Electrical Vehicle (EV) Charging Station
Project Information
- Bid Title
- Electrical Vehicle (EV) Charging Station
- Issuing Agency
- City of Ripon
- Location
- California
- Published Date
- Nov 20, 2025
- Closing Date
- Nov 25, 2025
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Electrical Vehicle (EV) Charging Station
Department: Engineering
Start Date: 11/04/2025
Close Date: 11/25/2025 3:00 PMSEALED BIDS will be received by the City Clerk of the City of Ripon at 259 N. Wilma Ave., Ripon, California until 3:00 pm, Tuesday, November 25, 2025 for the EV Charging Station project.
NO PRE-BID MEETING AND JOB WALK.
Bid Set Project Documents:
Disclaimer Regarding Project Bid Documents & AB 2036 Compliance
Plans: EV Charging Station Plans (PDF)
Specs: EV Charging Station Project Specifications (PDF)
Addendums:
EV Charging Station Project Addendum No. 1 (PDF)
EV Charging Station Project Addendum No. 2 (PDF)This website is a free service provided by the City of Ripon ("City") for review and download of project bid documents. This site is the only sites for prospective bidders to obtain information and digital copies of official City bid documents.
The City does not warrant, represent, or guarantee the accuracy or completeness of any bid documents and/or information retrieved from any third party source. The City is not responsible for any loss or damage including, but not limited to, time, money, or goodwill arising from errors, inaccuracies or omissions in any third party bid documents and/or information.
Be advised that the information contained on this website may change over time and without notice to prospective bidders. It is the responsibility of each prospective bidder to check this website on a DAILY bases through the close of bids for any applicable addenda or updates.
City bid documents are provided electronically and free of charge. Each prospective bidder must download and print all bid documents for review and bid. It is the responsibility of each prospective bidder to verify the completeness of their printed bid documents before submitting a bid and accompanying executed addenda acknowledgement, and other required forms.
- Attachment Preview
-
CITY OF RIPONEV CHARGING STATION PROJECTSITE 2: CITY HALLNSITE 1: CORP YARDELECTRICAL SPECIFICATIONSGENERAL NOTES:1. ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIACODE OF REGULATIONS, INCLUDING THE FOLLOWING:TITLE 24, CCR, PART 2, 2019 CBCTITLE 24, CCR, PART 3, 2019 CECTITLE 24, CCR, PART 4, 2019 CMCTITLE 24, CCR, PART 9, 2019 CFCALL APPLICABLE LOCAL CODES.2. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, ETC.REQUIRED TO CARRY ON AND COMPLETE THE WORK. PERMIT BY OWNER.3. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION ANDPERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPEREXECUTION AND COMPLETION OF ALL "ELECTRICAL WORK" WHETHER SPECIFICALLYMENTIONED OR NOT; ALL AS INDICATED, SPECIFIED HEREIN, AND/OR IMPLIED THEREBY TOCARRY OUT THE APPARENT INTENT THEREOF.4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS'LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BEAR THEIR LABELWHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLYFURNISHED BY THAT AGENCY.5. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZEAND LOCATIONS OF EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE,CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFYTHIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUTAND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES.6. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN UNLESS OTHERWISENOTED OR REQUIRED BY CODE.NAMEPLATES & IDENTIFICATION:INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC.NAMEPLATES SHALL BE SECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPSROUND HEAD CADMIUM PLATED SELF-TAPPING SCREWS, BRASS BOLT, OR WITH A PLASTICRESIN ADHESIVE GLUE, GOODYEAR "PLIEBOND" OR EQUAL.WIRING METHODS:1. ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS, CONCEALED IN WALL ANDCEILING U.O.N.2. MINIMUM CONDUIT SIZE SHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS AREA. GALVANIZED RIGID STEEL.B. GALVANIZED STEEL EMT.C. LIQUID TIGHT STEEL FLEX - FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT.D. FLEXIBLE STEEL CONDUIT - FOR INDOOR FINAL CONNECTIONS TOMECHANICAL EQUIPMENT (NOT TO EXCEED 36").E. PVC CONDUIT SCHEDULE 40, UNDERGROUND.3. NMC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING.4. MC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING.SUPPORTS:1. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALLELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT.2. ATTACH ALL ELECTRICAL JUNCTION BOXES TO WOOD WITH WOOD OR LAG SCREWS, TOMETAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORSAND MACHINE SCREWS OR BOLTS.GROUNDING:1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES ANDSPECIFICALLY INCLUDING SWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC.PANELBOARDS:UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE,WITH THE NUMBER AND SIZE OF BREAKERS INDICATED ON THE PANEL SCHEDULE. SINGLEPOLE, TWO POLE AND THREE POLE BREAKERS SHALL BE BOLT-ON TYPE. THE PANELDOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKE AND HAVETYPEWRITTEN DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICED BYEACH BREAKER. ALL BUSSING SHALL BE COPPER..TESTING:1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS ANDIMPROPER GROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY ANDGROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHETHER SUCHTESTS INDICATE FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED,REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE.ELECTRICAL LEGENDELECTRICAL POWERALL LINE VOLTAGE WIRING IN CONDUIT, SEE GENERAL NOTESTICKS = # OF #12 WIRE, SHORT = HOT, LONG = NEUTRAL, DOT = GROUND,UNLESS NOTED OTHERWISE120V OUTLET, +18" TO BOTTOM OF BOX•S = SIGN•F = FLOOR•GFI = GROUND FAULT INTERUPTERCOUNTER OUTLET. +44" TO TOP OF BOX.QUADRUPLEX OUTLETHALF SWITCHED OUTLETSJJUNCTION BOX WITH MOTOR TOGGLE DISCONNECTJJUCTION BOXMOTOR / DISCONNECTPANELBOARDTRANSFORMER / SWITCHBOARD AS NOTEDN##N##AE-2(e) (E)DRAFTING NOTATIONSKEY NOTE, SEE SCHEDULEEQUIPMENT TAG, SEE SCHEDULEREFERENCE TO A DETAIL VIEW "A" ON SHEET E-2NEW ELECTRICAL CONDUIT AND WIREEXISTING DEVICE, TO REMAIN IN OPERATIONELECTRICAL ABBREVIATIONS:AL = ALUMINUMA = AMPERAGEAIC = AMPS INTERRUPTING CAPACITYAFF = ABOVE FINISHED FLOORAFG = ABOVE FINISHED GRADECKT = CIRCUITCO = CONDUIT ONLYCU = COPPEREC = ELECTRICAL CONTRACTORGC = GENERAL CONTRACTORGFI = GROUND FAULT INTERRUPTERGND = GROUNDKW = KILOWATTKVA = KILO-VOLT-AMPERELC = LIGHTING CONTACTORNO = NUMBERNL = NIGHT LIGHTPB = PULLBOXSP = SPACEUG = UNDERGROUNDUON = UNLESS OTHERWISE NOTEDV = VOLTWP = WEATHERPROOFpath://john/17/4REVISIONSBYC:\Users\RichardSmith\Box\2022\ripon ev\RIPON EV ELECTRICAL.rvtSTAMPED HPARRODFESCS. ISONMALNo. E14303Exp. 6-30-25TELECE OFTCRAILCIFAOL RNDRAWNRCSCHECKEDRCSDATE2/3/2025 1:41:57 PMSCALEAs indicatedJOB201N7O..xxxSHEETE136"SD12"SSNPWIVIV36"SD36"12"SSIVIVIV(e)PANEL EVINSTALL (2)2"C ABOVECEILING. VERIFY ROUTEIN FIELD.JSN.03(E)CONDUIT INSTALLED UNDER ORIGINALDEVELOPMENT. VERIFY IN FIELD.SN.01SN.06J EV-1,3J EV-9,11J EV-13,15INSTALL NEW CONCRETECHRISTY #N36 PULLBOXOVER EXISTING CONDUIT STUBS,EXTEND PVC CONDUITS UNDERGROUNDTO NEW CHARGERS(e)DIST PANEL D1(e)TX1(e)MAIN SERVICE1 CORP YARD ELECTRICAL SITE PLANSCALE: 1" = 20'-0"path://john/17/4IVIVIV IVIVIVIVIVIVIVIV(E)CONDUIT INSTALLED UNDER ORIGINALDEVELOPMENT. VERIFY IN FIELD.JEV-17,19,21,23JEV-25,27,29,31INSTALL CHRISTYN36 PULLBOX OVERCONDUIT STUBS,EXTEND CONDUTIS TO NEWCHARGER.SN.01SN.02SHEET NOTESKey ValueSN.01SN.02SN.03SN.06Keynote TextPROVIDE CHARGEPOINT CT4000 LEVEL 2 CHARGER,208V, 1PH, 6200W. SEE MOUNTING DETAILS.EXTEND 1.25"C-4#4+1#8 GND FROM PANEL THROUGHEXISTING CONDUIT,TO NEW PULLBOX AND THEN TOEV CHARGER. REUSE EXISTING CONDUIT WHEREPOSSIBLE.EXTEND (2)2" CONDUIT STUBS TO (e)PANEL EVEXTEND 1.25"C-2#4+1#8 GND FROM PANEL THROUGHEXISTING CONDUIT,TO NEW PULLBOX AND THEN TOEV CHARGER. REUSE EXISTING CONDUIT WHEREPOSSIBLE.(e)MAIN SERVICE(e)800A - 480V BUSM(e)3503(e)GROUND(e)(e)225KVATRANSFORMERNOTE:NO CHANGES, SHOWN FORREFERENCE ONLY(e) DISTRIBUTION PANEL “D1”(e)800A - 120208V, 3PH, 4W BUS(e)8003(e)2003ARC FLASH LABELLING REQUIREMENT:PROVIDE THE FOLLOWING LABEL AS A MINIMUMFOR COMPLIANCE WITH NFPA AND NEC ONTHIS PROJECT:DANGERARC FLASH AND SHOCK HAZARDFOLLOW ALL REQUIREMENTS IN NFPA 70EFOR SAFE WORK PRACTICES AND FORPERSONAL PROTECTIVE EQUIPMENT(e)PANEL"HV"2 CORP YARD ONE LINE DIAGRAMSCALE: NTSREVISIONSBY(e)PANEL EVLocation:Supply From:Mounting: RecessedEnclosure: Type 1Notes:Volts: 120/208 WyePhases: 3Wires: 4A.I.C. Rating: 22,000Mains Type: MLOMains Rating: 225 AMCB Rating: 225 ACKTCircuit DescriptionEV-1 EV CHARGEREV-3 --EV-5EV-7EV-9 EV CHARGEREV-11 --EV-13 EV CHARGEREV-15 --EV-17 EV CHARGEREV-19 --EV-21 EV CHARGEREV-23 --EV-25 EV CHARGEREV-27 --EV-29 EV CHARGEREV-31 --EV-33EV-35EV-37EV-39EV-41Legend:Trip PolesA40 A 2 3200 VA----40 A--40 A--40 A--40 A--40 A--40 A--2--2 3200 VA--2-- 3200 VA2--2 3200 VA--2-- 3200 VAB3200 VA3200 VA3200 VA3200 VA3200 VAC3200 VA3200 VA3200 VA3200 VAPoles TripTotal Load:Total Amps:16000 VA137 A16000 VA137 A12800 VA107 AREUSE 4 BREAKERS, ADD 4 BREAKERSCircuit DescriptionCKTEV-2EV-4EV-6EV-8EV-10EV-12EV-14EV-16EV-18EV-20EV-22EV-24EV-26EV-28EV-30EV-32EV-34EV-36EV-38EV-40EV-42C:\Users\RichardSmith\Box\2022\ripon ev\RIPON EV ELECTRICAL.rvtSTAMPED HPARRODFESCS. ISONMALNo. E14303Exp. 6-30-25TELECE OFTCRAILCIFAOL RNDRAWNRCSCHECKEDRCSDATE2/3/2025 1:41:57 PMSCALEAs indicatedJOB201N7O..xxxSHEETE2Key ValueSN.01SN.02SN.04SHEET NOTESKeynote TextPROVIDE CHARGEPOINT CT4000 LEVEL 2 CHARGER, 208V, 1PH, 6200W. SEEMOUNTING DETAILS.EXTEND 1.25"C-4#4+1#8 GND FROM PANEL THROUGH EXISTING CONDUIT,TO NEWPULLBOX AND THEN TO EV CHARGER. REUSE EXISTING CONDUIT WHEREPOSSIBLE.SAWCUT AND INSTALL CONDUIT 24" BELOW GRADE, PATCH TO MATCH EXISTINGREVISIONSBYpath://john/17/41 CITY HALL ELECTRICAL SITE PLANSCALE: 1" = 20'-0"SN.04EV2-9,11,EV2-13,15JSN.01MAIN ELECTRICAL SERVICEADD BREAKER PER ONE LINE DIAGRAMPOST MOUNTED PANEL EVEV2-1,3,EV2-5,7JSN.02INSTALL THIS NEWELECTRICALSUBPANEL ON POSTSTO SERVE POWER TONEW EV CHARGERS28" WIDE(N)ELECTRICALSUB-PANELEV3/8" DIA BOLT TO P1000 STRUTBEHIND METER / PANELTYP OF 4.P2860-10 CAPTYPICAL FOR 2P1000 W/ 3/8" DIA MINBOLT TO P1000 STANCHIONPOST.FINISHED GRADELOCKPVCCONDUITPER PLANP1001 POSTUNISTRUT P2073ASQ BASE PLATEW/ (4)5/8"DIA HILTI KWIK BOLTTZ2SS W/3-1/4" EFF. MIN EMBED. TORQUETO 60 FT-LBS.FINISHED GRADE6" THICK CONCRETE PAD W/#4 REBAR AT 12" O.C. BOTHWAYS AT MID DEPTH OF PAD6" MIN. TYP.(2)1/2"DIA SPRINGNUT/BOLTS. TYP.3 POST MOUNTED PANELSCALE: NTS(e)MAIN SERVICE(e)120/208V BUSADD 2003(e)GROUND2"C-4#3/0+1#4 GNDPANEL"EV2"ARC FLASH LABELLING REQUIREMENT:PROVIDE THE FOLLOWING LABEL AS A MINIMUMFOR COMPLIANCE WITH NFPA AND NEC ONTHIS PROJECT:DANGERARC FLASH AND SHOCK HAZARDFOLLOW ALL REQUIREMENTS IN NFPA 70EFOR SAFE WORK PRACTICES AND FORPERSONAL PROTECTIVE EQUIPMENT2 CITY HALL ONE LINESCALE: NTSPANEL EV2Location:Supply From:Mounting: POST MOUNTEDEnclosure: NEMA 3RNotes:Volts: 120/208 WyePhases: 3Wires: 4A.I.C. Rating: 22,000Mains Type: MLOMains Rating: 200 AMCB Rating: 200 ACKTCircuit DescriptionEV2-1 EV CHARGEREV2-3 --EV2-5 EV CHARGEREV2-7 --EV2-9 EV CHARGEREV2-11 --EV2-13 EV CHARGEREV2-15 --EV2-17EV2-19EV2-21EV2-23EV2-25EV2-27EV2-29Legend:Trip40 A--40 A--40 A--40 A--PolesA2 3200 VA--2-- 3200 VA2--2 3200 VA--B3200 VA3200 VA3200 VAC3200 VA3200 VAPoles TripTotal Load:Total Amps:9600 VA84 A9600 VA84 A6400 VA53 ACircuit DescriptionCKTEV2-2EV2-4EV2-6EV2-8EV2-10EV2-12EV2-14EV2-16EV2-18EV2-20EV2-22EV2-24EV2-26EV2-28EV2-30C:\Users\RichardSmith\Box\2022\ripon ev\RIPON EV ELECTRICAL.rvtSTAMPED HPARRODFESCS. ISONMALNo. E14303Exp. 6-30-25TELECE OFTCRAILCIFAOL RNDRAWNRCSCHECKEDRCSDATE2/3/2025 1:41:58 PMSCALEAs indicatedJOB201N7O..xxxSHEETE3path://john/17/4REVISIONSBY(PVC CONDUIT UNDERGROUND)C:\Users\RichardSmith\Box\2022\ripon ev\RIPON EV ELECTRICAL.rvtSTAMPED HPARRODFESCS. ISONMALNo. E14303Exp. 6-30-25TELECE OFTCRAILCIFAOL RNDRAWNRCSCHECKEDRCSDATE2/3/2025 1:42:01 PMSCALEJOB201N7O..xxxSHEETE4
- Commodity Codes
-
- NAICS 238210Electrical Contractors and Other Wiring Installation Contractors
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Southeast Water Pollution Con...
Bid Details RFP for DB-140 Southeast Water Pollution Control Plant - Secondary Clarifiers
San Francisco Public Utilities Commission
Bid Due: 8/05/2026
Project: TEC Modernization Addition Ref. #: 2026-1683 Type: ITB Status: Open Open Date:
Alameda-Contra Costa Transit District
Bid Due: 7/21/2026