RFP for Bedford Township Fire Department Training Tower Repair & Maintenance
Project Information
- Bid Title
- RFP for Bedford Township Fire Department Training Tower Repair & Maintenance
- Issuing Agency
- Bedford township
- Location
- Michigan
- Published Date
- May 27, 2026
- Closing Date
- Jun 12, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
- RFP for Bedford Township Fire Department Training Tower Repair & Maintenance
- Attachment Preview
-
BEDFORD TOWNSHIP FIRE DEPARTMENTMay 26, 2026RE: REQUEST FOR SEALED BIDSFire Training Tower Repair and Maintenance ProjectThe Bedford Township Fire Department is soliciting sealed bids from qualified contractors for the repair,rehabilitation, and maintenance of the live fire training tower located at 8100 Jackman Road,Temperance, Michigan 48182.The project is based upon deficiencies and recommendations identified during a recent five-yearstructural and operational inspection completed by Rimkus Consulting Group in accordance with NFPA1400 requirements for live fire training structures. The inspection report dated May 8, 2026, is attachedand shall be considered part of these bid specifications.The training tower is a three-story live fire training structure containing two non-gas-fired burn roomsutilizing Westemp insulation panel systems. Contractors submitting proposals shall review the attachedinspection report in its entirety and provide a comprehensive proposal addressing all identified repairand maintenance items.At a minimum, all proposals shall include the following:• Detailed cost estimates for all recommended repairs and maintenance items• Estimated timeline for project completion following contract execution• Estimated lead times for procurement of materials and scheduling• Applicable warranty information for labor and materials• Contractor qualifications and documented experience with live fire training structures, burnbuildings, or similar specialized facilities• Identification of any subcontractors proposed for use on the project• Proof of appropriate licensing and insurance coverageAttention shall be given to the following HIGH-PRIORITY items, which must be completed before thestructure may be returned to service:• Removal and replacement of damaged, cracked, and failed Westemp insulation panels in bothburn rooms• Removal and replacement of the pyrometers and data logging system in both burn roomsAdditional medium- and low-priority deficiencies identified within the inspection report shall also beincluded in the proposal and separated by category and priority level.Contractors are encouraged to conduct a site visit prior to submission of bids. Site visits may bescheduled by contacting the Bedford Township Fire Department.All work shall comply with applicable NFPA standards, manufacturer specifications, OSHA regulations,state and local codes, and industry best practices for live fire training facilities.The Bedford Township Board reserves the right to reject any or all bids, waive informalities orirregularities in the bidding process, and accept the proposal deemed to be in the best interest of theTownship.Sealed bids shall be clearly marked:“SEALED BID – FIRE TRAINING TOWER REPAIRS”and delivered to:Bedford Township Clerk’s Department8100 Jackman Rd,Temperance, MI 48182Bids must be received no later than June 12, 2026, by 4:00 P.M.Bids will not be opened at the time of the deadline. Bids will be open at the discretion of the Clerk,when time allows. Results will be posted on the township website www.bedfordmi.comQuestions regarding this request may be directed to:Fire Chief Bob VanklingerenBedford Township Fire DepartmentPhone: 734-224-7312Email: Bvanklingeren@bedfordmi.orgThank you for your interest in this project. We appreciate your time and consideration and look forwardto reviewing your proposal.100 West Big Beaver Road, Suite 200Troy, MI 48084(941) 727-2600Report of FindingsFire Training Tower, 5-Year Tower Inspection8100 Jackman Road, Temperance, MIRimkus Matter No: 100336464Prepared For:Fire Facilities, Inc.314 Wilburn RoadSun Prairie, WI 53590Attention:Ms. Shelly MertigDigitally signed by: DERECK J HODSONDate: 2026.05.08 15:46:49 -06'00'Dereck J. Hodson, P.E.Engineering Number P.E. 6201313043Senior ConsultantCraig M. DudasCraig M. Dudas, R.S.Reserve Specialist #215Senior Practice Leader – Construction AdvisoryMay 8, 2026TABLE OF CONTENTSI. General Information/Scope of Services1II. Tower Description4III. Background Information5IV. Observations7• General Observations – Visual• Structural Observations – Visual• Non-Structural ObservationsV. Summary11VI. Basis of Report12VII. Attachments13A. PhotographsB. Service BulletinC. Paint and Care Maintenance ManualD. Curriculum VitaeMay 8, 2026Section IGENERAL INFORMATION/SCOPE OF SERVICESRimkus has conducted this visual structural evaluation to assess the structural integrityof the fire training tower and make recommendations. National Fire Protection Association(NFPA) 1400 (2026 Edition) Section 8.2 requires that the structural integrity of the live firetraining structure be evaluated and documented annually by the building owner, operator,or Authority Having Jurisdiction (AHJ). If visible structural defects are found, such as butnot limited to cracks, rust, spalls, or warps in structural floors, columns, beams, walls, ormetal panels, the owner/operator shall have a follow-up evaluation conducted by alicensed professional engineer with live fire training structure experience and expertise.Follow-up Inspection ProgramThe follow-up inspection program complies with NFPA 1400 section 8.2.1.1 and willinclude the following, if applicable:• Complete service carried out by a licensed professional engineer with live firetraining structure experience and expertise.• Visual inspection of the exposed areas of the foundation and slab.• Visual inspection of the exterior of the tower.• Visual inspection of all exposed structural elements.• Visual inspection of all thermal linings.• Visual inspection of all doors and window shutters, including hardware.• Visual inspection of stairs, ladders, and fire escapes.• Recommendations for repairs, maintenance, or improvements.• A formal report with photographs documenting the findings.Non-Gas-Fired/5-Year Inspection ProgramMay 8, 2026 | Rimkus Matter No. 1003364641
- Commodity Codes
-
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
- NAICS 811310Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
RFP for Herbicides, Tank Mixi...
Description: RFP for Herbicides, Tank Mixing, and Training Department: Transportation Buyer: TERRY HARRIS
State of Michigan
Bid Due: 7/15/2026
AI+ Industry Non-Credit Cours...
AI+ Industry Non-Credit Course Development RFP Event ID: 1241440 Event Type: RFP Published
Grand Valley State University
Bid Due: 7/06/2026