Fire Suppression Backflow preventer
Project Information
- Bid Title
- Fire Suppression Backflow preventer
- Issuing Agency
- DEPT OF DEFENSE
- Location
- Kansas
- Published Date
- Jul 9, 2026
- Closing Date
- Jul 20, 2026
- Government Level
- Federal
- Status
- Closed
- Ref. #
- PANNGB26P0000038507
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Set Aside
- Total Small Business Set-Aside (FAR 19.5)
- Project Description
-
FollowFire Suppression Backflow preventerActiveContract OpportunityNotice IDPANNGB26P0000038507Related NoticeDepartment/Ind. AgencyDEPT OF DEFENSESub-tierDEPT OF THE ARMYMajor CommandNATIONAL GUARD BUREAUSub CommandJFHQ USPFO KSSub Command 2USPFO KS PROCUREMENTOfficeW7M9 USPFO ACTIVITY KSANG 184General InformationLooking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Jul 09, 2026 02:01 pm CDT
- Original Response Date: Jul 20, 2026 09:00 am CDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Aug 04, 2026
-
Initiative:
- None
Classification- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: J012 - MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
McConnell AFB , KS 67221USA
DescriptionThis is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.
Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following:
-
Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression
- Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.
- Install a new 6-inch diameter Fire Suppression Backflow Prevention System.
- Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
-
Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
-
Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve
- Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.
- Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.
- Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
-
Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
-
Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup
- Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System.
- Install a new 1-inch diameter Boiler Makeup Backflow Prevention System.
- Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
-
Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
-
Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression
- Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System.
- Install a new 4-inch diameter Fire Suppression Backflow Prevention System.
- Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
-
Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
-
Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water
- Remove the existing 2.5-inch diameter domestic water Backflow Prevention System.
- Install a new 2.5-inch diameter domestic water Backflow Prevention System.
- Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
-
Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.
Attachments:
1. Statement of Work
2. Sources Sought Response Form
Attachments/LinksContact InformationHistoryContracting Office Address- KO DODAAC FOR KSANG DO NOT DELETE 52955 JAYHAWK DR SUITE 153
- MCCONNELL AFB , KS 67221-9000
- USA
Primary Point of Contact- Kevin Smith
- 184wg.msg.contracting@us.af.mil
- Phone Number 3167597591
Secondary Point of Contact- Joshua Kingori
- 184WG.MSG.CONTRACTING@us.af.mil
- Phone Number 3167597590
- Jul 09, 2026 02:01 pm CDTSources Sought (Original)
- Commodity Codes
-
- FSC JMaintenance, Repair, and Rebuilding of Equipment
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
On Call Guardrail Repair Serv...
Event Name On Call Guardrail Repair Services Business Unit Department of Transportation Event
State Government of Kansas
Bid Due: 8/19/2026
70th and Oakview Pipe Repair ...
Public Notices 70th and Oakview Pipe Repair - Notice to Bid 70th and
City of Shawnee
Bid Due: 8/13/2026