CANCELLED Request for Qualifications: ?26-25014A Structural Assessments at W.E. Hunt & Fire Station 1 Addendum 1
Project Information
- Bid Title
- CANCELLED Request for Qualifications: ?26-25014A Structural Assessments at W.E. Hunt & Fire Station 1 Addendum 1
- Issuing Agency
- Town of Holly Springs
- Location
- North Carolina
- Published Date
- Dec 31, 2025
- Closing Date
- Jan 28, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
CANCELLED Request for Qualifications: 26-25014A Structural Assessments at W.E. Hunt & Fire Station 1
-
Due Date: January 28, 2 p.m. via e-mail - Solicitation (for historical purposes only. Solicitation cancelled as of 12/31/2025.)
- Addendum 1
-
- Attachment Preview
-
TOWN OF HOLLY SPRINGS, NCREQUEST FOR QUALIFICATIONSRFQ 26-25014A Structural Assessments at W.E. Hunt& Fire Station 1Issue Date: December 29, 2025Due Date: January 28, 2026 by 2:00 p.m.____________________________________________________________________________________I. PURPOSEThe Town of Holly Springs is seeking Statements of Qualifications (SOQs) fromlicensed Structural Engineering firms to perform a structural assessment at both theTown of Holly Springs W.E. Hunt Recreation Center Gymnasium (301 Stinson Ave,Holly Springs, NC 27540) and Town of Holly Springs Fire Station 1 (700 Flint Point Lane,Holly Springs, NC 27540). All SOQs submitted in response to this RFQ shouldspecifically address the scope of work below as it relates to both buildings.II. SCOPE OF WORK1. The Town of Holly Springs W.E. Hunt Recreation Center Gymnasium301 Stinson Ave, Holly Springs, NC 27540Use: A community centered hub for health, recreation, and socialactivities.Status: Open to the public; Serves between 840-1,200 patrons on aweekly basis.Square Footage: 27,000 SF2. Town of Holly Springs Fire Station 1700 Flint Point Lane, Holly Springs, NC 27540Use: 24/7 operational base that houses fire staff, their equipment, andemergency vehicles.Status: Occupied and in-serviceThe selected firm will provide professional structural engineering services typical tostructural assessments of occupied, commercial buildingsAssessment should include, but is not limited to: Analysis of all existing structural systems to determine the condition,capacities, and limitations of the entire building or structure (not just selectiveanalysis of areas with obvious structural deficiencies); Assessment of the overall condition of various structural systems andcomponents throughout the facility using a facility condition index or similarmethod to provide a basis for analysis; Evaluation of the building’s foundation, framing, walls, columns, supports,beams, and other superstructure/structural /construction systems; Determination of the existing load bearing capacity for individual structuralcomponents; Identification of structural deficiencies that need to be addressed for anadaptive use;TOHS Project# 25-014 Structural Assessments at W.E. Hunt & Fire Station 1Page 1 of 10 Determination of the causes and extent of existing or potential structuralfailures; Assessment of the overall structural integrity of the building; Investigation of the soil bearing capacity, scour resistance, and buildingenvelope features; Assessment of the integrity, capacity, and function of the building’sstormwater conveyance system, gutters, and downpipes; A lifecycle evaluation of the building components and structural systems; Using the International Existing Building Code (IEBC) standards on structuralrenovation, identify thresholds that may trigger additional structural workduring major renovations (non-structural code areas such as accessibility,energy, egress, fire safety, etc. are excluded); Consideration of site history, prior building reports, and documentation ofprevious structural work performed; Consideration of local factors including geotechnical conditions, climate andenvironmental loads, surrounding infrastructure, surrounding land use, andregulatory requirements; Consideration of occupancy type/building use.Services should include, but are not limited to: Two site visits as described in section IV; A comprehensive structural report summarizing findings andrecommendations based on the scope of work; An in-person meeting with Town staff and management team to present anddiscuss findings and recommendations; A signed and sealed assessment of findings and recommendations deliveredto the Town of Holly Springs Chief Building Official.A structural report should include, but is not limited to the following: A comprehensive list of results and findings based on the scope of work; A thorough evaluation of current facility conditions and deficiencies; Photo documentation of all existing conditions (building systems,components, deficiencies, etc.); A comprehensive list of recommended corrective actions (remediationefforts, improvements, repairs, renovations, etc.) based on findings;(If applicable) Documentation and justification of the need for demolition; Estimated costs of recommendations and remediation efforts (includingarchitectural and engineering design, permit, and inspection fees) withconsideration for ROI; Estimated timeline and order that remediation, corrections, and renovationefforts should occur based on the lifecycle, stability, safety, and feasibility ofthe building and its components; Prioritization of all deficiencies on a scale of 1-5 based on the categorizationlevels below:TOHS Project# 25-014 Structural Assessments at W.E. Hunt & Fire Station 1Page 2 of 10PRIORITY12345TIMELINEDESCRIPTIONImmediateWithin 1 yrWithin2 – 3 yrsWithin3 – 5 yrsWithin5 – 10 yrs10+ yrs/OptionalCritical Condition: Deficiencies or issues that need immediateaction; conditions/deficiencies that pose an immediate threator risk to the health and safety of occupants; issues that poseimpending/imminent structural failure; critical breaches ofbuilding code that result in severe safety implications/legal riskPotentially Critical: Deficiencies or issues that are rapidlydeteriorating and need to be addressed to enhancestructural stability and reduce risk to the health and safety ofoccupants; if not corrected within 2-3 years, the issue couldpose a risk to the health and safety of occupants; issues that ifnot addressed, may lead to more extensive and costlydamage/remediation efforts.Necessary/Condition Deteriorating: Deficiencies or issueswhere routine/simple maintenance could delay furtherdeterioration and extend the life of structuralcomponents/systems; includes structural/building componentsthat have exceeded their useful life but still operate withconsiderable deterioration; if not corrected in 3-5 years, theissue could pose a risk to the health and safety of occupants.Functional Improvement Needed: Deficiencies or issues thathinder the proper functioning or performance of thestructure’s components/systems; these issues don’t affect thebuildings structural integrity/performance in the near term;includes issues that if corrected, would reduce long-termmaintenance costs; includes structural/building componentsthat have exceeded their useful life but still operate with littleto no deterioration;Recommended/Cosmetic Defects: Includes surfaceimperfections or finishing flaws that do not affect the structurebut impact aesthetics; efficiency improvements; ADAaccessibility upgrades; issues that require low-levelmaintenance to prolong the life of structuralcomponents/systems; includes issues that do not conform toexisting codes but were “grandfathered” in their condition.Once awarded, this contract shall occur in phases, as outlined below:Phase 1: Complete and provide a comprehensive structural assessment inclusiveof all fieldwork and data collection for the Town of Holly Springs W.E.Hunt Recreation Center Gymnasium and Fire Station 1 as defined in thescope of work section II.Phase 2: Develop recommendations for improvements, repairs, renovations,capital improvements, etc., based on the data collected in Phase I asdefined in the scope of work section II.Phase 3: Present all final written reports, supplemental data, and presentations tothe TOHS leadership and stakeholder groups as defined in the scope ofwork section II.TOHS Project# 25-014 Structural Assessments at W.E. Hunt & Fire Station 1Page 3 of 10Response times and availability for urgent assessments will be considered inevaluating qualifications.III. PROCUREMENT SCHEDULEThe following table shows the schedule of events for the conduct of this solicitation.Details for some of the events are described in subsequent sections. All dates aresubject to change.DATE / TIMEDecember 29th, 2025January 5th, 2026, at 2PMJanuary 5th, 2026, at 3:30PMJanuary 9th, 2026, by 5PMJanuary 14th, 2026January 28th, 2026 by 2PMJanuary 30th, 2026EVENTIssuance of SolicitationSite Visit at the Hunt Center (attendance optionalbut preferred)Site Visit at the Fire Station 1 (attendance optionalbut preferred)Deadline to Submit QuestionsTown to Post Answers to Questions (if any)Statement of Qualifications Submission DeadlineEvaluation begins with contract negotiations tofollowIV. SITE VISITAn optional site visit will be held on January 5th, 2026, at 2PM at the W.E. HuntRecreation Center at 301 Stinson Ave, Holly Springs, NC 27540 followed by anoptional site visit at Fire Station 1 on January 5th, 2026, at 3:30PM at 700 Flint PointLane, Holly Springs, NC 27540. This initial site visit will introduce the first project to betasked under this contract.If you plan to attend the site visit, please confirm with the assigned ProjectManager, Whitney Carr at least 48 hours before the scheduled visit:Whitney.Carr@hollyspringsnc.govV. STATEMENT OF QUALIFICATIONS SUBMISSION INSTRUCTIONSFormatResponses shall be submitted in a single, digital PDF file and contain the contentdescribed below. The file should be a maximum of 15 pages in length, not includingthe cover letter or authorized appendices detailed in the content section. Pleaseuse size 11 point or larger font for readability.ContentResponses must satisfy the criteria outlined below to be responsive to this solicitation.Any modifications or enhancements proposed beyond the identified scope of workoutlined in this document must be clearly identified.No work product, design, or costs/fees specific to this project may be submitted.Failure to meet the requirements listed in this section may deem the submission asnon-responsive and be removed from consideration.TOHS Project# 25-014 Structural Assessments at W.E. Hunt & Fire Station 1Page 4 of 101. Cover Letter [no more than one (1) page]Cover letters must include the following, at minimum: The legal name, address, and telephone number of the firm; The designated contact’s name, title, email address, and telephonenumber; The location in which the majority of the work will be executed andmanaged. Provide the same information for each subconsultant oreach member of a joint venture, if applicable; A brief description ofyour interest in this project and the unique advantages your firm/teambring to this project; A statement attesting to the submittal's accuracy; The signature of the individual(s) authorized to execute binding legaldocuments for the firm.2. Firm(s) Information and QualificationsDescribe your firm (and any subconsultant/subcontractor firms and/or relevantbusiness entities) and how it’s organized including but not limited to thefollowing: The business entity type All locations the work will be executed and managed; include thepercentage of work expected at each location (if applicable); The overall size/number of employees; The number of registered architects, engineers, and othertechnical/relevant staff; The year the business was established and the number of years inbusiness for each company/firm; The names and title of each person authorized to enter into a contractwith the Town; Services provided/areas of expertise; Describe any litigation or arbitration (closed in the last 5 years, active,and/or pending) in which your firm has been involved and the outcome;3. Qualifications and Experience of Relevant Personnel and ConsultantsIdentify all relevant personnel, subconsultants/subcontractors, and keystakeholders that will be assigned to the scope of work as described in section II.Describe their qualifications and experience including but not limited to thefollowing: Roles and expected responsibilities as it relates to the scope of work. For allsubconsultants/subcontractors, please include their percentage of work; An overview of the project team’s current capacity and how this projectwill fit into their workload; An organization chart of all key team members who will be directlyinvolved in this project, including any subcontractors, to be assignedspecifically to this project ** Organizational charts should be included inthe appendices and will not be counted against the page limitations; Resumes for each member of the project team that includes an overviewTOHS Project# 25-014 Structural Assessments at W.E. Hunt & Fire Station 1Page 5 of 10
- Commodity Codes
-
- NAICS 541330Engineering Services
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Progressive Design-Build Serv...
Project: Progressive Design-Build Services for Lee S. Dukes WTP Expansion Ref. #: FY27-DB-01
City of Charlotte
Bid Due: 9/03/2026
Replace Bridge No. 800239 on ...
Timeline EDB Timeline Rutherford No.239.pdf Doc. Type: 2026-05-15 09:29:39 Description: Express Design-Build Project
Division of Highways
Bid Due: 8/18/2026