Silver Sands Middle - Replace Stage Lighting and Sound System
Project Information
- Bid Title
- Silver Sands Middle - Replace Stage Lighting and Sound System
- Issuing Agency
- Volusia County Schools
- Location
- Florida
- Published Date
- Feb 26, 2026
- Closing Date
- Mar 24, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Project No. 2548133
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Silver Sands Middle - Replace Stage Lighting and Sound System - Project No. 2548133
Mandatory Prebid Meeting: Feb. 26, 2026 at 10:00 AM Bid: March 24, 2026 at 1:30 PM Project Bid Documents: Plans
Project Manual
Prebid Sign-in SheetsEstimate: $800,000 Consultant: SGM Engineering, Inc.
Mark Escott
(407) 767-5188Owner: VCS Project Manager
Clayton Simons
(386) 947-8786Bid Status: Active - Attachment Preview
-
VOLUSIACOUNTY SCHOOLS"LEADING WITH GRACE AND RESPECT"THE SCHOOL BOARD OF VOLUSIACOUNTY FLORIDA200 North Clara AvenueDeland, Florida 32720SILVER SANDS MIDDLEREPLACE STAGE LIGHTINGAND SOUND SYSTEMVCS Project NO. 25481331300 Herbert St.Port Orange, FL 32129SCHOOL BOARDMEMBERSJAMIE M. HAYNESRUBEN COLONDONNA BROSEMERKRISTA GOODRICHJESSIE THOMPSONBOARD CHAIRBOARD VICE CHAIRMEMBERMEMBERMEMBERCARMEN J. BALGOBINSUPERINTENDENTDESCRIPTION OF WORKREMOVE EXISTING STAGE LIGHITNG AND SOUND SYSTEM. PROVIDE NEW STAGE LIGHTING FIXTURES, CONTROLS,SUPOPPORTS, OUTELTS, CONDUIT AND WIRING. NEW SOUND SYSTEM INCLUDING EQUIPMENT, SPEAKERS, SUPPORTS,MICS, WIRELESS MICS, AMPLIFIERS, MIXERS, CONDUIT AND WIRE.ENGINEERS & CONSULTANTSELECTRICALSGM ENGINEERING935 LAKE BALDWIN LANEORLANDO, FL 32814407-767-5188MARK ESCOTTMARK@SGMENGINEERING.COMWWW.SGMENGINEERING.COMEngineer's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe 2023 Florida Building Code 8th edition.BUILDING DATAA. SURVEY PARCEL IDB. LEGAL DESCRIPTIONC. OCCUPANCY TYPED. CONSTRUCTION TYPEE. RISK CATEGORYF. AUTOMATIC SPRINKLERG. BUILDING AREAH. BUILDING HEIGHTI. OCCUPANT LOADXXXXXXEDUCATIONALTYPE II: EDUCATIONAL3STAGE ONLY157,043XXXXXXLOCATION MAPG001COVER SHEETELECTRICALALL WORK COMPLETED UNDER THE SCOPE OF THIS PROJECT SHALL, AS A MINIMUM, COMPLY WITH THELAWS, RULES, STANDARDS AND DECISIONS WITH THE LATEST AMENDMENTS OF THE GOVERNMENTALUNITS HAVING STATUTORY JURISDICTION OVER THIS PROJECT:a. FLORIDA BUILDING CODES 8TH EDITION (2023)b. NATIONAL ELECTRIC CODE, NFPA 70 (2020)c. NATIONAL FIRE-ALARM CODE, NFPA 72 (2019)d. FLORIDA FIRE PREVENTION CODE 8TH EDITION (2023)e. STATE REQUIREMENTS FOR EDUCATIONAL FACILITIES (SREF) - 2014 ED.f. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)E001ED201E201E501E701E801E802ELECTRICAL NOTES, SYMBOLS ANDSPECIFICATIONSELECTRICAL DEMO LIGHTING & POWER FLOOR PLANELECTRICAL LIGHTING & POWER FLOOR PLANELECTRICAL ONE LINE DIAGRAMSELECTRICAL PANEL SCHEDULESELECTRICAL DETAILSELECTRICAL DETAILSSYSTEMSES001ESD201ES201ES601SYSTEMS LEGENDSYSTEMS DEMO FLOOR PLANSYSTEMS FLOOR PLANSYSTEMS BLOCK DIAGRAMSCA-00006208935 Lake Baldwin LaneOrlando, Fl. 32814Tel: 407-767-5188Fax: 407-767-5772www.sgmengineering.comCopyright © 2025 SGM Engineering, Inc.SGM #: 2024-379NOT TO SCALECONSTRUCTION DOCUMENTS 10/13/25ENGINEERMARK A. ESCOTTDESIGNED BYDRAWN BYENGR OF RECORDISSUE DATE10/13/2025AE PROJECT NUMBER2024-379SHEET TITLECOVER SHEETDRAWING NO.G001LIGHTING FIXTURES1'x4' FIXTURE2'x2' FIXTURE2'x4' FIXTURE4' WALL MOUNT FIXTURE4' WALL MOUNT FIXTURE, EMERGENCY1'x4' FIXTURE, BATTERY/EMERGENCY2'x2' FIXTURE, BATTERY/EMERGENCY2'x4' FIXTURE, BATTERY/EMERGENCY4' STRIP FIXTURE4' STRIP FIXTURE, BATTERY/EMERGENCY4' STRIP FIXTURE, WALL MOUNTED4' STRIP FIXTURE, WALL MOUNTED,BATTERY/EMERGENCYTRACK FIXTURECEILING MOUNTED RECESSED, DOWN LIGHTCEILING MOUNTED RECESSED, EMERGENCY DOWN LIGHTSURFACE MOUNTED LIGHTING FIXTUREWALL MOUNTED SCONCE FIXTURE, BATTERY/EMERGENCYEMERGENCY LIGHT FIXTURESINGLE FACE EXIT LIGHT FIXTURE ARROW INDICATESDIRECTION OF EGRESSDOUBLE FACE EXIT LIGHT FIXTURE ARROW INDICATESDIRECTION OF EGRESSSWITCHESSSWITCHS2SWITCH, 2 POLES3SWITCH, 3-WAYS4SWITCH, 4-WAYSaSWITCH, 1 POLE, LETTER INDICATES SWITCHLEG CONTROLLED.SLSDSD3SWITCH, LOW VOLTAGE MOMENTARY, HUBBELL I-557I OR EQUALSWITCH, 0-10 VOLT DIMMING, LUTRON DIVA DVSTV OR EQUALSWITCH, THREE-WAY, 0-10 VOLT DIMMING, LUTRON DIVA DVSTV OREQUALSTSWITCH, 120/277 VAC. LINE VOLTAGE ROTARY TIMER WITH HOLD-ON,TORK A506HH OR EQUALLIGHTING CONTROL DEVICESTCTIMECLOCKPOWER DEVICESSINGLE RECEPTACLEDUPLEX RECEPTACLEDOUBLE DUPLEX RECEPTACLEABOVE COUNTER DUPLEX RECEPTACLEDUPLEX RECEPTACLE, HALF SWITCHEDSPECIAL PURPOSE RECEPTACLESINGLE 250V NON-LOCKING TYPE RECEPTACLECDUPLEX RECEPTACLE FOR COMPUTER WORKSTATIONCQUAD RECEPTACLE FOR COMPUTER WORKSTATIONDUPLEX RECEPTACLE FOR TV LOCATED AT 84" AFF UNLESSTVNOTED OTHERWISE.DUPLEX RECEPTACLE FOR TV LOCATED AT 18"AFF. LOCATE INTVCOMMON BOX WITH CCTVDUPLEX RECEPTACLE FOR INTERACTIVE BOARD. SEE DETAIL 1IBON SHEET ES801.CEILING MOUNTED RECEPTACLERECESSED FLOOR RECEPTACLEDUPLEX RECEPTACLE, GROUND FAULTDUPLEX RECEPTACLE, GROUND FAULT, ABOVE COUNTERQUAD RECEPTACLE, GROUND FAULTDISCONNECT SWITCHMOTOR STARTERSTARTER/DISCONNECT SWITCHVFDVARIABLE FREQUENCY DRIVEJJUNCTION BOXJFLOOR MOUNTED JUNCTION BOXCEQUIPMENT CONNECTIONDOOR BELL PUSH BUTTONTTRANSFORMERSTSHUNT TRIP. MTD. AT 6'-5" AFF/AFG TO TOP OF ENCLOSUREMOTORGROUND BUS BARGROUND ROD WITH TEST INSPECTION WELL. SEESPECIFICATIONS.SPDSURGE PROTECTION DEVICE, SEE SPECIFICATIONS.LCLIGHTING CONTACTORTHEATRICAL DEVICESDT*DUAL ULTRASONIC/PIR-CEILING MOUNT SENSOR, 24 VDC/VAC,35mA. WATTSTOPPER DT-305 OR EQUAL.W*DUAL ULTRASONIC/PIR-WALL MOUNT SENSOR, 24 VAC/VDC, 35mA.WATTSTOPPER DT-205 OR EQUAL.HB*PIR-CEILING MOUNT HIGH-BAY SENSOR, 24 VDC/VAC, 500mA., 360 °LENS, HUBBELL WASP 2 OR EQUAL.SN2SN4MKXTHEATRICAL LIGHTING NETWORK WALL SWITCH, 2 BUTTON PRESETTHEATRICAL LIGHTING NETWORK KEYED WALL SWITCH, 4 BUTTONPRESETTHEATRICAL LIGHTING 2 PORT DMX GATEWAYD1DUAL ULTRASONIC/PIR-WALL SWITCH DECORATOR MOTION SENSOR,120/277VAC, 800/1200W. VANDAL RESISTANT LENS. WATTSTOPPERIONTHEATRICAL LIGHTING CONTROL CONSOLEDW-100 OR EQUAL.TWWTHEATRICAL LIGHTING STAGE WIREWAY CONNECTION POINTLVSUL 924 LISTED FAILSAFE EMERGENCY SWITCHING RELAY, LVS EPC-DOR EQUAL. LOWER CASE LETTER NEXT TO DEVICE INDICATESSWITCHLEG CONTROLLED. PROVIDE LABEL ON GRID OR ACCESSTPBTHEATRICAL LIGHTING PLUGBOXPANEL TO IDENTIFY RELAY LOCATION.PPPOWER PACK 120/277 VAC; 20 AMPS, 225mA SECONDARY.WATTSTOPPER BZ-250 OR EQUAL.*FOR LOW VOLTAGE OCCUPANCY SENSORS, PROVIDE POWERPACK(S) 120/277 VAC; 20 AMPS, 225mA SECONDARY AS NEEDED FORZONE/AREA CONTROL. WATTSTOPPER BZ-250 OR EQUAL.POWER DISTRIBUTION120/208V PANELBOARD, RECESSED120/208V PANELBOARD, SURFACE MOUNT277/480V PANELBOARD, SURFACE MOUNT277/480V PANELBOARD, RECESSED1R1-1FEEDER OR BRANCH CIRCUIT CONCEALED IN WALL,CEILING OR FLOORHOMERUN CONSISTING OF ONE SINGLE-PHASE, 1-POLE CIRCUIT, SEESPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.PANELBOARD AND CIRCUIT DESIGNATION ARE INDICATED.MISCELLANEOUS SYMBOL LEGENDDETAIL NUMBERTITLE 1E200 SCALE:DETAIL TITLE REFERENCEE200SHEET NUMBER WHERE DETAIL IS REFERENCEDADDITIONAL SHEET REFERENCESXXXX.XXDETAIL NUMBERSHEET NUMBER TO WHERE DETAIL IS REFERENCEDABBREVIATIONSAAMPERESAEAUDIO ENHANCEMENTAFCABOVE FINISHED CEILINGAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEAICAMPERES INTERUPTINGCAPACITYALALUMINUMAWGAMERICAN WIRE GAUGEBFCBELOW FINISHED CEILINGBFGBELOW FINISHED GRADECCONDUITCABCABINETCKTCIRCUITCLGCEILINGCLCENTERLINECT'sCURRENT TRANSFORMERSCUCOPPERDISCDISCONNECT(ING)DWGDRAWING(S)EAEACHECBENCLOSED CIRCUIT BREAKEREFEXHAUST FANEMTELECTRICAL METALLIC TUBINGEQUIP EQUIPMENTEUHELECTRIC UNIT HEATEREWCELECTRIC WATER COOLEREWHELECTRIC WATER HEATEREXHEXHAUSTEXIST EXISTINGEXPEXPLOSION PROOFFAFIRE ALARMFLAFULL LOAD AMPERESFLUOR FLUORESCENTGFCIGROUND FAULT CIRCUITINTERRUPTERGFPGROUND FAULT PROTECTIONGNDGROUNDHGTHEIGHTHIDHIGH INTENSITY DISCHARGEHPSHIGH PRESSURE SODIUMHOAHAND-OFF-AUTOMATICHPHORSEPOWERHVAC HEATING/VENTILATING/AIR CONDITIONINGHVHIGH VOLTAGEINCINCANDESCENTJBJUNCTION BOXkVKILO-VOLTSkVAKILO-VOLTS-AMPERESkVAR KILO-VOLTS-AMPERES REACTIVEkWKILO-WATTSkWHKILO-WATT-HOURSLTGLIGHTINGmMETERmmMILLIMETERMAXMAXIMUMMCBMAIN CIRCUIT BREAKERMCCMOTOR CONTROL CENTERMCPMOTOR CIRCUIT PROTECTORMFRMANUFACTURERMHMETAL HALIDEMINMINIMUMMISC MISCELLANEOUSMLOMAIN LUG ONLYMMSMANUAL MOTOR STARTER SWITCHMTRMOTORMTDMOUNTEDMTGMOUNTINGNACNOTIFICATION APPLIANCE CIRCUITNECNATIONAL ELECTRICAL CODENLNIGHT LIGHT, UNSWITCHEDPNLPANELPSIPULL STATION INSIDEPVCPOLYVINYL CHLORIDERECRECEPTACLERGSRIGID GALVANIZED STEELSPDSURGE PROTECTION DEVICETELTELEPHONETYPTYPICALUONUNLESS OTHERWISE NOTEDVVOLTSVAVOLT-AMPERESVFDVARIABLE FREQUENCY DRIVEWWATTSWPWEATHER PROOFXFMR TRANSFORMER1M1-1:3HOMERUN CONSISTING OF ONE SINGLE-PHASE, 2-P0LE CIRCUIT:SEE SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRESIZES. PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.1R1-1,3HOMERUN CONSISTING OF TWO SINGLE-PHASE CIRCUITS: SEESPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.PANELBOARD AND CIRCUIT DESIGNATION ARE INDICATED.1R1-1,3,5HOMERUN CONSISTING OF THREE SINGLE-PHASE CIRCUITS: SEESPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.1M1-1:3:5HOMERUN CONSISTING OF ONE THREE-PHASE CIRCUITS: SEESPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.CA-00006208935 Lake Baldwin LaneOrlando, Fl. 32814Tel: 407-767-5188Fax: 407-767-5772www.sgmengineering.comCopyright © 2025 SGM Engineering, Inc.SGM #: 2024-379ENGINEERMARK A. ESCOTTDESIGNED BYDRAWN BYENGR OF RECORDISSUE DATE10/13/2025AE PROJECT NUMBER2024-379SHEET TITLEELECTRICAL NOTES,SYMBOLS ANDSPECIFICATIONSDRAWING NO.E001121225121EXISTING PANEL LPP2PSECTION-2EXISTING PANEL LPP2PSECTION-1NELECTRICAL DEMO LIGHTING FLOOR PLANSCALE: 1/8"=1'-0"04'8'16'4443GENERAL NOTES:a. REFER TO SYMBOL LEGEND NOTES ON SHEET E-001.b. REFER TO BOOK SPECIFICATIONS.c. UNLESS OTHERWISE NOTED, WHERE EXISTING CONDUITS ANDCONDUCTORS ARE NOTED TO BE REMOVED, THEY ARE TO BE REMOVED INTHEIR ENTIRETY BACK TO THE POINT OF ORIGIN.d. ALL DEMOLISHED EQUIPMENT AND FIXTURES NOTED TO BE SALVAGED,SHALL BE DELIVERED TO THE OWNER. TRANSPORT ITEMS TO OWNERSDESIGNATED STORAGE AREA WITHIN 25 MILES OF THE SITE. SHOULD THEOWNER DECIDE NOT TO RECEIVE THESE ITEMS, THE CONTRACTOR WILLREMOVE FROM THE SITE AND DISPOSE IN A LEGAL MANNER TO AN EPAAPPROVED LANDFILL. COMPLY WITH ALL NATIONAL, STATE AND LOCALREQUIREMENTS WITH REGARD TO HAZARDOUS MATERIALS REMOVAL,HANDLING AND DISPOSAL.e. REMOVE ALL CONDUIT AND WIRE, FROM REMOVED ITEMS, BACK TO THESOURCE UNLESS IT IS TO BE RE-USED FOR NEW WORK.f.MAINTAIN CIRCUITS TO EXISTING ITEMS THAT ARE NOT BEING REMOVEDSO THAT THEY WILL REMAIN COMPLETELY FUNCTIONAL DURINGCONSTRUCTION AND AT THE COMPLETION OF CONSTRUCTION.g. VISIT THE EXISTING FACILITY AND CAREFULLY EXAMINE THOSE PORTIONSOF THE BUILDING AND SITE AFFECTED BY THIS WORK BEFORESUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH THE EXISTINGCONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE EXECUTION OFTHE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED ASEVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMSFOR DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED.h. COORDINATE WITH THE OWNER AND OWNERS REPRESENTATIVE ANYPOWER OUTAGES THAT MAY AFFECT THE OWNER IN ANY MANNER. 72HOUR PRIOR NOTICE SHOULD BE GIVEN TO THE OWNER FOR ALLCOORDINATED OUTAGES.i.ALL EXISTING ITEMS ARE SHOWN FOR REFERENCE ONLY UNLESSOTHERWISE NOTED.j.THE EMERGENCY LIGHTING IN ALL OCCUPIED PORTIONS OF THE BUILDINGINCLUDING THE EGRESS PATH FOR THOSE OCCUPANTS SHALL BEMAINTAINED ION OPERATING CONDITION AT ALL TIMES THROUGHOUT THECONSTRUCTION.k. NOTIFY THE CONSTRUCTION MANAGER SEVEN (7) DAYS PRIOR TO THESTART OF ANY DEMOLITION WORK. NOTIFICATION SHALL INCLUDE AGENERAL LIST OF SERVICES AFFECTED AND A SCHEDULE OF WORK TO BEPERFORMED.6EXISTING DIMMER PANELPLAN KEY NOTES:#1. EXISTING CEILING SIMPLEX RECEPTACLE IS TO BE REMOVED ALONGWITH BRANCH CIRCUIT WIRE BACK TO THE SOURCE FORREPLACEMENT WITH NEW TWIST-LOCK RECEPTACLE. REFER TORENOVATION PLAN.2. EXISTING CEILING SIMPLEX RECEPTACLE IS TO BE REMOVED ALONGWITH WIRE BACK TO THE SOURCE. PROVIDE BLANK COVER ONEXISTING BOX.3. REMOVE EXISTING THEATRICAL LIGHTING BATTEN/ WIREWAY ANDBRANCH CIRCUIT CONDUCTORS BACK TO THE SOURCE. THISLOCATION WILL BE USED FOR THE NEW BATTENS AND CONNECTORBOXES. REWORK CONDUIT FOR CONNECTION TO THE NEW BOXES .REMOVE ALL LIGHTING OFF BATTENS AND DISPOSE OF UNLESS THEOWNER ELECTS TO KEEP THE FIXTURES FOR FUTURE USE.4. REMOVE EXISTING BORDER LIGHTS, SUPPORTS, BRANCH CIRCUITWIRE, ETC. THESE LOCATIONS WILL NOT BE NEEDED FOR FUTUREWORK. REMOVE ALL LIGHTING AND DISPOSE OF UNLESS THE OWNERELECTS TO KEEP THE FIXTURES FOR FUTURE USE. CONDUIT MAY BEREUSED FOR NEW LIGHTING CIRCUITS.5. EXISTING SUPPORT CHANNEL IS TO REMAIN FOR ADDITIONALSUPPORT OF NEW BATTEN.6. REMOVE EXISTING THEATRICAL DIMMING PANEL. BRANCH CIRCUITSARE BEING REMOVED. THE FEEDER WIRE AND CONDUIT MAY REMAINFOR REUSE.CA-00006208935 Lake Baldwin LaneOrlando, Fl. 32814Tel: 407-767-5188Fax: 407-767-5772www.sgmengineering.comCopyright © 2025 SGM Engineering, Inc.SGM #: 2024-379ENGINEERMARK A. ESCOTTDESIGNED BYDRAWN BYENGR OF RECORDISSUE DATE10/13/2025AE PROJECT NUMBER2024-379SHEET TITLEELECTRICAL DEMOLIGHTING & POWERFLOOR PLANDRAWING NO.ED201NELECTRICAL LIGHTING FLOOR PLANSCALE: 1/8"=1'-0"04'8'16'TYPICAL 1SP-12444GENERAL NOTES:a. REFER TO SYMBOL LEGEND NOTES ON SHEET E-001.b. REFER TO BOOK SPECIFICATIONS.c. MAINTAIN CIRCUITS TO EXISTING ITEMS THAT ARE NOT BEING REMOVED SOTHAT THEY WILL REMAIN COMPLETELY FUNCTIONAL DURING CONSTRUCTIONAND AT THE COMPLETION OF CONSTRUCTION.d. VISIT THE EXISTING FACILITY AND CAREFULLY EXAMINE THOSE PORTIONS OFTHE BUILDING AND SITE AFFECTED BY THIS WORK BEFORE SUBMITTINGPROPOSALS, SO AS TO BECOME FAMILIAR WITH THE EXISTING CONDITIONSAND DIFFICULTIES THAT WILL AFFECT THE EXECUTION OF THE WORK.SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCHEXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR DIFFICULTIESENCOUNTERED WILL NOT BE RECOGNIZED.e. COORDINATE WITH THE OWNER AND OWNERS REPRESENTATIVE ANYPOWER OUTAGES THAT MAY AFFECT THE OWNER IN ANY MANNER. 72 HOURPRIOR NOTICE SHOULD BE GIVEN TO THE OWNER FOR ALL COORDINATEDOUTAGES.f.PROVIDE DEDICATED NEUTRAL FOR ALL CIRCUITS GOING BACK TO THESTAGE PANEL.g. THE EMERGENCY LIGHTING IN ALL OCCUPIED PORTIONS OF THE BUILDINGINCLUDING THE EGRESS PATH FOR THOSE OCCUPANTS SHALL BEMAINTAINED IN OPERATING CONDITION AT ALL TIMES THROUGHOUT THECONSTRUCTION.CA-00006208935 Lake Baldwin LaneOrlando, Fl. 32814Tel: 407-767-5188Fax: 407-767-5772www.sgmengineering.comCopyright © 2025 SGM Engineering, Inc.SGM #: 2024-379JJJSP-2SP-7,8SP-11,12SP-15,16PLAN KEY NOTES:#1. PROVIDE NEW TWISTLOCK RECEPTACLE TO REPLACE SIMPLEXRECEPTACLE REMOVED IN DEMOLITION PHASE. PROVIDE NEW WIREBACK TO THE RELAY PANEL IN EXISTING/MODIFIED CONDUIT.SP-3SP-4JSP-5,6JJSP-9,10SP-13,14555582. PROVIDE NEW PIPE BATTEN AS SHOWN IN DETAIL 3 OF E802. BATTENSHALL ATTACH TO EXISTING CHANNEL IN CEILING FOR 2 SUPPORTS OFTHE FLANGE. THE OTHER 2 SUPPORTS ON THE FLANGE SHALL BESUPPORTED BY THREADED ROD UP TO STRUCTURE ABOVE WITH 1 1/2"UNISTRUT TO SPAN BETWEEN STRUCTURAL MEMBERS IF REQUIREDBASED ON SUPPORT LOCATIONS DIRECTLY ABOVE. CUT, REPAIR ANDPAINT CEILING IF REQUIRED TO GET THE ADDITIONAL SUPPORTSINSTALLED.3. PROVIDE NEW DMX CONNECTION BOX ON WALL FOR CONNECTION TOTHE LIGHTING CONTROLLER. SEE LIGHITNG CONTROL DRAWING FORDETAILS OF CONNECTION AND WIRING. PROVIDE WIRING IN 1"CONDUIT.4. PROVIDE NEW 40' SCH 40 BLACK STEEL PIPE BATTENS AND (2) 2 CKTCONNECTION BOXES WITH (3) PIGTAIL L5-20R TL FEMALE OUTLETS(ETC # 9302C-U) AT 10' IN FROM EACH END OF THE BATTENS FOR NEWTHEATRICAL LIGHTING. RELOCATE EXISTING UNISTRUT SUPPORTS ATCEILING JOIST TO THE NEW LOCATIONS AS SHOWN ON THE DRAWINGS.EXISTING BRANCH CIRCUIT CONDUITS MAY BE MODIFIED/EXTENDEDAND USED BACK TO THE LOCATION OF THE NEW RELAY PANEL. PULLNEW BRANCH CIRCUIT WIRE WITH DEDICATED NEUTRALS BACK TO NEWPANEL RELAY PANEL SP. SEE DETAILS ON E801 FOR ADDITIONAL INFO.7SP-21,22,235. PROVIDE NEW DMX CONNECTION BOX AT BATTEN. FLUSH MOUNT INCEILING AT FOH LOCATION AND SURFACE MOUNT TO STRUT ABOVEBATTEN AT ELECTRICS 1-3.6. PROVIDE NEW RELAY PANEL SP. SEE ONE LINE DRAWING FOR FEEDERINFORMATION. LOCATE NEW DIN MOUNT CONTROL ENCLOSURES6(EDMXC AND RSN-OPTO) ON WALL NEXT TO THE NEW RELAY PANEL.NEW RELAY PANEL SPPROVIDE MIN 3/4" CONDUIT FOR ALL DMX CABLING BETWEEN PANELSAND CONNECTION BOXES. PROVIDE NEW 120V CIRCUIT TO RSN-OPTOAND EDMXC FROM NEW PANEL SP -24.37. PROVIDE NEW RECEPTACLE CIRCUITS FOR NEW AUDIO SYSTEM.8. PROVIDE PRESET SCENE CONTROLLER. SEE ONE LINE ON E801 FORDETAILS.ENGINEERMARK A. ESCOTTDESIGNED BYDRAWN BYENGR OF RECORDISSUE DATE10/13/2025AE PROJECT NUMBER2024-379SHEET TITLEELECTRICAL LIGHTING &POWER FLOOR PLANDRAWING NO.E201UTILITYTRANSFORMER800A400A90A100A90A30A30A30A15A30A30A30A30A30A30A30ATRANSFORMER225 KVATO BLDGML3 HEATPUMP #11SPARESPARERINSETANKDISHWASHERMOTORSDISPOSERWASHTANKL4 HEATPUMP #6PUMP #35 HP480/3L2 HEATPUMP #4PUMP #21 HP480/3PUMP #47-1/2 HP480/3PUMP #55 HP480/3LPP4PSECTION #1277/480V, 3PH, 4W100KAICNEUTRALGROUND24,403 AVAILABLE FAULT CURRENT800A30A60A60A40A60A100A125ASPDSPARE SPAREPANELLLP2ETO BLDGKPANELLLP2FPANELLLP2D100A70A70A400A225A175A60A30ALPP2P120/208V, 3PH, 4W50 KAICNEUTRALGROUNDSTAGEPANEL1SPAREPANELLLP2BTO BLDG TO BLDGMNPANELLLP2CSPARE SPAREDEMOLITION ONE-LINE POWER DIAGRAMNO SCALEUTILITYTRANSFORMER800A400A90A100A90A30A30A30A15A30A30A30A30A30A30A30ATRANSFORMER225 KVATO BLDGML3 HEATPUMP #11SPARESPARERINSETANKDISHWASHERMOTORSDISPOSERWASHTANKL4 HEATPUMP #6PUMP #35 HP480/3L2 HEATPUMP #4PUMP #21 HP480/3PUMP #47-1/2 HP480/3PUMP #55 HP480/3LPP4PSECTION #1277/480V, 3PH, 4W100KAICNEUTRALGROUND24,403 AVAILABLE FAULTCURRENT(AFC)800A30A60A60A40A60A100A125ASPDSPARE SPAREPANELLLP2ETO BLDGKPANELLLP2FPANELLLP2D100A70A70A400A225A175A60A30A3,394 AFCSPARESTAGEPANEL2PANELLLP2BTO BLDG TO BLDGMNPANELLLP2CSPARE SPARELPP2P120/208V, 3PH, 4W50 KAICNEUTRALGROUNDRENOVATION ONE-LINE POWER DIAGRAMNO SCALEGENERAL NOTES:a. REFER TO SYMBOL LEGEND AND GENERAL NOTES ONSHEET E001.b. REFER TO BOOK SPECIFICATIONS.c. REFER TO PANEL FEEDER SCHEDULES FOR ALL NEWPANEL FEEDER CONDUIT AND WIRE SIZES.d. REFER TO EQUIPMENT SCHEDULES ON E600 SERIESSHEETS FOR DISCONNECT, CONDUIT AND WIRE SIZESFOR EQUIPMENT.e. ALL FEEDERS ARE TO HAVE LESS THAN 2% TOTALVOLTAGE DROP AND ALL BRANCH CIRCUITS SHALL HAVELESS THAN 3% VOLTAGE DROP.f. EQUIPMENT SHOWN SCREENED IS EXISTING TO REMAIN.EQUIPMENT SHOWN DARK IS NEW TO BE REMOVED ORPROVIDED.PLAN KEY NOTES:1. EXISTING STAGE DIMMING PANEL IS TO BE REMOVED FORREPLACEMENT WITH NEW. CONDUIT AND CONDUCTORSMAY BE SALVAGED FOR REUSE.2. PROVIDE NEW MAIN BREAKER RELAY PANEL. MODIFYFEEDER AND BRANCH CONDUIT AND CONDUCTORS TOACCOMODATE THE NEW RELAY PANEL INSTALLATION.CA-00006208935 Lake Baldwin LaneOrlando, Fl. 32814Tel: 407-767-5188Fax: 407-767-5772www.sgmengineering.comCopyright © 2025 SGM Engineering, Inc.SGM #: 2024-379ENGINEERMARK A. ESCOTTDESIGNED BYDRAWN BYENGR OF RECORDISSUE DATE10/13/2025AE PROJECT NUMBER2024-379SHEET TITLEELECTRICAL ONE LINEDIAGRAMSDRAWING NO.E501
- Commodity Codes
-
- NAICS 238210Electrical Contractors and Other Wiring Installation Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Carlin Park - Pickleball Cour...
Description: Carlin Park - Pickleball Court Lighting Department: Facilities Dev & Ops Buyer:
Palm Beach County
Bid Due: 11/22/2029
City of Doral Holiday Lightin...
Project ID: Title: City of Doral Holiday Lighting & Decor Addenda: 0 Release
City of Doral
Bid Due: 7/06/2026