EOI - Mainframe Platform DR Modernization Program
Project Information
- Bid Title
- EOI - Mainframe Platform DR Modernization Program
- Issuing Agency
- Southeastern Pennsylvania Transportation Authority
- Location
- Pennsylvania
- Published Date
- Jan 22, 2026
- Closing Date
- Feb 16, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
EOI – Mainframe Platform DR Modernization Program
Item EOI Mainframe Platform DR Modernization ProgramDocumentsSEPTA is conducting an industry review to gain market insight with the potential for a future procurement solicitation the Mainframe Platform DR Modernization Program.
SEPTA requests that interested parties submit an EOI response document containing responses to the Authority’s questions and technical specification comments no later than 4:00 PM Friday February 16,
2026.SEPTA does not intend to hold discussions at this time; however, SEPTA may contact interested parties to schedule individual meetings with SEPTA’s staff either at our headquarters in Philadelphia or virtually via video conference.
Contact: Jim Coombs
Email: jcoombs@septa.org
Phone: 215-580-7190Category: ePS Bids/RFPs
Status: Open - Attachment Preview
-
January 22, 2026To Whom It May Concern:Subject: Expression of Interest – Mainframe Platform DR Modernization ProgramSEPTA is conducting an industry review to gain market insight with the potential for a futureprocurement solicitation the Mainframe Platform DR Modernization Program. See attached EOIdocument for the information/comments being sought.SEPTA requests that interested parties submit an EOI response document containing responses to theAuthority’s questions and technical specification comments no later than 4:00 PM Friday February 16,2026.SEPTA does not intend to hold discussions at this time; however, SEPTA may contact interested partiesto schedule individual meetings with SEPTA’s staff either at our headquarters in Philadelphia or virtuallyvia video conference.If your organization is interested in this project, please submit all documentation to me atjcoombs@septa.org.By participating in this EOI the Proposer is unconditionally agreeing to the following: (i) SEPTA will beauthorized to use any information submitted, referenced, or presented during this EOI including, but notlimited to a potential Scope of Services; (ii) SEPTA shall be authorized to reproduce, distribute, display,and create derivative works from any information received during this EOI; and (iii) SEPTA shall not beobligated to engage or otherwise compensate Proposer in any manner or for any reason for SEPTA’s useof any information and/or material submitted by Proposer during this EOI or information containedtherein, or any other right granted hereunder.Please note that this is not a vendor selection process. This letter must not be interpreted as an award of acontract or as a commitment to reimburse for any costs incurred in the preparation or participation of thisEOI.Thank you for your interest in the Authority.Sincerely,James CoombsDirector, Contract AdministrationSEPTA’s Procurement and Supply Chain ManagementSEPTA – Mainframe Hardware Disaster Recovery ModernizationExpression of Interest (EOI)1. PurposeThe Southeastern Pennsylvania Transportation Authority (SEPTA) is seeking Expressions of Interest from qualifiedfirms with demonstrated expertise in IBM mainframe disaster recovery, physical resiliency, and business continuityplanning. SEPTA operate a mission-critical IBM Z mainframe environment that supports core Finance, Payroll, andProcurement functions.The purpose of this EOI is to identify firms capable of delivering an end-to-end disaster recovery modernizationprogram, including sourcing a like-for-like secondary mainframe, identifying and onboarding a qualified off-site datacenter facility, implementing the solution, and aligning technical recovery capabilities with SEPTA’s businesscontinuity requirements.This EOI is issued for information-gathering purposes and will inform SEPTA’s development of a future competitivesolicitation.2. Current Environment Overview (As-Is)SEPTA’s current mainframe environment includes the following characteristics:• Platform: IBM z14 ZR1 (Model 3097) with two LPARs (one general-purpose processor and one specialtyprocessor).• Capacity & Utilization: Rated at approximately 1200 MIPS, with an effective soft cap of approximately 88MIPS; average workload utilization of approximately 35% CPU busy.• Physical Footprint & Power: Approximately 500 square feet including frame and power distribution units;maximum power draw of approximately 11 kW for a single frame.• Memory & Storage: 52 GB installed memory with no observed paging; approximately 7.6 TB of DASDstorage with low utilization; Luminex virtual tape system supporting backup and archival.• Network Connectivity: IBM OSA 10 Gb network interface with relatively low average daily throughput.3. Program ObjectivesThe objectives of the Mainframe Disaster Recovery Modernization Program are to:• Establish a fully operational physical disaster recovery capability for SEPTA’s IBM mainframeenvironment within the greater Philadelphia tri-state area.• Source and deploy a like-for-like secondary IBM Z platform capable of restoring from existing Luminexvirtual tape backups.• Identify and onboard a qualified off-site data center facility that meets SEPTA’s reliability, security, andoperational requirements.• Define and integrate Recovery Time Objectives (RTO), Recovery Point Objectives (RPO), and businesscontinuity requirements for Payroll and Procurement.• Implement a sustainable, testable, and auditable disaster recovery operating model.1|Page4. Scope of Interest / WorkstreamsSEPTA seeks firms capable of delivering services across the following four integrated workstreams.Workstream 1 – Mainframe Disaster Recovery Platform Sourcing• Assess SEPTA’s current production mainframe environment, including processing capacity, LPARconfiguration, memory, storage, and backup architecture.• Define requirements for a like-for-like IBM Z disaster recovery platform capable of supporting Finance,Payroll, and Procurement operations during a disaster event.• Recommend sourcing options (purchase or lease) aligned with SEPTA’s capacity profile, licensingconsiderations, and long-term operational needs.• Ensure compatibility with existing Luminex virtual tape backup and restore processes.Workstream 2 – Off-Site Facility Identification & Readiness PlanningSEPTA does not intend to remediate previously identified secondary facilities. This workstream will focus onidentifying, evaluating, and onboarding an off-site facility suitable for hosting a secondary IBM Z platform.Vendors shall:• Define detailed facility requirements informed by SEPTA’s as-is environment, including:o Space and floor loading requirements (minimum ~500 sq. ft., appropriate floor load ratings,service clearances).o Power requirements (redundant utility feeds, UPS, generator capacity sufficient to support ~11kW per frame).o Cooling and environmental controls are appropriate for IBM Z platforms.o Physical security and access controls.o Network connectivity requirements, including redundant, low-latency connectivity back toSEPTA’s primary site.• Identify and evaluate candidate commercial data centers, colocation providers, or managed disasterrecovery facilities.• Perform site due diligence and produce a comparative assessment of candidate facilities, including risks,constraints, and cost considerations.• Recommend a preferred off-site facility and develop a site readiness and implementation plan.Workstream 3 – Implementation & Enablement• Execute the approved disaster recovery solution, including:o Procurement and installation of the secondary mainframe platform.o Coordination with the selected off-site facility for space, power, cooling, and security readiness.o Network integration and validation of backup and restore processes.• Develop operational runbooks, access procedures, and disaster recovery activation workflows.• Support initial and periodic disaster recovery testing to validate operational readiness.2|PageWorkstream 4 – Business Continuity & Recovery Alignment• Engage SEPTA’s Finance, Payroll, and Procurement stakeholders to define and document:o Recovery Time Objectives (RTO)o Recovery Point Objectives (RPO)o Application recovery sequencing and dependencies• Align business recovery requirements with the physical and technical disaster recovery design.• Ensure business continuity requirements are embedded into the final disaster recovery architecture,testing strategy, and operating model.5. Vendor QualificationsInterested firms must demonstrate:• Proven experience delivering IBM mainframe disaster recovery solutions, including physical DRenvironments.• Experience sourcing, implementing, and operating IBM Z platforms in primary/secondary or DRconfigurations.• Expertise in data center and facility evaluation, including power, cooling, and network requirements formainframe workloads.• Experience integrating business continuity planning with technical disaster recovery solutions.• Ability to deliver structured programs in large, regulated public-sector or enterprise environments.6. Submission Details• Deadline: February 15, 2026• Format: PDF or Word document, maximum 15 pages• Contact: James Coombs• Subject Line:“EOI – Mainframe Disaster Recovery Modernization – [Firm Name]”Submissions should clearly describe the firm’s approach, methodology, relevant experience, and proposedengagement model across all four workstreams.7. Next StepsSEPTA will review all submissions and develop a shortlist of qualified firms. Selected firms may be invited to engagewith SEPTA stakeholders to further discuss their approach and demonstrate alignment with SEPTA’s technical andbusiness requirements.Information gathered through this EOI will inform SEPTA’s development of a formal competitive solicitation8. DisclaimerThis Expression of Interest is issued for information-gathering purposes only and does not oblige SEPTA to issue asolicitation or award a contract. SEPTA reserve the right to modify, cancel, or take no further action related to thisEOI at its sole discretion.3|Page
- Commodity Codes
-
- NAICS 541511Custom Computer Programming Services
- NAICS 541512Computer Systems Design Services
- NAICS 541519Other Computer Related Services
- NAICS 541611Administrative Management and General Management Consulting Services
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
RFP 2026-47 Document Conversi...
Project: RFP 2026-47 Document Conversion and File Scanning Ref. #: City of Allentown,
PennBid
Bid Due: 7/24/2026
Legal Enterprise Management/C...
Posted Date: 6/9/2026 Due Date: 7/7/2026 Negotiation Number: NG10827 Program Office: Office of
School District of Philadelphia
Bid Due: 7/07/2026