Whitehaven Clinic Construction - Questions and Answers No 2
Project Information
- Bid Title
- Whitehaven Clinic Construction - Questions and Answers No 2
- Issuing Agency
- Shelby County
- Location
- Tennessee
- Published Date
- Feb 23, 2026
- Closing Date
- Mar 16, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- SB-I000928
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid Title:SB-I000928 Questions and Answers No 2Category:Health DepartmentStatus:OpenPublish Date:Monday, February 23, 2026 - 11:45amClose Date:03/16/2026 - 2:00pm[X]Contact Person:Carla Hayes
Please submit following details in order to view the document
Name/Business Name *Email Address *Phone Number *Bid TitleRedirect URLRelated Documents: - Attachment Preview
-
Shelby CountyTennesseeLee Harris, MayorQUESTIONS & ANSWERS No. 2Issued: December xx, 2025Whitehaven Clinic Construction(Health Services Department)TO ALL PROSPECTIVE BIDDERS:The following question(s) were submitted by potential bidders with answers listed below in red:Q-7. Looking through the documents, I don't see a required number of days forconstruction. Can you provide the number of days for substantial and final completion?A-7. 548 calendar daysQ-8. Drawing A-701 (ROOM FINISH SCHEDULE – FIRST FLOOR) does not list finishes for55 of the 66 rooms on the schedule. The vast majority are listed as “varies” while some aresimply left blank. The floor finish is shown on the drawing, but the base, wall finish and ceilingsneed to be defined. Please clarify what is required.A-8. See revised finish sheetsQ-9. The Door Schedules (A-631, A-632, A-633) do not appear to be complete. The column forthe Hardware Sets is not filled in, among other things. The project manual in section 08 71 00(DOORS AND DOOR HARDWARE) do contain a listing for hardware for the doors on theFirst Floor, but in several places it does not match the Door Schedule. The specifications listshardware for doors 148A, 159A, 165A, 167A, 126B, 152B, 157A, 133A, 138A, 139A, 145A,158A, 160A, but these doors are not listed on the Door Schedule. The specifications do not listany Finish Hardware for the doors on the Second and Third Floors. Please let us know what weshould price.A-9. See revised door schedule sheets and updated spec sectionQ-10. Are there any ALLOWANCES associated with this project? The project manual does notcontain as Allowance section. There really needs to be an Allowance for the Utility Connection1Fees as you know that MLGW will not provide pricing for a project until a contract is actuallysigned.A-10. Bidding GC’s are to include $200,000 as an allowance.Q-11. Stair Tread with contrasting with abrasive grit strip and separate Risers to match colors islisted in the specifications but not listed on finish plan. Do we price the treads on this project?A-11. Stair treads, risers, and all landings are to be Johnsonite Rubber Stairwellsystem:Color: 84 Blue JeansTread and Landing Pattern: DiamondTread Insert: 40 Black InsertQ-12. What carpet that’s Noted-CRPT-01? Is it J&J Incognito- 1841 intelligence 24”x24”?A-12. Walk off carpet - Tuff Stuff II Step in Style II GT312 955 Cobalt installed ¼ turn.Q-13. Room Schedule Doesn’t match the Finish Plans- We will price Project per notes on Finishplan. Reference room finish schedule on A-701.A-13. See updated finish sheetsQ-14. Do we price Flooring Protection for all Flooring Material?A-14. It is the success general contractor’s responsibility to project all installedmaterials until the project is turned over to owner.Q-15. Do we price 5% Added Stock for all Material?A-15. YesQ-16. I am preparing the takeoff for Fire Protection section (104400) for the Shelby CountyClinic – Whitehaven, I see that the specs call for multiple types of fire extinguishers and cabinetbut the plans only mark the FE and FEC but not the specific type. Is there more information thatcan be provided so I can ensure that our quantities and scope of work can be aligned?A-16. All fire extinguishers are to be red 10 lb. Class A type. Brands/ manufacturerscarrying UL certification are acceptable. Some examples are Amerex, Kiddle,Badger, Buckey, and Ansul. Fire extinguisher cabinets are to be ADA compliantsemi-recessed. Basis of design: Larsen 240957 Aluminum full glass type or equal.Q-17. Please send us an updated planholders/bidders list.A-17. Shelby County Government does not maintain or release a planholders/bidderslist; however, the sign-in sheet for the mandatory pre-bid meeting will be postedon the county website.2Q-18. Please also let us know if there are any changes to the bid dateA-18. Shelby County Government bid postings are located on the County’s website atwww.shelbycountytn.gov. At the top of the home page, click on the dropdownbox under “Business”, Click on “Purchasing” and “Bids” to locate the name ofthe above-described Sealed Bid.Q-19. Please provide a construction cost estimate or budget range if available.A-19. Not available.Q-20. Is there a required start date for construction?A-20. No, construction will not begin unit the contract is awarded and Notice toProceed is issued.Q-21. Is the number of days for completion an evaluation factor for the award selection?A-21. See Q-7 above.Q-22. Will there be an allowance for the furniture?A-22. No, contractor is to be provide pricing for all furnishings based upon the basis ofdesign or equal.Q-23. If the FF&E is contractor-furnished, contractor-installed, does that include the medicalequipment, i.e. microscopes?A-23. Medical equipment is OFOI. All other items are CFCIQ-24. Are there any additional Alternative work elements?A-24. Other than the parking area identified as Alt No. 1, no.Q-25. May will make additional site visit and if so with whom do we coordinate?A-25. The site is a parking lot and is open 24/7/365. One is more than welcome to govisit when convenient. If need, contact Jeff Goodman at 814 Jefferson: 901-426-0125.Q-26. At the prebid we were told to furnish everything on the A 9 sheets. There are only specsfor three chairs and three tables. Are we to price the other items on this sheet? Please provide acomplete spec for all items of furniture we should price. On A903 the schedule of the furnitureneeds to be corrected. It mentions D-311 twelve times but there is not a D-311 there is a O-311office. The other offices are not on the schedule.A-26. See updated A-900 series sheets3Q-27. For the windows receiving the security film, it states "3M Scotchshield Ultra Safety &Security Window Film". That is very vague on which thickness, and what they are trying toachieve. The specs do not give us much to go off of at all.A-27. The 3M Safety & Security Window Film has been eliminated from the project.Q-28. The A8 sheets need to be revised to show model number of what furniture and equipmentwe are furnishing.A-28. See updated A-800 series sheets.Q-29. The time of the project should be identified so that all the bidders are bidding on the sametime frame project. If everyone is bidding on different time frames, how will these time framesbe used in determining the awarded contractor?A-29. See response to question No. 7 above.Q-30. On Security Film schedule.• 1st Floor - Security Checking - Elevation not shown Should it be the B? FP Nurse doesnot show a “F” glass.• 2nd Floor - Check in B2 and B3 not on Plans. Does Conference Door/S/L get film. BPPeer Office shows no elevation• 3rd Floor - Accessory #4 no glass specified. Offices 306-310 - No film specified.A-30. See response to question No. 27 above.Q-31. As discussed at the pre-bid meeting today, the Furniture indicated on the “900” drawingsis to be CFCI. The drawings contain FURNITURE DESCRIPTIONS for items CH-1, CH-6,CH-9, TB-2, TB-5 and TB-6. We need product information for the following items: CH-2, CH-3, CH-4, CH-5, CH-7, CH-8, CH-10, CH-12, CH-13, CH-14, CH-15, CH-19, CH-20 TB-1, TB-3, TB-4, TB-10DSK-1, DSK-2, DSK-3A-31. Please see updated A-900 series sheets.Q-32. There appears to be some type of louvered sunshades continuous above the curtain wall onthe West elevation of the building. Can we get a detail of the constructions as we have not beenable to find one that depicts the construction?A-32. The basis of design for the sunshades is Kawneer to match the basis of designcurtain wall system. The basis of design is Versoleil Sunshade Outrigger System36” deep color red. The details are by the curtain wall manufacturer and are tobe submitted via engineered shop drawings.Q-33. As discussed at the Pre-Bid Meeting, the Equipment indicated on the “800” drawings(Equipment Drawings) is to be Owner Furnished and Owner Installed. Please confirm this iscorrect.4A-33. See updated A-800 series sheets.Q-34. Please provide more specific spec section for the metal wall panels. The spec section listedis too generic and lists no product or manufacturer or a design for the wall panels. From thedrawings it seems like it will be an ACM system, but it could be using full sheets of aluminumplate.A-34. See updated spec section for Metal Wall PanelsQ-35. The ROOM FINISH SCHEDULE – THIRD FLOOR (A-703), has a blank for the FloorFinish at the Terrace (B-305). The drawing on this page indicates that the finish is RP-01, butthat is not listed or defined in the FINISH NOTE AND ABBREVIATIONS. Please clarify.A-35. See updated A-700 series sheets.Q-36. The drawings indicate that the building gets a TPO Roof system, but the specifications callfor a MODIFIED BITUMINOUS MEMBRANE ROOF that is fully ballasted. Please clarifywhat type of roof is required.A-36. See updated spec section.Q-37. The project manual contains a section ROOF TOP EQUIPMENT SCREENS (10 02 40),but the extent of the screens are not indicated on the Roof Plan or the buildingelevations. Possibly this section is left over after the requirement for the screens was removedfrom the plans, we don’t know. If these are required, please indicate the extent of the screensrequired. Also, if the supports need to coordinated with the structural at the roof, please providea detail of what will be required.A-37. There will not be equipment screens.Q-38. Stair Tread with contrasting with abrasive grit strip and separate Risers to match colors islisted in the specifications but not listed on finish plan. Do we price the treads on this project?A-38. See updated A-700 series sheets.Q-39. What carpet that’s Noted-CRPT-01? Is it J&J Incognito- 1841 intelligence 24”x24”?A-39. See updated A-700 series sheets.Q-40. LVT-1 Shaw Contract Solitude 0648V 6”x 48” Color TBD.A-40. See updated A-700 series sheets.Q-41. LVT-2 Is Noted by Shaw Contract: Do we use Solitude 0648V 6”x 48” Color TBD- If notwhat style do you want.A-41. See updated A-700 series sheets.5
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Cherokee National Forest Proj...
Follow Cherokee National Forest Project TN ERFO FS CHRKE804 2020-2(2) Active Contract Opportunity
TRANSPORTATION, DEPARTMENT OF
Bid Due: 7/28/2026
Wolf Creek Turbine Generator ...
Follow Wolf Creek Turbine Generator Rehab Active Contract Opportunity Notice ID W912P527T1BX9 Related
DEPT OF DEFENSE
Bid Due: 7/09/2026