Garden City Fire Station - RAILINGS
Project Information
- Bid Title
- Garden City Fire Station - RAILINGS
- Issuing Agency
- Garden City city
- Location
- Michigan
- Published Date
- Feb 14, 2026
- Closing Date
- Feb 24, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- 26-02-24-1200
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid Number: 26-02-24-1200
Bid Title: Garden City Fire Station - RAILINGS
Category: Bid Postings Status: Open Description: NOTICE TO BIDDERS
NOTICE IS HEREBY GIVEN that SEALED BIDS will be received at the Office of the City Clerk, located in the Civic Center, 6000 Middlebelt Road, Garden City, Michigan 48135-2499, on or before Tuesday, February 24 th., 2026 @ 12pm. for the following item:
Garden City Fire Station – RAILINGS
Two (2) copies of the bid proposal will be received by: City of Garden City
Attention: Garden City Fire Station – Railings
6000 Middlebelt Road
Garden City, MI 48135
SITE WALK THROUGH: Thursday, February 19 th., 2026 @ 3pm.
RFI Deadline: Friday, February 20 th., 2026 @ 3 pm.
BID DUE DATE: Tuesday, February 24 th., 2026 @ 12pm.
Bids shall be publicly opened and read on: Tuesday, February 24th., 2026 @ 12:30pm. at:
City of Garden City Clerk’s Office
6000 Middlebelt Road
Garden City, MI 48135
Garden City has partnered with BidNet as part of the Michigan Inter-governmental Trade Network and will post their bid opportunities to that site. As a vendor, you can register with the Michigan Inter-governmental Trade Network and be sure that you will see all available bids and opportunities. This information can be found on the City's website at http://www.gardencitymi.org/218/Purchasing.
Any questions (RFI's) should be directed to Metrix Management c/o Mike Wadenstorer at Mike@MetrixMgmt.com
For security reasons, you must enable JavaScript to view this E-mail address. until Friday, February 20th, 2026 @ 3pm.Bids should have two copies enclosed and submitted in a sealed envelope marked sealed bid for “Garden City Fire Station – RAILINGS ”
Publication Date/Time: 2/13/2026 5:00 PM Closing Date/Time: 2/24/2026 12:00 PM Pre-bid Meeting: Job Walk 2/19/26 @ 3:00PM Contact Person: Mike Wadenstorer - Metrix Management
Mike@MetrixMgmt.comRelated Documents: - Attachment Preview
-
GARDEN CITY FIRE STATION6000 MIDDLEBELT RDGARDEN CITY, MI 48135GENERAL NOTES:ARCHITECT:Scheible &AssociatesL.L.C.46 Kensington Blvd.Pleasant Ridge, MI 48069(248) 797-9890scheibleassociates.comDRAWN BY:GENERAL NOTES:THESE GENERAL, ARCHITECTURAL, MECHANICAL AND ELECTRICAL NOTES APPLY TOEACH SHEET OF DRAWINGS LISTED HEREIN BELOW AS WELL AS THOSE PREPARED BYOTHERS RESPONSIBLE FOR SEALED MECHANICAL AND ELECTRICAL PERMIT, BIDDINGAND CONSTRUCTION.THE SCOPE OF WORK INVOLVES THE RENOVATION AND/OR BUILD-OUT OF DEMISEDOFFICE SPACE COMPLETE AND READY FOR OCCUPANCY BY THE TENANT. THEARCHITECTURAL TRADES WORK IS REFLECTED IN THESE DRAWINGS ANDSPECIFICATIONS WHICH ARE RELEASED FOR PERMITS, BIDDING AND CONSTRUCTION.CONTRACTOR’S BID PROPOSAL SHALL INCLUDE ALL COSTS TO PROVIDE ANY AND ALLLABOR, MATERIALS, EQUIPMENT, SUPERVISION AND PERMITS NECESSARY TOCOMPLETE THE PROJECT, READY FOR OCCUPANCY.THE SCOPE OF PLUMBING, HVAC, FIRE PROTECTION, ELECTRICAL, FIRE ALARM ANDRELATED WORK SHOWN IN THESE DRAWINGS AND SPECIFICATIONS REFLECT “DESIGNINTENT”. CONTRACTOR(S) FOR TRADES OTHER THAN ARCHITECTURAL MUSTPREPARE DRAWINGS AND/OR SPECIFICATIONS FOR PERMIT, BIDDING AND ONCONSTRUCTION WHICH FULLY DOCUMENT THE SCOPE OF WORK, ARE COMPLIANTWITH CODES AND ORDINANCES PROMULGATED BY BODIES HAVING JURISDICTIONOVER THE PROJECT AND BEAR THE SEAL OF AN ARCHITECT OR ENGINEER LICENSEDIN THE STATE OF MICHIGAN. CONTRACTOR BID PROPOSALS SHALL INCLUDE ALLCOSTS TO PROVIDE ANY AND ALL LABOR, MATERIAL, EQUIPMENT, SUPERVISION ANDPERMITS NECESSARY TO COMPLETE THE PROJECT READY FOR OCCUPANCY.A COPY OF ALL SEALED DRAWINGS PREPARED FOR THIS PROJECT FOR WORK SCOPEAND TRADES OTHER THAN ARCHITECTURAL SHALL BE FORWARDED TO SCHEIBLE &ASSOCIATES AND NCS-TEAM FOR THEIR FILES.EACH CONTRACTOR IS RESPONSIBLE FOR KEEPING THE CONSTRUCTION AREA ASWELL AS THE REMAINDER OF THE BUILDING BOTH THE DELIVERY OF MATERIALS ANDTHE REMOVAL OF DEBRIS SHALL BE COORDINATED WITH THE BUILDINGMANAGEMENT INCLUDING, BUT NOT LIMITED TO, PERMITTED HOURS OF WORK,BUILDING AND CONSTRUCTION AREA ACCESS, LOCATION OF DUMPSTERS,TEMPORARY TOILET FACILITIES, USE OF ELEVATORS AND TEMPORARY PROTECTIONOF EXISTING FINISHED MATERIALS.EACH CONTRACTOR IS RESPONSIBLE FOR MINIMIZING NOISE AND DISRUPTION OFOTHER TENANTS AND THEIR VISITORS – BOTH ADJACENT TO AND THE OCCUPANTSOF THE FLOORS ABOVE AND BELOW THE DEMISED SPACE.INTERRUPTION OF EXISTING BUILDING SYSTEMS INCLUDING, BUT NOT LIMITED TO,POWER, LIGHTING, FIRE PROTECTION, FIRE ALARM, MEANS OF EGRESS, ACCESS TOEXITS, ELEVATORS AND OTHER IMPACTS TO LIFE SAFETY MUST HAVE THE PRIORAPPROVAL OF AND BE COORDINATED WITH THE BUILDING OWNER(S) AND/OR THEIRAUTHORIZED AGENTS.EACH CONTRACTOR EMPLOYED ON THE PROJECT IS SOLELY RESPONSIBLE FORCONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURESAND FOR COORDINATION OF THE WORK OF OTHER CONTRACTORS EMPLOYED BYTHE BUILDING OWNER(S) AND/OR ITS AUTHORIZED AGENTS.PATCHING AND REPAIR OF EXISTING CONSTRUCTION OR SYSTEMS SHALL BECOMPLETED AND REFINISHED, AS NECESSARY AND APPROPRIATE, TO ASSURE ANEVEN FINISH TO MATCH EXISTING ADJACENT CONSTRUCTION. FOR CONTINUOUSSURFACES, REFINISH TO THE NEAREST INTERSECTION. FOR AN ASSEMBLY, REFINISHTHE ENTIRE UNIT.EACH CONTRACTOR IS RESPONSIBLE FOR SECURING INSPECTIONS AND OBTAININGTHE WRITTEN APPROVAL OF REGULATORY AGENCIES HAVING JURISDICTION OVERTHE PROJECT, INCLUDING FINAL INSPECTIONS AND OCCUPANCY.CONFIRM WITH THE BUILDING OWNER(S) AND/OR THEIR AUTHORIZED AGENTS THEREQUIREMENTS FOR “PROJECT CLOSEOUT” INCLUDING WARRANTIES,MANUFACTURER’S PRODUCT DATA, SHOP DRAWINGS, SAMPLES AND “AS-BUILT”DRAWINGS. PROVIDE COPIES OF CLOSEOUT DOCUMENTS TO SCHEIBLE &ASSOCIATES AND NCS-TEAM FOR THEIR FILES.ARCHITECTURAL NOTES:UNLESS OTHERWISE NOTED, THE SCOPE OF WORK REFLECTED IN THESE DRAWINGS ANDSPECIFICATIONS IS INTENDED TO MATCH “EXISTING” AND/OR “BUILDING STANDARD”PROMULGATED BY THE BUILDING OWNER(S) AND/OR THEIR AUTHORIZED AGENTS.EACH CONTRACTOR EMPLOYED ON THIS PROJECT IS RESPONSIBLE FOR VISITING THESITE AND VERIFYING EXISTING CONDITIONS AFFECTING ITS WORK OR WORK WHICH MUSTBE COORDINATED WITH OTHER TRADES. SUBMIT A REQUEST FOR INFORMATION(RFI) TO THE ARCHITECT IDENTIFYING CONFLICTS OR SEEKING CLARIFICATION, PRIOR TOPROCEEDING WITH THE WORK. THE ARCHITECT WILL PROMPTLY RESPOND, IN WRITING.DO NOT SCALE DRAWINGSSELECTIVE DEMOLITION SHOWN ON THE DRAWINGS, UNLESS OTHERWISE NOTED, SHALLINCLUDE THE COMPLETE REMOVAL AND LEGAL DISPOSAL OF EXISTING CONSTRUCTION,UNLESS OTHERWISE NOTED TO BE SALVAGED. COORDINATE SELECTIVEDEMOLITION OPERATIONS WITH PLUMBING, HVAC AND ELECTRICAL TRADES, WHERESHOWN OR NECESSARY.IN CONSULTATION WITH THE BUILDING OWNER(S) AND/OR THEIR AUTHORIZED AGENTS,KEY THE DEMISED SPACE AS REQUIRED BY THE TENANT.MECHANICAL (PLUMBING, HVAC & FIRE PROTECTION) NOTES:MECHANICAL WORK, BOTH SELECTIVE DEMOLITION AND NEW CONSTRUCTION, SHOWN ONTHESE DRAWINGS REFLECT “DESIGN INTENT”. MECHANICAL TRADES CONTRACTOR(S) ARERESPONSIBLE FOR VERIFYING EXISTING CONDITIONS, BOTH INTERNAL ANDEXTERNAL TO THE DEMISED PREMISES AND THE PREPARATION OF DETAILED DRAWINGS,RISERS, SPECIFICATIONS AND CALCULATIONS NECESSARY. PERMIT, BIDDING ANDCONSTRUCTION DRAWINGS SHALL BE COORDINATED WITH THESE DRAWINGSAND THOSE OF OTHER CONTRACTORS AND MUST BEAR THE SEAL OF AN ARCHITECT ORENGINEERING LICENSED IN THE STATE OF MICHIGAN.UNLESS OTHERWISE NOTED, CONSTRUCTION AND MATERIALS SHALL MATCH “EXISTING”AND CONFORM TO “BUILDING STANDARD”. REVIEW LOCATION OF THERMOSTATICCONTROLS WITH THE BUILDING OWNER(S) AND/OR THEIR AUTHORIZED AGENTS, PRIORTO INSTALLATION.FORWARD A COPY OF THE APPROVED, SEALED DRAWINGS TO SCHEIBLE & ASSOCIATESAND NCS-TEAM FOR THEIR FILES.BRING ANY COORDINATION ISSUES AND CONFLICTS BETWEEN THE MECHANICAL,ELECTRICAL AND THE ARCHITECTURAL DRAWINGS TO THE ATTENTION OF THEARCHITECT FOR RESOLUTION PRIOR TO ENTERING INTO CONTRACT. THE ARCHITECTSHALL BE PROMPTLY ADVISED OF ANY CONFLICTS OR COORDINATION ISSUES ARISINGDURING CONSTRUCTION. SUBMIT AN RFI TO THE ARCHITECT PRIOR TO PROCEEDING WITHTHE WORK. THE ARCHITECT WILL PROMPTLY RESPOND, IN WRITING.TO THE EXTENT POSSIBLE, CONTINUE TO USE EXISTING OR PROVIDE TEMPORARYPLUMBING, FIRE PROTECTION AND HVAC SYSTEMS INCLUDING, BUT NOT LIMITED TO,DUCTWORK, DIFFUSERS, GRILLES OR CONTROLS TO SERVE AS “TEMPORARY HEATINGAND/OR COOLING” DURING CONSTRUCTION OPERATIONS. ASSURE THAT DUST AND DIRT,FROM CONSTRUCTION OPERATIONS BY ANY TRADE, DOES NOT CONTAMINATE EXISTINGDUCTWORK TO REMAIN OR EXISTING HVAC EQUIPMENT SERVING THE DEMISED SPACE ORADJACENT PORTIONS OF THE BUILDING. CHANGE FILTERS UPON COMPLETION AND PRIORTO OCCUPANCY.PRIOR TO PROJECT COMPLETION, BALANCE ALL WATER & AIR SYSTEMS AND ISSUE AREPORT TO THE BUILDING OWNER AND/OR ITS AUTHORIZED AGENTS WITH COPIES TOSCHEIBLE & ASSOCIATES AND NCS-TEAM FOR THEIR FILES.ELECTRICAL, PHONE/DATA & FIRE ALARM NOTES:ELECTRICAL WORK, BOTH SELECTIVE DEMOLITION AND NEW CONSTRUCTION, SHOWN ONTHESE DRAWINGS REFLECT “DESIGN INTENT”. ELECTRICAL TRADE CONTRACTOR(S) ARERESPONSIBLE FOR VERIFYING EXISTING CONDITIONS, BOTH INTERNAL ANDEXTERNAL TO THE DEMISED PREMISES AND PREPARING DETAILED DRAWINGS, RISERS,SPECIFICATIONS AND CALCULATIONS NECESSARY. PERMIT, BIDDING AND CONSTRUCTIONDRAWINGS SHALL BE COORDINATED WITH THESE DRAWINGS AND THOSE OF OTHERCONTRACTORS AND MUST BEAR THE SEAL OF AN ARCHITECT OR ENGINEER LICENSED INTHE STATE OF MICHIGAN.UNLESS OTHERWISE NOTED, CONSTRUCTION AND MATERIALS SHALL MATCH EXISTINGAND CONFORM TO “BUILDING STANDARD” .REVIEW LOCATION OF THERMOSTATICCONTROLS WITH THE BUILDING OWNER(S) OR THEIR AUTHORIZED AGENTS, PRIOR TOINSTALLATION.ALL LOW VOLTAGE WORK INCLUDING PHONE, DATA, FIRE ALARM TO BE PERFORMED BYOWNERFORWARD A COPY OF THE APPROVED, SEALED DRAWINGS TO SCHEIBLE & ASSOCIATESAND NCS-TEAM FOR THEIR FILES.BRING ANY COORDINATION AND CONFLICTS BETWEEN THE ELECTRICAL, MECHANICALAND ARCHITECTURAL DRAWINGS TO THE ATTENTION OF THE ARCHITECT FORRESOLUTION PRIOR TO ENTERING INTO CONTRACT. THE ARCHITECT SHALL BE PROMPTLYADVISED OF ANY CONFLICTS OR COORDINATION ISSUES ARISING DURINGCONSTRUCTION. SUBMIT AN RFI TO THE ARCHITECT PRIOR TO PROCEEDING WITH THEWORK. THE ARCHITECT WILL PROMPTLY RESPOND, IN WRITING.TO THE EXTENT POSSIBLE, CONTINUE TO USE EXISTING ELECTRICAL SYSTEMS,MODIFYING LIGHTING OR POWER PANELS, SWITCHING, EXIT AND EMERGENCY LIGHTINGAND FIRE ALARM TO SERVE AS “TEMPORARY POWER & LIGHTING” DURINGCONSTRUCTION OPERATIONS.PRIOR TO PROJECT COMPLETION, CLEAN ALL LIGHT FIXTURES USED AS “TEMPORARYLIGHTING”, TEST ALL CIRCUITS AND FIRE ALARM DEVICES AND PROVIDE NEW LABELS INPOWER & LIGHTING PANELS.UPUPUPUPUPDNUPUPWHFURN FURNDNCS TEAMOne Towne SquareSuite 150Southfield, MI 48076Tel: 989-992-6179www.ncs-team.comJosh@NCS-Team.comFIRST FLOOR KEY PLANNORTHNO SCALELIST OF DRAWINGST-1A-1.0A-1.1A-1.2A-1.3A-1.4A-2.0A-3.0A-4.0A-5.0A-5.1A-5.2A-6.0TITLE SHEET, GENERAL NOTES, KEY PLAN, CODE ANALYSISDEMOLITION FLOOR PLANDEMOLITION CEILING PLANDEMOLITION ELEVATIONSDEMOLITION ELEVATIONSROOF DEMOPARTITION FLOOR PLANREFLECTED CEILING PLANDOOR & WINDOW PLAN, DOOR SCHEDULE, ROOM FINISH SCHEDULENEW ELEVATIONNEW ELEVATIONDETAILS & SECTIONSNEW ROOF PLANCODE ANALYSISARCHITECT INFOREVIEW CODETOTAL FLOORS IN BLDG.USE GROUPOCCUPANT LOAD:TYPE OF CONSTRUCTIONBUILDING SQUARE FOOTAGEEXIT ACCESSSPRINKLER SYSTEMNAME: DONALD J SCHEIBLELICENSE NUMBER: 1301018960EXPIRATION DATE: 01-01-27EMAIL: DSCHEIBLE@SCHEIBLEASSOCIATES.COM2021 MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS LEVEL 22021 MICHIGAN MECHANICAL CODE2021 MICHIGAN PLUMBING CODE2023 NATIONAL ELECTRIC CODE2021 MICHIGAN ENERGY CODE INCLUDING ASHRAE 90.1-20132009 ICC/ANCI A117.1 STANDARD FOR ACCESSIBLE BUILDINGS & FACILITIES1SEPARATED MIXED USE S2 / R3 / B / A-3ISSUED FOR:BID PACK 110-06-25A-3 506 SF/15= 34 OCCUPANTSB SHIFT STAFF MAX 10 OCCUPANTSMAX. OCCUPANT LOAD 44 PERSONSPERMIT11-21-25TYPE V-B8,417 SFSEAL:2 EXITS REQUIRED4 EXITS PROVIDEDSPRINKLER SYSTEM IS NOT PROVIDEDSHEET#DATE:T-110-06-255'-0"REMOVE WINDOWS, PREPFOR NEW EGRESS WINDOWSREMOVE VENTED SOFFIT, PROPFOR NEW VENTED SOFFITNEW FLASHING & SIDINGPARTITION LEGENDEXISTING PARTITION TO BE REMOVED. PATCH & REPAIR ALL FLOORS,WALLS, COLUMNS ENCLOSURES & CEILING AS REQ'D (TYP.)EXISTING PARTITION OR PERIMETER WALL TO REMAIN24'-1"5'-7"18'-6"ARCHITECT:Scheible &AssociatesL.L.C.46 Kensington Blvd.Pleasant Ridge, MI 48069(248) 797-9890scheibleassociates.comDRAWN BY:REVISION 122'-0"REVISION 1REMOVE DOORREMOVE EARTH INTHIS AREA, PREPFOR NEW RAMPREMOVE EARTH INTHIS AREA, PREPFOR NEW CONCRETE15'-11"REMOVE FLOOR,PREP FOR NEWRAMPUP5'-0"±7'-0"REMOVE WINDOW,PREP FOR NEWREMOVE WINDOWS, PREPFOR NEW EGRESS WINDOWSREMOVE LOW VOLTAGE ENTRY KEYPADAND SAVE FOR RELOCATION BY OWNERREMOVE STEP &DOOR AS SHOWNREMOVE CONCRETETO JOINT TO FIXPLUMBING CLEAN OUTEXISTING CONCRETETO REMAIN AS ISREMOVE CONCRETE,PREP AREA FOR NEWCATCH BASIN ANDCONCRETEUPREMOVE DOORS, SAVEFOR RELOCATIONUPUPREMOVE EARTH,PREP FOR NEWCONC WALKREMOVECONCRETE PREPFOR NEWLANDING & RAMPREMOVEMEMORIALPLAQUEREVISION 1REMOVE EARTH,PREP FOR NEWCONC RAMPREMOVE WINDOWS, PREPAREA TO BE FILLED INDNREMOVE CONCRETE,PREP AREA FOR NEWCONCRETE, LEVELWITH EXISTINGINTERIOR SLAB5'-8"REVISION 1REMOVE EXISTING SIDEWALK3'-4" 4"DEMO & DISPOSE OFEXISTING HOSE DRYER UNITREMOVE CONCRETE,PREP AREA FOR NEWRAMP UP INTO SPACEUPUPWHREMOVE CONCRETE,TRENCH FOR NEWSANITARY PLUMBING RUNREMOVE SHED, FIX GRADEREMOVE FLASHING & PREP FORNEW FLASHINGNEW FLASHING & SIDINGDEMOLITION FLOOR PLANNORTHSCALE: 3/16" = 1'-0"UPREMOVE VENTED SOFFIT, PROPFOR NEW VENTED SOFFITREMOVE FLASHING & PREP FORNEW FLASHING5'-5"10'-0"REMOVE EARTH IN THIS AREAFOR NEW CONCRETE PARKINGREMOVE CONCRETE, PREP FORREINSTALLATION OF NEWCONCRETEEXISTING LAWN TOREMAIN AS ISEXISTING SIDEWALKTO REMAIN AS ISNCS TEAMOne Towne SquareSuite 150Southfield, MI 48076Tel: 989-992-6179www.ncs-team.comJosh@NCS-Team.comEXISTING CONCRETETO REMAIN AS IS5'-5"UPREMOVE EARTH IN THIS AREAFOR NEW CONCRETE20'-112"EXISTING SIDEWALKTO REMAIN AS ISEXISTING LAWN TOREMAIN AS ISEXISTING FLAG POLETO REMAIN AS IS12'-712"7'-6"20'-112"ISSUED FOR:BID PACK 110-06-25REVISION 111-19-25PERMIT11-21-25SEAL:SHEET#DATE:A-1.010-06-25N.V.N.V.REMOVE ALL LIGHTINGFROM SOFFIT8'-0"SPSPSPSPSPWIFISPWIFIHSD8'-0"WIFIHSPUPSPSP8'-0"UPREMOVE CIRCUIT & INFILL WITHBRICK. REMOVE PREVIOUSMOUNTING HARDWARE7'-10"SPWIFIB of T18'-1"REMOVE CIRCUIT & INFILL WITHBRICK. REMOVE PREVIOUSMOUNTING HARDWAREREMOVE CAP, PREPVENT RADIANT HEATEXHAUST LINETHROUGH NEW ROOF17'-6"REMOVE ALL LIGHTINGFROM SOFFITHSD7'-9.5"WIFIMDSP7'-9.5"SPSP7'-9.5"7'-10"SP8'-0"7'-10"UPUPHEAT TUBEDEMOLITION REFLECTED CEILING LEGENDEXISTING EXTERIOR LAY-IN FLUORESCENT EXTERIORLIGHT FIXTURE TO BE REMOVEDEXISTING WALL MTD. LIGHT TO BE REMOVED / RELOCATED7'-10"SDSP7'-10"SPB of T9'-10"REMOVE CIRCUIT & INFILL WITHBRICK. REMOVE PREVIOUSMOUNTING HARDWAREEXISTING REFLECTED CEILING LEGENDEXISTING 2x4 LAY-IN FLUORESCENT LIGHT FIXTUREWITH ACRYLIC PRISMATIC LENS TO REMAINEXISTING 2x2 LAY-IN FLUORESCENT LIGHT FIXTUREWITH ACRYLIC PRISMATIC LENS TO REMAINEXISTING 2x2 HVAC RETURN DIFFUSER TO REMAIN (OR BEMOVED TO PREFERABLE LOCATION AS DETERMINED BY HVACCONTRACTOR / ENGINEER)EXISTING 2x2 HVAC SUPPLY DIFFUSER TO REMAIN (OR BEMOVED TO PREFERABLE LOCATION AS DETERMINED BY HVACCONTRACTOR / ENGINEER)EXISTING CEILING MTD. EXIT LIGHT TO REMAINSPEXISTING SPEAKER TO REMAINMDEXISTING MOTION DETECTOR TO REMAINHEXISTING FIRE HORN STROBE TO REMAINEXISTING RECESSED DOWNLIGHT TO REMAINWIFIEXISTING CEILING WIFI TO REMAINEXISTING WALL MTD. LIGHT TO REMAINXEXISTING SWITCH TO REMAINARCHITECT:Scheible &AssociatesL.L.C.46 Kensington Blvd.Pleasant Ridge, MI 48069(248) 797-9890scheibleassociates.comDRAWN BY:NCS TEAMOne Towne SquareSuite 150Southfield, MI 48076Tel: 989-992-6179www.ncs-team.comJosh@NCS-Team.com17'-8"REMOVE CIRCUIT & INFILL WITHBRICK. REMOVE PREVIOUSMOUNTING HARDWAREREMOVE ALL CEILING GRID, TILES,UPLIGHTING AND HVAC VENTS IN THISAREA. PREP FOR NEW LAY IN CEILINGDNB of T10'-6"REMOVE ALL STEAM LINE8'-0"11'-8"HEAT TUBEUPWH8'-0"UPUPB of T9'-10"SP9'-8"FURN FURNDSP8'-0"REMOVE ALL LIGHTINGFROM SOFFITISSUED FOR:BID PACK 110-06-25PERMIT11-21-25SEAL:REFLECTED CEILING DEMO PLANNORTHSCALE: 3/16" = 1'-0"SHEET#DATE:A-1.110-06-25REMOVE ALL BOARD &BATTEN SIDING, PREPFOR NEW MATERIAL TBDREMOVE WINDOW PREPFOR NEW WINDOWREMOVE DOOR & KEYPAD,SAVE KEYPAD FOR NEWENTRY DOORREMOVE ALL CURRENTROOF & STRUCTUREFOR NEW STRUCTURE &FUTURE SHED ROOFALTERNATE PRICE TOREMOVE & REPLACEWINDOWSREMOVE ALL CURRENTROOFING & OSB, CDX ASLONG AS NOT DAMAGEDCAN REMAINREMOVE ALL CURRENTROOF & STRUCTURE FORNEW STRUCTURE &FUTURE SHED ROOFARCHITECT:Scheible &AssociatesL.L.C.46 Kensington Blvd.Pleasant Ridge, MI 48069(248) 797-9890scheibleassociates.comDRAWN BY:ALTERNATE PRICE TOREMOVE & REPLACEWINDOWSALTERNATE PRICE TOREMOVE & REPLACEWINDOWSALTERNATE PRICE TOREMOVE & REPLACEWINDOWSREMOVE SHEDREMOVE FLASHING, BOARD &BATTEN SIDING PREP FOR NEWWINDOWS & NEW MATERIALREMOVE FLASHING, BOARD &BATTEN SIDING PREP FOR NEWWINDOWS & NEW MATERIALDEMOLITION NORTH ELEVATION OF NORTH WINGSCALE: 1/4" = 1'-0"REMOVE FLASHING, BOARD &BATTEN SIDING PREP FOR NEWWINDOWS & NEW MATERIALDEMOLITION NOTES:REMOVE ENTIRE METAL ROOF, J-TRIM & FACIA PREP FOR RE-INSTALLATION DUETO IMPROPER INSTALLATION, INADEQUATE FASTENERS, COLOR MATCHINGCONCERNS & IMPROPER MATERIAL USAGE.REMOVE AND REPLACE BOARD SHEETING AS NEEDED. REMOVE ANY SUBSTRATETHAT IS NOT CDX PLYWOOD. ALL OSB TO BE REMOVED AND PREPPED FORREPLACEMENT WITH NEW CDX PLYWOOD.REMOVE ALL BOARD AND BATTEN, PREP FOR NEW MATERIAL TBD AND FLASHINGNCS TEAMOne Towne SquareSuite 150Southfield, MI 48076Tel: 989-992-6179www.ncs-team.comJosh@NCS-Team.comREMOVE ALL CURRENTROOFING & OSB, CDX ASLONG AS NOT DAMAGEDCAN REMAINREMOVE SIDING PREPFOR NEW SOFFIT BOXOUTTO MATCH ADJACENTALTERNATE PRICE TOREMOVE & REPLACEWINDOWSREMOVE BOARD & BATTEN SIDINGPREP FOR NEW MATERIALDEMOLITION SOUTH ELEVATION OF SOUTH WINGSCALE: 1/4" = 1'-0"REMOVE WINDOW PREPFOR NEW WINDOWISSUED FOR:BID PACK 110-06-25PERMIT11-21-25SEAL:SHEET#DATE:A-1.210-06-25REMOVE ALL BOARD &BATTEN SIDING, PREPFOR NEW MATERIAL TBDREMOVE OVERHEADDOOR AND FRAMEREMOVE BRICK TOSIDING FOR NEW DOORREMOVE ALL CURRENTROOFING & OSB, CDX ASLONG AS NOT DAMAGEDCAN REMAINREMOVE DOOR & STEP PREPFOR NEW STOREFRONTDOOR & STEPARCHITECT:Scheible &AssociatesL.L.C.46 Kensington Blvd.Pleasant Ridge, MI 48069(248) 797-9890scheibleassociates.comDRAWN BY:DEMOLITION EAST ELEVATIONSCALE: 1/4" = 1'-0"NCS TEAMOne Towne SquareSuite 150Southfield, MI 48076Tel: 989-992-6179www.ncs-team.comJosh@NCS-Team.comDEMOLITION NOTES:REMOVE ENTIRE METAL ROOF, J-TRIM & FACIA PREP FOR RE-INSTALLATION DUETO IMPROPER INSTALLATION, INADEQUATE FASTENERS, COLOR MATCHINGCONCERNS & IMPROPER MATERIAL USAGE.REMOVE AND REPLACE BOARD SHEETING AS NEEDED. REMOVE ANY SUBSTRATETHAT IS NOT CDX PLYWOOD. ALL OSB TO BE REMOVED AND PREPPED FORREPLACEMENT WITH NEW CDX PLYWOOD.REMOVE ALL BOARD AND BATTEN, PREP FOR NEW MATERIAL TBD AND FLASHINGREMOVE ALL CURRENTROOF & STRUCTUREFOR NEW STRUCTURE &FUTURE SHED ROOFREMOVE ALL BOARD &BATTEN SIDING, PREPFOR NEW MATERIAL TBDEXISTINGLETTERING TOREMAIN AS ISGARDEN CITYFIRE DEPARTMENTREMOVE CIRCUIT &INFILL WITH BRICK.REMOVE PREVIOUSMOUNTING HARDWAREDEMOLITION WEST ELEVATIONSCALE: 1/4" = 1'-0"REMOVE ALL CURRENTROOFING & OSB, CDX ASLONG AS NOT DAMAGEDCAN REMAINREMOVE ALL CURRENTROOF & STRUCTUREFOR NEW STRUCTURE &FUTURE SHED ROOFISSUED FOR:BID PACK 110-06-25REVISION 111-19-25PERMIT11-21-25SEAL:SHEET#DATE:A-1.310-06-25
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Sidewalk Repairs - Multiple L...
Solicitation: BID 6582 Description: Sidewalk Repairs - Multiple Locations >> Specification Solicitation Date/Time:
Kent County
Bid Due: 7/16/2026
Description: Design Build Services Department: Hemlock Public Schools Buyer: Denise Dowdell Solicitation Number:
State of Michigan
Bid Due: 7/15/2026