J066--Des Moines VAHCS Surgical Instrument Maintenance Sources Sought

Project Information

Bid Title
J066--Des Moines VAHCS Surgical Instrument Maintenance Sources Sought
Issuing Agency
VETERANS AFFAIRS, DEPARTMENT OF
Location
Iowa
Published Date
Jun 11, 2026
Closing Date
Jun 22, 2026
Government Level
Federal
Status
Closed
Ref. #
36C26326Q0758
Original Source
Join to Access Full Details
Project Description
Follow
J066--Des Moines VAHCS Surgical Instrument Maintenance Sources Sought
Active
Contract Opportunity
Notice ID
36C26326Q0758
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 23 (36C263)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Jun 10, 2026 09:46 am CDT
  • Original Response Date: Jun 22, 2026 12:00 pm CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Aug 21, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: J066 - MAINT/REPAIR/REBUILD OF EQUIPMENT- INSTRUMENTS AND LABORATORY EQUIPMENT
  • NAICS Code:
    • 811210 - Electronic and Precision Equipment Repair and Maintenance
  • Place of Performance:
    Des Moines VAHCS Des Moines , IA 50310
    USA
Description
The Des Moines VA Healthcare System requires surgical instrument maintenance and repair services in accordance with the draft Statement of Work (SOW) below.
This is a sources sought/proof of capability solicitation looking for vendors to perform the services per the SOW for market research purposes. No awards of a contract will be made from this announcement.
If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your contact and organization information with a descriptive proof of capability to: Jeffrey.Brown8@va.gov on or before June 19th, 2026. Only emailed responses will be considered.
Additionally, please provide answers as appropriate to the following questions in the table below with your response to this sources sought. Failure to respond to the following questions may affect the acquisition strategy.
Question #
Questions
Vendor Responses
1.
Identify your organization's socio-economic category.
Â
2.
State whether any of the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.).
Â
3.
State if subcontracting is contemplated for this requirement, what percentage of the work will be subcontracted and for what tasks.
Â
Â
*If applicable, VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses or Service Disabled Veteran Owned Small-Businesses.*
*If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses.*
Draft Statement of Work
Central Iowa Veterans Health Administration Health Care System
Surgical Instrument Maintenance and Repair

The Central Iowa Administration Health Care System (CIHCS) requires surgical instrument Preventative Maintenance (PM) and repair services for their Surgical Processing Suite (SPS). The Contractor shall provide an online digital inventory system, or digital tracker, to track instrument repair status and requests that is accessible by the CIHCS.

Preventative Maintenance and Repair
Instrument(s) for this requirement mean: individual general surgical instrument identified during assembly inspection or front line use as not functional and requires evaluation and repair.
Instrument Set(s) for this requirement mean: a uniquely named instrument tray used to contain a series of instruments defined by an instrument count sheet. Sets are between 1 and up to 612 individual instruments used during invasive procedures.
The instrument set is assembled and held inside of a container system where most instruments will stay inside the set over repeated use.
An instrument set may include multiple levels of instruments inside one instrument set.
All instruments sent out within the instrument set must return with the instrument set.
Critical Instrument set : Instrument sets listed below in Appendix A. Critical sets cannot be removed from circulation for more than two to three days at a time without approval of the SPS Chief or designee.
Routine Instrument Set : All non-critical instruments sets, identified in Appendix B.
Preventative maintenance of surgical instruments shall be done by the inspection of entire trays.
Repairs and preventative maintenance shall align with the original manufacturer s design and product specifications.
Equipment subject to repairs and preventative maintenance shall be returned to a state near or at its original OEM specifications in terms of functionality and appearance.
Any modification or repair performed during repair that deviates from the OEM functional or physical specifications for the instrument will render the instrument damaged beyond repair and will need to be replaced at the expense of the repairer per FAR 52.212-4(b).
The Contractor shall ensure repairs and service functions are performed in conformance, the Center for Disease Control (CDC) regulations, Healthcare Sterile Processing Association (HSPA), Association of Peri-Operative Registered Nurses (AORN) Standards, Associate for Professionals in Infection Control and Epidemiology (APIC), the American National Standards Institute (ANSI) and Association for the Advancement of Medical Instrumentation (AAMI).
Instruments submitted for repair and preventative maintenance shall be:
sharpened,
adjusted,
aligned,
straightened,
calibrated,
cleared of rust or debris,
oiled
removal of stains, sharp edges and/or scratches
cannulated/lumened items shall have interior lumen flushed and visually inspected.
all instruments able to be disassembled, shall be disassembled and undergo a detailed inspection.Â
The following miscellaneous repairs shall also be required as applicable: Gasket Replacement Baffle, Inner, Outer Latch Assembly, Single Action Latch Assembly, Upper Latch Plate Replacement, Lower Latch Replacement, Single Action Latch Replacement, Single Action Latch Sheer Block Replacement, Single Action Latch (w/o handle) Replacement, Double Action Latch (w/o handle), Retention Plate Repla cement, Retention Plate Repair, Handle, Replacement, E-Clip Replacement, Hex Nut Replacement, Stud Nut Replacement, Instrument Holding Pin Replacement, Nut Plate Replacement, Screw Replacement for End Plates, Fastener Replacement, Tag Replacement, General Repair, Bent Container, Burr Removal, Dent Removal, Basket Handle Replacement, Basket Handle Bracket, and Basket Handle Leg Bracket.
Returned Instruments shall:
have a mirror finished appearance,
have legible QR Code, manufacturer name, and instrument catalog number
The Contractor shall provide maintenance and repair for rigid instrument containers to ensure that all lid gasket vent devices are fully functional, in accordance with manufacturer specifications.
Items deemed unrepairable need to be returned to facility with clear identification as such.
Any non-OEM parts used to repair an instrument must have product part numbers provided and must have a Food and Drug Administration (FDA) approved Instructions for Use (IFU) that outlines all steps for reprocessing.
The repairer must be able to provide onsite, twice weekly repairs for:
Unscheduled repair needs
same day PM services for critical sets
Site visits should follow a set schedule and be arranged so there is a minimum of 2 weeks between service site visits.
During repair and PM, all instruments are to be evaluated for a 2D QR scan code. When a device does not have a 2D laser code, the repairer will place a laser marked QR code on the instrument, as part of the PM service contract or will flag the instrument.
Devices with new QR codes shall be returned as part of the set it arrived in.
Notification of code placement needs to be communicated to facility via the digital tracker for entry into Censitrac, information to be documented on the digital tracker are:
Device product number,
Device description
Device serial number (if applicable)
QR code numeric assignment.
The Contractor shall place a QR code on the instrument using a laser etching system if no etch is present.
Delicate sharp, pointed instruments delivered in puncture proof containers shall returned be returned in puncture proof containers.
Routine individual instruments that need to have part replacements or more complex repairs, can be relocated to facility repair shop with updates of location change provided via the digital tracker.
Any instruments that fail the quality check upon return to CIHCS shall be resubmitted to the Contractor for repair at the Contractor s expense per Federal Acquisition Regulations (FAR) 52.212-4(a).
All single instruments and surgical trays picked up and delivered back to the hospital should be updated by the Contractor on the digital tracker and following information should be included for each:
Instrument
Name of instrument,
Manufacture catalog number,
Serial number (when applicable),
Quantity of items for accountability,
QR code number assigned to the item.
Instrument set:
Instrument set name,
Tray actual number,
# of instruments included.

Prohibited Repairs
Any instrument found having an unreadable or non-existent Manufacturer s name AND product number visible on the instrument are NOT considered valid reusable instruments.
These instruments shall be marked as damaged beyond repair and returned to SPS.
Any repairs performed on these instruments will not result in compensation.
The Repairer is prohibited from knowingly altering or modifying an original instrument in ANY WAY from the original manufacturers intended design.
Any instrument rendered damaged beyond repair due to performance of the repair or preventative maintenance will be replaced at the Contractor s expense. This can include but not limited to:
Sandblasting shiny instruments to make them dull.
Removing the manufacturer s name or product number found on the instrument.
Altering the product dimensions, angles, length, or adding/removing materials.
Creating a custom instrument.

Refusal to Repair
The contractor shall not classify any instrument(s) as irreparable without providing, concurrently with the return of the instrument(s) to CIHCS:
Written justification citing the specific conditions preventing repair.
Photographic documentation.
Evidence of repair attempt.
Approval of the instrument(s) by a CIHCS representative.

Repairer Response window:
Urgent instrument repair service: Unscheduled repair of critical individual instrument or instrument set which the following applies:
The damage is identified on a day where no onsite visit is anticipated.
The damaged item is a critical instrument for the instrument set.
No alternative substitution available in house to meet the need while waiting for repair.
Patient care delays or cancellations.
The Contractor has 48 hours to complete urgent instrument repairs. Forty-eight hours starts at the time of notification by CIHCS to the Contractor.
Instruments or sets necessitating emergency repairs may be shipped to Contractor facilities if necessary.

Place of Performance
The mobile repair lab will provide onsite repairs at the VA Central Iowa Health Care System, 3600 30th Street, Des Moines, Iowa 50310.
Instruments are to be picked up from the SPS Preparation Area and OR.
Instruments are to be returned to the SPS Decontamination Area.

Off-site repairs: For Contractor's designated facility the address and certification (ISO 13485:2016 certification or VA determined equivalent) provided to COR prior to performance and upon any change.

Scheduled PM for Critical Instrument Sets:
See Appendix A for the list of critical instruments.
Preventative maintenance of critical instrument sets shall be scheduled, and work completed with the same day turnaround. Any exception to the same day turnaround time may only from the COR or another CIH representative.
In the event this is not attainable this is to be communicated directly and immediately with SPS Designee to include what complications are creating a barrier and an ETA of expected downtime.
Off-site repair is allowable for critical instrument sets assuming the repairs are completed within the required timelines for critical instrument sets.

Scheduled PM for Routine Instruments Sets:
See Appendix B for the list of routine instrument sets.
The Contractor shall have seven (7) calendar days to complete routine preventative maintenance on surgical instrument trays with day of pick up considered as day one (1).
If a set will be removed from circulation for longer than seven (7) days, this needs to be directly communicated with the SPS designee and an explanation as to why.
Off-site repair is allowable for routine instrument sets.

Mobile Repair Lab Requirements
Instrument repairs completed onsite at the Central Iowa Veterans Administration Medical Center (VAMC) shall occur in a mobile repair lab/vehicle in a designated space. CIHCS is not responsible for the supply of any items or utility services of any kind needed for the sustainable functioning of the mobile unit.
Safety cones shall be utilized around the perimeter of the mobile repair vehicle to ensure the safety of hospital and Contractor staff.
Any equipment requiring set up at the mobile repair lab at the hospital shall be done at the expense of the Contractor.
Mobile Repair Unit shall properly display the Contractor s name and permit numbers.
The contractor shall provide access to repair facilities (mobile or otherwise) upon request by the VA to ensure compliance with the contract and applicable regulatory standards.
Contractor mobile unit(s) shall be registered with the CIHCS Police Department.

Contractor documentation and tracking requirements
Accessible online service dashboard that displays and tracks all repair and maintenance activities.
Contractor uses an online dashboard that displays and tracks all repair and maintenance activities.
The dashboard must be online and must be accessible to SPS designees 24 hours a day, 365 days a year except for maintenance related down times.
The following dashboard functions must be included:
Repair request function,
Scheduled maintenance request function,
Critical repair request function,
Display request is received with date of anticipated repair,
Status updates while active repair is being performed,
Closed completed repairs with all associated documentation attached,
Visible annual calendar that establishes an annual PM schedule for sets attached in the appendixes,
The dashboard should allow for all repairer documentation to be attached directly to the repair request
This shall include a preventative maintenance checklist with at least:
Repair performed,
What parts were ordered,
Invoices,
Any other related documentation,
Repair services that Interface with current equipment and Censitrac program are preferred.

Contract Monitoring:
The CIHCS SPS shall designate a representative to monitor Contractor employee work services through one or a combination of the following mechanisms:
The SPS representative, SPS Chief, Reusable Medical Equipment (RME) Coordinator and/or Contracting Officer Representative (COR) shall monitor Contractor instrument pick-up and drop-off through the inhouse Censitrac system to ensure that services called for in the contract have been received by the CIHCS.
SPS shall utilize Contractor s digital dashboard to request services from Contractor. Daily monitoring of digital dashboard and repair status to ensure all requests are being handled appropriately.
Documentation of services performed shall be reviewed by the Contracting Officer Representative prior to certifying payment.
The SPS representative will conduct periodic customer service interviews with end users to confirm quality repair services are being performed to their standards.
Contract monitoring and recordkeeping procedures should be sufficient to ensure proper payment and confirmation that services were provided.
Monthly invoices shall be submitted to the SPS Representative and COR at the beginning of the contract, until it is determined that billing documentation meets requirements. Once billing practices have been found to be acceptable then invoices may be directly submitted to Tungsten. The COR shall verify that services were performed against Contractor s certified delivery repairs document. Only after verification are invoices certified for payment. Billing disagreements that cannot be resolved by the COR shall be forwarded to the Contracting Officer for review and resolution.
The CIHCS SPS representatives retain the option to perform site visits of Contractor repair facilities to confirm that repairs are being performed in accordance with the requirements listed above.
The Contractor shall provide monthly reports as requested, detailing the work performed that month.

Contractor Requirement
The Contractor shall provide documentation of staff training, competencies, and any pertinent certifications in relation to the repairs they shall be conducting.
The contractor shall provide CIHCS SPS staff with in-service training on as needed basis, at the request of the facility. Up to a total of six (6) hours, two (2) per shift, CEU eligible in-services, on instrumentation, per year.

Security Clearance
The following security language is applicable to Contractor staff who will regularly enter CIHCS facilities.
Contractor staff will utilize a temporary Contractor s security badge until a permanent security PIV badge can be issued. Temporary badge use will not exceed 30 calendar days.
The Contractor shall comply with Central Iowa VAMC security, access, and badging requirements. Employees must provide fingerprints and be able to pass a background check so they can obtain a security access badge.
All Contractor staff will need a valid individual personal or professional email account that can be easily checked. Notifications regarding fingerprint scheduling/appointments, background investigation tasks, and Training Management System (TMS) required classes will be sent to their email address throughout the badging process.
The Contractor will submit all required security badging documents for each employee within fifteen (15) business days from the award date of contract to the COR. All documents must be legible. The following documents will be sent to the Contractor via email after contract is awarded.
OF 306 Must be Typed. Submission of handwritten forms will not be acceptable.
Self-Certification
VA 10-2417
Employee Fingerprint Resource Form
Appropriate Contractor staff (as determined by the VA) performing the duties of the Statement of Work shall complete the computer-based training course TMS 10176 Infosec/Rules of Behavior .
Contractor staff shall be escorted while in CIHCS sensitive locations or without a security badge or PIV badge.

Additional Information
National Holidays. There are eleven (11) holidays observed by the Government as follows: New Year s Day, Martin Luther King Day, Presidents Day, Memorial Day, Juneteenth Independence Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas Day. SPS is a 24/7 operation and continues sterilization operations on these holidays.
Repairs must be performed in a clean and orderly environment.

Instrument Classes (Including but not limited to):
General Scissors:
Metz Scissors, Mayo Scissors, Cast/Bandage Scissors, Iris Scissors, Suture Scissors, Serrated Scissors, Delicate Scissors
Osteotomes:
Total Joint Osteotomes, Podiatry Osteotomes and ENT Osteotomes
Curettes:
Total Joint, Curettes, D & C Curettes, Adenoid Curettes
Elevators:
Periosteal Elevators, Cobb Elevators, Key Elevators, Freer Elevators, DIE Elevators
Gouges:
Total Hip Gouges
Small Knives:
Amputation Knives, Cartilage Knives, Meniscus Knives, Knife Handles
Rongeurs:
AB Rongeurs, Pituitary Rongeurs, Kerrison Rongeurs, Kerrison Punches, Dermal Punches
Cutters:
Bone Cutters, Wire Cutters, Pin Cutters, Rib Cutting Forceps
Forceps/Clamps:
Artery Forceps, Sponge Forceps, Kelly Forceps, Adson Forceps, Allis Forceps Tissue Forceps, Mosquito Forceps, Biopsy Forceps, Hemostats, Clip Appliers, Kocher Clamps, Towel Clips/Clamps, Bone Clamps
Miscellaneous Instruments:
Reamers, Total Hip Cup Graters, Cranial Burrs, Enlarging Burr, Retractors, Balfour Retractor, Hand Retractors, Dental Instruments and Hand Pieces, Perforating Twist/Spinal Drills, Chisels, Tonsillectomies, Adenotomes, Trocars, Skin Hooks, Skin Rakes, Suction Tips/Tubes, Dissectors, Rasps, Mouth Gags, Saw Blades, Speculums, Dilators, Dental Instruments, all needle holders, Acetabular Cutters
Ophthalmic Instruments:
Speculums, Retractors, Knives (not diamond), Spoons, Punches, Spatulas, Manipulators, Loops, Hooks, Markers, Calipers, Scissors, Forceps
Arthroscopic Instruments:
Punches, Shavers, Scissors, Intra-Articular Hooks, Intra-Articular Knives, Intra-Articular Graspers, Forceps
Align/Sharpen Laparoscopic Instruments:
Laparoscopic Punches, Laparoscopic Shavers, Laparoscopic Scissors, Laparoscopic Hooks, Laparoscopic Knives, Laparoscopic Graspers, Laparoscopic Forceps
Micro Instruments:
Verres Needles, Biopsy Needles, Corneal Scissors, Urethra tomes, Micro Rongeurs, Micro Forceps Micro Scissors
Bi-Polar Repairs:
Standard Bipolar, Irrigating Bipolar, Standard Bipolar, Irrigating Bipolar
Sterilization Container Repair:
Aesculap, Katena, Case Medical
Endoscopic and Laparoscopic Instruments (modular and non-modular):
Graspers, dissectors, scissors, clamps, biopsy instruments and forceps (to include with or without ratchets).
Light Cables and adaptors to fit all manufacturers:
Light Cable 3mm x 6 ft w/2 adaptors, Light Cable 3mm x 8 ft w/2 adaptors, Light Cable 4mm x 6 ft w/2 adaptors, Light Cable 5mm x 6 ft w/2 adaptors, Light Cable 5mm x 8 ft w/2 adaptors

The lists provided below are not all inclusive of the instruments that will be on the contract over its lifetime and may be subject to change over time.
APPENDIX A:
Critical sets: Appendix A- high risk, low volume.
Service
Container Name
Number of Sets
Instrument
OR - Eye
Cataract Trays
10
35
Dental
Straumann Implant Kit with AS
5
16
OR Pain
Halyard Nitinol RF Probe, 145mm STR
8
2
OR - Retractor
Retractor Set
5
27
OR - TPX
TPX Set New
5
17
OR - Lesion
Lesion Set
6
28
OR - Basic
Basic Set
4
44
OR - Eye
Toric Instrument Set
4
4
OR - Pain
Halyard Nitinol RF Probe, 100mm STR
8
2
OR - Ortho
Ortho Basic
4
44
OR - General
Lap Chole Set New 2018
4
22
Clinic
Minor Clinic
2
19
Dental
Standard Oral Surgery
6
25
OR - Power
Stryker System 7 Large Power
4
11
OR - Laparoscopic
Stryker LAP 4K Camera
8
2
OR - General
Rectal Set
3
26
OR - Power
Saw, Precision Oscillating Tip
4
1
OR - Power
Stryker CD4 Small Power
3
11
OR - General
Needle Holder & Knot Pusher 2018
2
5
OR - Eye
Lacrimal Duct Probes
1
4
OR - General
Closure Tray
2
19
OR - Delicate
Duet Forcep
2
3
OR - Eye
Pterygium (Plastics Eye Tray)
2
26
OR - General
Bookwalter Bars
1
8
OR - General
Bookwalter Blades
2
21
OR - General
Bookwalter Bar #2
1
9
OR - Vascular
CV Set New
3
44
OR-Vascular
CV Extra s Set
1
14
OR - Laparoscopic
Karl Storz Scope Holder
2
6
OR - Retractor
Balfour Retractor Regular
1
8
OR - Retractor
DeBakey Balfour Retractor Deep
2
4
OR - Pain
Halyard Nitinol RF Probes, 54mm STR
2
2
OR - General
Lap Chole Extras 2018
2
12
OR - Laparoscopic
Princeton Long Laparoscopic Set
2
43
OR - General
Adjustable Bookwalter Ring/Bar (Codman)
1
12
OR - Ortho
Ankle Distractor
1
3
OR - General
Bookwalter Blades Extras
1
10
OR - Retractors
St. Mark Retractor 9 Angled Lip Fiberoptic
2
3
OR - Eye
Katena Cataract Extras
4
4
OR - Vascular
Thompson Bar
2
5
OR - Vascular
Thompson Blade Pan
2
19
OR - Retractor
Grand/Henley Retractor
1
7
OR - Retractor
Henley Smooth Blades
1
3
OR - Retractor
Lighted Thorlakson Retractors
1
3
OR - Retractor
Retractor Anal Parks Set
1
7
OR - Vascular
Thompson Carotid Extras
1
6
OR - Vascular
Thompson Liver Blade Extras
1
8
OR - Retractors
Thorlakson Retractors
1
3
OR - Vascular
Thompson Carotid Bar Set
2
3
OR - Vascular
Thompson Carotid Bar Pan
2
25
OR -Vascular
Thompson Knuckles & Discs
2
32
OR - Retractor
Retractor Balfour Pedi Abdominal 3 ½
1
6
OR - Vascular
Vascular Extras
1
13
OR/Clinic - GU
Vasectomy
5
11
OR - GU
Cysto Offset Ureteroscope
1
3
OR - Vascular
Carotid Bar with 1 Knuckle set
1
3
OR - Scope
Thoracoscopy Set
1
18
OR - Vascular
Scanlon Tunneler Set
3
5
APPENDIX B:
Routine Sets: Appendix B: Preventative Maintenance Schedule
May be removed from site for up to 7 DAYs
Service
Container Name
Number Of Set
Inst
Dental
Restoration
20
32
Dental
Hygiene
28
15
OR - Podiatry
Podiatry Set
6
57
Dental
Dental Exam
43
5
Dental
Dental Hygiene Student
12
13
Dental
Straumann Implant Kit
10
1
Dental
3 Shape Trios 4 Scanner Tip
5
13
Dental
Triodent V-Ring Kit
10
2
OR - Ortho
De Mayo Knee Positioner Base Case
3
1
ER
Facial Laceration Tray
8
6
Dermatology
Derm Tray
8
9
Dental
Dental Lamb Extras
2
1
OR - Ortho
Hand Set
4
36
OR - Ortho
New OR De Mayo Knee Positioner Acc Case
3
2
Dental
Dental Denture Adjustment Kits
30
8
OR - General
Acufex Set
1
15
OR - Ortho
Knee Universal Patellar INST Tray
2
35
OR - Laparoscopic
Laparoscopic TEP Extras
1
9
OR - Ortho
Stryker Fluted Headless Pins (x4)
5
4
Specials
SPR Lesion Set
7
10
OR - Ortho
Stryker Ortho Biters
1
19
OR - Ortho
Ortho Shaver Set
3
16
Dental
Dental Cindy Extras
2
9
OR - Ortho
S&N GEN II Reamers 10-12-14MM
2
3
OR - Ortho
Elevators Key Ortho
1
5
Dental
Straumann Novaloc
4
3
OR - Ortho
Synthes Mini Frag Set (Back-up)
1
34
Dental
Dental Hygiene Perio
6
16
OR - Arthroscope
Stryker 4mm 30 degree Arthroscope Set
3
2
OR - Retractors
Hill Ferguson Retractors Set
4
3
OR - Ortho
Stryker Backup Ortho Biters
7
64
Dental
Dental Titanium Implant Scaler Kit K-1800
6
5
OR - Ortho
Stryker Small Joint Inst.
2
15
OR - General
Retractor Hill/Ferg Lighted (Rectal)
2
4
OR - General
New Hemorrhoid Bander Set
8
5
OR - General Surgery
Long Instrument sets
4
30
Dental
Lundy Extras
2
10
Dental
Nobel Implant Kit
2
3
OR - Podiatry
Arthrex Ankle Distractor
2
8
OR - General
Bowel Clamps
4
12
OR - Ortho
Shukla Mini Screw Extraction Set
2
29
OR - Retractor
Henly Retractor Set
3
7
Dental
Dental Garrison Ring Kit
4
3
Dental
Dental Student Extras
2
3
OR - Ortho
Shukla Univ. Screw Extraction Set
2
29
OR - Ortho
Bone Holding Forcep & Large Ankle Forcep
1
11
OR - Ortho
Cement Removal Instruments
1
32
OR - Ortho
Currettes (Ortho)
1
9
OR Ortho
Steinmann Plain Pin Set
1
60
OR - Ortho
Synthes LCP Lg Fragment Inst Locking
1
57
OR - Ortho
Knee P/S Tibial Insert Trial Tray
2
24
OR - Arthroscopic
Stryker 4mm 70 Deg Arthroscope Set
2
2
OR - Ortho
Shukla Maxi Large Screw Extraction
2
38
OR - Power
Stryker Reciprocating Saw Set
3
1
Dental
McGarvey Extras
2
3
OR - Ortho
Osteotomes
2
4
OR - Ortho
Bone Biopsy Instruments
1
6
OR - Ortho
Cannulated Screw Set Extras
1
13
OR - General
Dallo Miles
1
7
OR - Ortho
Hand Osteotomes
1
5
OR - General
Injector Capsule Tension Ring
1
1
OR - General
Liston Amputation Knife
1
1
OR - General
Neuro Osteotomes
1
11
OR - Ortho
Screw Removal Set
1
55
OR - Ortho
Steinmann Threaded Pin Set
1
60
OR - Ortho
Synthes D.C.P Plates
1
44
OR - Ortho
Synthes LC-DCP DCP Basic Inst Set Lg Frag
1
56
OR - Ortho
Synthes Mini Fragment Self Tapping
1
258
OR - General
Amputation Pack
3
5
Dental
Straight-Post red
8
5
OR - General
Hemorrhoid Bander Set
2
6
OR - General
Henley Blades 1 1/2 (4 blades)
2
4
OR - Laparoscopic
Stryker 10mm 0 & 30 degree Lap Lens Set
2
4
OR - Arthroscopic
Stryker 2.7mm 30 degree Arthroscope
2
2
Dental
Standard Dental Endo
3
28
Dental
BlisSonic Scaling Tips
12
3
OR - Vascular
Aortic Set
2
23
OR- Eye
Crawford Lacrimal Intubation Set
1
2
Dental
Dr. Monson Rubber Dam Clamps
1
11
OR - Ortho
Craig Bone Biopsy Set
1
8
OR - General
Curette Neuro Short
1
8
OR - Ortho
Ortho 6.5mm Cannulated Screw Set
1
137
OR - Retractors
St Marks 7 and 9 Retractors Fiberoptic
1
3
OR Ortho
Stryker Core Saber/PI Drive 2 Plus Drill
1
6
OR - Ortho
Synthes LCP Large Fragment Plates
1
34
OR - Ortho
Synthes LCP Large Fragment Screw Set
1
543
OR - General
Table Top Plate Bender
1
1
OR - General
Trocar Irrigating Canula
1
4
OR - Eye
Cataract Extras
3
10
OR - General
Biomet CTR Angled Heiss Set
2
2
OR - Cardiothoracic
Chest Set
2
38
OR - Cardiothoracic
Finochietto Pediatric Rib Spreader
2
1
OR - General
Gallbladder Set
2
12
OR - Emergency
Tracheostomy Set
2
45
Dental
Red ParaPost XP Kit
1

Dental
Yellow ParaPost XP Kit
1

OR - Ortho
Plantar Fasciotomy
1
6
OR - Eye
Eye Enucleation Set
1
11
OR - General
Medline Crossroads Cotton Trials 5-6, 7-8
1
2
OR - Power
Stryker Corded High Torque Drill
1
6
OR - General
Thyroid Pan
1
27
OR - General
Unfolder Handpiece
1
1
Dental
Dental Endo Files 30mm
5
7
Dental
Dental Gates Glidden Kit
2

OR-GU
TUR Set
8
29
OR-Ortho
Affiniti Humeral Bottom Tray (Tornier)
2
31
OR-Ortho
Affiniti Humeral Middle Tray (Tornier)
2
18
OR-Ortho
Affiniti Humeral Top Tray (Tornier)
2
21
OR -Ortho
Allen shoulder Holder New
1
3
OR-Ortho
Allen Shoulder Holder Old
1
2
OR-Eye
Amo Ophthalmic Emerald Unfolder Delivery System
1
1
OR-Ortho
Arthrex MIS Handpiece Set New
2
3
OR-Ortho
Arthrex MIS Instrument Set New
2
4
OR-Vascular
AV Fistula Set
3
5
OR-Vascular
AV Sheath Tunneler
1
20
OR-Ortho
Bone Spikes
1
5
OR-Ortho
Cannulated Screw Set Extras
1
12
Or-Retractor
Charnley Amstutz Extras
1
3
OR-Retractor
Charnley Retractor Set
2
14
OR-GU
Circumcision Tray
2
10
OR-Emergency
Cooley Sternotomy Spreader Adult Set
1
3
OR-Ortho
Cutting blocks Langs Favorite
1
4
OR-Ortho
DeMayo Knee Positioner Base Case
3
1
OR-Ortho
Dr. Olswing s Knee Extras
1
9
OR-vascular
Garrett Dilators x9
2
9
OR-Ortho
Hemi-Arthroplasty Set
2
40
OR-Retractor
Henley Smooth Blades
1
3
OR-Vascular
Kelly Wick Tunnler
1
14
OR-Ortho
Knee ACF Cut Blocks & Ream Fem Trials
2
18
OR-Ortho
Knee ACF Femoral Instrument Tray
2
22
OR-Ortho
Knee CR Tibial Insert Trial Tray
2
44
OR-Ortho
Knee Femoral Miscellaneous
2
16
OR-Ortho
Knee Holder
2
1
OR-Ortho
Knee P/S Ream Through Femoral Tray
2
13
OR-Ortho
Knee P/S Tibial Insert Trial Tray
2
24
OR-Ortho
Knee Tibial Instrument Tray
2
30
OR-Ortho
Knee Tibial Miscellaneous Tray
2
15
OR-GU
Lens Cysto 70 degrees
4
1
OR - Vascular
Mediastinoscopy
1
20
OR-Vascular
Mediastinoscopy Extras
1
9
OR-GU
Olympus 110 Deg Cysto Lens
1
1
OR-GU
Olympus Gyrus Set
4
4
OR-GU
Olympus Long Resectoscope Set
1
7
OR-GU
Olympus Urethrotome Blade & Knife
1
2
OR-GU
Olympus Urethrotome Set
1
7
OR-Ortho
Ortho 6.5mm Cannulated Screw Set
1
138
OR-Power
Oscillating Saw Stryker
1
1
OR - Retractors
O Sullivan O Connor retractor w/4 Blades
1
5
OR-GU
Penile Dilators
1
7
OR-GU
Penile Prothesis BackUp Set
1
27
OR-GU
Penile Prosthesis
1
27
OR-Vascular
Probe, Pencil, Doppler, 8MHZ (Koven)
1
1
OR-GU
Prostatectomy
1
30
OR-Vascular
PV Sheath Tunneler
1
8
OR-Ortho
R3 Hip Main Inst Tray
2
21
OR-Ortho
R3 Reamer Dome Tray
2
27
OR-Ortho
R3 Trial Shell Tray
2
21
OR-GU
Rigid Ureteroscope MR-6LA
4
3
OR-Ortho
S&N Small Joint Shaver
1
1
OR-Ortho
Shoulder Mini-Open Retractor
1
7
OR-Ortho
Shoulder Set
2
19
OR-Ortho
Small Joint Arthroplasty System
1
18
OR-GU
Sounds Lefort Urethral (10Fr-30Fr)
1
11
OR-GU
Sounds Van Buren Urethral
2
8
OR-Ortho
Steinmann Threaded Pin Set
1
60
OR-Power
Stryker Core Saber/PI Drive 2 Plus Drill
1
6
OR -Ortho
Synergy Broach Tray Hip
2
34
OR-Ortho
Synergy Femoral Reamer Tray (Hip)
2
13
OR-Ortho
Synthes LCP Lg Fragment Inst Locking
1
57
OR-Ortho
Synthes LCP Sm. Frag Inst & Implant Set 1A
1
63
OR-Ortho
Synthes LCP Sm Frag Inst & Implant Set 1
1
612
OR-Ortho
Tornier Affiniti Glenoid Instrument Set
1
39
OR-Ortho
Total Shoulder Retractor
2
9
OR-Ortho
Total Shoulder Extras
2
6
OR-Ortho
Unipolar Trial
1
26
OR-Vascular/GU
Yasergil Appliers
3
2
OR-Retractor
Parsonnet Epicardial Retractor
1
2
OR-Retractor
Retractor Balfour Pedi Abdominal 1 ½
1
2
OR-Gyn
Abdominal Hysterectomy Set
1
32
OR-Gyn
D & C Set
2
26
OR-Gyn
Gyn LEEP Set
2
5
OR-Gyn
Hegar Uterine Dilator Set
1
11
Attachments/Links
Contact Information
Contracting Office Address
  • 316 Robert Street N Suite 506
  • Saint Paul , MN 55101
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jun 10, 2026 09:46 am CDTSources Sought (Original)
Commodity Codes
  • FSC JMaintenance, Repair, and Rebuilding of Equipment
Related bids
Jun 12, 2026[Sources Sought (Updated)] J066--Des Moines VAHCS Surgical Instrument Maintenance Sources Sought
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.

Government Bids

Empower Your Bidding Strategy

Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.

  • Access an extensive database of bids, including comprehensive local and state opportunities.
  • Receive customized alerts for the bids that matter most to your business.
  • Explore detailed specifications to ensure precise and competitive submissions.
  • Gain a competitive edge with up-to-date information and exclusive opportunities.

See Also

Auto Body Repair Services

Bid Information Bid Number 005-RFB-2838-2026 Solicitation Auto Body Repair Services Solicitation Type Request

State Government of Iowa

Bid Due: 7/30/2026

Power Plant-Condenser Water P...

Power Plant-Condenser Water Piping Repairs Phase 2 Prebid Meeting: 7/1/2026 9:00:00 AM Prebid

Iowa State University

Bid Due: 7/16/2026