RFQ 2616 - Inductively Coupled Plasma Mass Spectrometer with Autosampler
Project Information
- Bid Title
- RFQ 2616 - Inductively Coupled Plasma Mass Spectrometer with Autosampler
- Issuing Agency
- East Bay Municipal Utility District
- Location
- California
- Published Date
- Feb 25, 2026
- Closing Date
- Mar 18, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
current rfqs due date for bid package please contact RFQ 2616 - Inductively Coupled Plasma Mass Spectrometer with Autosampler March 18, 2026 John Grimes
510-287-0316
john.grimes@ebmud.com - Attachment Preview
-
EAST BAY MUNICIPAL UTILITY DISTRICTREQUEST FOR QUOTATION (RFQ) No. 2616forINDUCTIVELY COUPLED PLASMA MASS SPECTROMETER WITHAUTOSAMPLERContact Person: John W. Grimes, Buyer IIPhone Number: (510) 287-0316E-mail Address: john.grimes@ebmud.comFor complete information regarding this project, see RFQ posted athttps://www.ebmud.com/business-center/materials-and-supplies-bids/current-requests-quotation-rfqs/ or contact the EBMUD representative listed above. Please note that prospectivebidders are responsible for reviewing this site during the RFQ process, for any published addendaregarding this RFQ.Bids Dueby2:00 p.m.onMarch 18, 2026All bid submissions hand delivered or mailed (USPS, FedEx, UPS, etc.) to the address orPO Box noted below and must be received no later than 2:00 p.m. on the bid due date.RESPONSE DELIVERED BY SERVICE(UPS, FedEx, DHL, etc., duringbusiness hours: 8:00 AM – 3:30PM only) to:RESPONSE DELIVERED BY MAIL(U.S. Postal Service) to:EBMUD–Purchasing DivisionINDUCTIVELY COUPLED PLASMAMASS SPECTROMETER WITHAUTOSAMPLER – RFQ 2616375 11th StreetOakland, CA 94607REV: 9/23/25EBMUD–Purchasing DivisionINDUCTIVELY COUPLED PLASMAMASS SPECTROMETER WITHAUTOSAMPLER – RFQ 2616P.O. Box 24055Oakland, CA 94623RESPONSE HAND-DELIVERED(during business hours: 8:00AM – 4:00 PM only)EBMUD–Purchasing DivisionINDUCTIVELY COUPLEDPLASMA MASS SPECTROMETERWITH AUTOSAMPLER – RFQ2616Purchasing Office375-11TH Street, 1st FloorOakland, CA 94607EAST BAY MUNICIPAL UTILITY DISTRICTRFQ No. 2616forINDUCTIVELY COUPLED PLASMA MASS SPECTROMETER WITH AUTOSAMPLERTABLE OF CONTENTSI. STATEMENT OF WORK ........................................................................................................... 3A. SCOPE................................................................................................................................... 3B. BIDDER QUALIFICATIONS .................................................................................................... 3C. SPECIFIC REQUIREMENTS .................................................................................................... 3D. FAILURE TO MEET SPECIFICATIONS................................................................................... 16II. CALENDAR OF EVENTS ......................................................................................................... 17III. DISTRICT PROCEDURES, TERMS, AND CONDITIONS .............................................................. 17A. RFQ ACCEPTANCE AND AWARD ........................................................................................ 17B. BRAND NAMES, APPROVED EQUIVALENTS, DEVIATIONS, AND EXCEPTIONS .................. 17C. PRICING.............................................................................................................................. 18D. NOTICE OF INTENT TO AWARD AND PROTESTS................................................................ 18E. METHOD OF ORDERING .................................................................................................... 19F. TERM / TERMINATION / RENEWAL ................................................................................... 20G. WARRANTY ........................................................................................................................ 20H. INVOICING ......................................................................................................................... 20IV. RFQ RESPONSE SUBMITTAL INSTRUCTIONS AND INFORMATION ......................................... 21A. DISTRICT CONTACTS .......................................................................................................... 21B. SUBMITTAL OF RFQ RESPONSE ......................................................................................... 21ATTACHMENTSEXHIBIT A – RFQ RESPONSE PACKETEXHIBIT B – INSURANCE REQUIREMENTSEXHIBIT C – GENERAL REQUIREMENTSREV: 9/23/25INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER WITH AUTOSAMPLERI. STATEMENT OF WORKA. SCOPEIt is the intent of these specifications, terms, and conditions to describe requirement tofurnish, install, test and validate one (1) new bench top inductively coupled plasma massspectrometer with autosampler f.o.b. destination to the District’s SD-1 Laboratorylocated at 2020 Wake Avenue, Oakland, CA 94607.East Bay Municipal Utility District (District) intends to award a contract to the lowestcost bidder(s) whose response meets the District’s requirements.B. BIDDER QUALIFICATIONS1. Bidder Minimum Qualificationsa. Bidder, bidder’s principal, or bidder’s staff shall have been regularlyengaged in the business of providing inductively coupled plasma massspectrometers for at least ten (10) years.b. Bidder shall be a certified and/or authorized manufacturer and dealer ofthese instruments.c. Bidder shall possess all permits, licenses, and professional credentialsnecessary to supply product and perform services as specified under thisRFQ.C. SPECIFIC REQUIREMENTSAll products shall be in new and unused condition and shall be of the most current andup to date model.1. GENERAL – QUADROPOLE ICP-MS INSTRUMENTThe vendor shall furnish, install, test and validate one new bench top inductivelycoupled plasma mass spectrometer (ICP-MS) for trace metals analysis. The ICP-MS must satisfy the specifications outlined in the Criteria Table. The instrumentwill detect metals in source water, ground water, drinking water, wastewater,salt water and industrial waste for analysis at concentrations ranging from 0.4ppb to 1000 ppb. The instrument acceptance process shall include calibration ofanalytes of interest in the Table for EPA 200.8. The method verification willinclude running standards at the required method reporting limits for drinkingwater and wastewater compliance, demonstrating instrument check blanksRFQ No. 2616Page 3INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER WITH AUTOSAMPLERbelow the Method Detection Limits (MDLs) in the Table and provide an InitialDemonstration of Capability (IDOC) that meets all method quality control criteria.The system must include an enclosed autosampler with connection to ventilation,a liquid sample introduction system, an RF argon plasma ion source, aquadrupole based cell to eliminate spectroscopic interferences with KED usingcollision gases, quadrupole mass filter, simultaneous dual stage discrete dynodedetector and at least two-cone plasma interface, all under computer control.Note: EBMUD will provide an I7 WIN11 PC with 32gb RAM that the bidder willneed to work with District IT to install the software on site during instrumentinstallation.The table below is divided into sections of instrument criteria. For the ‘Location in Proposal’ field, pleaseindicate where in the proposal the information is provided that indicates this criteria is met (a page # andparagraph or section). For those items that are not shaded in the last field, please also provide a reference toan attachment of raw data or other instrument documentation that indicates the item criteria is met and acustomer reference that currently uses the instrument in this configuration. For example, Section 2b requiresdocumentation and a reference to confirm MDLs have been met. Please provide the raw data and a summaryof tabulated MDL data from the instrument with a date and time stamp in a spreadsheet file. Please use aminimum amount of documentation to confirm availability of these criteria, such as a single page.Section2abcdefghijkItemICP-MS GENERAL SYSTEM REQUIREMENTSSystem must be fully compliant with US EPA methodology for Method200.8Based on analyzing MB & low-level spikes using the calibration in Table1, the system must meet or exceed the MDLs in Table 1 for both Water& WastewaterFully automated system startup, shutdown and optimization andcomputer-controlled instrument tuning for optimum performance. Thisincludes software startup & shutdown of equipment used for cooling thesystem, such as a chiller or other heat exchange deviceQuadrupole must be able to scan a minimum of 3000 amu/sec toachieve maximum productivity from transient signals when jumpingbetween light masses and high massesQuadrupole resolution settings are dynamically scanned as each elementis analyzedMass range must be at least 4 to 260 amu or greaterRemote service trouble shooting and remote operation of systemAll sample introduction, analytical system, data acquisition, methodvalidation and quality control operations using a single softwareprogramFull system must use single-phase power and remain in specificationtemperature range of 10 to 30°C at up to 2°C per hourSystem must be able to be sufficiently cooled in laboratory temperaturesbelow 30°CSoftware automation available to optimize operating conditions andpass tune with each batchLocation in ProposalData IncludedRFQ No. 2616Page 4INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER WITH AUTOSAMPLERSectionl3abcdefghItemSystem must be able to calibrate, detect and use correction equation for1/2 masses and detection of Nd, Sm, Gd, DySAMPLE INTRODUCTIONSample introduction system has concentric nebulizer, cyclonic or doublepass spray chamber, quartz injector and no o-ringsSample introduction uses a computer controlled integral peristalticpump. Must be integrated within the ICP-MS systemSystem is configured for automated addition of internal standards to allsamples and standardsEntire torch and injector assembly can be removed and installed by handin a tool-less fashionCone and torch apparatus single orientation or one fit-type for ease ofassemblyFully automated one touch X, Y, Z torch alignmentNo carryover >MDL to subsequent samples, standards and blanks fromsamples or standards with concentrations up to 1000 ppbLinear Dynamic Range up to 1000 ppbLocation in ProposalData IncludediSample introduction system is capable of providing an aerosol as well asliquid dilution.4ION SOURCE AND RF GENERATORaComputer controlled RF generator allows for automatic control of torchignition, shutdown, and system warm upbAllows independent adjustment of the ion optic parameters and theplasma conditions5PLASMA INTERFACEaDesign with rapid mounting and removal cone design, easily accessiblefrom the front of the instrumentMechanism for complete separation of ions from photons and neutralsbeither with 90 degree bend of ion path or a chicane , making the cell andmass analyzing quadrupole completely maintenance free6COLLISION CELLSystem must incorporate a collision cell with two modes of operation:aStandard Mode and Collision Cell Mode with KED and the ability toutilize a wide variety of gases for the life of instrument with nodegradation to the gas channels, turbo pump or cellIn Standard Mode, the collision cell must be able to operate with no gasband no energy barrier for optimal signal-to-noise performance onelements with any interferenceIn Collision Cell Mode, the collision cell must be able to operate as acpassive ion guide with an energy barrier at the cell exit for KED. Theflow and optimization of the gases shall be under full operator controldInstrument provides transition into and out of collision cell mode andcomplete stability in <3 seconds7QUADRUPOLE MASS ANALYZERRFQ No. 2616Page 5
- Commodity Codes
-
- NAICS 334516Analytical Laboratory Instrument Manufacturing
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
CIP GG 23-11 - Lathrop Animal...
CIP GG 23-11 - Lathrop Animal Center Bid/RFP Status: Open - accepting bids
City of Lathrop
Bid Due: 7/21/2026
Notification of Intent to Con...
Follow Notification of Intent to Consolidate Requirements - HCD-W Cost-Per-Reportable-Results Chemistry Testing Supplies
DEPT OF DEFENSE