Addendum No. 2: Stormwater Maintenance Equipment Rebid
Project Information
- Bid Title
- Addendum No. 2: Stormwater Maintenance Equipment Rebid
- Issuing Agency
- Borough of Seaside Park
- Location
- New Jersey
- Published Date
- Apr 15, 2026
- Closing Date
- Apr 28, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Description Opening Date Closing Date
Addendum No. 2: Stormwater Maintenance Equipment Rebid
April 15, 2026
:
April 28, 2026
1:00
PM
- Attachment Preview
-
BOROUGH OF SEASIDE PARKOCEAN COUNTY, NEW JERSEYOUR FILE: 1528-U-088NJIB CLEAN WATER APPLICATION STORMWATER MAINTENANCEEQUIPMENT REBIDADDENDUM #2April 15, 2026The following additions to the Contract Documents will be written into any Contract for the“NJIB CLEAN WATER APPLICATION STORMWATER MAINTENANCEEQUIPMENT REBID” project and must be taken into account in rendering a Proposal for thework.The following items shall be revised as follows at this time:1. The Bid Opening Date shall be changed to from April 16, 2026 to April 28th, 2026 at1:00 PM. Said Bids will be received, opened and read aloud in public at theBorough Of Seaside Park, 1701 N OCEAN AVE, SEASIDE PARK 08752 on April28, 2026 At 1:00 P.M.2. Section 11500 “11500 - Towable Emergency Diesel Generator and Enclosure Rev4_9_26” of the technical specifications has been revised. The revised Section 11500“11500 - Towable Emergency Diesel Generator and Enclosure Rev 4_9_26” can befound attached to this addendum.All specifications and bids shall be revised accordingly.Please complete the “Acknowledgement of Receipt of Addenda” (Page P-3), attachedhereto, for receipt of this Addendum letter and include with bid documents submission.The Acknowledgement of receipt of addenda page is a mandatory required document andfailure to submit shall be deemed a fatal defect.Alan B. Dittenhofer, PE, PP, CMENJ PE License #37672SEAL1528U088 Addendum #2_RebidPAGE 1SECTION 11500TOWABLE EMERGENCY DIESEL GENERATOR AND ENCLOSURE REVISED 4/9/26PART 1 - GENERAL1.01 SCOPEA. Provide complete factory assembled portable generator set equipment with digital electronicgenerator set controls, digital governor, and digital voltage regulator.B. Provide factory test, startup by a supplier authorized by the equipment manufacturer and on-sitetesting of the system.C. The generator set manufacturer shall warrant all equipment provided under this section, whetheror not it is manufactured by the generator set manufacturer, so that there is one source forwarranty and product service.D. Technicians specifically trained and certified by the manufacturer to support the product andemployed by the generator set supplier shall service the generator sets.1.02 Codes and StandardsA. The generator set installation and on-site testing shall conform to the requirements of thefollowing codes and standards, as applicable. The generator set shall include necessary featuresto meet the requirements of these standards.1. 40 CFR 89, Nonroad (Mobile Off Highway)2.IEEE446 – Recommended Practice for Emergency and Standby Power Systems for Commercialand Industrial Applications3.NFPA37 –4.NFPA70 – National Electrical Code. Equipment shall be suitable for use in systems incompliance to Article 700, 701, and 702.5.NFPA99 – Essential Electrical Systems for Health Care Facilities6.NFPA110 – Emergency and Standby Power Systems. The generator set shall meet allrequirements for Level 1 systems. Level 1prototype tests required by this standard shall havebeen performed on a complete and functional unit, component level type tests will not substitutefor this requirement.B. The generator set and supplied accessories shall meet the requirements of the following standards:1. NEMA MG1-1998 part 32. Alternator shall comply with the requirements of this standard.2. UL142 – Sub-base Tanks3. UL1236 – Battery Chargers4. UL2200. The generator set shall be listed to UL2200 or submit to an independent third partycertification process to verify compliance as installed..C. The control system for the generator set shall comply with the following requirements.TOWABLE EMERGENCY DIESEL GENERATOR AND ENCLOSURE11500 - 11. CSA C22.2, No. 14 – M91 Industrial Control Equipment.2. EN50082-2, Electromagnetic Compatibility – Generic Immunity Requirements, Part 2: Industrial.3. EN55011, Limits and Methods of Measurement of Radio Interference Characteristics ofIndustrial, Scientific and Medical Equipment.4. FCC Part 15, Subpart B.5. IEC8528 part 4. Control Systems for Generator Sets6. IEC Std 801.2, 801.3, and 801.5 for susceptibility, conducted, and radiated electromagneticemissions.7. UL508. The entire control system of the generator set shall be UL508 listed and labeled.8. UL1236 –Battery Chargers.D. The generator set manufacturer shall be certified to ISO 9001 International Quality Standard andshall have third party certification verifying quality assurance in design/development, production,installation, and service, in accordance with ISO 9001.1.03 Acceptable ManufacturersAll generator manufacturers will be considered however the proposed generator must complywith the specification in its entirety. The equipment must be BABA (Build America, BuyAmerica) compliant. Federal infrastructure investments obligated on or after May 14, 2022, mustcomply with the Build America, Buy America (BABA) Act, which requires the use of domesticiron and steel, manufactured products, and construction materials in covered infrastructureprojects. Products that qualify for a de minimis waiver cumulatively may comprise no more thana total of five percent of the total project cost, otherwise a project specific SRF Waiver must beobtained.PART 2 - MATERIALS2.01 Generator set: Trailer mounted diesel generator with on-board fuel tank:Voltage: 3 – position switch• Three Phase, Switchable: 120/208, 277/480• Single Phase, Switchable: 120/240Frequency Capability:60 HertzA. Ratings1. The generator set shall operate at 1800 rpm and with multi-voltage field selection option.2. The generator set shall be rated, based on site conditions of: Altitude 499ft. ambient temperatures up to 40 degrees C.3. The generator set rating shall be based on emergency/standby service at 150°C Rise.A. PerformanceTOWABLE EMERGENCY DIESEL GENERATOR AND ENCLOSURE11500 - 21. Voltage regulation shall be plus or minus 0.5 percent for any constant load between no load andrated load. Random voltage variation with any steady load from no load to full load shall notexceed plus or minus 0.5 percent.2. Frequency regulation shall be isochronous from steady state no load to steady state rated load.Random frequency variation with any steady load from no load to full load shall not exceed plusor minus 0.5%.3. The diesel engine-generator set shall accept a single step load of 100% nameplate kW and powerfactor, less applicable derating factors, with the engine-generator set at operating temperature.4. The alternator shall produce a clean AC voltage waveform, with not more than 5% total harmonicdistortion at full linear load, when measured from line to neutral, and with not more than 3% inany single harmonic, and no 3rd order harmonics or their multiples. Telephone influence factorshall be less than 50 per Nema MG1-22.43.5. The generator set shall be certified by the engine manufacturer to be suitable for use at the installedlocation and rating, and shall meet all applicable exhaust emission requirements at the time ofcommissioning.B. Construction1. The engine-generator set shall be mounted on a heavy-duty steel base to maintain alignmentbetween components. The base shall incorporate a battery tray with hold-down clamps within therails.2. All switches, lamps, and meters in the control system shall be oil-tight and dust-tight. All activecontrol components shall be installed within a UL/NEMA 3R enclosure. There shall be noexposed points in the control (with the door open) that operate in excess of 50 volts.C. Connections1. The generator set load connections shall be supplied with Camlock Connection.2. Power connections to auxiliary devices shall be made at the devices, with required protectionlocated at a wall-mounted common distribution panel.3. Generator set control interfaces to other system components shall be made on a permanentlylabeled terminal block assembly. Labels describing connection point functions shall be provided.2.02 Engine and Engine EquipmentThe engine shall be electronic direct injection 4-cycle liquid cooled diesel engine. The engineshall be turbo charged and have a turbo after cooler. A. the Diesel Engine must EPA Tier level 4compliant. Minimum displacement shall be based on rating/engine size, 74 HP 2.9L. Engineaccessories and features shall include:TOWABLE EMERGENCY DIESEL GENERATOR AND ENCLOSURE11500 - 3A. An electronic governor system shall provide automatic isochronous frequency regulation. Thegoverning system dynamic capabilities shall be controlled as a function of engine coolanttemperature to provide fast, stable operation at varying engine operating temperature conditions.The control system shall actively control the fuel rate and excitation as appropriate to the state ofthe generator set. Fuel rate shall be regulated as a function of starting, accelerating to startdisconnect speed, accelerating to rated speed. The governing system shall include aprogrammable warm up at idle and cool down at idle function. While operating in idle state, thecontrol system shall disable the alternator excitation system.B. Compliance and certifications: 110% Fluid containment required, USA DOT Compliant system,CSA listed, Transport Canada Compliant, and the Diesel Engine must EPA Tier level 4compliant.C. Electric starter(s) capable of three complete cranking cycles without overheating.D. Positive displacement, mechanical, full pressure, lubrication oil pump.E. Full flow lubrication oil filters with replaceable spin-on canister elements and dipstick oil levelindicator.F. An engine driven, mechanical, positive displacement fuel pump. Fuel filter with replaceablespin-on canister element. Fuel cooler, suitable for operation of the generator set at full rated loadin the ambient temperature specified shall be provided if required for operation due to the designof the engine and the installation.G. Provide a 120 volt block heater accordance with the manufacture’s recommendation to preventhumidity and corrosion damage of the electrical and mechanical components.H. Replaceable dry element air cleaner with restriction indicator.I. Flexible supply and return fuel lines. Unit will draw and return fuel from the sub-based fuel tanklocated below the generator skid frame. Fuel supply and return lines provided and installed byinstalling mechanical contractor must limit the fuel restriction of the return fuel line 5.9Hgmaximum with a maximum fuel flow capable of 14.1gph.J. Engine mounted battery charging alternator, per manufactures requirements.K. Coolant heater1. Engine mounted, thermostatically controlled, coolant heater(s) for each engine. Heatervoltage shall be as shown on the project drawings. The coolant heater shall be UL499listed and labeled.2. The coolant heater shall be installed on the engine with silicone hose connections.Connections into the engine coolant system shall be per manufacturers recommendation.The coolant heater installation shall be specifically designed to provide proper venting ofthe system. The coolant heaters shall provisions to isolate the heater for replacement ofthe heater element without draining the coolant fromthe generatorset. The quick disconnect/automatic sealing couplers shall allow the heaterelement to be replaced without draining the engine cooling system or significant coolantloss.3. The coolant heater shall be provided with a DC thermostat, installed at the enginethermostat housing. An AC power connection box shall be provided for a single ACpower connection to the coolant heater system. : The unit shall include one (1) 12 VDCto 110VAC volt single-phase inverter, 1750 watts, mounted inside enclosure, dualcontinuous duty 10-amp GFI outlets, one (1) fusible link.TOWABLE EMERGENCY DIESEL GENERATOR AND ENCLOSURE11500 - 4
- Commodity Codes
-
- NAICS 811219Other Electronic and Precision Equipment Repair and Maintenance
- NAICS 811310Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Print Shop Machinery - Servic...
Project ID: 06Q-27 Title: Print Shop Machinery - Services, Repair and Maintenance Addenda:
Passaic Public Schools
Bid Due: 7/17/2026
PREVENTIVE MAINTENANCE AND RE...
Project ID: Title: PREVENTIVE MAINTENANCE AND REPAIR SERVICE TO VARIOUS LIFT STATIONS, PUMPS,
Middlesex County
Bid Due: 7/21/2026