Inductively Coupled Plasma - Optical Emission Spectrometry
Project Information
- Bid Title
- Inductively Coupled Plasma - Optical Emission Spectrometry
- Issuing Agency
- DEPT OF DEFENSE
- Location
- Illinois
- Published Date
- Oct 1, 2026
- Closing Date
- Oct 9, 2026
- Government Level
- Federal
- Status
- Closed
- Ref. #
- W911S227U0002
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Set Aside
- Total Small Business Set-Aside (FAR 19.5)
- Project Description
-
FollowInductively Coupled Plasma - Optical Emission SpectrometryActiveContract OpportunityNotice IDW911S227U0002Related NoticeDepartment/Ind. AgencyDEPT OF DEFENSESub-tierDEPT OF THE ARMYMajor CommandAMCSub CommandACCSub Command 2MISSION INSTALLATION CONTRACTING COMMANDSub Command 3419TH CSBOfficeW6QM MICC-FT DRUMGeneral InformationLooking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Oct 01, 2026 02:27 pm CDT
- Original Date Offers Due: Oct 09, 2026 12:55 am CDT
- Inactive Policy: Manual
- Original Inactive Date: Oct 01, 2027
-
Initiative:
- None
Classification- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 6630 - CHEMICAL ANALYSIS INSTRUMENTS
-
NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
-
Place of Performance:
2744 Rodman Ave. Rock Island, Illinois 61299
DescriptionMANDATORY MINIMUM REQUIREMENTS: Preferred instrument: ICP- OES comparable to the Agilent 5800; vendors may offer any equivalent system that meets the required specifications.1. Spectrometer RequirementsSimultaneous reading ICP OES w/ solid state detector.Bench top design only. Floor mount not acceptable.Echelle polychromator, 253 mm focal length, single detector, single entrance slit. Resolution: less than 0.0065 nm @ 200 nm; less than 0.013 nm @ 327.4 nm.Purged + thermostated optical enclosure; purge 0.7 L/min w/ 3 L/min boost option (less than 189 nm).Pixel level anti blooming detector.Vertical plasma; single piece torch. Optional torches must be available.View equal to or greater than 96% emission spectrum from 167-785 nm.Simultaneous UV + Vis determinations in one measurement.2. ICP System RequirementsBench top system; dual view vertical plasma (synchronous axial/radial).Must run aqueous + organic matrices including oil, MIBK, kerosene, hexanes.Monitors gas pressures/flows, water flows, air pressure, exhaust, plasma stability; auto shutdown on interlock breach.Operates at 15-30 degrees C and 25-80% RH; tolerates 2 degrees C/hr change with no performance loss.Exhaust requirement: equal to or greater than 2.5 m^3/min (88 ft^3/min).Power: equal to or less than 2.9 kVA, 200-240 VAC, 50-60 Hz, equal to or less than 15 amps3. Detector RequirementsSingle solid state detector; simultaneous reading of all wavelengths.Peltier cooled to equal to or less than -40 degrees C; Adaptive Integration capability.Hermetically sealed; no gas purge required.4. RF Generator RequirementsSolid state generator, 750-1500 W, 10 W increments.equal to or greater than 75% power transfer efficiency; typical stability 0.1%.5. Gas Flow ControlsAll plasma gases (coolant, auxiliary, nebulizer, makeup) must use mass flow controllers.Must meet flow ranges + increments listed in Government technical criteria.Integrated, computer controlled oxygen addition for organics.6. Sample Introduction SystemCassette style vertical torch; no manual adjustments required after mounting.Double pass glass cyclonic spray chamber + glass concentric nebulizer.Five channel variable speed peristaltic pump; up to 80 rpm.7. Software Requirements64 bit software; Windows 11 compatible.Automated background + spectral interference correction; automatic IEC recalculation.QC system supporting blanks, spikes, duplicates, and corrective actions.Full raw data saving + complete post run reprocessing.8. Performance RequirementsMust meet all EPA ICP OES detection limits and CRDLs using concentric nebulizer + cyclonic spray chamber.9. Additional RequirementsNew instrument; refurbished/demo units not acceptable.One year warranty (parts, labor, travel).Separate, remotely placeable water chiller.Autosampler holding equal to or greater than 180 sample positions + equal to or greater than 11 standards10. Hydrofluoric Acid Compatibility RequirementSample introduction systems must be or include compatible hardware for hydrofluoric acid use. This shall include, at a minimum, an HF-resistant nebulizer and spray chamber11. Certified Metal Standards Accuracy RequirementThe instrument shall be capable of analyzing within +/- 10% of certified values of metal standards (either chip or atomized metal powder) for typical alloy steel grades, typical stainless steel grades, typical copper alloys, typical cast and wrought aluminum, and titanium alloys with proper preparation for metallurgical elements excluding elements atypical of interrogation by ICP-OES methods such as carbon, nitrogen, hydrogen, and oxygen.Attachments/LinksContact InformationHistoryContracting Office Address- MICC FORT DRUM 4205 PO VALLEY RD
- FORT DRUM , NY 13602-5220
- USA
Primary Point of Contact- Alec Pirolli
- alec.l.pirolli.civ@army.mil
- Phone Number 5206929834
Secondary Point of Contact
- Oct 01, 2026 02:27 pm CDTCombined Synopsis/Solicitation (Original)
- Commodity Codes
-
- FSC 66Instruments and Laboratory Equipment
- NAICS 334516Analytical Laboratory Instrument Manufacturing
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Follow 5W Pulse Tube CryoCooler Active Contract Opportunity Notice ID RFP_387931RLP Related Notice
ENERGY, DEPARTMENT OF
Bid Due: 10/28/2026
EM - LYNX II Digital Signal A...
Bid Solicitation # 27-588IEMA-DIVNU-B-54308 Bid Solicitation # 27-588IEMA-DIVNU-B-54308 Organization Name EMA - Emergency
State Government of Illinois
Bid Due: 10/21/2026