BID#1973?MDUSD 2026?Roofing Project - Holbrook Language Academy and Valle Verde Elementary School Addendum 1
Project Information
- Bid Title
- BID#1973?MDUSD 2026?Roofing Project - Holbrook Language Academy and Valle Verde Elementary School Addendum 1
- Issuing Agency
- Mt. Diablo Unified School District
- Location
- California
- Published Date
- Mar 11, 2026
- Closing Date
- Mar 17, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
BID#1973 MDUSD 2026 Roofing Project - Holbrook Language Academy and Valle Verde Elementary SchoolOPEN FOR BIDDING. Bids Due March 17, 2026 at 10:00 a.m.
- 1973 BID Addendum 1
- 1973 BID Mandatory Walk SignIn Sheet
- 1973 BID Volume 1
- 1973 BID Volume 2
- 1973 BID Drawings-Holbrook
- 1973 BID Drawings-Valle Verde ES
- Attachment Preview
-
PURCHASING & WAREHOUSE DEPARTMENT2326 Bisso Lane, Concord, California 94520BID #19732026 Roofing Project -Holbrook and Valle VerdeElementary SchoolsFORMT. DIABLO UNIFIED SCHOOL DISTRICTADDENDUM #1DOCUMENT 00 91 13ADDENDA03/10/2026NOTICE TO ALL BIDDERS: THE FOLLOWING MODIFICATIONS, ADDITIONS, DELETIONS, CLARIFICATIONSAND/OR INFORMATION ARE HEREBY MADE PART OF THE CONTRACT DOCUMENTS. ADDENDUM MUSTBE ACKNOWLEGDED AS PART OF THE BIF FORM.(1) CHANGES TO TECHNFICAL SPECIFICATIONS (attached)(a) 07.55.00 – Modified Bituminous Roofing – Removed and replaced(2) BID QUESTIONS (RFI’s)(a) What is the engineer’s estimate for this project?(i) $4,400,000.00(b) What is the warranty/Maintenance period?(i) 5-year craftsmanship warranty as outlined in Article 1 of the technical spec section,07.55.00-Modified Bituminous Roofing.(c) Do we need to prequalify through Quality Bidders if we are submitting a bid as a C-39roofing Contractor?(i) Per Instruction to Bidders; all prime bidders are required to prequalify prior to submittinga bid to MDUSD.Mt. Diablo Unified School DistrictADDENDUM #1AddendaDOCUMENT 00 91 13 12026 Roof Package #2 – Valle Verde ES and Holbrook Language AcademyMt. Diablo Unified School DistrictSECTION 07550MODIFIED BITUMINOUS MEMBRANE ROOFINGPART 1 GENERAL1.1 SECTION INCLUDESA. Includes all labor, non-owner supplied materials, and equipment to install a modified bitumenroof system over the properly prepared substrate.B. Includes removal and disposal of existing roofing system(s), insulation board, gutters,downspouts (schedule 40 to remain), flashings, counter flashings, sheet metal items,copings, expansion joints, etc. for a complete prepared roof surface to receive the newroofing system.C. Includes a new hot applied 2-ply asphalt roofing system with all accessories as needed for acomplete warrantable roofing system.D. Includes testing of all drains and downspouts before construction and after construction toensure proper drain performance.1.2 RELATED SECTIONSA. Section 01640 – Owner Furnished MaterialB. Section 07220 – Roof Deck InsulationC. Section 07620 - Sheet Metal Flashing and Trim1.3 REFERENCESA. ASTM D 41 - Standard Specification for Asphalt Primer Used in Roofing, Dampproofing, andWaterproofing.B. ASTM D 312 - Standard Specification for Asphalt used in Roofing.C. ASTM D 451 - Standard Test Method for Sieve Analysis of Granular Mineral Surfacing forAsphalt Roofing Products.D. ASTM D 1079 Standard Terminology Relating to Roofing, Waterproofing and BituminousMaterials.E. ASTM D 1863 Standard Specification for Mineral Aggregate Used as a Protective Coatingfor Roofing.F. ASTM D 2178 Standard Specification for Asphalt Glass Felt Used in Roofing andWaterproofing.G. ASTM D 2822 Standard Specification for Asphalt Roof Cement.H. ASTM D 4601 Standard Specification for Asphalt Coated Glass Fiber Base Sheet Used inRoofing.I. ASTM D 5147 Standard Test Method for Sampling and Testing Modified Bituminous SheetMaterials.J. ASTM D 6162 Standard Specification for Styrene Butadiene Styrene (SBS) Modified07550-1 ADDENDUM #12026 Roof Package #2 – Valle Verde ES and Holbrook Language AcademyMt. Diablo Unified School DistrictBituminous Sheet Materials Using a Combination of Polyester and Glass FiberReinforcements.K. ASTM E 108 - Standard Test Methods for Fire Test of Roof CoveringsL. Factory Mutual Research (FM): Roof Assembly Classifications.M. National Roofing Contractors Association (NRCA): Roofing and Waterproofing Manual.N. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA) -Architectural Sheet Metal Manual.O. Underwriters Laboratories, Inc. (UL): Fire Hazard Classifications.P. Warnock Hersey (WH): Fire Hazard Classifications.Q. ANSI-SPRI ES-1 Wind Design Standard for Edge Systems used with Low Slope RoofingSystems.R. ASCE 7, Minimum Design Loads for Buildings and Other StructuresS. UL - Fire Resistance Directory.T. FM Approvals - Roof Coverings and/or RoofNav assembly database.U. California Title 24 Energy Efficient Standards.1.4 DESIGN / PERFORMANCE REQUIREMENTSA. Perform work in accordance with all federal, state and local codes.B. Exterior Fire Test Exposure: Roof system shall achieve a UL, FM or WH Class rating for roofslopes indicated on the Drawings as follows:1. Factory Mutual Class A Rating.2. Underwriters Laboratory Class A Rating.3. Warnock Hersey Class A Rating.C. Design Requirements:1. Uniform Wind Uplift Load Capacitya. Installed roof system shall withstand negative (uplift) design wind loadingpressures complying with the following criteria.1) Design Code: ASCE 7, Method 2 for Components and Cladding.2) Importance Category:a) III.3) Importance Factor of:a) 1.04) Wind Speed: 115 mph5) Ultimate Pullout Value: 364 pounds per each of the fastener6) Exposure Category:a) B.7) Roof Pitch: 0.5 :12.8) Roof Area Design Uplift Pressure:a) Zone 1 - Field of roof 14.3 psfb) Zone 2 - Eaves, ridges, hips and rakes 24 psfc) Zone 3 - Corners 36 psf2. Live Load: 20 psf, or not to exceed original building design.3. Dead Load:a. Installation of new roofing materials shall not exceed the dead load capacity of07550-2 ADDENDUM #12026 Roof Package #2 – Valle Verde ES and Holbrook Language AcademyMt. Diablo Unified School Districtthe existing roof structure.D. Energy Star: Roof System shall comply with the initial and aged reflectivity required by theU.S. Federal Government's Energy Star program.E. LEED: Roof system shall meet the reflectivity and emissivity criteria to qualify for one pointunder the LEED credit category, Credit 7.2, Landscape & Exterior Design to Reduce HeatIsland - Roof.F. Roof System membranes containing recycled or bio-based materials shall be third partycertified through UL Environment.G. Roof system shall have been tested in compliance with the following codes and testrequirements:1. Cool Roof Rating Council:a. CRRC Directory CRRC 077-00282. International Code Council Evaluation Service (ICC-ES):a. Membrane Systems1) ESR3. Underwriters Laboratories:a. Certification TGFU.R4. Warnock Herseya. ITS Directory of Listed Products5. FM Approvals:a. RoofNav Website1.5 SUBMITTALSA. Submit under provisions of Section 01300.B. Product Data: Manufacturer's data sheets on each product to be used, including:1. Preparation instructions and recommendations.2. Storage and handling requirements and recommendations.3. Installation instructions.C. Shop Drawings: Submit shop drawings including installation details of roofing, flashing,fastening, insulation and vapor barrier, including notation of roof slopes and fasteningpatterns of insulation and base modified bitumen membrane, prior to job start.D. Design Pressure Calculations: Submit design pressure calculations for the roof area inaccordance with ASCE 7 and local Building Code requirements. Include a roof systemattachment analysis report, certifying the system's compliance with applicable wind loadrequirements before Work begins. Report shall be signed and sealed by a ProfessionalEngineer registered in the State of the Project who has provided roof system attachmentanalysis for not less than 5 consecutive years.E. LEED Submittals: Provide documentation of how the requirements of Credit will be met:1. List of proposed materials with recycled content. Indicate post-consumer recycledcontent and pre-consumer recycled content for each product having recycled content.2. Product data and certification letter indicating percentages by weight of post-consumer and pre-consumer recycled content for products having recycled content.3. Product reflectivity and emissivity criteria to qualify for one point under the LEEDcredit category, Credit 7.2, Landscape & Exterior Design to Reduce Heat Island -Roof.F. Recycled or Bio-Based Materials: Provide third party certification through UL Environment ofroof System membranes containing recycled or bio based materials07550-3 ADDENDUM #1
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
- NAICS 238160Roofing Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Follow Castle Creek Bridge Repair Active Contract Opportunity Notice ID 127EAW26Q0039 Related Notice
AGRICULTURE, DEPARTMENT OF
Bid Due: 7/08/2026
Pavement repair, drainage, MG...
Pavement repair, drainage, MGS, Mod lighting systems and TMS.Details Event ID 04-1W7104 Format/Type:
State Government of California
Bid Due: 8/04/2026