Holmes Hospital Renovation
Project Information
- Bid Title
- Holmes Hospital Renovation
- Issuing Agency
- Ohio Facility Construction Commission
- Location
- Ohio
- Published Date
- Mar 20, 2026
- Closing Date
- Apr 21, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- UCN - 25181B
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Publish Date Due Date Number Owner Contractring Authority Project Name Primary Service Estimated Project Cost Q&A Short List Notes 2026/03/20 2026/04/21 UCN - 25181B University of Cincinnati Cincinnati/Hamilton Holmes Hospital Renovation C-A/E $105,000,000 N/A TBD - Attachment Preview
-
Request for Qualifications (Criteria Architect/Engineer*)State of Ohio Standard Forms and DocumentsAdministration of Project: Local Higher EducationProject Name Holmes Hospital Renovation200 Albert Sabin Way, Cincinnati, OHProject Location 45220City / County Cincinnati / HamiltonOwnerUniversity of CincinnatiDelivery Method Design-BuildNo. of paper copies requested (stapled, not bound)0Response Deadline 04/21/262:00 pm local timeProject NumberUCN - 25181BProject ManagerJustin JonesContracting Authority Local Higher EducationPrevailing Wages StateNo. of electronic copies requested (PDF)1* Criteria Architect/Engineer includes “any architect holding a certificate issued under section 4703.10 of the Revised Code,any landscape architect holding a certificate issued under section 4703.36 of the Revised Code, or any engineer holding acertificate issued under section 4733.14 of the Revised Code.” (Ohio Building Code section 4101:1-2-01 Definitions)Submit the requested number of Statements of Qualifications (Form F110-330) directly to Justin Jones atjonesju@ucmail.uc.edu. See Section J of this RFQ for additional submittal instructions.Submit all questions regarding this RFQ in writing to Justin Jones at jonesju@ucmail.uc.edu with the project numberincluded in the subject line (no phone calls please). Questions will be answered and posted to the Opportunities page on theOFCC website at http://ofcc.ohio.gov on a regular basis until one week before the response deadline. The name of the partysubmitting a question will not be included on the Q&A document.Project OverviewA. Project DescriptionThe University of Cincinnati is initiating the design and preconstruction phase of the Holmes Hospital Renovation as a firststep in relocating its College of Nursing. The Holmes Hospital Renovation represents a pivotal opportunity to advance themission of the University’s academic facilities for healthcare programs. With approximately 185,000 sf distributed over6 floors (ranging from approximately 24,500 sf to 46,500 sf per level), the building is poised to be transformed from alegacy hospital into a modern, high-performing home for the UC College of Nursing. Opportunities with this projectinclude:• A strategic repositioning of an underutilized asset into a signature academic hub for nursing education, research, andinnovation.• A critical link within UC’s academic health campus, strengthening connectivity to partner colleges, the UC MedicalCenter, and the broader healthcare ecosystem.• An opportunity to create a flexible, simulation-rich environment that supports contemporary and future models ofnursing education, interprofessional collaboration, and student success.The scope of the project includes the following:• Exterior site changes to improve arrival, accessibility, and campus integration and wayfinding.• Exterior building changes to enhance performance and visual identity.• Interior renovation and reconfiguration of Levels 1 through 6 to accommodate CoN needs, additional shared teachingspaces for multi-college use, dining facility that will complement surrounding area food offerings for students andfaculty.• Complete building system replacement.• Targeted fit-out to support specialized program components, including simulation, clinical skills, teaching, research,and administration.• Pre-design support in verifying program, schedule, cost, and phasing options before design is fully initiated.UC’s approach is grounded in close collaboration with UC stakeholders, a disciplined validation of program and budget,and a design vision that reflects the values of the College of Nursing and the University of Cincinnati.Shortlisted firms will receive a copy of the project program.F110-53-2025-OCTPublish Date: 03/20/2026Page 1 of 4Request for Qualifications (Criteria Architect/Engineer) continuedB. Scope of ServicesPursuant to ORC 153.694, professional design firms selected to provide C-A/E services shall not provide any A/Eof Record services for the project for which the professional design firm was selected as the C-A/E.For projects advertised with an appropriately developed Program of Requirements (“POR”), upon award of theAgreement, commence with Design. For projects without such a POR, upon award of the Agreement, commence bydeveloping the Program of Requirements.The selected Criteria Architect/Engineer (“C-A/E”), as a portion of its required Scope of Services and prior to submitting itsproposals, will discuss and clarify with the Owner and/or the Contracting Authority, the cost breakdown of the A/EAgreement detailed cost components to address the Owner’s project requirements.As required by the Agreement, and as properly authorized, provide the following categories of services: Concept andDesign Criteria, and Schematic Design.Refer to the Ohio Facilities Construction Manual for additional information about the type and extent of services requiredfor each. A copy of the standard Agreement can be obtained at the OFCC website at https://ofcc.ohio.gov.During the construction period, provide not less than not applicable hours (excluding travel time) on-site constructionadministration services each week, including (1) attendance at progress meetings, (2) a written field report of each sitevisit, (3) on-site representation comprised of the A/E and its consultant staff involved in the primary design of the project,all having relevant and appropriate types of construction administration experience.For purposes of completing the Relevant Project Experience Matrix in Section F of the Statement of Qualifications (FormF110-330), below is a list of relevant scope of work requirements for this RFQ:1. Existing Building Renovation Design – Higher Education and Healthcare2. Building Façade Design/Existing Building Façade Rework3. Experience with Roof Replacement Design4. Experience with Civil Design/Engineering/Landscape Architecture5. Experience with Structural Design/Engineering6. Experience with Existing Building M/E/P/Utilities/Sprinkler/Fire Alarm Design7. Experience with Higher Education & Healthcare furniture, fixtures, and equipment selection and design8. Experience with tenant fit-outs of leased space9. Experience with BOMA standards10. Experience as a Criteria A/E on State Administered Design Build ProjectsC. Estimated Budget / FundingState Funding:$0Other Funding:$105,000,000Construction Cost: $80,000,000Total Project Cost: $105,000,000D. Anticipated ScheduleProfessional Services Start:Construction Notice to Proceed:Substantial Completion of all Work:Professional Services Completed:05 / 2603 / 2712 / 2601 / 27E. Estimated Basic Fee Range (see note below)1.5% to 1.75%F. EDGE Participation GoalPercent of initial Total A/E Fee:0.0%NOTE: Basic Services include: (1) Concept and Design Criteria, (2) Best Value Selection, (3) Preconstruction, and (4) Construction andCloseout services. The Basic Fee includes all registered design professional services and consultant services necessary for propercompletion of the Basic Services, including validation of existing conditions (but not subsurface or hidden conditions) and preparation of costestimates and design schedules for the project. The Estimated Basic Fee Range is calculated as a percentage of the Estimated Budget forConstruction Cost above, including the Owner’s contingency. The Basic Fee excludes any Additional Services required for the project.G. Basic Service Providers Required (see note below)Lead Criteria A/EDiscipline:ArchitectureSecondaryDisciplines:Civil EngineeringLandscape ArchitectureH. Additional Service Providers RequiredTechnology DesignKitchen Planning/DesignF110-53-2025-OCTPublish Date: 03/20/2026Page 2 of 4Request for Qualifications (Criteria Architect/Engineer) continuedStructural EngineeringMechanical-Electrical-Plumbing Eng.Fire Protection EngineeringNOTE: The lead Criteria A/E shall be (1) any architect holding a certificate issued under section 4703.10 of the Revised Code, (2) anylandscape architect holding a certificate issued under section 4703.36 of the Revised Code, or (3) any engineer holding a certificate issuedunder section 4733.14 of the Revised Code.I. Evaluation Criteria for Selection• Demonstrated ability to meet Owner’s programmed project vision, scope, budget, and schedule on previousprojects.• Previous experience compatible with the proposed project (e.g., type, size).• Relevant past work of prospective firm’s proposed consultants.• Past performance of prospective firm and its proposed consultants.• Qualifications and experience of individuals directly involved with the project.• Proposer’s previous experience (numbers of projects, sizes of projects) when working with its proposedconsultants.• Specification writing credentials and experience.• Proximity of prospective firms to the project site.• Proposer’s apparent resources and capacity to meet the needs of this project.J. Submittal InstructionsFirms are required to submit the current version of Statement of Qualifications (Form F110-330) available via the OFCCwebsite at https://ofcc.ohio.gov.Electronic submittals, if requested, should be combined into one PDF file named with the project number listed on theRFQ and your firm’s name, followed by “SOQ”. Use the “print” feature of Adobe Acrobat or similar software for creating aPDF rather than using a scanner. If possible, please reduce the file size of the PDF. In Acrobat, go to Advanced, thenPDF Optimizer. Electronic submittals are limited to a maximum file size of 25 MB.Paper copies of the Statement of Qualifications, if requested, should be stapled only. Do not use special bindings orcoverings of any type. Cover letters and transmittals are not necessary.CD/DVD copies of the Statement of Qualifications, if requested, should have the sleeve labeled with the project numberand firm name, followed by “SOQ”.Facsimile copies of the Statement of Qualifications will not be accepted.Firms are requested to identify professional registrations, memberships and credentials including: LEED GA, LEED AP,LEED AP+, CCCA, CCM, CCS, CDT, CPE, DBIA, and any other appropriate design and construction industry credentials.Identify that information on the resume page for individual in Block 22, Section E of the F110-330 form.F110-53-2025-OCTPublish Date: 03/20/2026Page 3 of 4Criteria Architect/Engineer Selection Rating FormState of Ohio Standard Forms and DocumentsProject Name Holmes Hosp Nursing RenoProject Number 25181BProposer FirmCity, State, ZipSelection Criteria1. Primary Firm Location, Workload and Size (Maximum 10 points)a. Proximity of firm to project siteb. Amount of fees awarded by Contracting Authority inprevious 24 monthsc. Number of licensed professionalsLess than 100 miles100 miles to 150 milesMore than 150 milesLess than $1,000,000$1,000,000 to $5,000,000More than $5,000,000Less than 4 professionals4 to 10 professionalsMore than 10 professionals2. Primary Firm Qualifications (Maximum 30 points)a. Project management leadb. Project criteria design leadc. Technical staffExperience / ability of project manager tomanage scope / budget / schedule / qualityExperience / creativity of project designer toachieve owner’s vision and requirementsExperience / ability of technical staff to createaccurate and complete design criteria3. Key Consultant Qualifications (Maximum 20 points)a. Key discipline leadsb. Proposed EDGE-certified Consultant participation*Experience / ability of key consultants toperform effectively and collaborativelyOne point for every 2 percent increase inprofessional services over the EDGEparticipation goal4. Overall Team Qualifications (Maximum 10 points)a. Previous team collaborationb. Team organizationLess than 2 sample projects2 to 6 sample projectsMore than 6 sample projectsClarity of responsibility / communicationdemonstrated by table of organization5. Overall Team Experience (Maximum 30 points)a. Previous team performanceb. Experience with similar projects / delivery methodc. Budget and schedule managementd. Knowledge of Ohio Capital Improvements processPast performance as indicated byevaluations and letters of referenceLess than 3 projects3 to 6 projectsMore than 6 projectsPerformance in completing projects withinoriginal construction budget and scheduleLess than 3 projects3 to 6 projectsMore than 6 projectsValueScore520210013Max=30 - 100 - 100 - 100 - 150-50250-50 - 100-34-67 - 100-50-12-34-5* Must be comprised of registered professional design consulting firms and NOT the lead firm - For moreinformation on scoring this and other criteria refer to Document F199-01 - PS Selection Rating Rubric.Notes:Evaluator:NameSubtotalSignatureDateF110-53-2025-OCTPublish Date: 03/20/2026Page 4 of 4
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Marion Franklin Exterior Impr...
Solicitation #: RFQ033181 Requesting Department: Recreation & Parks Document Title: Marion Franklin Exterior
City of Columbus
Bid Due: 7/23/2026
New Outlet Wiring DSCC Buildi...
Solicitation ID: SRC0000040123 Solicitation Name: New Outlet Wiring DSCC Building 6 CSMS Original
State Government of Ohio
Bid Due: 7/13/2026