Purchase of an Insertion-Type Magnetic Flow Meter
Project Information
- Bid Title
- Purchase of an Insertion-Type Magnetic Flow Meter
- Issuing Agency
- Mobile Water Service System(MAWSS)
- Location
- Alabama
- Published Date
- Apr 28, 2026
- Closing Date
- May 12, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- IFB 26-029
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Purchase of an Insertion-Type Magnetic Flow Meter
-
Contract or Solicitation Number IFB 26-029
-
Solicitation Description
-
Opening Date May 12th 2026
-
Contact Jett Byrne 251-342-1070 Ext. 1298or emal: jett.byrne@volkert.com
Markus Moore 251-721-0828 or email: mamoore@mawss.com -
Solicitation Document(s)
ifb-26-029-magnetic-flow-meter-purchase-gaillard-volkert-1201846.007.pdf
-
- Attachment Preview
-
Joyce Sawyer, Buyer II(251) 694-3110 Officejasawyer@mawss.comMobile Area Water andSewer System4725 Moffett RoadMobile, AL 36618-2236PO Box 180249Mobile, AL 36618-0249INVITATION FOR BIDApril 28, 2026INVITATION FOR BID NUMBERIFB 26-029PROJECT #1201846.007NAME OF BIDBIDS WILL BE RECEIVED ATBID OPENING DATEPurchase of an Insertion-Type Magnetic Flow MeterMAWSS Purchasing Dept. Bid BoxEast Visitor Entrance4725 Moffett RoadMobile, AL 36618If sending bids by UPS/Fed Ex, deliver to the Warehouse:1610 Shelton Beach Rd. Ext., Mobile, AL 36618with IFB# marked on envelopeMay 12, 2026BID CLOSING TIMEAWARD WILL BE MADE BYMATERIAL DELIVERED TO10:30 am Central TimeTotal Cost & Lead TimeGaillard Pumping Station 1450 Pumping Station Rd., Mobile, AL 36608STARTUP ADDRESSADDITIONAL INFORMATION CONTACTAPPLICABLE SDP POLICYRegulator House - 1203 Woodland Ave., Prichard, AL 36610Jett Byrne 251-342-1070 Ext. 1298 jett.byrne@volkert.comMarkus Moore 251-721-0828 mamoore@mawss.comNoneSealed bids must be in the Purchasing Department no later than the time specified in order to be considered. Submissionsreceived after the deadline will not be considered. Envelopes must bear the name of the supplier, company address and thewords “IFB 26-029 Flow Meter Purchase” or “IFB 26-029 NO QUOTE.” Facsimile or email bids will not be accepted.All bids must be submitted on the attached forms, or your bid will be disqualified. Bidder shall furnish all the informationrequired by the solicitation. The bidder’s name must be typed or printed on the bid sheet and signed by the bidder orappropriate authorized executive officer of the bidder’s company. Bidders must initial any changes or erasures. Bidders shouldretain a copy of bids for their records.Bidders shall acknowledge receipt of all addenda to this solicitation by signing and returning each addendum or by identifyingthe addendum number and the date on the bid form. Failure to acknowledge receipt of any addendum by a bidder will resultin rejection of the bid if MAWSS determines that the addendum contains information that materially changes the requirements.All bids shall be quoted FOB Destination, freight prepaid with no additional charges. Unless otherwise specified in the bid, allprices will be on a firm-fixed price basis and are not subject to adjustments based on costs incurred. MAWSS reserves the rightto reject any or all bids submitted, to waive any informality in any bid or in the bid process, or to terminate the bid process atany time, if deemed by MAWSS to be in MAWSS’s best interest.A Purchase Order and this “Invitation for Bid” with “Specifications,” “Conditions,” “Bid Form,” signed by the successful bidder’sauthorized representative, and all attached drawings and other documents furnished by MAWSS to the bidders with theInvitation for Bid in order to illustrate the contract requirements, will constitute a contract for the goods and/or services to bepurchased.IFB 26-029 Purchase of a Magnetic Flow MeterPage 1 of 8IFB 26-029 FLOW METER PURCHASECONDITIONSThe Board of Water and Sewer Commissioners of the City of Mobile will accept bids for the Flow Meter Purchase in ourPurchasing Department Bid Box located at the East Visitor Entrance at 4725 Moffett Road, Mobile, AL. 36618 no later than10:30 a.m. local time on May 12, 2026. Bids will be opened immediately after bid closing time in the Operations Center Boardroom located at the East Visitor Entrance. Award will be by Total Cost & Lead Time. The bidder offers and agrees, if this bid isaccepted, to furnish the items as defined in the specifications for the unit price set opposite each item. Pricing shall be FOBMobile, Alabama. All items shall be delivered to the Gaillard Pumping Station at 1450 Pumping Station Rd., Mobile, AL 36608or to the job site as needed. The bidder shall state the expected length of delivery time on the Bid Form.An optional site visit can be scheduled before bidding, if needed. Please contact Jett Byrne at 251-342-1070 Ext. 1298.Bidder understands and agrees that manufacturer and part numbers are provided for descriptive purposes only. Items of equalor better quality will be considered but must be approved by MAWSS in writing. Upon delivery, if the quality, durability orperformance of any product represented as equal or better is determined by MAWSS to be unsatisfactory, MAWSS will requirea suitable substitute or will require that the originally specified item be delivered, at the unit price originally offered by bidder.No substitution for items to be provided pursuant to this contract shall be permitted during the contract period without theexpress written consent of MAWSS. All items provided shall be for commercial use and for the purposes reflected in thecontract documents.No bid on closed out or discontinued item(s) will be accepted. Item(s) that have a determinable shelf life must be disclosed atthe time of bid submittal. Bidder understands that his/her bid shall be good and may not be withdrawn for a period of sixty(60) calendar days after the scheduled closing time for receiving bids.MAWSS reserves the right to reject any or all bids submitted, to waive any informality in any bid or in the bid process, or toterminate the bid process at any time, if deemed by MAWSS to be in MAWSS’s best interest.Bidder understands and agrees that quantities will be purchased by MAWSS on an “as needed” basis to replenish inventory.MAWSS shall not be committed to the purchase of a pre-established minimum quantity for any one item.A bidder may not modify its bid after bid opening. Errors in the extension of unit prices stated in a bid or in multiplication,division, addition or subtraction in a bid may be corrected by the MAWSS Purchasing Buyer prior to award. In such cases, unitprices shall not be changed.It is the responsibility of the bidder to determine prior to the bid opening whether any amendment, additions, deletions orchanges of any type have been made to this Invitation for Bid, Conditions, Specifications, Bid Form or any other bid documents.Bid documents and any amendments made to this bid will be posted on our website at www.mawss.com.Invoicing Requirements: Email invoices to Accounts Payable at AcctsPayable@mawss.com.END OF CONDITIONSIFB 26-029 Purchase of a Magnetic Flow MeterPage 2 of 8Mobile Area Water and Sewer SystemKimberly Clark Flow Meter StudyProject No. 1201846.007Purchase SpecificationApril 17, 2026SECTION 40 71 13.23INSERTION-TYPE MAGNETIC FLOW METERSPART 1 – GENERAL1.01 SCOPE OF WORKA. This Specification is intended for the purchase and delivery of the electromagnetic insertion-type flow meter and associated equipment described herein for the existing Mobile Area Waterand Sewer System raw water distribution system. Installation to be performed by the owner withtechnical support from the supplier.1.02 SUBMITTALA. The following information shall be included in the submittal for this section:1. Data sheets and catalog literature for the forward flow insertion-type magnetic flow meterand the microprocessor based signal converter.2. Connection diagrams for equipment wiring.3. List of spare parts and optional equipment.1.03 DELIVERY, STORAGE, & HANDLINGA. Ship equipment, material, and spare parts complete except where partial disassembly isrequired by transportation regulations, for protection of components, or for installationrequirements.B. Pack spare parts in containers bearing labels which clearly designate contents and pieces ofequipment for which they are intended.PART 2 – PRODUCTS2.01 MANUFACTURERSA. The electromagnetic insertion flow meter shall be McCrometer 395L for forward flow full profileinsertion mag meter or approved equal. Equivalency is determined by MAWSS and theEngineer’s review, and is not done prior to bid. If equivalency is a concern, bidders areencouraged to submit multiple bids.2.02 ELECTROMAGNETIC INSERTION FLOWMETERA. The electromagnetic insertion flow meter shall consist of a flow sensor based on Faraday’s Lawof Electromagnetic Induction and microprocessor-based signal converter.B. Sensor:1. Operating principle: Utilizing Faraday’s Law of Electromagnetic Induction, the flow of aconductive liquid around the sensor induces an electrical voltage that is proportional to thevelocity of the flow.2. Construction: The sensor material shall be constructed of 316 Stainless Steel and coatedwith NSF 61 certified approved epoxy coating.3. Sensor operating temperature: +14° to +170° F at 250 PSI4. Electronics operating temperature (Converter): -4° to +140° F5. Size: 48” diameter PCCP pipe. Supplier shall perform necessary field measurements.6. Installation hardware shall include a Stainless Steel 2” full ported valve with stainless-steelnipple.7. Submergence:a. The sensor shall be NEMA 6P or IP68 rated to be permanently submerged up to 6feet.C. Converter:1. Electronic Enclosure: Shall be a NEMA 4X, IP67 rated enclosure.40 71 13.23Insertion-Type Magnetic Flow Meters1 of 3Mobile Area Water and Sewer SystemKimberly Clark Flow Meter StudyProject No. 1201846.007Purchase SpecificationApril 17, 20262. Converter/display: Background illumination with alphanumeric 8-line graphical backlit LCDdisplay with 6-key tough programming to indicate flow rate, totalized values, settings, andfaults.3. Power supply:a. 90/265 VAC4. Operating temperature: -4 to 140° F5. Outputs:a. Two 4-20 mA (0-21 mA)b. Two separate digital programmable outputs:1) Open collector transistor usable for pulse2) Frequency and alarm settings6. Communications:a. AMI Smart Output (Sensus)7. Sensor and signal converter performance:a. Flow range: 0.2 FPS to 32 FPS for accuracies stated below.b. Accuracy:1) AC Power: Plus, or minus 0.5% of actual flowc. Cable Length:1) AC Power: Manufacturer to coordinate required length with ownerd. Manufacturer shall offer optional Quick Connect cabling for remote mountedinstallations.e. Repeatability: ±0.05% or ±0.0008 ft/s, whichever is greaterf. Conductivity: Minimum 5 µs/cmg. Power and Signal Cabling: The power and signal between the converter and sensorare isolated and placed in separate cables.h. Flow Direction Measurement: Forward flow indication and forward net totalization isrequired8. Other:a. Cable Length: 200’2.03 SPARE PARTSA. Spare parts for the equipment shall include the following, unless otherwise noted:1. Extra operation manuals as required2.04 OPERATOR INSTRUCTIONSA. Calibration1. Each flow sensor shall have wet flow calibration of the complete meter flow element andits signal converter. The calibration facilities must be traceable to the National Institute ofStandards and Technology (N.I.S.T). All the calibration information and factory settingsmatching the sensor shall be stored in an integrally mounted memory unit. The memoryunit shall store sensor calibration data and signal converter settings for the lifetime of theproduct. At initial commissioning, the flow meter commences measurement without anyinitial programming. Any customer specified settings are downloaded to the memory unit.Should the signal converter need to be replaced, the new signal converter will upload allprevious settings and resume measurement without any need for reprogramming orrewiring.2. Manufacturer shall provide a calibrated meter set which includes the sensor element, thecabling and the converter.3. An N.I.S.T. certificate of calibration shall accompany each flow element.40 71 13.23Insertion-Type Magnetic Flow Meters2 of 3Mobile Area Water and Sewer SystemKimberly Clark Flow Meter StudyProject No. 1201846.007Purchase SpecificationApril 17, 2026PART 3 – EXECUTION4.01 INSTALLATIONA. Follow manufacturer’s recommendation for the minimum upstream and downstream installationrequirements for the flow element or at a location directed by the owner.B. Wiring between flow element and remote mounted signal converters shall use cable type andprocedures as per the manufacturers’ recommendations.4.02 MANUFACTURER’S ASSISTANCEA. Warranty1. The manufacturer of the electromagnetic flow meter shall provide a two-year warranty thatthe equipment shall be free from defects in design, workmanship, or materials. Extendedwarranties up to five years shall be available for additional cost.2. The manufacturer of the electromagnetic flow meter shall provide a Lifetime Guarantee onthe flow element Ultra Liner fusion bonded epoxy liner.3. In the event a component fails to perform as specified or is proven defective in serviceduring the guarantee period, the manufacturer shall promptly repair or replace thedefective part at no cost to the owner.END OF SECTION 40 71 13.2340 71 13.23Insertion-Type Magnetic Flow Meters3 of 3
- Commodity Codes
-
- NAICS 334513Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
- NAICS 334514Totalizing Fluid Meter and Counting Device Manufacturing
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Solicitation for the Overhaul...
Follow Solicitation for the Overhaul of the Vibration Control System for the UH-60
Federal Agency
Bid Due: 7/13/2026
BCL-G103-MiSeq i100 Plus-Illu...
Sourcing Project Number: SRC0000034437 Solicitation Label: BCL-G103-MiSeq i100 Plus-Illumina-Micro-Sole Source Status: Open for
State Government of Alabama
Bid Due: 7/06/2026