Bunten Road Park Improvement Project
Project Information
- Bid Title
- Bunten Road Park Improvement Project
- Issuing Agency
- City of Duluth
- Location
- Georgia
- Published Date
- Dec 23, 2025
- Closing Date
- Jan 22, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Description Opening Date/Time Closing Date/Time
Bunten Road Park Improvement Project
Architectural Plans
December 10, 2025
:
January 22, 2026
11:00
AM
- Attachment Preview
-
BUNTEN ROAD PARKIMPROVEMENT PROJECT3180 BUNTEN ROADDULUTH, GA 30096VICINITY MAPSITEAREA MAPGWINNETT COUNTY FIRE MARSHAL INSPECTIONS ARE TO BE SCHEDULED ONLINE AT:GwinnettZIP.com-50% = Inspections of vertical penetrations.-80% = Inspections of any fire rated partitions, floor or ceiling, ceiling cover up.-100% = Final inspection, all systems and equipment are installed and operational,Any inspection requests made after 2:00 pm will be scheduled for the next business day.SEPARATE SUBMITTALS AND REVIEWS BY FIRE PLAN REVIEW FOR:__ Fire Sprinkler__ Fire Alarm Systems__ Kitchen Hoods__ Fire Suppression Systems__ Rack Storage (Product height over 12 feet)__ Storage and/or use of Hazardous Materials1. SIGNS ARE NOT APPROVED WITHIN THE SCOPE OF THIS BUILDING PERMIT. A SEPARATE SIGNLOCATION PERMIT IS REQUIRED FOR EACH SIGN2. SMOKING IS PROHIBITED IN ALL ENCLOSED PUBLIC PLACES AND IN ALL ENCLOSED AREAS WITHINPLACES OF EMPLOYMENT IN ACCORDANCE WITH COUNTY CLEAN INDOOR AIR ORDINANCE.REVISION HISTORYNO.DATEDESCRIPTION1 10/16/2025COUNTYCOMMENTSSHEETSG-001, A-101DRAWING INDEXSHEET NUMBERGENERALSHEET NAMEG-001G-002ARCHITECTURAL COVER SHEETGENERAL NOTESARCHITECTURALSHEET NUMBERSHEET NAMED-101EXISTING CONDITIONS & DEMOLITION FLOOR PLANSA-101NEW FLOOR PLAN, WALL SECTION, SCHEDULES &DETAILSSCOPE OF WORKADDITION OF CONCRETE BLOCK PRIVACY WALLS AROUND RESTROOM ENTRANCE DOORS, RELOCATION OF WOMEN'SRESTROOM ENTRANCE DOOR.SITEBLDGJURISDICTIONBUILDING REVIEW:CTIYOFDULUTH3167 MAIN STREETDULUTH, GEORGIA 30096PH: 770.476.3434FIRE PLAN REVIEW:GWNINETTCOUNTYDEPOT.FPLANNNIG&DEVELOPMENTFIRE PLAN REVIEWONE JUSTICE SQUARE446 WEST CROGAN STREET, SUITE 150LAWRENCEVILLE, GEORGIA 30046PH: 678.518.6000 FAX: 678.518.6144CODES/STANDARDS & CLASSIFICATIONS2018 INTERNATIONAL BUILDING CODE, WITH 2020 GEORGIA STATE AMENDMENTS2018 INTERNATIONAL MECHANICAL CODE, WITH 2020 GEORGIA STATE AMENDMENTS2018 INTERNATIONAL FUEL GAS CODE, WITH 2020 GEORGIA STATE AMENDMENTS2018 INTERNATIONAL PLUMBING CODE, WITH 2020 GEORGIA STATE AMENDMENTS2020 NFPA NATIONAL ELECTRIC CODE2018 INTERNATIONAL FIRE CODE, WITH LATEST STATE AMENDMENTS2010 ADA STANDARDS FOR ACCESSIBLE DESIGNNFPA 101, LIFE SAFETY CODE 2024 EDITION. (AMENDED BY 120-3-3) 12015 INTERNATIONAL ENERGY CONSERVATION CODE , WITH 2020 GEORGIA STATE AMENDMENTS2018 INTERNATIONAL EXISTING BUILDING CODE WITH 2015 GEORGIA STATE AMENDMENTS2015 GWINNETT COUNTY CONSTRUCTION CODE2012 GWINNETT COUNTY ORDINANCE FOR FIRE PROTECTION AND LIFE SAFETYCURRENT EDITION OF THE NFPA CODES AND STANDARDS AS ADOPTED AND MODIFIED BY THE STATE FIRE MARSHALCURRENT ADOPTED OCGA 120-3-3 GEORGIA MINIMUM FIRE SAFETY STANDARDS 1PROJECT INFORMATIONNAME OF DEVELOPMENT:DEVELOPMENT LOCATION:BUNTEN ROAD PARK3180 BUNTEN ROAD DULUTH, GEORGIANAME OF OWNER:OWNER ADDRESS:CITY OF DULUTH3167 MAIN STREETDULUTH, GA 30096BUILDING AREA:NUMBER OF BUILDINGS:NUMBER OF STORIES:BLDG HGT PER CODE:OCCUPANCY CLASSIFICATION:CALCULATED LOAD FOR WATER CLOSETS:CALCULATED LOAD FOR LAVATORIES:OCCUPANCY LOAD CALCULATIONS:CONSTRUCTION TYPE:GROSS BUILDING AREA:348 SQUARE FEETONEONEEXISTING(U) UTILITY & MISCELLANEOUSEXISTINGEXISTINGN/AIIIB - NOT SPRINKLERED, NON-FIRE ALARMED348 SQUARE FEET10/16/20251COUNTY COMMENTSGENERAL NOTES:FIRE EXTINGUISHERS REQUIREDPORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPASTANDARD NO. 10. ABC. LOCATION AND ARRANGEMENT OF THE FIREEXTINGUISHERS WILL BE DETERMINED BY AN INSPECTOR OF THE FIREMARSHAL'S OFFICE PRIOR TO FINAL INSPECTION.FIRE EXTINGUISHERS IN BUSINESS & MERCANTILE OCCUPANCIES SHALLBE LOCATED PER REQUIREMENTS OF NFPA 10. THE SIZE SHALL BE AMINIMUM OF TYPE A 10 TW0 (2) ARE REQUIRED AND SHALL BE INSTALLEDAT A MAXIMUM OF 48" ABOVE THE FINISHED FLOOR TO THE TOP OF THEHANDLE.EGRESS LIGHTINGEMERGENCY EGRESS LIGHTING MUST PROVIDE A MINIMUM 1-FOOTCANDLE UNINTERRUPTED LIGHT SOURCE ALONG THE PATH OF EGRESS.IF LESS THAN 3 SEPARATE LIGHTING CIRCUITS ARE PROVIDED, DEDICATEDCIRCUITS FOR EMERGENCY LIGHTING ARE NOT PERMITTED. THEY SHALLBE CONNECTED TO THE LIGHTING CIRCUIT BREAKER THE AREA THEYSERVE. NFPA 70, CHAPTER 7, SECTION 700-12(E). DEDICATED CIRCUITSFOR EXIT LIGHTING ARE NOT PERMITTED. THEY SHALL BE CONNECTED TOTHE LIGHTING CIRCUIT BREAKER IN THE AREA THEY SERVE. NFPA 70,CHAPTER 7.LABELINGALL UTILITY METERS, DISCONNECT SWITCHES, FRONT & REAR DOORSMUST BE MARKED WITH CONTRASTING LETTERS & NUMBERS TO INDICATETHE TENANT SPACE THEY SERVE.EXIT LIGHTINGALL EXIT LIGHTS & EMERGENCY LIGHTS SHALL HAVE A MINIMUM 90MINUTE BATTERY LIFE.SMOKE DETECTORSANY HVAC EQUIPMENT PRODUCING MORE THAN 2000 CFM AIR VOLUMEMUST BE EQUIPPED WITH AN AUTOMATIC SMOKE DETECTOR WITHIN THEDUCTWORK THAT IS CAPABLE OF SHUTTING DOWN THE UNIT IN THEEVENT OF FIRE. SMOKE DETECTORS MUST BE WIRED TO A VISUALSTROBE, AS WELL AS PRODUCE AN AUDIBLE ALARM SO AS TO ALERT THEBUILDING OCCUPANTS OF FIRE OR SMOKE DETECTED.ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE CODES.COORDINATION OF ALL DISCIPLINES IS THE RESPONSIBILITY OF THEGENERAL CONTRACTOR. IF THE CONTRACTOR FINDS ANY DISCREPANCIESIN THE DOCUMENTS SUCH THAT MUST BE REPORTED IMMEDIATELY TOTHE ARCHITECT. TYPICALLY DOCUMENTS INCLUDE A SPECIFICATIONMANUAL. CONTRACTOR TO REVIEW THE SPECIFICATIONS FOR THEPROJECT.CONTRACTOR MUST FIELD VERIFY ALL DIMENSIONS AT PROJECT.CONTRACTOR SHOULD NOT SCALE OFF OF DRAWINGS. CONTRACTORNEEDS TO FIELD VERIFY EXISTING CONDITIONS TO CONFIRM DRAWINGSARE ACCURATE. IF THE CONTRACTOR FINDS DISCREPANCIES BETWEENFIELD CONDITIONS AND DOCUMENTS THE CONTRACTOR MUSTIMMEDIATELY CONTACT THE ARCHITECT.DOORS AND ACCESSIBILITY:CONTRACTOR SHALL FOLLOW THE U.S. DEPARTMENT OF JUSTICE, 2010AMERICANS WITH DISABILITIES ACT (A.D.A.) STANDARDS FOR ACCESSIBLEDESIGN. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CLEAR AREAS ANDANY A.D.A. REQUIREMENTS BEFORE BEGINNING WORK. CONTRACTORMUST IMMEDIATELY CONTACT THE ARCHITECT IF DISCREPANCIES AREFOUND.DOORS SHALL MEET THE REQUIREMENTS OF THE NFPA 101 LIFE SAFETYCODE, CHAPTER 7.THE FLOOR LEVEL SHALL BE THE SAME ON BOTH SIDES OF THE DOOR (NOMORE THAN 1/2" DROP). THE ELEVATION SHALL BE MAINTAINED FOR ADISTANCE AT LEAST EQUAL TO THE WIDTH OF THE WIDEST LEAF OF THEDOORS. NFPA 101 LIFE SAFETY CODE, CHAPTER 7.EXIT DOORS SHALL NOT BE SUBJECT TO THE USE OF A KEY OR REQUIRESPECIAL KNOWLEDGE TO OPERATE, NFPA 101 LIFE SAFETY CODE,CHAPTER 7, LATEST EDITION.DOORS/HARDWARE, HANDLES, PULLS, LATCHES, LOCKS, AND OTHEROPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THATIS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHTGRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE.LEVER-OPERATED MECHANISMS, PUSH-TYPE MECHANISMS, ANDU-SHAPED HANDLES ARE ACCEPTABLE DESIGNS. THESE TYPES SHALL BESUPPLIED PER THE ADA STANDARDS FOR ACCESSIBLE DESIGN. TO THEBEST OF OUR KNOWLEDGE THIS INFORMATION ON THESE DRAWINGSCOMPLY WITH ADA. CONTRACTOR MUST VERIFY BEFORE PURCHASE OFDEVICES.TYPICAL MINIMUM MANEUVERING CLEARANCES ON THE PULL SIDE OFDOOR SHALL BE A MINIMUM OF 18". PER THE ADA STANDARDS FORACCESSIBLE DESIGN. MINIMUM MANEUVERING CLEARANCES IN THE PUSHSIDE OF THE DOOR SHALL BE A MINIMUM OF 12" IF THE DOOR HAS ACLOSER AND A LATCH. PER THE ADA STANDARDS FOR ACCESSIBLEDESIGN. THE TOPS OF ACCESSIBLE TABLES AND COUNTERS SHALL BEFROM 28 INCHES TO 34 INCHES ABOVE THE FINISHED FLOOR OR GROUNDPER ADA STANDARDS FOR ACCESSIBLE DESIGN.DRINKING FOUNTAINS:IF APPLICABLE, WHERE ONLY ONE DRINKING FOUNTAIN IS PROVIDED ON AFLOOR, THERE SHALL BE A DRINKING FOUNTAIN WHICH IS ACCESSIBLE TOINDIVIDUALS WHO USE WHEEL CHAIRS IN ACCORDANCE WITH 2010 ADA,AND ONE ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING ORSTOOPING. THIS CAN BE ACCOMMODATED BY USE OF A "HI-LO"FOUNTAIN. ADVISORY 602.6 WATER FLOW. THE PURPOSE OF REQUIRINGTHE DRINKING FOUNTAIN SPOUT TO PRODUCE A FLOW OF WATER 4INCHES (100 MM) HIGH MINIMUM IS SO THAT A CUP CAN BE INSERTEDUNDER THE FLOW OF WATER TO PROVIDE A DRINK OF WATER FOR ANINDIVIDUAL WHO, BECAUSE OF A DISABILITY, WOULD OTHERWISE BEINCAPABLE OF USING THE DRINKING FOUNTAIN.GENERAL:ALL CONCEALED WOOD TO BE FIRE RETARDANT UNLESS IT MEETS WOODBLOCKING EXCEPTION IN CODE.CONTRACTOR SHALL INSTALL WOOD BLOCKING FOR ALL WALL HUNGDEVICES SUFFICIENT TO MEET LOCAL CODES.INSULATING MATERIALS INSTALLED IN BUILDING OF ANY TYPE OFCONSTRUCTION SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 450 ASDETERMINED IN ACCORDANCE WITH ASTM E84.SIGNAGE IS NOT PERMITTED WITH THESE DOCUMENTS. A SEPARATEPERMIT FOR SIGNS MUST BE SUBMITTED.ARCHITECTURAL ABBREVIATIONSPLEASE REFER TO ENGINEERING DRAWINGS FOR ENGINEERINGAABBREVIATIONS AFFMA.C.T.A.F.FA.H.UALT.ALUM.ANODAPPROX.ARCH.ASTMAUX.BB/B.F.F.BKBDBLDG.CC.I.P.C.J.C/LCLG.CLR.C.M.C.M.U.CNT.C.O.CONC.CONT.CPT.C.T.DDBL.DIA.DIV.DN.DR.D.S.DW.D.W.DWG.DWGS.EEAEF.ELEC.ELEV., ELE.M.S.E.P.D.MEQ.EQUIP.E.W.E.W.H.EX., EXIST.EXP.EXT.ACOUSTICAL CEILING TILEABOVE FINISH FLOORAIR HANDLING UNITALTERNATEALUMINUMANODIZEDAPPROXIMATELYARCHITECTURALAMERICAN SOCIETY FORTESTING MATERIALAUXILIARYBBOTTOM OFBOTTOM OF FINISH FLOORBACKBOARDBUILDINGCCAST IN PLACECONTROL JOINTCENTERLINECEILINGCLEARCOFFEE MAKERCONCRETE MASONRY UNITCOUNTERCASED OPENINGCONCRETECONTINUOUSCARPETCERAMIC TILEDDOUBLEDIAMETERDIVISIONDOWNDOORDOWNSPOUTDISHWASHERDOMESTIC WATERDRAWINGDRAWINGSEEACHEXHAUST FANELECTRIC, ELECTRICALELEVATIONENERGY MANAGEMENT SYSTEMETHYLENE PROPYLENEDIENE MONOMEREQUALEQUIPMENTEACH WAYELECTRIC WATER HEATEREXISTINGEXPANSIONEXTERIOR*FF.D.F.D.C.F.E.F.E.C.F.F.FT.F.V.F.R.T.FAHRENHEITFLOOR DRAINFIRE DEPARTMENT CONNECTORFIRE EXTINGUISHERFIRE EXTINGUISHERCABINETMAX.MECH.MFR.MICRO.MIN.MISC.FINISH FLOORMM.FEETM.O.FIELD VERIFYMTD.FIRE RETARDANT TREATEDMTL.GGGA.GALV.G.C.GAUGEGALVANIZEDGENERAL CONTRACTORGFCI.GROUND FAULTCURRENT INTERUPTERGLGLASS, GLAZINGG.W.B, GYP.BD. GYPSUM WALL BOARDNN/ANEG.N.F.W.H.N.I.S.NO.HHC.HDWR.HMHORIZ.HR.IID.I.M.IN.INCAND.INSUL.JJT.KK.KO.KWLLAM.LAV.LB.LF.L.S.D.HHANDICAPPEDHARDWAREHOLLOW METALHORIZONTALHOURIINSIDE DIMENSIONICE MAKERINCHESINCANDESCENTINSULATIONJJOINTKKIPKNOCK OUTKILOWATTLLAMINATELAVATORYPOUNDLINEAR FOOTLIQUID SOAP DISPENSEROO.A.O.C.O.D.O.H.OPNG.OPP.OPP. HDPP.A.PAR.PERP.PL.P. LAM.PLY. WD.PNL.POS.PREFAB.PREFIN.P.S.I.P.S.F.P.T.PVC.PVMT.Q-MMAXIMUMMECHANICALMANUFACTURERMICROWAVEMINIMUMMISCELLANEOUSMILLIMETERMASONRY OPENINGMOUNTEDMETALNNOT APPLICABLENEGATIVENON-FREEZE WALLHYDRANTNOT IN SCOPENUMBEROOVERALLON CENTEROUTSIDE DIMENSION OROUTSIDE DIAMETEROVERHEADOPENINGOPPOSITEOPPOSITE HANDPPUBLIC ADDRESSPARALLELPERPENDICULARPLATEPLASTIC LAMINATEPLYWOODPANELPOSITIVEPRE-FABRICATEDPRE-FINISHEDPOUND PER SQUARE INCHPOUND PER SQUARE FOOTPRESURE TREATEDPOLYVINYL CHLORIDEPAVEMENTQ-RR.R.D.REF.REINF.REQD.R.L.R.O.R.T.U.R.V.SSCH.SGL.SH. RODSHT.SIM.S.O.G.S.S.STD.STL.STRUCT.TT/CTECHTELTEMP.T.O.TR.TSTAT.TYP.UU.N.O.UTIL.VV.C.T.VEND.V.I.F.VERT.V.T.R.V.W.C.WW/W.C.W.H.WHSE.WP.W.R.W.W.F.MATERIAL INDEXRRADIUSROOF DRAINREFRIGERATORREINFORCE, REINFORCINGREQUIREDRAIN LEADERROUGH OPENINGROOF TOP UNITROOF VENTSSCHEDULESINGLESHOWER RODSHEETSIMILARSLAB ON GRADESTAINLESS STEELSTANDARDSTEELSTRUCTURE, STRUCTURALTTOP OF CURBTECHNICALTELEPHONETEMPERATURETOP OFTRANSITION STRIPTHERMOSTATTYPICALUUNLESS NOTED OTHERWISEUTILITYVVINYL COMPOSITION TILEVENDING MACHINEVERIFY IN FIELDVERTICALVENT THROUGH ROOFVINYL WALL COVERINGWWITHWATER CLOSET/WATER COOLERWATER HEATERWAREHOUSEWEATHER PROOFWATER RESISTANTWELDED WIRE FABRICFINISH RATINGSEARTHGRAVELGROUT ORSURFACECONCRETECAST-IN-PLACECONCRETECUT STONEWOOD -ROUGHWOOD - FINISHWOODBLOCKINGSTEELPLYWOODGYPSUMINSULATION - BATTOR LOOSERIGID INSULATIONEXTERIORINSULATIONFINISH SYSTEMBRICKMINIMUM WALL FINISHCLASS "M"MINIMUM ROOF FINISHCLASS USE GROUPEXITS &EXIT ACCESSPASSAGEWAYS CORRIDORSA or BA or BA or BA or BROOMSA or BA or BGENERAL LEGEND12AB4A10111' - 0" A1A1012AA101A13A101NAME101X-11' - 10 1/2"COLUMN LINE INDICATORFACE OF WALL INDICATORDETAIL INDICATORDETAIL NUMBERSHEET NUMBERDOOR NUMBER, REFERTO SCHEDULECEILING MATERIAL FINISHCEILING HEIGHTEXTERIOR ELEVATION INDICATORDETAIL NUMBERSHEET NUMBERINTERIOR ELEVATION INDICATORDETAIL NUMBERSHEET NUMBERWALL/PARTITION TYPEWINDOW TYPE,REFER TO SCHEDULEENLARGED PLAN/DETAIL INDICATORDETAIL NUMBERSHEET NUMBERROOM NAME AND NUMBEREXTERIOR FINISH MATERIALDIMENSION LINENOTE: DIMENSIONS ARE TAKEN FROM FINISHEDFACE UNLESS OTHERWISE NOTED.NEW OPENING INSOFFIT FOR NEWLIGHT FXTUREEXISTING LIGHTTO REMAINEXISTING LIGHTTO REMAINEXISTINGLIGHTS TOREMAINNEW OPENING INSOFFIT FOR NEWLIGHT FIXTUREEXISTINGLIGHTS TOREMAINEXISTING LIGHTTO REMAINEXISTING LIGHTEXISTING LIGHTEXISTINGLIGHTS TOREMAINEXISTINGLIGHTS TOREMAINEXISTING LIGHTEXISTINGLIGHTS TOREMAINEXISTINGLIGHTS TOREMAINEXISTING LIGHTTO REMAINEXISTING ROOFOVERHANG TOREMAIN4 DEMOLITION REFLECTED CEILING PLAND-101 SCALE: 1/4" = 1'-0"EXISTING LIGHTEXISTING ROOFOVERHANG2 EXISTING CONDITONS REFLECTED CEILING PLAND-101 SCALE: 1/4" = 1'-0"6" BLOCK WALLREMOVE EXISTINGASPHALT FOR NEWFOOTING5D-101RETROFIT LINTEL DETAILSCALE: N.T.S.NOTE:1) ALL PLATES AND ANGLES TO RECEIVE(2) COATS PAINTEXISTING TELEPHONE CABINETTO BE REMOVED; CONTRACTORTO PATCH AND REPAIR BLOCKONCE TELEPHONE CABINET ISREMOVEDEXISTINGSIDEWALK TOBE REMOVEDMENRESTROOM12'-4" X 6'-7"REFER TO CIVIL DWGS FORADDITONAL INFORMATIONTELEPHONE CONDUIT TO BEREMOVED AND CUT OFF ATSOFFIT; CONTRACTOR TOPATCH AND REPAIR SOFFITEXISTING HOSEBIBB TO REMAIN3'-4" 8"WOMENRESTROOM12'-4" X 6'-7"REMOVE EXISTINGBLOCK FOR NEWMASONRY OPENINGHM DOOR, TYP.8" CONCRETEBLOCK WALL TYP.TELEPHONEDRYERDRYERWOMENRESTROOMMENRESTROOM5'-0"5'-0"1'-7" 1'-5" 4'-4"ELETRICALMETEREXISTINGELETRICAL PANEL5'-8"6'-0"8" CONCRETEBLOCK WALL TYP.5'-8"EXISTINGSIDEWALK TOREMAIN3 DEMOLITION FLOOR PLAND-101 SCALE: 1/4" = 1'-0"8'-0"3'-4"M.O.18'-8"7'-4"EXISTINGSIDEWALKEXISTING ROOFOVERHANG1D-101EXISTING CONDITIONS FLOOR PLANSCALE: 1/4" = 1'-0"GC TO FIELD VERIFY DIMENSIONS MATCH PLAN.CONTACT ARCHITECT IF DIMENSIONS ARE DIFFERENT.NEW TOP OF 4" SLAB TOBE FLUSH WITH EXISTING6X6 - W1.4 X W1.4 WWFNEW 15 MIL VAPORBARRIER ANDGRANULAR BASE------X------X------X------X------X---#4 x 1'-0" @ 24" O.C. DRILL 6"INTO EXISTING SLABCONT. MTL DRIP EDGENOTES:1. G.C. TO REMOVE PORTION OF EXISTINGWALL TO INSTALL NEW DOORS. G.C. MUSTSHORE UP BLOCK PER OSHA STANDARDSAND INSTALL STL ANGLE PER STRUCT DWGS.2. G.C. TO VERIFY NEW INSTALLATION IS WATERTIGHT AND FLASHED PER MANUF.RECOMMENDATIONS.EXISTING CONCRETEBLOCK WALL TO BEPAINTEDPAINTED STEEL PLATE -REFER TO STRUCTURAL DWGS.CONT. SEALANT BOTHSIDES ALONGPERIMETER OF FRAMENEW HOLLOW METAL FRAMEEXISTINGLIGHTNEW DOWNLIGHT;REFER TO RCPLEGENDEXISTING GRADENEW COMPACTED EARTH6 NEW SLAB CONNECTION DETAILA-101 SCALE: 1" = 1'-0"EXTERIOR5 HEAD DETAILA-101 SCALE: 1-1/2" = 1'-0"INTERIORCONCRETE NOTES:1) ALL CONCRETE WORK INCLUDING FORMING, REINFORCING, MIXING, PLACING ANDCURING SHALL BE DONE IN ACCORDANCE WITH THE ACI MANUAL OF CONCRETEPRACTICE INCLUDING 'BUILDING CODE REQUIREMENTS FOR CONCRETE'. ACI 301,LATEST EDITIONS.2) ALL CONCRETE SHALL ATTAIN A MINIMUM 28 DAY COMPRESSIVE STRENGTH OFf'c = 3,000 PSI FOR FOUNDATIONS, FOOTINGS AND STEM WALLS.f'c = 4,000 PSI FOR SLABS, PIERS, COLUMNS AND BEAMS.3) MIX DESIGNS SHALL BE IN ACCORDANCE WITH METHOD 1 OR METHOD 2 OF ACI 301-05.4) ALL CONCRETE SHALL HAVE A MAXIMUM WATER-CEMENT RATIO OF 0.505) CONCRETE SHALL ARRIVE AT THE JOBSITE WITH A SLUMP OF 3" TO 5".6) CONCRETE SHALL BE VIBRATED INTO FORMS WHILE PLACING WITHOUTOVER-VIBRATING. REINFORCING SHALL HAVE MINIMUM CONCRETE COVER OF -CONCRETE EXPOSED TO SOIL = 3"CONCRETE EXPOSED TO AIR = 2"7) CONCRETE TEST REPORTS SHALL BE MADE AVAILABLE TO JOB SITE FOR REVIEW BYINSPECTOR.8) DESIGN OF CONCRETE STRUCTURAL ELEMENTS INCLUDING WALLS, FORMED SLABS,BEAMS AND COLUMNS IS IN ACCORDANCE WITH ACI 318-14.9) PLACE A 15 MIL POLYETHYLENE MOISTURE BARRIER (WITH JOINTS LAPPED NOT LESSTHAN 6 INCHES) DIRECTLY BENEATH ALL INTERIOR CONCRETE SLABS OR GRADES.EXTERIOR4A-101EXISTING ROOFJOINTS IN CONCRETE NOTES:1) CONSTRUCTION AND/OR CONTROL JOINTS SHALL BE MADE AS DETAILED ON THEDRAWINGS. SAW-CUT CONTROL JOINTS SHALL BE INSTALLED WITHIN 12 HOURS OFCONCRETE PLACEMENT.2) CONSTRUCTION AND/OR CONTROL JOINTS FOR SLAB-ON-GRADE CONSTRUCTIONSHALL BE LOCATED ON COLUMN LINES.EXISTING FASCIA ANDSOFFIT TO BE PAINTED8" BOND BEAMWITH (1) #5 CONT.SLOPE4" CAP BLOCK8" (NOM) CONCRETESPLIT FACE BLOCKWALL, GROUT FILLEVERY@ 24" O.C. PERREBAR LOCATIONNEW HOLLOW METALDOOR & FRAME TO BEPAINTEDWALL BEYONDHOLLOW METAL DOORWEATHER STRIPALUM. THRESHOLDFINISH FLOORINTERIORSECURE TO SLAB PERMANUFACTURER'SINSTRUCTIONSDTL. AT METALTHRESHOLDSCALE: 3" = 1'-0"5A-101#5 AT 24" O.C.EXTERIORRESTROOMSOLID GROUTFILL, TYP.NEW CONCRETE,REFER TO CIVIL DWGS.NOTE:MINIMUM CONCRETECOVER FOR ALLF.F.E.0' - 0"REINFORCING = 3"#5 AT 24" O.C.#5 REBAR AT 24" O.C.DOWELS AT VERT. BARS.FILL CELLS AT ANCHORS(6) #5 CONT.(2) COATS ELASTOMERIC PAINT,REFER TO FINISH SCHEDULE ONA-102 FOR COLORDOOR THRESHOLDEXPANSION JOINTCONCRETE PAD, SLOPEAWAY FROM BUILDINGNEW 4,000 PSI 4"CONCRETE SLAB WITHWWF, REFER TO 6/A-1014A-101EXISTING CONC. SLABAND TURNDOWN3'-0"2A-101COMPACTED SUBGRADE PERGEOTECHNICAL REPORTWALL SECTIONSCALE: 3/4" = 1'-0"NEW DOWNLIGHT;REFER TO RCP LEGENDEXISTING LIGHTREFLECTED CEILING PLAN LEGENDSYMBOLDESCRIPTIONLIGHTOLIER BY SIGNIFY; FD 6R 11 Z10 SCT U WNOTES:EXISTING BRANCH CIRCUIT SERVING EXISTING DOWNLIGHTS TO BE DEMOLISHEDAND REUSED AND EXTENDED TO SERVE NEW DOWNLIGHT LUMINARIES.PROVIDE NEW CONDUIT AND WIRE AS REQUIRED. NEW CONDUIT AND WIRE TOMATCH EXISTING.TOTAL LOAD OF NEW LUMINARIES IS FIELD-SELECTABLE.G.C.TO SET CCT SWITCH TO MATCH NEARBY EXTERIOR AND SITE LUMINARIES.EXISTINGLIGHTS, NISEXISTINGLIGHTS, NISEXISTINGLIGHTS, NISEXISTING LIGHT3 REFLECTED CEILING PLANA-101 SCALE: 1/4" = 1'-0"NEW 8" CONCRETEBLOCK WALL, MATCHEXISTINGMEN'SRESTROOMSIGNNEW CONCRETESIDEWALK, REFERTO CIVIL DWGS5'-4"MEN'SRESTROOMSIGNMENRESTROOMEX2EXISTING TO REMAINEXISTINGURINAL TOREMAIN1WOMEN'SRESTROOMSIGN2A-1016'-8"1WOMENRESTROOMEXISTING TO REMAINNEW 8" CONCRETEBLOCK WALL, MATCHEXISTINGWOMEN'SRESTROOMSIGN6A-101INFILL DOOR OPENINGWITH NEW BLOCK TOMATCH EXISTING. GETBLOCKMANUFACTURER &TYPE FROM CITY.NEWSAFETYMIRRORNEW CONCRETESIDEWALK, REFERTO CIVIL DWGS6A-101EX11A-101NEW KEY ACCESS FOB; CONTRACTOR TORUN POWER TO DOOR STRIKE AND NEWKEY FOB, REFER TO SHEET A-102 FORSPECIFICSNEW FLOOR PLANSCALE: 1/4" = 1'-0"10/16/2025 1 COUNTY COMMENTSEXISTING LIGHT12"A MEN'S DOOR MOUNTED SIGNAGENTS6"MEN'SRESTROOMB MEN'S WALL MOUNTED SIGNAGENTS9" MIN.CENTER TACTILE CHAR.EQ. EQ.LATCH SIDEMEN'SRESTROOMVERTICAL DIMENSIONS FROM TOPOF FINISHED FLOORC TYPICAL DIMENSIONSNTS12"D WOMEN'S DOOR MOUNTED SIGNAGENTS6"9" MIN.CENTER TACTILE CHAR.EQ. EQ.LATCH SIDEWOMEN'SRESTROOMWOMEN'SRESTROOME WOMEN'S WALL MOUNTED SIGNAGENTSVERTICAL DIMENSIONS FROM TOPOF FINISHED FLOORF TYPICAL DIMENSIONSNTSSIGNAGE NOTES:1. SIGNS PROVIDED BY G.C. TO COMPLY WITH CA TITLE 24 REQUIREMENTS FOR ADA SIGNAGE AND WILL BEUSED IN ALL STORES. SIGNS TO INSTALLED BY G.C.COMPLIANCE SIGNS.COM ADA RESTROOM: RRE-120_DCTS_WHTONCHGRY PAIRED SET, SIZE: 12" CIRCLE / 9"H X6"W. WHITE LETTERS ON CHARCOAL GRAY BACKGROUND2. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLEDON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCHSIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENTWALL. TACTILE CHARACTERS SHALL BE MOUNTED 48" MINIMUM TO BASELINE OF LOWEST TACTILE CHARACTERAND 60" MAXIMUM TO BASELINE OF HIGHEST TACTILE CHARACTER. A CLEAR FLOOR SPACE OF 18" BY 18"MINIMUM CENTERED ON TACTILE CHARACTERS SHALL BE PROVIDED BEYOND THE ARC OF THE DOOR SWING.3. RESTROOM DOOR SYMBOL SHALL BE IN CONTRASTING COLOR.2 RESTROOM ADA SIGNAGEA-102 SCALE: NTSMARKDESCRIPTION1EXTERIOR DOOREXTERIOR DOOREXTERIOR DOORDOORTYPEAEXEXSIZE3'-0" x 7'-0"EXEXTHICKNESS MATERIAL0' - 1 3/4"EXEXHOLLOW METALEXEXDOOR SCHEDULEFINISHFRAMETYPEFRAMEMATERIALFRAME FINISHPAINTEXEX1HOLLOW METALEXEXEXEXPAINTEXEXHEADDETAIL3/A-102--JAMBDETAIL---THRESHOLD2/A-102--HARDWARE RATINGSET-1N/ASET-2N/AEXN/ADOORSCHEDULENOTES1, 2, 3,4-DOOR SCHEDULE NOTES:1. THRESHOLDS SHALL BE NO HIGHER THAN 1/2" AFF, EDGE TO BE BEVELED WITH A SLOPE NO GREATER THAN 1 IN 2.2. ALONG ACCESSIBLE PATH OF TRAVEL AND AT EGRESS CONDITIONS, DOOR HARDWARE SHALL BE OF THE LEVER ORPUSH TYPE, MOUNTED 30" TO 44" AFF AND OPERABLE WITH A MAXIMUM EFFORT OF 5 LB. FOR INTERIOR DOORS & 8.5LB. FOR EXTERIOR DOORS.3. PROVIDE 18" CLEAR SPACE ON STRIKE/PULL SIDE OF DOORS. PROVIDE 12" CLEAR SPACE ON STRIKE/PUSH SIDE OFDOORS WITH LATCHES AND/OR CLOSERS.4. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR SPECIAL KNOWLEDGE OREFFORT.EXTERIOR FINISH SCHEDULECATEGORYDESCRIPTION/FINISHNEW SPLIT FACE BLOCK & EXISTING SPLIT FACE BLCOK(2) COATS OF ELASTOMERIC PAINT: COLOR TO BE DETERMINEDDOORS & FRAMINGTOUCH UP EXISTING PAINT AS NEEDED AFTER CONSTRUCTION;CONTRACTOR TO GET PAINT COLOR FROM CITYROOF FASCIA & SOFFITTOUCH UP EXISTING PAINT AS NEEDED AFTER CONSTRUCTION;CONTRACTOR TO GET PAINT COLOR FROM CITYNOTES:1) CONTRACTOR TO PAINT INTERIOR OF DOORS. COLOR SW 7015 REPOSE GREY.2) CONTRACTOR TO PAINT SWATCHES ON EXISTING SPLIT FACE BLOCK WITH TWO COLORS; SW 7015 REPOSE GREY, AND SW 7065 ARGOS.CITY TO SELECT FINAL COLOR AFTER REVIEWHARDWARE SCHEDULESET #1 1 1/2 PAIR 4 1/2” X 4 1/2” US26D BUTT HINGESCAL ROYAL OR EQ. KEYED DEADBOLTCAL ROYAL OR EQ. PUSH/PULL PLATELATCH GUARDRUBBER DOOR SILENCERSLCN 4030 SERIES CLOSER OR EQUALWEATHER STRIP & THRESHOLDDRIP CAPSET #21 1/2 PAIR 4 1/2” X 4 1/2” US26D BUTT HINGESCAL ROYAL OR EQ. LEVER LOCK SET (US26D FINISH)SURFACE MOUNTED CLOSURERUBBER DOOR SILENCERKICK DOWN DOOR HOLDER (US26D FINISH)WALL MOUNTED DOOR STOP (US26D FINISH)1, RCI, Model 1300 03P-LTD Electronic Lock1, RCI, Model 4 Series Commercial Duty Electronic Strike1, RCI, Model 9321 Electronic Card ReaderSEE ELECTROMAGNETIC LOCK NOTENOTE:ELECTROMAGNETIC LOCKSElectromagnetic Locks: BHMA A156.23; electricallypowered; with electromagnet attached to frame andarmature plate attached to door; full-exterior or full-interiortype, as required by application indicated.Manufacturers: Subject to compliance with requirements,provide products by one of the following:a. Dortronics Systems, Inc.b. DynaLock Corp.c. Schlage Commercial Lock Division; anIngersoll-Rand company.d. Securitron Magnalock Corporation; an ASSAABLOY Group company.AUXILIARY ELECTRIFIED DOOR HARDWAREManufacturers: Subject to compliance with requirements,provide products by one of the following:1. DynaLock Corp.2. GE Security, Inc.3. SARGENT Manufacturing Company; an ASSAABLOY Group company.4. Schlage Commercial Lock Division; anIngersoll-Rand company.5. Securitron Magnalock Corporation; an ASSAABLOY Group company.6. Security Door Controls.Boxed Power Supplies: Locate power supplies asindicated or, if not indicated, in electrical equipment room.Verify location with Architect.Configuration: Provide least number of power suppliesrequired to adequately serve doors with electrified doorhardware.PER SCHEDULE2"FINSHEDFLOOR1 FRAME AND DOOR TYPESA-102 SCALE:1/4" = 1'-0"
- Commodity Codes
-
- NAICS 237310Highway, Street, and Bridge Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
26-272 Deans Bridge Road MSW ...
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-72155-NONST-2026-000000194
State Government of Georgia
Bid Due: 8/06/2026
160-172 Dalrymple Road Stormw...
Project: 160-172 Dalrymple Road Stormwater Improvement Ref. #: 26-053 Type: ITB Status: Open
City of Sandy Springs
Bid Due: 7/07/2026