Concrete Box Beams, Bridge Rail and Components
Project Information
- Bid Title
- Concrete Box Beams, Bridge Rail and Components
- Issuing Agency
- State of West Virginia
- Location
- West Virginia
- Published Date
- Jun 9, 2026
- Closing Date
- Jun 25, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- CRFQ-0803-DOT2600000101-1
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Description: Concrete Box Beams, Bridge Rail and Components
Department: DIVISION OF HIGHWAYS
Buyer: John W Estep
Solicitation Number: CRFQ-0803-DOT2600000101-1
Type: Centralized Request for Quote (CRFQ)
Category: Highways
Closing Date and Time: 06/25/2026 01:30 PM EDT
Buyer InformationBuyer NameJohn W EstepBuyer EmailBuyer Phone304-558-2566Buyer Fax-Important DatesIssue Date06/09/2026Closing Date06/25/2026 01:30 PM EDTBid Opening Date-Last Amended-Department InformationCategoryHighwaysTypeCentralized Request for QuoteDocument Department0803StatusOpenDescriptionConcrete Box Beams, Bridge Rail and ComponentsGroup 1Default Commodity GroupNumber of Lines: 15Line Number Extended Description Commodity Line Description Details Requested 1Box beam must be 5 pieces - 3 feet 0 inches X 55 feet 6 inches. Box beam must have a minimum strength of 5500 psi at detention and 8000 psi at 28 days. Pre-stressing strands must be seven-wire uncoated low relaxation oversize strand (AD = 0.167 square inches), with a minimum tensile strength of 270,000 psi. Interior box beams shall have "Tex-Cote 300 Bridge Cote" Latex Acrylic Copolymer Coating or equivalent applied to the bottom of the beams. Box beam lab reports must accompany the shipping ticket.832-1/2 square feet, 21-Inch Interior Box BeamSpecificationsCommodity Code30101700Quantity1.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information2Box Beam must be 2 pieces - 3 feet 0 inches X 55 feet 6 inches. Box beam must have a minimum strength of 5500 psi at detention and 8000 psi at 28 days. Pre-stressing strands must be seven-wired uncoated low relaxation oversize strand (AS =0.167 square inches), with a minimum tensile strength of 270,000 psi. Exterior box beams shall have "Tex-Cote 30 Bridge Cote" Latex Acrylic Copolymer Coating or equivalent applied to the exposed side and bottom of the beams. Box beam lab reports must accompany the shipping ticket.333 square feet, 21-Inch Exterior Box BeamSpecificationsCommodity Code30101700Quantity1.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information3Joint filler must be 2 inches thick. Joint filler must be 4-3/4 inches X 11-1/8 inches.Sponge Rubber Preformed Joint FillerSpecificationsCommodity Code30101700Quantity12.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information4Pads must be 1-13/16 inches X 4-3/4 inches X 15-1/2 inches.Elastomeric Laminated Bearing Pads (B-2)SpecificationsCommodity Code30101700Quantity4.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information5Bolt or rebar must be 1 inch X 2 feet 0 inches.Swedged Anchor Bolt or #8 Deformed RebarSpecificationsCommodity Code30101700Quantity14.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information6Joint filler must be 2 inches thick. Joint filler must be 4-3/4 inches X 11-1/8 inches.Sponge Rubber Preformed Joint FillerSpecificationsCommodity Code30101700Quantity10.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information7Joint filler must be 2 inches thick. Joint filler must be 4-3/4 inches X 8-3/8 inches.Sponge Rubber Preformed Joint FillerSpecificationsCommodity Code30101700Quantity4.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information8Joint filler must be 2 inches thick. Joint filler must be 6 inches X 3 feet 3-1/4 inches.Sponge Rubber Preformed Joint FillerSpecificationsCommodity Code30101700Quantity14.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information9Joint filler must be 1 inches thick. Joint filler must be 1 feet 9-3/4 inches X 3 feet 3-1/4 inches.Sponge Rubber Preformed Joint FillerSpecificationsCommodity Code30101700Quantity14.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information10Joint filler must be 1 inches thick. Joint filler must be 1 feet 9-3/4 inches X 11-1/8 inches.Sponge Rubber Preformed Joint FillerSpecificationsCommodity Code30101700Quantity4.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information11Washer must have 3-1/2 inch holes. Washer must be 8 inches X 8 inches X 1 inch thick.Sponge Rubber WasherSpecificationsCommodity Code30101700Quantity30.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information12Bridge rail must conform to the standards set for in section 607 of the West Virginia Division of Highways Standard Specifications of Roads and Bridges (adopted 2023). Bridge rail must include inserts, hardward, posts, and guardrail (see plans for detail). Bridge rail (16 bridge guardrail posts with hardware, and 87-1/2 linear feet of guardrail) must be attached to beams by fabricator. Note: Shipping constraints may limit the length of attached guardrail.87-1/2 linear feet. Thrie Beam Bridge RailSpecificationsCommodity Code30101700Quantity1.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information13Bearing place must be 9 inches X 9 inches X 1 inch thick.Post-Tension Bearing PlatesSpecificationsCommodity Code30101700Quantity10.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information14Post tension bar must be 1 inch diameter. Post tension bar must be 5 pieces - 24 feet 4-1/2 inches long. Post tension bar must come with nuts.122 linear feet, Post Tension BarSpecificationsCommodity Code30101700Quantity1.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information15Transition sections must be 6 feet 3 inches. Transition sections must be supplied but NOT attached.Asymmetrical Thrie-Beam Transition SectionSpecificationsCommodity Code30101700Quantity4.00000Unit of MeasureEADelivery Date-View Purchase HistoryAdditional Information - Commodity Codes
-
- NAICS 237310Highway, Street, and Bridge Construction
- NAICS 237990Other Heavy and Civil Engineering Construction
- NAICS 238110Poured Concrete Foundation and Structure Contractors
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Equipment Division Office Roo...
Description: Equipment Division Office Roof and HVAC Replacement Department: DIVISION OF HIGHWAYS Buyer:
State of West Virginia
Bid Due: 7/16/2026
Equipment Division Office Roo...
Description: Equipment Division Office Roof and HVAC Replacement Department: DIVISION OF HIGHWAYS Buyer:
State of West Virginia
Bid Due: 7/16/2026