DAS CC Hoover Print Shop Expansion
Project Information
- Bid Title
- DAS CC Hoover Print Shop Expansion
- Issuing Agency
- State Government of Iowa
- Location
- Iowa
- Published Date
- Apr 30, 2026
- Closing Date
- May 19, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- RFB947300-01
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid InformationBid Number
RFB947300-01
Solicitation
DAS CC Hoover Print Shop Expansion
Solicitation Type
Request for Bids
CountyDescriptionDescription
The Iowa Department of Administrative Services will be receiving bids for DAS CC Hoover Print Shop Expansion, 1305 E Walnut St, Des Moines, IA 50319
**Full Size Project Manual Available for Download in IMAPCS**
Agency InformationNumber
005
Name
Administrative Services, Dept
Address 1
1305 E. Walnut St.
Address 2
City/State/Zip
Des Moines, IA 50319
Contact InformationContact Name
Construction Procurement
Contact Title
Michael Bradbury
Contact Email
Contact Phone Number
(515) 823-9327
Contact Phone Extension
Contact Other Number
Contact Fax NumberValid DatesFrom
4/30/2026 4:25:00 PM
Until
5/19/2026 2:00:00 PM
Documents/Attachments - Attachment Preview
-
GROUP100% CD SETState of IowaDAS Hoover Print Shop ExpansionDAS Project #9473.00 RFB 947300-01Hoover Building1305 East Walnut StreetDes Moines, IA 50319ARCHITECT / CONSULTANT LIST:FARNSWORTH GROUP - ARCHITECT14225 UNIVERSITY AVENUE, SUITE 110, WAUKEE, IOWA 50263PHONE: 515.225.3469KCL ENGINEERING300 4TH STREET, WEST DES MOINES, IOWA 50265PHONE: 515.724.7938LOCATION MAP1305 East Walnut StreetDRAWING LISTGENERAL*COG1.0Ph0.1Ph0.2Ph0.3COVERGENERAL INFORMATION & LIFE SAFETY PLANPHASE 1PHASE 2PHASE 3ARCHITECTURALAD1.1 DEMOLITION PLANSA1.1 FLOOR PLAN & REFLECTED CEILING PLANA7.1 DOOR & ROOM FINISH SCHEDULE, DOOR ELEVATIONS AND DETAILS, AND PARTITION TYPESA8.1 EQUIPMENT PLANFire Protection (F)F1.1 FIRST FLOOR PLAN - FIRE PROTECTIONPlumbing (P)PD1.1 FIRST FLOOR PLAN DEMOLITION - PLUMBINGP1.1 FIRST FLOOR PLAN - PLUMBINGP3.1 PLUMBING DETAILS AND SCHEDULESMechanical (M)M0.0 MECHANICAL GENERAL NOTES & SYMBOLSMD1.1 FIRST FLOOR PLAN DEMOLITION - HVACM1.1 FIRST FLOOR PLAN - HVACM3.1 MECHANICAL DETAILS AND SCHEDULESElectrical (E)E0.0 ELECTRICAL GENERAL NOTES & SYMBOLSE0.1 TECHNOLOGY GENERAL NOTES & SYMBOLSED1.1 ELECTRICAL DEMOLITION - LIGHTINGED1.2 ELECTRICAL DEMOLITION - POWER & SYSTEMSE1.1 ELECTRICAL POWERE2.1 ELECTRICAL LIGHTINGE3.1 ELECTRICAL TECHNOLOGYE4.1 ELECTRICAL ONE-LINE DIAGRAM & DETAILSE4.2 ELECTRICAL SCHEDULESE4.3 ELECTRICAL SCHEDULESEFA5.10.1 PFIHRAESDEE1TECTION & ALARM PLANSE5.1 PHASE 2FA1.1 FIRE DETECTION & ALARM PLANSIMAGE © < COPYRIGHT NOTICE >PROFESSIONAL REGISTRATIONSPROFESSIONALCHAD D.BASS21397IOWATHE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOWWAS PREPARED BY ME OR UNDER MY DIRECT PERSONALSUPERVISION. I AM A DULY LICENSED ARCHITECT UNDER THELAWS OF THE STATE OF IOWA.SIGNATURE:NAME: SARAH HUSTONDATE: 04/17/2026LICENSE RENEWAL DATE: 06/30/2026PAGES OR DIVISIONS COVERED:G AND A SERIESTHE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOWWAS PREPARED BY ME OR UNDER MY DIRECT PERSONALSUPERVISION. I AM A DULY LICENSED ENGINEER UNDER THELAWS OF THE STATE OF IOWA.SIGNATURE:NAME: CHAD BASSDATE: 04/17/2026LICENSE RENEWAL DATE:12/31/2027PAGES OR DIVISIONS COVERED:F, P, AND M SERIESPROFESSIONALERICHEYNENP24706IOWATHE PORTION OF THIS TECHNICAL SUBMISSION DESCRIBED BELOWWAS PREPARED BY ME OR UNDER MY DIRECT PERSONALSUPERVISION. I AM A DULY LICENSED ENGINEER UNDER THELAWS OF THE STATE OF IOWA.SIGNATURE:NAME: ERIC HEYNENDATE: 04/17/2026LICENSE RENEWAL DATE: 12/31/2027PAGES OR DIVISIONS COVERED:_E__S_E_RIES and FA SHEETSYMBOLS LEGENDNOTE: NOT ALL SYMBOLS ARE USED IN CONSTRUCTION DOCUMENTS1A8.1DETAIL #WALL SECTION1A8.1ENLARGED CALLOUTSHEET #XX.X COLUMN GRID1A8.1DETAIL #BUILDING SECTIONPAGE #XX.XWALL GRID(REPRESENTSFACE OF EXISTINGWALL)1A8.1ALIGNALIGN1A8.1DETAIL #DETAIL SECTIONSHEET #1A8.1DETAIL #INTERIOR ELEVATIONSHEET #BREAK LINEELEVATION0'-0"ELEVATION1REVISION NOTEROOMNAME101ROOM DESIGNATIONARCHITECTUREB#CASEWORK TYPE0"-6"CHANGE IN LEVELMATL1'-0"CEILING/ SOFFITHEIGHTAL1GLAZING TYPE#.#KEYNOTED#.#126DEMOLITION KEYNOTEROOF PITCH1A8.1DOOR NUMBERDETAIL #EXTERIOR ELEVATIONSHEET #SLOPE: 1/4" SLOPE/ROOF SLOPET#TOILET ACCESSORY#WALL TYPEXXX-#XXX-#FINISH MATERIALTRANSITIONPROJECT NO.:02500979.00114225 University Avenue, Suite 110 - Waukee, Iowa 50263 - Phone: (515) 225-3469 / info@f-w.comDATE: 04/17/2026ABBREVIATIONSGENERALACTADJADT'LAFFALTAPPROXB/OBDBLDGBLKGBOTBRGC/CCEMCFCICFOICLCJCLGCLRCOLCONCCONSTCONTCTRDBLDEMODET/DTLDIADIMDNDWG(S)EEAECEHOELELECELEVEMEREQEQUIPEWEX/EXISTEXPEXTFDFDNFEFECFFEFINFLRFRMGFTFVGAGALVGCGENGYPHDWRHMHOLHORHTHVACIDACOUSTIC(AL) TILEADJUSTABLEADDITIONALABOVE FINISHED FLOORALTERNATEAPPROXIMATE(LY)BOTTOM OFBOARDBUILDINGBLOCKINGBOTTOMBEARINGCENTERLINECENTER TO CENTERCEMENT(ITIOUS)CONTRACTOR FURNISHED,CONTRACTOR INSTALLEDCONTRACTOR FURNISHED,INSTALLED BY OTHERSCONTROL JOINTCEILINGCLEARCOLUMNCONCRETECONSTRUCTIONCONTINUOUSCENTER(ED)DOUBLEDEMOLITIONDETAILDIAMETERDIMENSIONDOWNDRAWING(S)EASTEACHELECTRICAL CONTRACTORELECTRICAL HOLD OPENELEVATIONELECTRIC(AL)ELEVATOREMERGENCYEQUALEQUIPMENTEACH WAYEXISTINGEXPOSEDEXTERIORFLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFINISH FLOOR ELEVATIONFINISHFLOORFRAMINGFOOT/FEETFIELD VERIFYGAUGEGALVANIZEDGENERAL CONTRACTORGENERALGYPSUMHARDWAREHOLLOW METALHOLLOWHORIZONTALHEIGHTHEATING/VENTILATION/AIRCONDITIONINGINSIDE DIAMETERININCLINSULINTJTLAMLFLTMASMAT'LMAXMECHMFRMINMISCMTDMTLNNANICNOMNTSOCODOFCIOFCROFOIOPNGOPPOVHDPERIMPFINPLBGPLYWDPNTPTDPWRRBRECREINFREQ'DREVRDRMROSSFSIMSPECSQSSSTORSTRUCTSUSPSYT/OTYPUNFINUNOVERTVIFW/W/OWWCWDWHWTINCHINCLUDINGINSULATIONINTERIORJOINTPLASTIC LAMINATELINEAR FEET (FOOT)LIGHTMASONRYMATERIALMAXIMUMMECHANICALMANUFACTURERMINIMUMMISCELLANEOUSMOUNTEDMETALNORTHNOT APPLICABLENOT IN CONTRACTNOMINALNOT TO SCALEON CENTEROUTSIDE DIAMETEROWNER FURNISHED,CONTRACTOR INSTALLEDOWNER FURNISHED,CONTRACTOR ROUGH-INOWNER FURNISHED,INSTALLED BY OTHERSOPENINGOPPOSITEOVERHEADPERIMETERPREFINISHEDPLUMBINGPLYWOODPAINTPAINTEDPOWERRUBBER BASERECESSEDREINFORCEDREQUIREDREVISED (REVISION)ROOF DRAINROOMROUGH OPENINGSOUTHSQUARE FEET (FOOT)SIMILARSPECIFICATIONSSQUARESTAINLESS STEELSTORAGESTRUCTURALSUSPENDEDSQUARE YARD(S)TOP OFTYPICALUNFINISHEDUNLESS NOTED OTHERWISEVERTICALVERIFY IN FIELDWITHWITHOUTWESTWATER CLOSETWOODWATER HEATERWEIGHTINTERIORABACBACCACTAFAPARTBBTBRCCCCTCGCJCKBCONCPTCRCSCURDGEGEMFFRPGGRHBLHRLINLSLVTMBMPNSPPLQTZALUMINUM WALL BASEACOUSTICAL CEILING BAFFLEACOUSTICAL CEILING CLOUDACOUSTICAL CEILING TILEARCHITECTURAL FILMACOUSTIC PANELARTWORKBIOBASED RESILIENT TILEBRICK / VENEER BRICKCUBICLE CURTAINCUBICLE CURTAIN TRACKCORNER GUARDCONTROL JOINTCORKBOARDCONCRETE FLOORING / FINISHCARPETCRASH RAILCULTURED STONEDECORATIVE CURTAIN / RODDOOR FRAME GUARDEND WALL GUARDENTRY MAT SYSTEMFABRICFIBERGLASS REINFORCEDPANEL(S)GLASS / GLAZINGGROUTHORIZONTAL BLINDSHAND RAILLINOLEUM SHEET / TILELOUVER SYSTEMLUXURY VINYL TILEMOLDED WALL BASEMETAL PANELNATURAL STONEPAINTPLASTIC LAMINATEQUARTZRBRFRPRSRUBRUGSSCSCRSDSHTSSSSTSSVSTSVSVTTTPTRTSTZVALVBLVCTVETWCWCTWDWFWPWRRESILIENT WALL BASERESINOUS POURED FLOORINGRESIN / ACRYLIC PANELROLLER SHADERUBBER SHEET / TILERUG CARPETINGSIGNAGESHOWER CURTAINSHOWER CURTAIN RODSTATIC DISSIPATIVE FLOORINGSHUTTERSOLID SURFACESTAINLESS STEELSPECIALTY SHEET VINYLSTAINSHEET VINYLSPECIALTY VINYL TILETILE FLOORING/ WALL / WALLBASE (CERAMIC, PORCELAIN,GLASS)TOILET PARTITIONTRIM / CROWN / BASE MOLDINGTRANSITION STRIPTERRAZZO FLOORINGVALANCEVERTICAL BLINDSVINYL COMPOSITION TILEVINYL ENHANCED TILEWALL COVERINGWOOD CEILING TILE / PLANKWOOD (VENEER, PANELING,WAINSCOT, FLOORING)WINDOW FILMWALL PROTECTIONWHITEROCKSTANDARD MOUNTING HEIGHTSCORNER GUARD3" TO CORNERGUARDOR DOOR FRAMEFIBERREINFORCEDPANELSWALL PROTECTION4'-0" TO TOP OFCABINET - IF FIREEXTINGUISHEROVER 40 LBS3'-6" HT.FIRE EXTINGUISHERCABINETOCCUPANT LOAD TABLENUMBERNAMEOCCUPANCYTYPEAREALEVEL A FLOORHA62HALLWAY164 SFHA64GRAPHIC DESIGN OFFICES BUS978 SFHA66PRODUCTION / PRINT ROOM BUS3175 SFHA68WARRANT STORAGESTG32 SFHA70PAPER STORAGES-1634 SFHA72BINDERY / LETTERSHOPBUS4498 SFHA74OVERNIGHT STORAGESTG82 SFHC01GENERATOR1592 SFHC02MECHANICAL1067 SFTOTAL:12222 SFOCCUPANCY OCCUPANTFACTORLOAD150 SF7150 SF22300 SF1300 SF3150 SF30300 SF164REMARKSGRAPHICDESIGNOFFICES978 SFBUS150 7EXITCLR CAPACITY33" 165EXITCLR CAPACITY33" 165FECEXITCLR CAPACITY33" 165WARRANTSTORAGE32 SFSTG300 1PRODUCTION/ PRINTROOM3175 SFBUS150 22EXITCLR CAPACITY33" 165EXITCLR CAPACITY68" 340PAPERSTORAGE634 SFS-1300 3BINDERY/LETTERSHOP4498 SFBUS150 30EXITCLR CAPACITY68" 340EXITCLR CAPACITY68" 340FECOVERNIGHTSTORAGE82 SFSTG300 1PROJECT GENERAL NOTESA. REFER TO GENERAL INFORMATION SHEETS FOR SYMBOLS AND ABBREVIATIONS.B. WALLS TO BE REMOVED SHALL BE FROM FLOOR TO STRUCTURE ABOVE UNLESSOTHERWISE INDICATED AND SHALL INCLUDE ALL MECHANICAL, ELECTRICAL,ETC. PREPARE ALL DISTURBED AREAS FOR NEW CONSTRUCTION.C. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS. IF A REQUIREDDIMENSION IS NOT INDICATED, CONTACT THE ARCHITECT FOR DETERMINATION.D. THE CONTRACTOR SHALL NOT CUT STRUCTURAL MEMBERS/ELEMENTS IN AMANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY ORLOAD/DEFLECTION RATIO.E. PAINT ALL STEEL DOORS, DOOR FRAMES, INTERIOR BORROW LITE FRAMES,LINTELS AND OTHER EXPOSED METAL ITEMS UNLESS OTHERWISE NOTED ORSHOWN.F. EXISTING CONDITION INFORMATION SHOWN WITHIN THE PROJECT AREA ISBASED ON FIELD OBSERVATION AND EXISTING DRAWING DOCUMENTATION. ALLEXISTING CONDITION INFORMATION SHOWN OUTSIDE THE PROJECT AREA ISPROVIDED FOR REFERENCE ONLY AND HAS NOT BEEN FIELD VERIFIED.CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONSPRIOR TO BEGINNING ANY NEW WORK AND SHALL BRING AND DISCREPANCIESTO THE ATTENTION OF THE DESIGN PROFESSIONAL PRIOR TO DEMOLITION ANDCONSTRUCTION.G. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS IS UNDERSTOOD TONOT BE WITHIN THE BUILDING. STORAGE OF ANY MATERIAL IS TO BE INCOMPLIANCE WITH ALL APPLICABLE CODES AND AUTHORITIES HAVINGJURISDICTION.LIFE SAFETY GENERAL NOTESA. REFER TO ELECTRICAL DRAWINGS FOR FIRE ALARMNOTIFICATION AND EMERGENCY EGRESS LIGHTINGLOCATIONS.B. REFER TO PARTITION TYPES FOR FURTHER FIRESEPARATION REQUIREMENTS.C. ALL FIRE RATED ASSEMBLIES SHALL BE INSTALLED INSTRICT ACCORDANCE WITH TESTED ASSEMBLIESINDICATED.D. WHERE A RATING HAS BEEN GIVEN TO AN EXISTING WALL,ALL PENETRATIONS (EXISTING OR NEW) SHALL BE SEALEDAND PROPERLY FIREPROOFED PER THAT RATINGREQUIREMENT.LIFE SAFETY LEGENDFIRE RATINGS2FB2 HOUR FIRE BARRIER WALL2FW2 HOUR FIRE WALLEGRESSTRAVEL DISTANCE TO AN EXITGROUP14225 UNIVERSITY AVENUE, SUITE 110WAUKEE, IOWA 50263(515) 225-3469 / info@f-w.comwww.f-w.comEngineers | Architects | Surveyors | ScientistsARCHITECTURAL GENERAL NOTESA. REFER TO LIFE SAFETY SHEETS FOR LIFE SAFETY INFORMATION.B. CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING NECESSARY FOR ALLOPENINGS AND SUPPLEMENTAL FRAMING ABOVE PARTITIONS.C. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES FOR SYSTEM RELATEDPENETRATIONS NOT SHOWN.D. CONTRACTOR SHALL MAINTAIN THE BUILDING IN A WEATHERPROOF CONDITIONAT ALL TIMES.E. PROJECTS SHALL REMAIN IN COMPLIANCE WITH ALL ASPECTS OF ALLGOVERNING CODES AND ORDINANCES DURING THE COURSE OFCONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EXITING, FIRE ALARMSYSTEM(S) SMOKE/FIRE DETECTION SYSTEM(S), SPRINKLER SYSTEM(S).F. TEMPORARY BARRICADES SHALL BE INSTALLED BY CONTRACTOR AT AREAS OFWORK TO CONTAIN CONSTRUCTION ACTIVITY AND TO PREVENT UNAUTHORIZEDPERSONS FROM ENTERING THE WORK AREA. COORDINATE LOCATIONS WITHOWNER.G. ALL AREAS TO BE DEMOLISHED OR DISTURBED BY ANY DEMOLITION ARE TO BEPATCHED AND PAINTED (OR PREPARED FOR OTHER SCHEDULED FINISH). IFPAINTING IS REQUIRED, ENTIRE WALL SHALL RECEIVE PAINT TO AVOIDMISMATCH OF COLOR.H. ALL OPENINGS AND VOIDS LEFT BY THE REMOVAL OF EXISTING CONSTRUCTION,EQUIPMENT, PIPING, DUCTS, ETC, SHALL BE PROPERLY PATCHED AND CLOSEDOFF TO MAINTAIN PROPER FIRE RATING IN AFFECTED WALL, FLOOR, OR ROOF.PREPARE PATCHED AREAS TO RECEIVE NEW FINISHES AS SCHEDULES (ORMATCH EXISTING FINISHES IF NOT OTHERWISE IDENTIFIED).I. WHEN PATCH OF EXISTING FLOOR IS REQUIRED, SLOPING OR RAMPING INEXCESS OF CONTRACT TOLERANCES WILL NOT BE ALLOWED (1/8" PER 10 FEETMAXIMUM).J. UPON REMOVAL OF TEMPORARY PARTITIONS, CONTRACTOR IS RESPONSIBLEFOR PATCHING TO MATCH EXISTING ADJACENT CONSTRUCTION.K. AT CONSTRUCTION ACCESS, CONTRACTOR TO PROVIDE LABOR AND MATERIALSTO REPAIR ALL DISTURBED ELEMENTS.L. REMOVAL OF CERAMIC TILE AND GROUT BEDS FROM EXISTING WALLS ANDFLOOR SHALL INCLUDE PREPARATION FOR NEW CONSTRUCTION.M. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO PROVIDE COMPLETEWORKING SYSTEMS FOR ALL NEW ELEMENTS AND TO COORDINATE THEIRWORK WITH ALL OTHER TRADES.N. ALL CONTRACTORS SHALL PROVIDE NEW, UNDAMAGED MATERIALS UNLESSOTHERWISE SPECIFIED.O. STORE MATERIALS IN SUCH A MANNER AS NOT TO OVERSTRESS, OVERLOAD, OROTHERWISE PUT AN UNSAFE LOAD ON ANY STRUCTURE DURINGCONSTRUCTION.P. INSTALL ALL WORK IN ACCORDANCE WITH CURRENT APPLICABLE CODES,PUBLISHED STANDARDS, AND ACCEPTABLE CONSTRUCTION STANDARDS.Q. DETAILS ARE GENERALLY TYPICAL AND ARE NOT TO BE CONSTRUED AS LIMITEDTO THOSE AREAS SPECIFICALLY INDICATED. REVIEW ANY QUESTIONS ORCONFLICTING INFORMATION WITH THE DESIGN PROFESSIONAL PRIOR TOFABRICATION OR INSTALLATION.R. CONTRACTOR SHALL VERIFY DIMENSIONS IN FIELD PRIOR TO BEGINNINGCONSTRUCTION.S. HINGE SIDE OF DOOR JAMBS TO BE LOCATED 4” FROM NEAREST WALLINTERSECTION UNLESS OTHERWISE NOTED.DEFERRED SUBMITTALSTHE FOLLOWING SYSTEMS ARE A DESIGN/BUILD RESPONSIBILITY OF THECONTRACTOR OR PRODUCT MANUFACTURER AND WILL REQUIRE THE DEFERREDSUBMITTAL OF DESIGN WORK TO THE AUTHORITY HAVING JURISDICTION FOR PLANREVIEW AND PERMITTING:1. FIRE SPRINKLER SYSTEMS2. FIRE ALARM SYSTEMSXXEXITIDENTIFICATIONEGRESS CLEARWIDTHCOMMON PATH OF TRAVELDEAD END CORRIDOREGRESS PATH TAGEXTERIOREXITCLR CAPACITY0" 180EGRESS CAPACITY300 4th StWest Des Moines, IA50265515-724-7938ISSUE:# DATE: DESCRIPTION:OCCUPANCYName150 SFXXXX000 00ROOM NAMEROOM AREAOCCUPANCY TYPEOCCUPANCY LOAD USEDOCCUPANCY LOAD FACTORMISCELLANEOUSFECFIRE EXTINGUISHER CABINETCODE INFORMATIONHOOVER PRINT SHOP EXPANSION1305 E WALNUT STREETDES MOINES, IOWA 50319WORK DESCRIPTIONINTERIOR RENOVATION AND EXPANSION OF EXISTING PRINTSHOP AND GRAPHIC DESIGN OFFICE INCLUDING PARTITIONWALLS, FINISHES, MECHANICAL, ELECTRICAL, LIGHTING,PLUMBING, AND FIRE ALARM SYSTEMS.APPLICABLE CODES2024 INTERNATIONAL BUILDING CODE2012 INTERNATIONAL ENERGY CONSERVATION CODESTATE MECHANICAL CODE2024 INTERNATIONAL FIRE CODESTATE ELECTRIC CODE (2023 NEC WITH AMENDMENTS)2012 NFPA LIFE SAFETY CODEICC A117.1 ACCESSIBILITY CODE2010 ADASTATE PLUMBING CODE100% CD SETPROJECT:State of IowaBUILDING CONSTRUCTION AND OCCUPANCYCONSTRUCTION TYPE: EXISTING BUILDINGPRIMARY OCCUPANCY: EXISTING TO REMAIN - GROUP BFIRE RATINGPRIMARY STRUCTURAL FRAME:EXISTING TO REMAINEXTERIOR BEARING WALLS:EXISTING TO REMAININTERIOR BEARING WALLS:EXISTING TO REMAINFLOOR CONST/SECONDARY MEMBERS: EXISTING TO REMAINCORRIDORS (X-OCCUPANCY):EXISTING TO REMAINELEVATOR SHAFTS:EXISTING TO REMAINELEVATOR MECHANICAL:EXISTING TO REMAINSTAIRS/EXIT ENCLOSURES:EXISTING TO REMAINBOILER AND FUEL-FIRED HEATER ROOM: EXISTING TO REMAINOCCUPANT LOADSOCCUPANCY - B: 8,725 SF @ 150 GSF/ PERSON = 59 PEOPLEOCCUPANCY - S: 114 SF @ 300 GSF/ PERSON = 2 PERSONOCCUPANCY - S-1: 634 SF @ 300 GSF/ PERSON = 3 PEOPLETOTAL: 64 PEOPLEEGRESSEXIT TRAVEL DISTANCE (CONST TYPE):___ FT MAXEXIT TRAVEL DISTANCE FROM POINTIN ROOM (CONST TYPE):___ FT MAXEXIT TRAVEL DISTANCE FROM DOOROF ROOM (CONST TYPE):___ FT MAXCOMMON PATH OF TRAVEL (CONST TYPE): ___ FT MAXCOMMON PATH OF TRAVEL (CONST TYPE)> # OCC =___ FT MAX≤ # OCC =___ FT MAXCOMMON PATH OF TRAVEL (CONST TYPE): ___ FT MAXDEAD END CORRIDORS (CONST TYPE):___ FT MAXEXIT TRAVEL DISTANCE TO SMOKECOMPARTMENT:___ FT MAXEGRESS CORRIDOR WIDTH:__" MIN, 0.2" x OCC LOADEGRESS DOOR WIDTH:32" MIN, 0.2" x OCC LOADEGRESS STAIR WIDTH:44" MIN, 0.3" x OCC LOADEGRESS PATH ADAS Hoover PrintShop ExpansionDAS Project #9473.00Hoover Building1305 East Walnut StreetDes Moines, IA 50319DATE:DESIGNED:DRAWN:REVIEWED:04/17/2026SLHNHDSLHSHEET TITLE:GENERALINFORMATION & LIFESAFETY PLANPATH IDATOTAL PATH LENGTHLENGTH112' - 1 5/16"112' - 1 5/16"SHEET NUMBER:LIFE SAFETY PLAN1SCALE: 3/32" = 1'-0"048PLAN16NORTHEGRESS PATH BPATH IDBTOTAL PATH LENGTHLENGTH67' - 8 9/32"67' - 8 9/32"G1.0PROJECT NO.:02500979.001GROUP14225 UNIVERSITY AVENUE, SUITE 110WAUKEE, IOWA 50263(515) 225-3469 / info@f-w.comwww.f-w.comEngineers | Architects | Surveyors | Scientists300 4th StWest Des Moines, IA50265515-724-7938ISSUE:# DATE: DESCRIPTION:PHASE 1: June - October, 2026- New work to be performed in the spaces shown in green.- Existing spaces and equipment shown in white are to remain in tact andoperation during phase one. This includes the current print shop andinserter room.- Erect temporary wall at the east end of the existing inserter room toaccomplish new work at the east end of the project.- Install temporary electrical connections in anticaption of equipmentrelocating during Phase 2.PHASING LEGEND:PHASE 1 WORK AREAPHASE 2 WORK AREAPHASE 3 WORK AREATEMPORARY WALLWSCANNON COLOR C1350WSOCE MICR 1INSERTER 2UPCANNON C9010WSOCE MICR 2WSSHRINKWRAPPERINSERTER 12'-0"100-501PHASE 1 - SCOPE PLANSCALE: 1/16" = 1'-0"100% CD SETNOT FOR CONSTRUCTIONPROJECT:State of IowaDAS Hoover PrintShop ExpansionDAS Project #9473.00Hoover Building1305 East Walnut StreetDes Moines, IA 50319DATE:DESIGNED:DRAWN:REVIEWED:04/17/2026DesignerAuthorApproverSHEET TITLE:PHASE 1SHEET NUMBER:Ph0.1PROJECT NO.:02500979.001GROUP14225 UNIVERSITY AVENUE, SUITE 110WAUKEE, IOWA 50263(515) 225-3469 / info@f-w.comwww.f-w.comEngineers | Architects | Surveyors | Scientists300 4th StWest Des Moines, IA50265515-724-7938ISSUE:# DATE: DESCRIPTION:PHASE 2: November, 2026 - January, 2027- New work to be performed in the spaces shown in blue.- Equipment to be relocated as shown and operation at these locationsduring Phase 2.- Coordinate equipment relocation and calibration with equipment supplier.- Maintain and erect temporary walls as needed to perform work.PHASING LEGEND:PHASE 1 WORK AREAPHASE 2 WORK AREAPHASE 3 WORK AREATEMPORARY WALL2'-0"2'-6"GRAPHICDESIGNOFFICESHA64PRODUCTION /PRINT ROOMHA66WS3'-6"INSERTER 1BINDERY /LETTERSHOPHA723'-3" CANNON C9010 3'-6"5'-0" OCE MICR 1WS2'-0"WSOCE MICR 2PAPERSTORAGEHA70SHRINKWRAPPERCUTTERFOLDERMECHANICALHC02UPGENERATORHC011 PHASE 2 - SCOPE PLANSCALE: 1/16" = 1'-0"100% CD SETNOT FOR CONSTRUCTIONPROJECT:State of IowaDAS Hoover PrintShop ExpansionDAS Project #9473.00Hoover Building1305 East Walnut StreetDes Moines, IA 50319DATE:DESIGNED:DRAWN:REVIEWED:04/17/2026DesignerAuthorApproverSHEET TITLE:PHASE 2SHEET NUMBER:Ph0.2PROJECT NO.:02500979.001GROUP14225 UNIVERSITY AVENUE, SUITE 110WAUKEE, IOWA 50263(515) 225-3469 / info@f-w.comwww.f-w.comEngineers | Architects | Surveyors | Scientists300 4th StWest Des Moines, IA50265515-724-7938ISSUE:# DATE: DESCRIPTION:PHASE 3: January, 2027- New work to be performed in the spaces shown in purple.- Equipment to be relocated to it's final location as shown on sheet A8.1.- Coordinate equipment relocation and calibration with equipment supplier.PHASING LEGEND:PHASE 1 WORK AREAPHASE 2 WORK AREAPHASE 3 WORK AREATEMPORARY WALLGRAPHICDESIGNOFFICESHA64PRODUCTION /PRINT ROOMHA661 PHASE 3 - SCOPE PLANSCALE: 1/16" = 1'-0"BINDERY /LETTERSHOPHA72PAPERSTORAGEHA70MECHANICALHC02UPGENERATORHC01100% CD SETNOT FOR CONSTRUCTIONPROJECT:State of IowaDAS Hoover PrintShop ExpansionDAS Project #9473.00Hoover Building1305 East Walnut StreetDes Moines, IA 50319DATE:DESIGNED:DRAWN:REVIEWED:04/17/2026DesignerAuthorApproverSHEET TITLE:PHASE 3SHEET NUMBER:Ph0.3PROJECT NO.:02500979.001
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Replacement of Two Passthroug...
Follow Replacement of Two Passthrough Autoclave/Sterilizers - National Animal Disease Center Active Contract
AGRICULTURE, DEPARTMENT OF
Bid Due: 7/06/2026
Circular Dichroism Spectrometer
Follow Circular Dichroism Spectrometer Active Contract Opportunity Notice ID 1232SA26Q0719 Related Notice Department/Ind.
AGRICULTURE, DEPARTMENT OF
Bid Due: 7/10/2026