Dena'ina Convention Center Dock Leveler Upgrades
Project Information
- Bid Title
- Dena'ina Convention Center Dock Leveler Upgrades
- Issuing Agency
- City of Anchorage
- Location
- Alaska
- Published Date
- Jan 22, 2026
- Closing Date
- Feb 19, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- 2026C003
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
+2026C003 Dena'ina Convention Center Dock Leveler UpgradesClick here to be added to the plan holders list Click here to view the plan holders list Click here to submit a question(s) on this bid solicitationProject SummaryInvitation to BidDrawingsAddendumsOther DocumentsBid AbstractResponsible Bidder
- Attachment Preview
-
PROJECT LOCATIONVICINITY MAPDENA'INA CONVENTION CENTERDOCK LEVELER UPGRADESOWNERMUNICIPALITY OF ANCHORAGEMAINTENANCE & OPERATIONS DEPARTMENT3640 E TUDOR ROAD, WAREHOUSE NO. 1ANCHORAGE, ALASKA 99507PROJECT MANAGER: TRAVIS O'ROURKET. 907.343.8256STRUCTURAL AND ELECTRICAL ENGINEERSCOFFMAN ENGINEERS, INC800 F STREETANCHORAGE, ALASKA 99501T. 907.276.6664F. 907.276.5042800 F StreetAnchorage, AK 99501ph 907.276.6664www.coffman.comCOFFMAN PROJECT NO. 231027AECC249PROJECT LOCATIONPROJECT LOCATIONPROJECT ADDRESS: 600 W. 7TH AVE. ANCHORAGE, AK 99501SHEET NUMBERDRAWING TITLEGENERALG-001COVER SHEETSTRUCTURALS-001STRUCTURAL GENERAL NOTESS-501DEMOLITION DETAILSS-502INSTALLATION DETAILSS-601REBAR DETAILSE-100ELECTRICAL/INSTRUMENTATIONELECTRICAL LEGEND, ABREVIATIONS, AND PLANE-200ELECTRICAL RISER AND PANEL SCHEDULEE-300ELECTRICAL SPECIFICATIONSREV STATUS1 IFC1 IFC1 IFC1 IFC1 IFC1 IFC1 IFC1 IFCSCOPE OF WORK OVERVIEW:1. INSTALL TWO REPLACEMENT AND TWO NEW MOTOR OPERATEDLOADING DOCK LEVELERS. NEW PITS WILL BE CONSTRUCTED FORNEW LOADING DOCK LEVELERS.2. INSTALL NEW DOCK LEVELERS AND ASSOCIATED CONTROLPANELS AND DISCONNECTS. DOCK LEVELERS AND CONTROLPANELS WILL BE PROCURED BY CONTRACTOR. THE DOCKLEVELER BASIS OF DESIGN IS THE SERCO HFC8740-20 WITHOPTIONAL 20" LIP, ENERGY GUARD WEATHERSEAL SYSTEM, ANDVB620-11 BUMPERS.3. INSTALL POWER AND CONTROL WIRING FOR THE NEW LOADINGDOCK LEVELERS.G-001STRUCTURAL NOTES:THE FOLLOWING NOTES APPLY UNLESS INDICATED OTHERWISE:CODES AND STANDARDSALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL CONFORM TO THEREQUIREMENTS OF THESE DRAWINGS, INTERNATIONAL BUILDING CODE (IBC) 2018EDITION AND ASCE 7-16 "MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FORBUILDINGS AND OTHER STRUCTURES" AS ADOPTED BY THE MUNICIPALITY OFANCHORAGE.DESIGN LOADSRISK CATEGORY IIWINDBASIC WIND SPEEDEXPOSURE CATEGORYIMPORTANCE FACTORTOPOGRAPHIC FACTORDIRECTIONALITY FACTORGROUND ELEVATION FACTORGUST FACTORENCLOSURE CLASSIFICATIONV = 145 MPHEXSPOSURE BIw = 1.0Kzt = 1.0Kd = 0.85Ke = 1.0G = 0.85ENCLOSEDSEISMICSPECTRAL ACCEL., SHORTSPECTRAL ACCEL., 1.0 SECDESIGN SPECTRAL ACCEL., SHORTDESIGN SPECTRAL ACCEL., 1.0 SECIMPORTANCE FACTORSITE CLASSSEISMIC DESIGN CATEGORYSs = 1.5S1 = 0.679Sds = 1.2Sd1 = 0.770Ie = 1.0D, ASSUMEDDSCOPE1. COORDINATE REMOVAL OF EXISTING DOCK LEVELERS WITH VENDOR.SHORTEN EXISTING DOCK LEVELER PITS LOCATED AT DOCKS 3 AND 4.CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF DOCK LEVELERSAND ASSOCIATED EQUIPMENT.2. DEMOLISH FLOOR SLAB AT DOCKS 2 AND 5 TO ALLOW FOR PLACEMENT OFNEW DOCK LEVELER PITS. SCAN FOR EXISTING CONDUIT BEFOREDEMOLITION.3. CUT A TRENCH IN THE CONCRETE SLAB ON GRADE FROM THE JUNCTIONBOX TO THE DOCK LEVELER PITS TO ROUTE CONDUIT FOR OPERATION OFNEW DOCK LEVELERS. SCAN FOR EXISTING CONDUIT BEFORE DEMOLITION.4. REMOVE AND REPLACE EXISTING BUMPERS.5. INSTALL (4) NEW DOCK LEVELERS PER MANUFACTURER INSTRUCTIONS.GENERALREFERENCE STANDARDS:REFER TO CHAPTER 35 OF THE IBC. WHERE OTHER STANDARDS ARE NOTED INTHE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFICDATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE DOES NOTRELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD.SITE VERIFICATION:THESE DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OFCONSTRUCTION SHALL BE USED, SUBJECT TO THE REVIEW AND APPROVAL OF THEOWNER'S REPRESENTATIVE.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE.CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITION SHALL BEBROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE BEFOREPROCEEDING WITH THE WORK.GENERAL CONTRACTOR NOTES:THE GENERAL CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIESAND STRUCTURES AFFECTING THE WORK. NOTIFY THE OWNER'S REPRESENTATIVEIN WRITING OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND WHAT ISSHOWN IN THE CONTRACT DOCUMENTS WHICH WILL ADVERSELY AFFECT THEWORK.THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SHORINGREQUIRED FOR INSTALLATION OF ALL COMPONENTS OF THE CONTRACT. THECONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THEMETHODS, TECHNIQUES, AND SEQUENCES OF PROCEDURES REQUIRED TOPERFORM THE WORK. THE CONTRACTOR SHALL COORDINATE ALL TRADES ANDVERIFY DIMENSIONS IN THE FIELD.ANY DAMAGE DONE DURING INSTALLATION/DEMOLITION NOT INCLUDED IN THEPROJECT SCOPE SHALL BE REPAIRED IN KIND USING REASONABLE MEANS ANDMETHODS AT NO ADDITIONAL COST TO THE OWNER.SOILS:CONTRACTOR SHALL REUSE IN-SITU SOIL UNDER EXISTING CONCRETE. COMPACT TO95% MAXIMUM DENSITY AND SHORE AS REQUIRED BEFORE PLACEMENT OF CAST-INCONCRETE.CAST-IN-PLACE CONCRETEREINFORCING STEEL:ALL REINFORCING STEEL SHALL CONFORM TO ACI AND ASTM SPECIFICATIONS ASFOLLOWS:DEFORMED BARSASTM A615, GRADE 60BAR SUPPORTS SHALL BE PER CRSI MSP-09 28TH EDITION, CHAPTER 3 "BARSUPPORTS." TIE WIRE SHALL BE 16 GAGE OR HEAVIER, BLACK ANNEALED WIRE.PROVIDE #5 CONTINUOUS RISER BARS TO SUPPORT ALL SLAB AND FOOTINGREINFORCEMENT. REINFORCING STEEL SHOP DRAWINGS SHALL BE PREPARED BY ANEXPERIENCED DETAILER CONFORMING TO STANDARD PRACTICE OUTLINED IN ACIREPORT 315.LAP ALL REINFORCING WITH CLASS B LAP SPLICE PER ACI 318.CONTRACTOR SHALL SUBMIT REINFORCING STEEL SHOP DRAWINGS FOR REVIEWPRIOR TO FABRICATION.MECHANICAL ANCHORSCONCRETE EXPANSION ANCHORS SHALL BE HILTI KWIK BOLT TZ2 ESR-4266 ORAPPROVED EQUAL.DRILLING SHALL BE PERFORMED WITH A ROTARY HAMMER DRILL AND CARBIDE TIPPEDDRILL BIT IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THEAPPLICABLE ICC EVALUATION REPORT.BORE HOLE CLEANING PROCEDURES MUST COMPLY WITH THE MANUFACTURER'SINSTRUCTIONS AND THE APPLICABLE ICC EVALUATION REPORT IN ORDER TO PRODUCEA DRY, DUST-FREE HOLE.EPOXY ANCHORS AND DOWELS:DRILLED-IN EPOXY DOWELS SHALL BE STEEL REINFORCEMENT AND EMBEDMENT PERTHE STRUCTURAL DRAWINGS. HOLE DRILLING, EPOXY INJECTION, AND DOWELPLACEMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. EPOXYSHALL BE "HIT-RE 500SD" ADHESIVE ANCHOR SYSTEM FOR CONCRETE BY HILTIFASTENER SYSTEMS. "SET-XP" BY SIMPSON STRONG-TIE CO., "PURE110+" BY DEWALT,OR APPROVED EQUIVALENT. ICC CERTIFICATION REQUIRED.CONCRETE:MATERIALS AND WORKMANSHIP SHALL CONFORM TO ACI, AND ASTM SPECIFICATIONSAS FOLLOWS:COMPRESSIVE STRENGTHASTM C39; 4000 PSI AT 28 DAYS.MAX AGGREGATE SIZE1"CEMENTWATERWATER/CEMENT RATIOASTM C150; TYPE I, II, OR IIIPOTABLE.0.45 MAXIMUM BY WEIGHT.CONTRACTOR SHALL SUBMIT MIX DESIGN(S) FOR REVIEW PRIOR TO MATERIALPURCHASE.CONTRACTOR SHALL APPLY A HARD TROWEL FINISH TO CONCRETE SURFACE.CONCRETE COVER:CONFORM TO THE FOLLOWING COVER REQUIREMENTS UNLESS NOTED OTHERWISE INTHE DRAWINGS.CONCRETE CAST AGAINST EARTH3"CONCRETE EXPOSED TO EARTH OR WEATHER2"CONCRETE NOT EXPOSED TO EARTH OR WEATHER 1.5"BONDING AGENTCONCRETE BONDING AGENT SHALL CONFORM TO ASTM C1059 AND BE APPLIED TOHARDENED CONCRETE SURFACE PRIOR TO POURING OF NEW CONCRETE PER VENDORRECOMMENDATIONS.STRUCTURAL STEELMATERIALSSTEEL:ANGLESHSSASTM A36, FY = 36 KSI, HOT-DIPGALVANIZEDASTM A500 GR. B OR C HOT-DIPGALVANIZEDFABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH AISC SPECIFICATIONS.STRUCTURAL STEEL, MISCELLANEOUS STEEL, METAL FABRICATIONS, AND STEELFASTENERS SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM A123 OR A153AS APPLICABLE.STRUCTURAL STEEL WELDING:ALL STRUCTURAL WELDING SHALL BE PRE-QUALIFIED AND CONFORM TO AISC AND AWSSPECIFICATIONS AS FOLLOWS:WELDERSCERTIFIED FOR ROD AND POSITIONELECTRODESSMAW-E70XX; HEAVY COATED; LOW HYDROGENFCAW-E70XX; LOW HYDROGENMINIMUM WELDCONT. FILLET PER AISC TABLE J2.4ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS HAVING CURRENTCERTIFICATES AND EXPERIENCE IN THE TYPE OF WELD BEING PERFORMED. WELDINGCERTIFICATES SHALL BE THOSE ISSUED BY AN ACCEPTED TEST AGENCY. ALL WELDINGSHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AWS D1.1. USE E70 SERIESLOW HYDROGEN ELECTRODES STORED AND MAINTAINED IN DRY CONDITION PER AWS.GROUTGROUT - 5000 PSI MINIMUM 7-DAY CUBE STRENGTH. GROUT TO BE PREMIXED,NON-METALLIC, NON-SHRINK. ICBO CERTIFICATION REQUIRED. USE SPECIFIC GROUTMIX RECOMMENDED BY MANUFACTURER FOR EACH GROUT APPLICATION AND FOLLOWMANUFACTURER'S INSTRUCTIONS.SUBMITTALSSUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TOTHE OWNER'S REPRESENTATIVE AND SHALL BE REVIEWED FOR GENERALCONFORMANCE WITH THE DRAWINGS. SUBMITTAL ITEMS SHALL NOT BE FABRICATEDOR INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVEDBY THE OWNER'S REPRESENTATIVE.SUBMITTAL ITEMS INCLUDE:1. CONCRETE MIX DESIGN2. REBAR SHOP DRAWINGS3. WELDING CERTIFICATIONS4. DOCK LEVELER MANUFACTURER DATA SHEETSCONSTRUCTION NOTES1. REMOVE DELAMINATED OR DETERIORATED CONCRETE UNTIL SOLID CONCRETEIS ENCOUNTERED.2. CHECK SURFACES TO ENSURE THEY ARE FREE FROM LOOSE AGGREGATE ORADDITIONAL DELAMINATIONS OR SPALLINGS.3. EXPOSED REINFORCING BARS SHALL BE CLEANED OF SCALE, RUST, DIRT, OIL,AND OTHER DELETERIOUS MATERIAL.4. FORMS SHALL BE WATER TIGHT.5. AT INTERFACES BETWEEN EXISTING AND NEW CONCRETE, ROUGHEN EXISTINGSURFACE TO 1/4" AMPLITUDE MINIMUM. CLEAN AND APPLY BONDING AGENT TOROUGHENED CONCRETE SURFACE IMMEDIATELY BEFORE CASTING NEWCONCRETE.1S-501EXTENTS OF WORK1 OVERALL PROJECT LAYOUTS-001 SCALE: 1/32"=1'-0"NORTHSPECIAL INSPECTIONSTHE FOLLOWING SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITHIBC 1705 BY QUALIFIED PERSONNEL EMPLOYED BY THE MOA. THE CONTRACTORSHALL COORDINATE WORK WITH SPECIAL INSPECTORS.SOILS AND FOUNDATIONS:PREPARATION OF SUBGRADE PRIOR TO COMPACTED FILL - PERIODICCONCRETE:CONCRETE REINFORCING - PERIODICDRILLED IN ANCHORS AND DOWELS - CONTINUOUSMECHANICAL ANCHORS - PERIODICSAMPLING OF CONCRETE FOR COMPRESSIVE STRENGTH, SLUMP & AIR TESTS -CONTINUOUSSTEEL CONSTRUCTION:FIELD WELDING - PERIODIC, VISUALEQUIPMENT:DOCK LEVELER INSTALLATION - PERIODICABBREVIATIONS:BOTBOTTOMCLRCLEARCONCCONCRETECOORDCOORDINATEDEMODEMOLISH OR DEMOLITION(E)EXISTINGEWEACH WAYHORHORIZONTALMINMINIMUMMOAMUNICIPALITY OFANCHORAGENTDNON-DESTRUCTIVETESTINGNTSNOT TO SCALEO.C.RREINFSTDTYPT&BVERTVIFW/ON CENTERRADIUSREINFORCE ORREINFORCEMENTSTANDARDTYPICALTOP AND BOTTOMVERTICALVERIFY IN FIELDWITHMATTHEW C. STIELSTRANov 15, 2023TEREDNo. SE 13701PROFESSIONALENGIDateDesignDrawnJob No.Sheet No.11/2023BMHMCS231027S-001DOCK 2(E) L3x3x1/4, TYP(E) DOCKLEVELER PIT7'-5" VIFDOCK 3(E) L3x3x1/4, TYP(E) DOCKLEVELER PIT7'-5" VIFDOCK 4DOCK 5NOTE:1. LOCATE TRENCH BELOW DOCK LEVELER CONTROL PANEL.CONTRACTOR TO CONDUCT GROUND PENETRATING RADAR (GPR)SCAN OR OTHER APPROVED NDT TO LOCATE EXISTING CONDUIT.COORDINATE WITH ELECTRICAL CONTRACTOR TO PERFORMDEMOLITION WITHOUT DISTURBING EXISTING CONDUIT.2. CONTRACTOR TO SHORE SOIL AS REQUIRED DURING DEMO.3. SELECTIVE DEMOLITION 9" PAST DOCK LEVELER PIT SIDE WALLS ONEACH SIDE OF DEMO AREA. HORIZONTAL REINFORCEMENT TOREMAIN.1 EXISTING DOCK PLANS-501 SCALE: 1/8"=1'-0"NORTHCAUTION! ESTIMATED ROUTINGOF EXISTING SECURITY WIRING.SEE NOTE 1.4-(2) 1-1/2"Øx12" HOLES FORCONDUIT PER SECTION6'-10"4-7'-5" VIF6S-5022 DOCK 3&4 DEMOLITION PLANS-501 SCALE: 3/8" = 1'-0"DEMO 12"x15-3/8"CONDUIT TRENCHPER ELECTRICAL.SEE NOTE 1.(E) WALL VIFCAUTION! ESTIMATED ROUTINGOF EXISTING SECURITY WIRING.SEE NOTE 1.4/5-6'-10"6S-502DEMO 12"x16"CONDUIT TRENCHPER ELECTRICAL.SEE NOTE 1.(E) WALL VIFPROPOSEDPIT WALL8'-0"EXTENTS OF DEMO,CENTERED INDOORWAY. SEESECTION(E) BOLLARD TO REMAIN TYP (OF 2)(E) WALL TO REMAIN TYP (OF 2). SEE NOTE 3.3 DOCK 2&5 DEMOLITION PLANS-501 SCALE: 3/8" = 1'-0"7'-5"EXTENTS OF NEW WALL. REINFNOT SHOWN FOR CLARITY.2"11"DRILL 1-1/2"Ø HOLES TOTRENCH FOR CONDUIT.COORD. W/ ELECTRICAL.4 TYPICAL CONDUIT PENETRATIONS-501 SCALE: 1" = 1'-0"9"7'-3" TO PROPOSED WALL(E) FLOOR SLABMATTHEW C. STIELSTRANov 15, 2023TEREDNo. SE 13701PROFESSIONALENGI(E) REINF, TYPEXTENTS OFDEMONOTE 2EXTENTS OFPROPOSED DOCKLEVELER PIT1'-0" VIF(E) WALL5 DOCK 2&5 DEMOLITION SECTIONS-501 SCALE: 1" = 1'-0"0123463/8"=1'-0"0121"=1'-0"DateDesign11/2023BMHDrawnMCSJob No.8231027Sheet No.3S-501#4 DOWEL 4" EPOXY EMBED EACH END3-#4 HOOKS 4" EPOXY EMBED W/STD HOOKS, 12" O.C., TYP7'-5"6- TYP7'-5" VIF5-365-36SEE NOTE 4CONDUIT TRENCH BEYONDCONDUIT HOLES, TYPSLAB REINF NOT SHOWNNOTE:1. CONTRACTOR TO SHORE RETAINED SOIL AS REQUIRED.2. L3x3x1/4 CORNER REINFORCEMENT SHALL BE WELDED WITH 1/4"SEAM WELDS.3. CUT OFF BOLTS FLUSH WITH WALL OR GROUT HOLES THAT CAN NOTBE REUSED FOR NEW BUMPER ANCHORS.4. WELD DOCK LEVELER TO CORNER REINFORCEMENT/HSS SPACERPER VENDOR WRITTEN RECOMMENDATIONS.WELD HSS2x2x1/4 FLUSH W/L3x3x1/4 CORNER REINFPER SECTION5-1 DOCK 3&4 INSTALLATION PLANS-502 SCALE: 1/2" = 1'-0"#4 DOWEL 4" EPOXY EMBED#4 DOWEL 4" EPOXY EMBED EACH END#4 HOOKS 4" EPOXY EMBED W/STD HOOKS, 12" O.C., TYP4-8'-0"6- TYPEPOXY EMBED 6" BOTHENDS PER SECTION.ONLY ONE HOR REINFSHOWN FOR CLARITY.NOTE 4#5 REINF PER SECTIONREUSE (E) BOLLARD, TYP (OF 2)INSTALL L3x3x1/4CORNER REINF PERSECTION. SEE NOTE 2.4 SIM-7'-3"5-2 DOCK 2&5 INSTALLATION PLANS-502 SCALE: 1/2" = 1'-0"3 DOCK 3&4 INSTALLATION SECTIONS-502 SCALE: 1" = 1'-0"#5 DOUBLE HOOK W/ STDHOOK AND 6" EPOXYEMBED, @12" O.C.9"7'-3" TO PROPOSED WALLINSTALL NEW L3x3x1/4CORNER REINF W/1/2"Øx6" STUD @12" O.C.,SEE NOTE 4.#5 VERT @12"O.C.2" CLR#5 RODS EPOXY6" INTO FLOORSLAB EACHEND, TYP (OF 6).SEE PLAN2" CLRFILL DEMOLISHEDAREAS WITH CONC.SEE NOTE 1.1'-0" VIF#5 STD HOOK @12"O.C., 8" EPOXY EMBEDINTO (E) WALL#5 HOR REINF@12" O.C. EW T&B4 DOCK 2&5 INSTALLATION SECTIONS-502 SCALE: 1" = 1'-0"CONCRETEFLOOR +0'-00"DOCK LEVELERPIT -1'-8"7'-1"L3x3X1/4 CORNER REINF PER SECTION. SEE NOTE 23/4"Øx4" MIN EMBED EXPANSION ANCHOR, TYP (OF 8).SEE NOTE 3.REMOVE AND REPLACE (E) BUMPERS W/VB620-11 BUMPER.5 TYPICAL DOCK LEVELER ELEVATIONS-502 SCALE: 1" = 1'-0"#4 HOOKBEYOND1'-0"±#4 REINF PERPLAN#4 HOOKCENTERED INSLAB PER PLANDEMO CONC ANDREMOVE SOIL ANDREPLACE IN KIND.CONDUIT PERELECTRICAL6 TYPICAL CONDUIT TRENCHS-502 SCALE: 1-1/2" = 1'-0"MATTHEW C. STIELSTRANov 15, 2023TEREDNo. SE 13701PROFESSIONALENGI6"VB620-11 BUMPERPER VENDOR3"INSTALL3/4"x4-1/4"7-EXPANSIONANCHOR TYP(OF 8)7 TYPICAL BUMPER SECTIONS-502 SCALE: 1-1/2" = 1'-0"012461/2"=1'-0"01231"=1'-0"06"1'2'1 1/2"=1'-0"DateDesignDrawnJob No.Sheet No.11/2023BMHMCS231027S-502NORMAL WT.CONCRETEf'c (psi)4000450050004000450050000.375"#3TB2419231822170.375"#3TB191518141713SPLICE OR DEVELOPMENT LENGTH (INCHES)0.500"#4TB3225312329220.500"#4TB2419231822170.625"#5TB4031382936280.625"#5TB312429232822"CLASS B" TENSION LAP SPLICE SCHEDULE0.750"0.875"1.000"#6#7#8TBTBTB483770548162463566517658433363497255DEVELOPMENT LENGTH "Ld" SCHEDULE0.750"0.875"1.000"#6#7#8TBTBTB3729544262483527513958453326493755431.128"#9TB9070856681621.128"#9TB7053655162481.270"#10TB10177957390691.270"#10TB7760735669531.410"#11TB111851048099761.410"#11TB856680627659NOTES:1. SCHEDULE APPLIES TO UNCOATED GRADE 60 BARS IN NORMAL WEIGHT CONCRETE.2. ALL SPLICES SHALL BE CLASS B SPLICES UNLESS INDICATED OTHERWISE.3. TOP BARS (INDICATED WITH "T" IN SCHEDULE) ARE HORIZONTAL TOP BARS WITH MORE THAN 12" OF CONCRETE CAST BELOW THE BARS.4. BOTTOM BARS (INDICATED WITH "B" IN SCHEDULE) ARE ALL VERTICAL BARS AND HORIZONTAL BARS WITH LESS THAN 12" OF CONCRETECAST BELOW HORIZONTAL BARS.5. ANY PORTION OF A STRAIGHT BAR EMBEDMENT LENGTH NOT WITHIN THE CONFINED CORE SHALL BE INCREASED BY A FACTOR OF 1.6.6. ALL HORIZONTAL SPLICES SHALL BE STAGGERED AS SHOWN. IF MORE THAN 50% OF VERTICAL REINFORCING IS LAP SPLICED WITHINTHE REQUIRED LAP SPLICE LENGTH. THE LAP SPLICE LENGTH SHALL BE INCREASED BY 33%.7. LAP SPLICES LISTED IN THE SCHEDULE ARE CLASS B LAPS, FOR CLASS A LAPS REDUCE LENGTH BY 25%.Ld12" MINLd1 1/2" ORWIRED IN CONTACTLdTOP REINFSLOPE 1:12MAX, TYPLdBOT REINFHOOKED DOWEL DEVELOPMENT LENGTHS INTENSION (INCHES)BAR SIZE#3#4#5#6#7#8#9#10#114000 PSICONCRETE81012151719222427EMBEDMENT4500 PSICONCRETE79111416182023255000 PSICONCRETE7911131517192224EXTENSION90° HOOK4.5180°HOOK2.56.02.57.52.59.03.010.53.512.04.013.54.515.05.016.55.5NOTES:1. DEVELOPMENT LENGTH IS BASED ON 2 1/2" MINIMUM SIDE COVER AND 2" MINIMUM END COVER.2. INCREASE EMBEDMENT LENGTHS BY 20% FOR EPOXY COATED BARS.MINIMUM DIAMETER OFBEND (INCHES)2.253.03.754.55.256.09.010.011.0DIAMETEROF BENDEMBEDMENTDIAMETEROF BENDEMBEDMENT90° HOOKEXTENSION180° HOOKMATTHEW C. STIELSTRANov 15, 2023TEREDNo. SE 13701PROFESSIONALENGDateDesignDrawnJob No.Sheet No.11/2023BMHMCS231027S-601
- Commodity Codes
-
- NAICS 238290Other Building Equipment Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
USCG REGIONAL MULTIPLE AWARD ...
Follow USCG REGIONAL MULTIPLE AWARD CONSTRUCTION CONTRACT (RMACC III) Active Contract Opportunity Notice
HOMELAND SECURITY, DEPARTMENT OF
Bid Due: 12/31/2026
ITB-26-15 Moore Street Senior...
Title Posted Date Closing Date ITB-26-15 Moore Street Senior Apartments Parking Lot Improvements
City of Fairbanks
Bid Due: 7/22/2026