT DOCUMENTS. THE CONTRACTOR SHOULD INCLUDE ALL NECESSARYPREMIUM TIME TO PERFORM NEW WORK IN HIS BID. COORDINATE NEW WORK AND SHUT DOWN OF THE EXISTING HVAC SYSTEMS WITH ALL TRADES,UTILITY COMPANY, AND THE OWNER TEN DAYS PRIOR TO COMMENCEMENT OF WORK.4. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE COMPLETE AND FULLY OPERATIONAL HVAC SYSTEMS.5. INSTALL, SUPPORT & BRACE NEW DUCTWORK AND ACCESSORIES PER SMACNA GUIDELINES.6. INSTALL EQUIPMENT IN STRICT ACCORDANCE WITH WRITTEN MANUFACTURER'S RECOMMENDATIONS.7. PROVIDE REQUIRED ACCESS & CLEARANCES AROUND ALL EQUIPMENT IN STRICT ACCORDANCE WITH WRITTEN MANUFACTURER'S RECOMMENDATIONS.8. CONTRACTOR SHALL ENGAGE A TESTING AND BALANCING FIRM CERTIFIED BY AABC TO PERFORM TESTING AND BALANCING PROCEDURES ON EACHSYSTEM ACCORDING TO THE PROCEDURES AS CONTAINED IN AABC'S NATIONAL STANDARDS. PROVIDE THREE COPIES OF THE CERTIFIED TAB REPORTS.9. COORDINATE DUCTWORK AND PIPING WITH EXISTING CONDITIONS AND ELECTRICAL PANELS AND CONDUITS.10.PROVIDE FIREPROOFING AT PIPING AND DUCTWORK PENETRATIONS THROUGH FIRE RATED WALLS. RESTORE EXISTING FIREPROOFING TO ORIGINALCONDITIONS.11.MAINTAIN A MINIMUM DISTANCE OF 10'-0" BETWEEN EXHAUST AIR, ALL PLUMBING VENTS AND MECHANICAL AIR INTAKES.12.REFER TO PIPING AND DUCTWORK DETAILS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.13.PIPING SHALL NOT BE INSTALLED ABOVE VFDS.14.PROVIDE SEISMIC RESTRAINT FOR SPECIFIED EQUIPMENT AND PIPING PER SPECIFICATION SECTION 230548 REQUIREMENTS.15.EXECUTE NEW WORK IN A SAFE MANNER. EGRESS, EXITS AND FIRE PROTECTION EQUIPMENT REQUIREMENTS SHALL BE MAINTAINED. COVER ALL FIREALARM DEVICES DURING CONSTRUCTION HOURS THEN AT END OF EACH WORKING DAY, UNCOVER AND CLEAN THEM.16.CONTRACTOR SHALL PROVIDE A SUBMITTED PLAN TO PROTECT EXISTING MEP SYSTEMS/EQUIPMENT, WALLS, CEILINGS, CARPETS, FLOORS, FURNITURE,IT EQUIPMENT AND BOOKS DURING CONSTRUCTION FOR OWNER APPROVAL.1 PROVIDE TYPE B1 LAY-IN DIFFUSER WITH 20 X 20 NECK FOR REFRIGERANT DISPERSAL IN THE EVENT OF A LEAK AT DU-1. COORDINATE DIFFUSERPLACEMENT WITH EXISTING CONDITIONS AND THE INSTALLED LOCATION OF DU-1.2 PROVIDE CONDENSING UNIT ACCU-1. PROVIDE CONCRETE PAD AND W21 GALVANIZED STEEL BEAM. REFER TO DWG M404 FOR ADDITIONAL INFO.3 PROVIDE CONDENSING UNIT ACCU-2. PROVIDE CONCRETE PAD AND W21 GALVANIZED STEEL BEAM. REFER TO DWG M404 FOR ADDITIONAL INFO.PROVIDE 12" W X 20" L X 3" H CONCRETE SPLASH BLOCK AND PITCH AWAY FROM BUILDING AND CONDENSING UNITS. REMOVE EXISTING 45 DEG SLOPED4 FITTING WITH MESH SCREEN AND EXTEND CONDENSATE PIPING AS SHOWN TO SPLASH BLOCK. PROVIDE MESH SCREEN AT PIPING TERMINATION.5 PROVIDE 1/2" RL, 1 1/8" RS, AND 7/8" HRR WITH SUPPORT.6 PROVIDE 1/2" RL, 7/8" RS, AND 3/4" HRR WITH SUPPORT.7 PROVIDE 1/2" RL, 1 1/8" RS, AND 1 1/8" HRR WITH SUPPORT.8 PROVIDE 3/8" RL AND 5/8" RS WITH SUPPORT.9 PROVIDE 1/4" RL AND 1/2" RS WITH SUPPORT.10 PROVIDE EF-1 AND DUCT FLEXIBLE CONNECTIONS. PROVIDE GALVANIZED STEEL UNISTRUT TO SUPPORT EF-1 FROM EXISTING STRUCTURE. PROVIDEREQUIRED SERVICE CLEARANCE TO EF-1.11 PROVIDE WALL-MOUNTED HEAT PUMP UNIT HP-1 WITH MOUNTING PLATE, GALVANIZED STEEL SUPPORT, REFRIGERANT PIPING, CONDENSATE PIPING,CONDENSATE PUMP WITH CONDENSATE DRAIN PAN, AND CONTROL WIRING. INSTALL CONDENSATE PUMP ON WALL NEXT TO HEAT PUMP. PROVIDEREMOVABLE PVC (COLOR: WHITE) PUMP COVER, AFFIX TO WALL. INSTALL ALL PIPING IN EXISTING WALL CAVITY.12 PROVIDE WALL-MOUNTED HEAT PUMP UNIT HP-2 WITH MOUNTING PLATE, GALVANIZED STEEL SUPPORT, REFRIGERANT PIPING, CONDENSATE PIPING,CONDENSATE PUMP WITH CONDENSATE DRAIN PAN, AND CONTROL WIRING. INSTALL CONDENSATE PUMP ON WALL NEXT TO HEAT PUMP. PROVIDEREMOVABLE PVC (COLOR: WHITE) PUMP COVER, AFFIX TO WALL. INSTALL ALL PIPING IN EXISTING WALL CAVITY.13 PROVIDE O/A DUCTED HEAT PUMP UNIT HP-3 WITH REFRIGERANT PIPING, CONDENSATE PIPING, AND CONTROL WIRING. PROVIDE GALVANIZED STEELUNISTRUT SUPPORT.14 PROVIDE O/A DUCTED HEAT PUMP UNIT HP-4 WITH REFRIGERANT PIPING, CONDENSATE PIPING, AND CONTROL WIRING. PROVIDE GALVANIZED STEELUNISTRUT SUPPORT.Edward L. SmithLibrary HVACReplacement3 Old Post RoadNorthford, CT06472MEP/FP ENGINEERS:919 Middle StreetMiddletown, CT06457(860) 635-7740www.aiengineers.com15 PROVIDE O/A DUCTED HEAT PUMP UNIT HP-5 WITH REFRIGERANT PIPING, CONDENSATE PIPING, AND CONTROL WIRING. PROVIDE GALVANIZED STEELUNISTRUT SUPPORT.EXISTING 1" CDOWN TOJANITOR SINKINSTALL EDH-1CONTROL PANELPROVIDE CF-1DATA/STORAGEB-11B-10X6120 CFM41FDFD120 CFM41EXISTING6X8 E/A UPTFD18X6 S/AFD TO EDH-12312X4 S/AVDFD EDH-1FD 2012A 2009X99111STACK AREAB-07PROVIDE18X6 R/A41 350 CFMVD8X6 S/ASTOBR-A0G3 E 1836WC 34STORY AREAB-04EXISTING 8X4 E/A4180 CFM120 CFMMEN'SWOMEN'SROOM4110X6 S/AROOMB-14B-1380 CFM80 CFM41 4110X6 S/A121X06XV6SD/SA/A8X6 S/A300 CFM418X4 S/A DN.18X6 S/APASSAGEOFBF-I0C2E1CIRCULATION DESKB-128B-01414110041100CFM100CFMCFMSTACK AREA8B-062691" C UPWC30 TO HP-710041 CFM35351 1/4" C17HP-71"C UP1" C UP8TO HP-62635 1 1/4" C29WC16 HP-6261 1/4" CREADING AREAB-05E2W1 H-1T16 PROVIDE O/A DUCTED HEAT PUMP UNIT HP-6 WITH REFRIGERANT PIPING, CONDENSATE PIPING, AND CONTROL WIRING. PROVIDE GALVANIZED STEELUNISTRUT SUPPORT.17 PROVIDE HEAT PUMP UNIT HP-7 WITH REFRIGERANT PIPING, CONDENSATE PIPING, AND CONTROL WIRING. PROVIDE GALVANIZED STEEL UNISTRUTSUPPORT.18 PROVIDE O/A DUCTED HEAT PUMP UNIT HP-8 WITH DUCTWORK, DUCTWORK TRANSITIONS, DUCT FLEXIBLE CONNECTIONS, REFRIGERANT PIPING, ANDCONDENSATE PIPING. PROVIDE GALVANIZED STEEL UNISTRUT SUPPORT.19 PROVIDE ERU-1. PROVIDE GALVANIZED STEEL UNISTRUT SUPPORT. PROVIDE REQUIRED SERVICE CLEARANCE TO ERU-1.20 PROVIDE FIRE DAMPER AND ELECTRIC DUCT HEATER DEH-1 WITH REMOTE CONTROL PANEL AND SUPPORT.21 PROVIDE ELECTRIC WALL HEATER EWH-1. REUSE EXISTING BACKBOX AND SUPPORT.22 PROVIDE ELECTRIC WALL HEATER EWH-2. REUSE EXISTING BACKBOX AND SUPPORT.23 PROVIDE ELECTRIC WALL HEATER EWH-6. REUSE EXISTING BACKBOX AND SUPPORT.24 PROVIDE ELECTRIC RADIANT HEATING PANEL AND SUPPORT.25 REINSTALL ACCESS PANEL TO CRAWL SPACE WITH FRAME AFTER START-UP OF ERU-1 AND EF-1.26 REUSE EXISTING BEAM PENETRATIONS.27 PROVIDE ELECTRIC WALL HEATER EWH-3. REUSE EXISTING BACKBOX AND SUPPORT.28 PROVIDE BRANCH SELECTOR UNIT DU-1 AND SUPPORT. PROVIDE REQUIRED SERVICE CLEARANCE AS SHOWN.29 PROVIDE WIRED CONTROLLER AND CONTROL WIRING FOR HP-6.DISCLAIMER:THIS DOCUMENT CONTAINS PROPRIETARY INFORMATIONBELONGING TO AI ENGINEERS OR ITS AFFILIATEDCOMPANIES AND SHALL BE USED ONLY FOR THEPURPOSE FOR WHICH IT WAS SUPPLIED. IT SHALL NOT BECOPIED, REPRODUCED OR OTHERWISE USED, NOR SHALLSUCH INFORMATION BE FURNISHED IN WHOLE OR IN PARTTO OTHERS EXCEPT IN ACCORDANCE WITH THE TERMSOF ANY AGREEMENT UNDER WHICH IT WAS SUPPLIED, ORWITH THE PRIOR WRITTEN CONSENT OF AI ENGINEERS,AND SHALL BE RETURNED UPON REQUEST.FD FDPROVIDE18X6 E/AELEV. CAPMACH.ROOM FDB 100VD 6X6JANITOR ROOM 9135 HP-4 1482631TO HP-426 35B-09TB 20010X10FDTO EF-125B-08PS27TO HP-1AND HP-2210 CFMWC269DU-128395STAIRTO ECRP-1,105ECRP-2, ECRP-314X14 O/A TOEXISTING8X20 O/A UPFD45°WC334EXISTING FD40PROVIDE8X8 E/AEF-11019ERU-1PROVIDE 8Φ E/AELEV.PROVIDE 12Φ S/AAND EWH-2353515HP-5T37382ACCU-113HP-3 1 1/4" C263532WC811/4" C537264542PROVIDE10X6 E/APROVIDE12Φ E/A3ACCU-23871 1/4 " C181 1/4 " CECRP-124TO HP-326AND HP-5ECRP-2 24ECRP-3245B-10X6 37EXISTING1 1/4"C DN.30 PROVIDE WIRED CONTROLLER AND CONTROL WIRING FOR HP-7.31 PROVIDE WIRED CONTROLLER AND CONTROL WIRING FOR HP-4.32 PROVIDE WIRED CONTROLLER AND CONTROL WIRING FOR HP-3 AND HP-5.33 PROVIDE WIRED CONTROLLER AND CONTROL WIRING FOR HP-1 AND HP-2.34 PROVIDE WIRED CONTROLLER AND CONTROL WIRING FOR HP-8.35 PROVIDE 1 1/4"C.36 PROVIDE 1 1/4"C. PROVIDE WYE ADAPTER WITH 1 1/4" TAILPIECE. VERIFY EXISTING SINK DRAIN SIZE.37 NEW STORAGE CLOSET WALLS AND DOOR SHALL BE FURNISHED AND INSTALLED BY THE TOWN OF NORTH BRANFORD. MECHANICAL CONTRACTOR SHALLPROVIDE AND COORDINATE INSTALLATION OF TRANSFER GRILLES ON EACH SIDE OF WALL (ONE SET OF GRILLES 6" AFF AND SECOND SET OF GRILLES 6"BELOW CEILING SERVING STORAGE ROOM WITH THE TOWN.38 NEW ENCLOSURE (WITH BRICK PATTERN) FOR EXTERIOR REFRIGERANT RISERS ALONGSIDE BUILDING TO BE FURNISHED BY THE TOWN OF NORTHBRANFORD AND INSTALLED BY THE MECHANICAL CONTRACTOR.39 PROVIDE SOUNDPROOF WRAPPING ON FIRST 5' OF EACH PIPING CONNECTION TO DU-1.ISSUANCE:# DATE1 01-16-26DESCRIPTIONBID DOCUMENTSSEAL:CRAWL SPACEB-1556 742212Φ E/A4210X10 E/A40 PROVIDE DUCT FILTER SECTION MEETING THE FOLLOWING REQUIREMENTS: 22 GAUGE GALVANIZED STEEL CONSTRUCTION, GASKETED, HINGED, R-8LINED HOUSING ACCESS DOOR, AND 20X16 2" MERV-8 FILTER. CONTRACTOR SHALL INSULATE FILTER HOUSING WITH R-8 RIGID BOARD INSULATION.41 BALANCE EXISTING DUCTWORK/DIFFUSER TO SPECIFIED AIRFLOW.EXISTING E/ALOUVER42 REINSTALL EXISTING EQUIPMENT SCREEN.DRAWING TITLE:MECHANICALLOWER LEVEL PLAN -NEW WORKDATE: 01-16-25DRAWN BY: HBCHECKED BY: OASCALE:AS NOTEDJOB #:4465DRAWING #:M101
- Commodity Codes
-
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Storefront Modifications Storefront Modifications at 72 Church Street in New Haven. Start Date
State Government of Connecticut
Bid Due: 7/30/2026
PARKING LOT RECONSTRUCTION - ...
Project ID: 25/26-62 Title: PARKING LOT RECONSTRUCTION - SALTERS POOL PARKING LOT Addenda:
Town of Manchester
Bid Due: 7/23/2026