JONES RUN FLOODGATE REPAIR
Project Information
- Bid Title
- JONES RUN FLOODGATE REPAIR
- Issuing Agency
- City of Frankfort
- Location
- Kentucky
- Published Date
- Apr 29, 2026
- Closing Date
- Jun 16, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- 22526001-66
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid Number: 22526001-66
Bid Title: JONES RUN FLOODGATE REPAIR
Category: JONES RUN FLOOD GATE Status: Open Publication Date/Time: 4/29/2026 9:00 AM Closing Date/Time: 6/16/2026 2:00 PM Related Documents: - Attachment Preview
-
FLOOD GATEREPAIRPROJECT SITELOCATION MAPFRANKFORT DEPARTMENT OFPUBLIC WORKSFRANKFORT, KENTUCKYJONES RUN FLOOD GATEFRANKLIN COUNTY, KENTUCKYFRANKLINCOUNTYPROJECTSITEINDEX OF SHEETSSHEET NO. TITLE01COVER SHEET02GENERAL NOTES03STRUCTURAL NOTES04EXISTING CONDITIONS05DEMOLITION AND EPSC PLAN06PROPOSED LAYOUT PLAN07STRUCTURAL DETAILS08CIVIL DETAILSPREPARED BYStantec Consulting Services Inc.www.stantec.comDigitally signed bySeverance,VincentDN:CN="Severance,Vincent",OU=Internal,Severance, Vincent OU=users,OU=stantec,DC=corp, DC=adsReason: I amapproving thisdocumentDate: 2026.04.1610:45:17-04'00'04/16/2026ISSUED FOR CONSTRUCTIONJONES RUN FLOOD GATE REPAIRCOVER SHEET01GENERAL INFORMATION1. THE CONTRACTOR SHALL CONDUCT ITS OPERATIONS WITHIN THE WORK LIMITS INDICATED ON THE DRAWINGS FOR THEPROJECT SITE, EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS.2. THE GENERAL SEQUENCE OF WORK WILL INCLUDE THE FOLLOWING:a. JONES FLOOD GATE: REMOVAL OF SELECTED PORTIONS OF EXISTING ASPHALT PAVEMENT AND PORTIONS OF THECONCRETE FLOOD GATE SILL, STABILIZATION OF PAVEMENT SUBGRADE, AND INSTALLATION OF REINFORCEDCONCRETE PAVEMENT AND SELECTED CONCRETE FLOOD GATE SILL REPLACEMENT. LASTLY, ALL DISTURBED ANDSOIL FILL AREAS SHALL BE GRADED, FERTILIZED, SEEDED, MULCHED AND NETTED.3. THE CONTRACTOR IS CAUTIONED THAT THE PROJECT SITE IS SUBJECT TO FLOODING DURING RAINFALL EVENTS. THEFRANKFORT DEPARTMENT OF PUBLIC WORKS SHALL REVIEW FORMAL REQUESTS FROM THE CONTRACTOR FOR TIMEEXTENSIONS IF A FLOOD EVENT AFFECTS SITE ACCESS TO INCREASE THE PROJECT SCHEDULE BASED ON THE REALIMPACTS TO THE PROJECT CRITICAL PATH BASED ON THE CONTRACTOR'S MOST RECENT SCHEDULE. THE FRANKFORTDEPARTMENT OF PUBLIC WORKS SHALL NOT CONSIDER ANY EQUITABLE ADJUSTMENTS TO THE CONTRACT AMOUNTFOR TEMPORARY SHUTDOWNS, EQUIPMENT DEMOBILIZATION AND RE-MOBILIZATION, OR SITE DAMAGE ASSOCIATEDWITH RAINFALL EVENTS AND/OR HIGH WATER CONDITIONS. THE CONTRACTOR IS NOT ELIGIBLE FOR ADDITIONALCOMPENSATION DUE TO DELAYS OR IMPACTS RELATED TO RAINFALL EVENTS AND/OR HIGH WATER CONDITIONS.4. THE CONTRACTOR SHALL SUBMIT A WORK PLAN DETAILING THE PROPOSED SEQUENCE OF WORK AND THEAPPROPRIATE EQUIPMENT REQUIRED TO PERFORM THE WORK. THE WORK PLAN MUST BE ACCEPTED BY THE ENGINEERPRIOR TO PERFORMING ANY OF THE WORK.5. THE CONTRACTOR SHALL SUBMIT A PROPOSED CONSTRUCTION SCHEDULE TO THE ENGINEER PRIOR TO BEGINNINGCONSTRUCTION.6. CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING STORAGE AND STAGING AREAS FOR EQUIPMENT ANDMATERIALS OUTSIDE THE CONTRACTOR'S WORK LIMITS (IF NECESSARY). THE CONTRACTOR SHALL ESTABLISHAPPROPRIATE AGREEMENTS WITH THE OWNERS OF SUCH SITES. THE CONTRACTOR IS SOLELY RESPONSIBLE FORSECURING ANY APPLICABLE PERMITS FROM REGULATORS FOR WORK OUTSIDE OF THE WORK LIMITS. OFFSITE AREASSHALL BE MAINTAINED IN COMPLIANCE WITH THE PROVISIONS ESTABLISHED FOR AREAS INSIDE THE CONTRACTOR'SWORK LIMITS AT THE PROJECT SITES. THE OWNER AND ENGINEER SHALL HAVE ACCESS TO ALL OFFSITE STORAGE ANDSTAGING AREAS USED IN THE EXECUTION OF THIS WORK.7. CONSTRUCTION ACTIVITIES SHALL COMPLY WITH CURRENT OSHA AND ALL OTHER APPLICABLE REGULATIONS FORHEALTH AND SAFETY. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROJECT SITE SAFETY THROUGHOUTCONSTRUCTION.8. CONSTRUCTION ACTIVITIES SHALL COMPLY WITH ALL CURRENT AND APPLICABLE FEDERAL, STATE, AND LOCALREGULATIONS GOVERNING DISCHARGES INTO AND/OR UPON AIR, WATER, OR LAND. THE CONTRACTOR IS SOLELYRESPONSIBLE FOR COMPLYING WITH THESE REGULATIONS.PERMITTING1. THE OWNER WILL SECURE THE FOLLOWING PERMITS FOR THE FLOOD GATE PROJECT THROUGH THE KENTUCKYDIVISION OF WATER AND U.S. ARMY CORPS OF ENGINEERS.- FLOODPLAIN PERMIT/STREAM CONSTRUCTION PERMIT FOR CONSTRUCTION IN OR ALONG A STREAM- CWA SECTION 408THE CONTRACTOR SHALL COMPLY WITH ALL CONDITIONS IN THESE PERMITS AND IS RESPONSIBLE FOR SECURING ANYADDITIONAL PERMITS REQUIRED PRIOR TO CONSTRUCTION.2. THE CONTRACTOR SHALL FILE A KPDES NOTICE OF INTENT (NOI) PRIOR TO THE START OF CONSTRUCTION, AND ANOTICE OF TERMINATION (NOT) FOLLOWING CONSTRUCTION COMPLETION WITH THE KENTUCKY DIVISION OF WATER,AND SHALL MEET ALL REQUIREMENTS OF THESE NOTICES.3. IN ACCORDANCE WITH ALL APPLICABLE LAWS AND ORDINANCES, THE CONTRACTOR SHALL IDENTIFY, SECURE, ANDPERMIT (IF NECESSARY) SUITABLE OFF-SITE DISPOSAL SITE(S) FOR EXCAVATED OR DEMOLISHED MATERIALS. DISPOSALSITE SELECTION AND ACCEPTANCE MAY REQUIRE COORDINATION WITH PERMIT REGULATORS. SHOULD THISCOORDINATION BE NECESSARY, THE OWNER WILL NOT CONSIDER ANY CONTRACTOR COSTS OR SCHEDULE CLAIMSWHATSOEVER ASSOCIATED WITH DELAYS OR ACTIONS REQUIRED BY PERMIT REGULATORS. REGULATORY AGENCYCOORDINATION SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.SITE CONDITIONS1. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH THE PROJECT AREA AND SITE CONDITIONS PRIOR TOBID SUBMISSION.2. HORIZONTAL COORDINATES SHOWN ON THE DRAWINGS ARE BASED ON THE KENTUCKY STATE PLANE COORDINATESYSTEM, NORTH ZONE, NORTH AMERICAN DATUM OF 1983 (NAD83).3. ELEVATIONS ON THE DRAWINGS PRODUCED BY STANTEC CONSULTING SERVICES, INC. ARE REFERENCED TO THENORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88), GEOID 18.4. EXISTING SITE FEATURES, DIMENSIONS, AND TOPOGRAPHY WERE OBTAINED FROM A SURVEY PERFORMED BY QK4, INC.ON JUNE 16, 2025. EXISTING CONDITIONS MAY HAVE CHANGED SINCE THAT TIME. THE CONTRACTOR IS SOLELYRESPONSIBLE FOR VERIFICATION OF ALL EXISTING SITE FEATURES, DIMENSIONS, AND ELEVATIONS PRIOR TO BIDSUBMITTAL.5. DIMENSIONS OF THE EXISTING STRUCTURES SHOWN ON THESE PLANS ARE FOR GENERAL REFERENCE ONLY. THEYHAVE BEEN TAKEN FROM ORIGINAL CONSTRUCTION DRAWINGS, SUBSEQUENT REHABILITATION DRAWINGS, ORINCOMPLETE FIELD SURVEYS AND ARE NOT GUARANTEED. THE CONTRACTOR SHALL TAKE ALL FIELD MEASUREMENTSAS NECESSARY TO ENSURE PROPER FIT OF THE FINISHED WORK, AND THE CONTRACTOR SHALL ASSUME FULLRESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS. IF THE FIELD CONDITIONS AND DIMENSIONS DIFFERFROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL USE THE FIELD CONDITIONS AND DIMENSIONS ANDMAKE THE APPROPRIATE CHANGES TO THOSE SHOWN ON THE DRAWINGS, AS ACCEPTED BY THE ENGINEER. WHENSHOP DRAWINGS BASED ON FIELD MEASUREMENTS ARE SUBMITTED FOR ACCEPTANCE, THE FIELD MEASUREMENTSSHALL BE INDICATED ON THE SUBMITTED SHOP DRAWINGS FOR THE REVIEWER'S REFERENCE.6. SOME MECHANICAL COMPONENTS AND UTILITIES HAVE NOT BEEN LOCATED AND ARE NOT DEPICTED ON THEDRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND VERIFY ALL MECHANICAL COMPONENTSAND UTILITIES, MAKE APPROPRIATE ARRANGEMENTS REGARDING RELOCATION, MAINTAIN UTILITY SERVICETHROUGHOUT THE CONSTRUCTION PERIOD, AND MAKE FINAL RELOCATIONS AT THE COMPLETION OF WORK. THECONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING UTILITIES, WHETHER SHOWN OR NOTSHOWN ON THE DRAWINGS, DUE TO ITS OPERATIONS. WHERE UTILITIES ARE SHOWN OR INDICATED ON THE DRAWINGS,THE INFORMATION GIVEN IS IN ACCORDANCE WITH THE BEST INFORMATION IN THE POSSESSION OF THE OWNER BUT ISAPPROXIMATE. THE DATA IS NOT WARRANTED TO BE EITHER COMPLETE OR CORRECT, AND THE CONTRACTOR SHALLASSUME ALL RISKS RESULTING FROM CONDITIONS ARISING FROM THE APPROXIMATIONS SHOWN.7. IT SHALL BE DISTINCTLY UNDERSTOOD THAT ANY REFERENCE TO ROCK, SOIL, OR ANY OTHER MATERIAL ON THEDRAWINGS WHETHER IN NUMBERS, WORDS, LETTERS, OR LINES, IS SOLELY FOR THE OWNER'S INFORMATION AND ISNOT TO BE TAKEN AS AN INDICATION OF CLASSIFIED EXCAVATION OR THE QUANTITY OF ANY OF THE VARIOUSMATERIALS INVOLVED. THE BIDDER MUST DRAW ITS OWN CONCLUSIONS AS TO THE CONDITIONS LIKELY TO BEENCOUNTERED AT THE SITE.GENERAL NOTESSITE ACCESS1. ACCESS TO THE PROJECT SITE SHOULD BE EVALUATED BY THE CONTRACTOR PRIOR TO BIDDING. SECURING ANYOFF-SITE EASEMENTS, RIGHTS-OF-WAY, ETC. TO IMPROVE ACCESS OR ALLOW LOADING/UNLOADING OF EQUIPMENT ORMATERIALS SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND SHALL BE OBTAINED IN ACCORDANCEWITH ALL APPLICABLE LAWS AND ORDINANCES.2. THE CONTRACTOR SHALL GIVE SPECIAL ATTENTION TO THE PRESENCE OF OVERHEAD ELECTRIC POWER LINES ANDBURIED FIBER OPTIC LINES AND STORM SEWER PIPES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATINGOUTAGES AND/OR RELOCATIONS WITH THE AFFECTED UTILITY AS MAY BE NECESSARY TO SAFELY PERFORM THE WORK.IN ADDITION, THE CONTRACTOR SHALL OBSERVE AND MAINTAIN CLEARANCE FROM ELECTRIC POWER LINES ASREQUIRED BY THE RESPECTIVE UTILITY AND OSHA REGULATIONS.3. THROUGHOUT THE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL DEPLOY AND MAINTAIN WARNING SIGNS AT SITEACCESS LOCATIONS IN ACCORDANCE WITH RESPECTIVE REGULATORY CRITERIA TO DETER THE PUBLIC FROMAPPROACHING THE PROJECT SITE.SITE SETUP AND MAINTENANCE1. THE CONTRACTOR SHALL COORDINATE PLACEMENT OF OFFICES AND EMPLOYEE PARKING WITH THE OWNER ANDENGINEER. NO EXISTING BUILDING SHALL BE USED WITHOUT PERMISSION FROM THE OWNER AND ENGINEER.2. AT A MINIMUM, PARKING AREAS SHALL HAVE A GRADED SURFACE OF STONE.3. THE CONTRACTOR IS RESPONSIBLE FOR SUPPLYING ALL UTILITIES, DRINKING WATER SUPPLIES, AND SANITARYFACILITIES NEEDED FOR CONSTRUCTION ACTIVITIES. SUCH FACILITIES SHALL BE REMOVED UPON COMPLETION OF THEWORK.4. SECURITY OF THE WORK SITE AREAS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALLPROVIDE ALL NECESSARY SECURITY MEASURES, WHICH MAY INCLUDE TEMPORARY FENCING OR SECURITY GUARDS, ASDEEMED NECESSARY THROUGHOUT THE DURATION OF CONSTRUCTION. THE OWNER WILL NOT BE RESPONSIBLE FORDAMAGES INCURRED AS A RESULT OF VANDALISM, THEFT, ETC. THE CONTRACTOR SHALL PROVIDE CAMERASURVEILLANCE OF THE WORK SITE THROUGHOUT THE DURATION OF CONSTRUCTION.5. THE CONTRACTOR SHALL MAINTAIN WORK SITES IN A CLEAN AND WORKMAN-LIKE MANNER AT ALL TIMES.CONSTRUCTION DEBRIS, WASTE MATERIALS, RUBBISH, ETC., SHALL BE REMOVED FROM THE SITE IN A TIMELY MANNER.AT THE COMPLETION OF CONSTRUCTION, THE CONTRACTOR SHALL RESTORE AFFECTED AREAS TO THEIR ORIGINALCONDITION OR BETTER.6. THE CONTRACTOR SHALL CONTROL THE GROWTH OF WEEDS AND VEGETATION IN DISTURBED AREAS, WITHIN FENCEDAREAS INSIDE THE CONTRACTOR'S WORK LIMITS, AND WITHIN OFFSITE STORAGE OR STAGING AREAS. THECONTRACTOR SHALL BE RESPONSIBLE FOR MOWING THESE AREAS AS NEEDED.7. DELIVERED MATERIALS FOR THE PURPOSE OF PERFORMING THE WORK SHALL BE TEMPORARILY STORED IN AREASSELECTED BY THE CONTRACTOR AND ACCEPTED BY THE OWNER AND ENGINEER. THE CONTRACTOR PARKING ANDOFFICE AREAS SHALL NOT BE USED FOR TEMPORARY STORAGE.8. STOCKPILE AREAS FOR SOILS AND/OR SEDIMENTS (NOT INCLUDING STONE AND CONCRETE AGGREGATES) SHALL BEGRADED TO MAINTAIN POSITIVE DRAINAGE AT ALL TIMES. THE SIDE SLOPES SHALL HAVE A 4H:1V MAXIMUM SLOPE. THECONTRACTOR IS SOLELY RESPONSIBLE FOR INSTALLING AND MAINTAINING MEASURES THAT CONTROL EROSION ANDTHE TRANSPORT OF SEDIMENT FROM THE WORK SITE INTO ADJACENT CREEKS OR STORM SEWERS. EROSION ANDSEDIMENT CONTROL MEASURES SHALL BE IN PLACE PRIOR TO ANY SITE DISTURBANCE AND SHALL BE MAINTAINEDTHROUGHOUT THE WORK. AT A MINIMUM, EROSION, AND SEDIMENT CONTROL MEASURES SHALL INCLUDE SILT FENCINGAROUND DISTURBED AREAS. SURFACE DRAINAGE SHALL BE CONTROLLED WITH TEMPORARY DITCHES, CULVERTS, ETC.,AS NECESSARY. ADDITIONAL MEASURES SHALL BE PERFORMED IN ACCORDANCE WITH THE MANUAL "KENTUCKY BESTMANAGEMENT PRACTICES FOR CONSTRUCTION ACTIVITIES" AND IN COMPLIANCE WITH APPLICABLE PERMITS.9. AT THE SITE, THE CONTRACTOR SHALL KEEP ROADS USED FOR SITE ACCESS FREE OF MUD AND DEBRIS.10. THE CONTRACTOR SHALL MAINTAIN SURVEY CONTROL POINTS FOR THE DURATION OF THE PROJECT. THECONTRACTOR SHALL PROVIDE ALL CONSTRUCTION SURVEYING AND STAKING NECESSARY FOR SITE LAYOUT ANDCONSTRUCTION FROM THE CONTROL POINTS.EXCAVATION AND GRADING1. ALL CLEARED TOPSOIL MATERIAL SHALL BE STOCKPILED. DURING FINAL DRESSING, THE STOCKPILED TOPSOIL SHALL BESPREAD EVENLY ACROSS DISTURBED AREAS RECEIVING EARTHEN FILL. EXCAVATION WILL NOT BE CLASSIFIED FORPAYMENT PURPOSES TO DISTINGUISH BETWEEN EARTH, ROCK, OBSTRUCTIONS OR OTHER MATERIALS.2. THE CONTRACTOR SHALL CONSTRUCT THE BACKFILLS IN THE APPROPRIATE ZONES AND WITH THE MATERIALSREQUIRED IN THE DRAWINGS.3. DENSE GRADED AGGREGATE (DGA) SHALL CONFORM TO SECTION 805.06 OF THE KYTC "STANDARD SPECIFICATIONSFOR ROAD AND BRIDGE CONSTRUCTION" FOR DENSE GRADED AGGREGATE AND CRUSHED STONE BASE.4. NO ADDITIONAL PAYMENT FOR QUANTITIES OF STONE AGGREGATE OR OTHER MATERIALS PLACED ON THE PROJECTWILL BE CONSIDERED BY THE OWNER DUE TO SUBGRADE SETTLEMENT, TEMPORARY EXCAVATIONS, OR INTRUSION OFSTONE INTO SOFT SUBGRADE.SITE RESTORATION1. THROUGHOUT CONSTRUCTION, THE CONTRACTOR SHALL REPAIR DAMAGE TO AND MAINTAIN A MINIMUM OF ONE OPENLANE OF TRAFFIC ALONG LEWIS FERRY ROAD AT ALL TIMES. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALLNECESSARY PERMITS FOR WORK WITHIN THE ROAD RIGHT-OF-WAYS INCLUDING A KYTC-APPROVED TEMPORARYTRAFFIC CONTROL PLAN.2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL ACCESS ROADS, PARKING, AND STORAGE AREASUSED DURING CONSTRUCTION, AND SHALL RESTORE AREAS TO THEIR ORIGINAL CONDITION OR BETTER ONCECONSTRUCTION IS COMPLETE.3. ALL AREAS OF EXPOSED SOIL DISTURBED DURING CONSTRUCTION SHALL BE RESTORED AND RESEEDED. FINALGRADING, FERTILIZATION, SEEDING AND MULCHING OF ALL SUCH AREAS SHALL BE COMPLETED AS SOON AS PRACTICALAFTER COMPLETION OF THE RESPECTIVE PORTIONS OF THE PROJECT. ASPHALT ADHESIVE, NETTING, AND/OR OTHERMEASURES SHALL BE APPLIED IN SUFFICIENT QUANTITIES TO SECURE THE MULCH BUT SHALL NOT INHIBIT GRASSGROWTH. SEEDING SHALL BE PERFORMED AT THE FOLLOWING RATES:SUMMARY OF SPECIFICATIONS FOR FINAL SEEDINGSEEDSEED RATE (LBS/ACRE)VIRGINIA WILD RYE60ANNUAL RYE GRASS20RED CLOVER20RED TOP20ORCHARD GRASS20FERTILIZER: 10-20-10 GRADE, WITH 50 PERCENTNITROGEN IN UREA FORM, APPLIED AT 600 LBS/ACRE.4. AT THE COMPLETION OF WORK, THE CONTRACTOR SHALL SUBMIT A RECORD SET OF AS-BUILT DRAWINGS TO THEENGINEER. THESE AS-BUILT DRAWINGS SHALL SHOW ALL DEVIATIONS FOR THE ORIGINAL DESIGN. THESE DRAWINGSSHALL BE MARKED IN RED INK ON A BLACK LINE SET OF DRAWINGS.CONSTRUCTION RESTRICTIONS1. THE WORK SHALL INCLUDE ONLY THOSE ITEMS ESTABLISHED IN THE CONTRACT, AS AGREED TO BETWEEN THE OWNERAND THE CONTRACTOR.2. ALL EXISTING STRUCTURES AND FEATURES ARE TO BE PRESERVED AND PROTECTED, EXCEPT WHERE SPECIFICALLYINDICATED ON THE DRAWINGS.3. ALL CONSTRUCTION ACTIVITIES SHALL BE EXECUTED IN A MANNER AND SEQUENCE THAT PROTECTS THE INTEGRITY OFTHE EXISTING STRUCTURES AT ALL TIMES.4. BLASTING IS PROHIBITED.5. NIGHTTIME OPERATIONS: IF THE CONTRACTOR PERFORMS NIGHTTIME OPERATIONS, THE WORK AREA SHALL BEAPPROPRIATELY ILLUMINATED PER THE APPLICABLE OSHA REQUIREMENTS TO ALLOW SAFE AND PROPEROBSERVATION AND PERFORMANCE OF WORK.6. DUST CONTROL: THE CONTRACTOR SHALL MAINTAIN ALL EXCAVATIONS, TEMPORARY EMBANKMENTS, STOCKPILES,HAUL ROADS, ACCESS ROADS, PLANT SITES, WASTE AREAS, AND ALL OTHER WORK AREAS TO PREVENT DUST THATWOULD BE A HAZARD OR NUISANCE TO OTHERS. DUST CONTROL SHALL BE PERFORMED AS THE WORK PROCEEDS, ANDWHENEVER A DUST NUISANCE OR HAZARD OCCURS.7. THE CONTRACTOR SHALL PROTECT AND PRESERVE ALL TREES OUTSIDE THE WORK LIMITS AT THE SITE. PROTECTIONSHALL INCLUDE TEMPORARY FENCING ALONG OR AROUND THE DRIPLINE OF TREES WITHIN OR BORDERING THECONTRACTOR'S WORK LIMITS IF CONSTRUCTION ACTIVITIES ARE TO BE PERFORMED WITHIN 25 FEET OF THE DRIPLINE.8. THE CONTRACTOR SHALL PERFORM A PRE-CONSTRUCTION SURVEY OF ALL ADJACENT BUILDINGS AND ASSOCIATEDSTRUCTURES WITHIN 100 FEET OF THE CONTRACTOR'S WORK LIMITS. THE PRE-CONSTRUCTION SURVEY SHALL ALSODOCUMENT THE CONDITION OF ALL ROADWAYS THAT MAY EXPERIENCE SIGNIFICANT HEAVY CONSTRUCTION TRAFFIC.THE SURVEY SHALL ADEQUATELY DOCUMENT PRE-CONSTRUCTION CONDITIONS USING METHODS SUCH ASPHOTOGRAPHS AND/OR VIDEO. ALL INFORMATION OBTAINED SHALL BE SUBMITTED TO THE ENGINEER PRIOR TOCONSTRUCTION ACTIVITIES. REPAIR OF DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES SHALL BE THE RESPONSIBILITYOF THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER.9. THE CONTRACTOR SHALL COORDINATE WITH THE CITY OF FRANKFORT AND BUFFALO TRACE DISTILLERY PRIOR TOPERFORMING ANY CONSTRUCTION ACTIVITIES THAT MAY IMPACT ACCESS TO THE DISTILLERY.FINAL ACCEPTANCE1. ONCE ALL REPAIRS HAVE BEEN COMPLETED, THE CONTRACTOR SHALL INSTALL AND ASSEMBLE THE FLOODGATE ANDALL COMPONENTS TO DEMONSTRATE FINAL ALIGNMENT AND FITUP. AFTER WRITTEN ACCEPTANCE BY THE ENGINEER,THE CONTRACTOR SHALL DISASSEMBLE AND REMOVE THE FLOODGATE. COORDINATE WITH FRANKFORT PUBLIC WORKSFOR ACCESS TO AND STORAGE OF THE FLOODGATE AND ALL COMPONENTS.ISSUED FOR CONSTRUCTIONJONES RUN FLOOD GATE REPAIRGENERAL NOTES02STRUCTURAL NOTES AND DETAILSCONCRETE STRUCTURES1. GENERAL:A. EXCEPT AS OTHERWISE NOTED OR SPECIFIED, THESE GENERAL NOTES SHALLAPPLY TO THE CONCRETE STRUCTURES.B. ALL DIMENSIONS ARE IN FEET AND INCHES AND ALL ELEVATIONS ARE IN FEETUNLESS SPECIFICALLY NOTED OTHERWISE.C. CHECK ALL DIMENSIONS PRIOR TO COMMENCING WORK OR NOTIFY ENGINEER'SREPRESENTATIVE OF ANY CONFLICTS OR ERRONEOUS INFORMATION. MEASUREDDIMENSIONS FOR THE EXISTING STRUCTURES WILL APPLY.D. REINFORCED CONCRETE DESIGN CONFORMS TO "STRENGTH DESIGN OFREINFORCED CONCRETE HYDRAULIC STRUCTURES (EM1110-2-2104)", US ARMYCORPS OF ENGINEERS, WASHINGTON, DC, 01 NOV. 2023.2. CONCRETE:A. DESIGN OF REINFORCED CONCRETE IS BASED ON CONCRETE HAVING A MINIMUMCOMPRESSIVE STRENGTH OF 4500 PSI AT 28 DAYS.B. AGGREGATE FOR CONCRETE SHALL CONFORM TO ASTM C-33 WITH A MAXIMUM SIZEOF ONE INCH.C. DO NOT PLACE CONCRETE WITHOUT PRIOR INSPECTION AND APPROVAL OFENGINEER'S REPRESENTATIVE.D. FORM WORK SHALL BE PLACED IN ACCORDANCE WITH TOLERANCES IN ACI 301, ASSHOWN OR AS SPECIFIED.3. REINFORCING STEEL:A. STEEL REINFORCEMENT SHALL COMPLY WITH REQUIREMENTS OF ASTM A-615 ANDSHALL HAVE MINIMUM YIELD STRENGTH OF 60,000 PSI.B. SEE TABLES ON THIS DRAWING FOR MINIMUM REQUIREMENTS FOR EMBEDMENTLENGTHS, LAPPED SPLICE LENGTHS AND END HOOK DETAILS.C. REINFORCING BARS SHALL BE FABRICATED IN ACCORDANCE WITH STANDARDFABRICATING TOLERANCES IN ACI 315.D. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH TOLERANCES IN ACI 301,AS SHOWN OR AS SPECIFIED.E. ALL VERTICAL REINFORCEMENT SHALL BE CONTINUED FOR ITS EMBEDMENT LENGTHINTO THE BASE OR FOOTING.4. SPACING:A. DIMENSIONS ARE TO THE CENTER LINE OF BAR UNLESS OTHERWISE SHOWN.B. THE FIRST AND LAST BARS IN WALLS AND SLABS, STIRRUPS IN BEAMS, AND TIES INCOLUMNS ARE TO START AND END AT A MAXIMUM OF ONE HALF OF THE ADJACENTBAR SPACING.C. REINFORCEMENT MAY BE ADJUSTED LATERALLY TO MAINTAIN A CLEAR DISTANCEOF 1 INCH BETWEEN REINFORCEMENT BARS AND KEYS, WATER STOPS, ANCHORBOLTS, FORM TIES, CONDUITS, AND OTHER EMBEDDED MATERIAL.5. COVER:A. CLEAR COVER FOR REINFORCEMENT SHALL BE 3 INCHES FOR FACES CASTDIRECTLY AGAINST EARTH AND 2 INCHES FOR ALL OTHER FACES UNLESS NOTEDOTHERWISE.B. REINFORCEMENT PARALLELING JOINTS SHALL HAVE A MINIMUM OF 2 INCHES OFCLEAR COVER.6. SPLICES:A. UNLESS OTHERWISE SHOWN, THE MINIMUM LENGTH FOR SPLICING PARALLEL BARSSHALL BE GIVEN IN THE TABLE ON THIS DRAWING.B. WHEN REINFORCING BARS OF DIFFERENT SIZE ARE TO BE SPLICED, THE LENGTH OFLAP SHALL BE GOVERNED BY THE SMALLER BAR DIAMETER.C. NONCONTACT LAP SPLICES SHALL NOT BE SPACED FARTHER APART THANONE-FIFTH THE REQUIRED LENGTH OF LAP OR 6 INCHES.D. SPLICES SHALL BE STAGGERED TO GIVE 12 INCHES CLEAR BETWEEN ENDS OFADJACENT SPLICES.E. REINFORCEMENT SHALL HAVE A MINIMUM LENGTH OF 20'-0" BETWEEN SPLICESUNLESS OTHERWISE SHOWN.F. SPLICES SHALL NOT CROSS CJ OR CTJ, UNLESS OTHERWISE SHOWN.7. CHAMFERS:A. CHAMFER ALL EXPOSED CORNERS 3/4 INCH UNLESS OTHERWISE SHOWN.B. CHAMFER JOINTS AS SHOWN ON THIS DRAWING'S DETAILS UNLESS OTHERWISESHOWN OR DESIGNATED.8. JOINTS:A. ALL CONSTRUCTION JOINTS, IDENTIFIED AS CJ, SHALL BE PROVIDED WHERE SHOWNON THE DRAWINGS. ALL OPTIONAL CONSTRUCTION JOINTS, IDENTIFIED AS OCJ, ARETO REDUCE THE VOLUME OF PLACEMENTS OR TO FACILITATE CONSTRUCTION. IFOPTIONAL JOINTS ARE PROVIDED, THEY SHALL BE ONLY AT THE LOCATIONS SHOWN.B. ADDITIONAL CONSTRUCTION JOINTS OR RELOCATION OF CONSTRUCTION JOINTSMAY BE USED SUBJECT TO ENGINEER ACCEPTANCE.C. ALL EXPANSION JOINTS, IDENTIFIED AS EJ, SHALL BE PROVIDED WHERE SHOWN ONTHE DRAWINGS.9. EMBEDDED MATERIALS:A. BEFORE PLACING CONCRETE, CARE SHALL BE TAKEN THAT ALL EMBEDDED ITEMSARE IN POSITION AND SECURELY FASTENED IN PLACE. ANCHOR BOLT LOCATIONSAND SETTING DETAILS ARE SHOWN ON STRUCTURAL STEEL, MISCELLANEOUSMETAL, AND CONCRETE DRAWINGS.CONCRETE SPECIFICATIONS- PORTLAND CEMENT ASTM C-150, TYPE I OR II, OR TYPE IL- POZZOLAN ASTM C618, CLASS F FLY ASH 20% TO 40% BY WEIGHT WHEN MIXED WITHPORTLAND CEMENT- AIR ENTRAINMENT ASTM C-233.- WATER REDUCER ASTM C494, TYPE A.- SET RETARDERS ASTM C494 TYPE B.- CAST IN PLACE CONCRETE SHALL MEET THE FOLLOWING PROPORTIONING ANDDESIGN REQUIREMENTS WITHOUT THE USE OF AN ASTM C494, TYPE F, HIGH RANGE WATERREDUCING ADMIXTURE:MINIMUM28-DAY COMPRESSIVESTRENGTH(psi)AIRCONTENT(%)4,5004-7CEMENTITOUSCONTENT(lbs./.cu.yd.)560 - 620MAXIMUMWATER/CEMENTITOUSRATIO0.45SLUMP(inches)3-5- SAMPLING FRESH CONCRETE PER ASTM C-172.- SLUMP TEST PER ASTM C-143.- AIR CONTENT TEST PER ASTM C-231.- COMPRESSIVE TEST PER ASTM C-31, ASTM C-39.- CONCRETE TEMPERATURE: TEST EVERY DELIVERY TRUCK.- PLACE CONCRETE PER ACI 301 AND ACI 309.- CONCRETE TEMPERATURE AT TIME OF PLACEMENT SHALL NOT BE LESS THAN 50°F NORMORE THAN 85°F.- CONCRETE SHALL BE DELIVERED TO THE SITE AND DISCHARGED INTO FORMS WITHIN 90MINUTES AFTER THE INTRODUCTION OF WATER TO THE CEMENT AND AGGREGATES.- VIBRATION SHALL BE APPLIED IN THE FRESHLY DEPOSITED CONCRETE BY INSERTING ANDREMOVING VIBRATOR AT POINTS UNIFORMLY SPACED AND NOT FARTHER APART THANTWICE THE RADIUS OVER WHICH THE VIBRATION IS VISIBLY EFFECTIVE. THE VIBRATORSHALL EXTEND INTO THE PREVIOUSLY PLACED LAYER OF FRESH CONCRETE, AT ALLPOINTS, TO ENSURE EFFECTIVE BOND BETWEEN LAYERS.- VIBRATION SHALL NOT BE APPLIED DIRECTLY TO REINFORCEMENT STEEL OR FORMS, ORTO CONCRETE THAT HAS HARDENED TO THE DEGREE THAT IT DOES NOT BECOME PLASTICWHEN VIBRATED.- CONCRETE SURFACES EXPOSED TO THE AIR SHALL BE COVERED AS SOON AS THECONCRETE HAS HARDENED SUFFICIENTLY AND SHALL BE KEPT CONTINUOUSLY WET FORAT LEAST THE FIRST 24 HOURS OF THE CURING PERIOD AND FOR THE ENTIRE CURINGPERIOD UNLESS CURING COMPOUND IS APPLIED.- APPLY FLOAT FINISH TO EXPOSED UNFORMED SURFACES, SUCH AS SLABS, FOLLOWINGSTRIKE-OFF OF CONCRETE TO GRADE. DO NOT WORK SURFACE UNTIL SURFACE HASHARDENED SUFFICIENTLY TO PREVENT AN EXCESS OF FINE MATERIAL FROM BEING DRAWNTO THE SURFACE. BEGIN FLOATING WHEN SURFACE WATER HAS DISAPPEARED ANDCONCRETE HAS STIFFENED SUFFICIENTLY TO PERMIT OPERATION OF POWER-DRIVENFLOAT. EXCESSIVE FLOATING WHILE CONCRETE IS SOFT WILL NOT BE PERMITTED.FINISH SURFACE WITH POWER-DRIVEN FLOATS, OR BY HAND FLOATING USINGBULL FLOATS OR DARBIES IF AREA IS SMALL OR INACCESSIBLE TO POWER UNITS.JOINT SEALANT DELASTICCV-1250 COMPRESSION SEALOR APPROVED EQUALEXISTING3/4" CHAMFERNEW SLAB1 41" THICKJOINT FILLER EXTEND TODEPTH OF CONCRETEBOND BREAKER TAPE OPTIONNOTES:1. CHAMFER MAY BE GROUND OR TOOLED.1 SEALANT AT EXPANSION JOINT03 NOT TO SCALEMINIMUMREINFORCEMENT BARDEVELOPMENT LENGTH(IN)MINIMUMREINFORCEMENT BARLAP SPLICE LENGTH(IN)MINIMUM END HOOKDEVELOPMENT LENGTH(IN)*BAR SIZE#3#4#5#6#7#8TOPOTHERBAR SIZETOPOTHERBAR SIZE Ldh A Q Z D1212#31616#3664.52.5 2.251512#42016#47862.531915#52519#59107.52.5 3.752318#62923#61012934.53325#74333#71214 10.5 3.5 5.253729#84937#814161246* SIDE COVER MUST BE 2.5"* END COVER MUST BE 2"NOTES:1. TABULATED VALUES ARE BASED ON UNCOATED GRADE 60 REBAR AND CONCRETE WITH f'c=4000 PSI AND 3" CLEAR COVER.2. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12 INCHES OF CONCRETE CAST BELOW THE BARS.3. TENSION DEVELOPMENT LENGTHS AND TENSION LAP SPLICE LENGTHS ARE CALCULATED IN ACCORDANCE WITH ACI 350, 12.8.2AND 12.9.2.4. LAP SPLICE LENGTHS ARE MULTIPLES OF TENSION DEVELOPMENT LENGTHS: CLASS A=1.0*Ld AND CLASS B=1.3*Ld (ACI 350, 12.9.2).5. BAR CENTER-TO-CENTER SPACING WAS ASSUMED TO BE GREATER THAN TWICE THE CONCRETE COVER PLUS ONE BARDIAMETER, SO THAT "c" WAS GOVERNED BY CONCRETE COVER RATHER THAN BY BAR SPACING. THEREFORE TABULATED VALUESARE NOT APPLICABLE FOR CENTER-TO-CENTER BAR SPACING LESS THAN 6".REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION1. SPECIAL INSPECTION FOR CONCRETE CONSTRUCTION WILL BE IN ACCORDANCEWITH 2018 IBC SECTION 1705.3 AND THE FOLLOWING TABLE.VERIFICATION AND INSPECTIONINSPECTIONCONTINOUS PERIODICINSPECTION OF REINFORCING STEEL.-XINSPECTION OF ANCHORSPOST-INSTALLED IN HARDENEDCONCRETE MEMBERS (B).A. ADHESIVE ANCHORS INSTALLED INHORIZONTALLY OR UPWARDLYINCLIDED ORIENTATIONS TO RESISTX-SUSTAINED TENSION LOADS.B. MECHANICAL ANCHORS ANDADHESIVE ANCHORS NOT DEFINED-XBY PART A.REFERENCEDSTANDARD (A)ACI 318: CH,20, 25-2, 25-326.6.1 - 26.6.3ACI 318: 17.8.2.4ACI 318: 17.8.2VERIFYING USE OF REQUIRED DESIGN-MIX.PRIOR TO CONCRETE PLACEMENT,FABRICATE SPECIMENS FOR STRENGTHTESTS, PERFORM SLUMP AND AIRXCONTENT TESTS, AND DETERMINE THETEMPERATURE OF THE CONCRETEINSPECTION OF CONCRETE ANDSHOTCRETE PLACEMENT FOR PROPERXAPPLICATION TECHNIQUES.VERIFY MAINTENANCE OF SPECIFIEDCURING TEMPERATURE AND-TECHNIQUES.INSPECT FORMWORK FOR SHAPE,LOCATION AND DIMENSIONS OF THE-CONCRETE MEMBER BEING FORMED.XACI 318: CH. 19,26.4.3, 26.4.4ASTM C172-ASTM C31ACI 318:26.5, 26.12-ACI 318: 26.5XACI 318:26.5.3 - 26.5.5ACI 318:X26.11.1.2 (B)IBCREFERENCE1908.4-1904.1,1904.2,1908.2,1908.31908.101908.6,1908.7,1908.81908.9-2 CONSTRUCTION JOINT (CJ) - SLABS03 NOT TO SCALEISSUED FOR CONSTRUCTIONJONES RUN FLOOD GATE REPAIRSTRUCTURAL NOTES0304/16/2026N 330,724N 330,722N 330,719CP #101N=3968679.246E=5175977.858El=512.17'IPC QK4 CTRLCONCRETE FLOODWALL(TYP.)EX. STRUCTURE505CONCRETESILL505505SHEET PILES(BELOW GRADE)OLD RAIL SLOTTHREADED RECESSFOR ANCHOR ROD(TYP.)505PAVEMENTDETERIORATION505N 330,717HEADWALLINV. IN = 500.86HEADWALLINV. OUT = 501.93EX. 16-IN CMPAERIAL ELECTRIC TRANSFORMERBANKN 330,724NOTES:1. HORIZONTAL COORDINATES ARE BASED ON THE KENTUCKY STATE PLANECOORDINATE SYSTEM, SINGLE ZONE, NORTH AMERICAN DATUM OF 1983(NAD83). ELEVATIONS ARE REFERENCED TO THE NORTH AMERICAN VERTICALDATUM OF 1988 (NAVD88).2. EXISTING SITE FEATURES, DIMENSIONS, RIGHT-OF-WAY, PROPERTYBOUNDARIES, AND TOPOGRAPHY WERE OBTAINED FROM SURVEYSPERFORMED BY QK4 IN JUNE 2025. EXISTING CONDITIONS MAY HAVECHANGED SINCE THAT TIME. THE CONTRACTOR IS RESPONSIBLE FORVERIFICATION OF ALL EXISTING SITE FEATURES, DIMENSIONS, ANDELEVATIONS PRIOR TO BID SUBMITTAL.3. SOME MECHANICAL COMPONENTS AND BURIED UTILITIES MAY NOT BE SHOWNHEREON. THE CONTRACTOR SHALL LOCATE AND VERIFY ALL MECHANICALCOMPONENTS AND BURIED UTILITIES PRIOR TO CONSTRUCTION. THECONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE AND REPAIRTO THE EXISTING UTILITIES, WHETHER SHOWN OR NOT SHOWN ON THEDRAWINGS DUE TO ITS OPERATIONS. IT IS THE CONTRACTOR'S SOLERESPONSIBILITY TO MAKE APPROPRIATE ARRANGEMENTS REGARDINGRELOCATION AND MAINTENANCE OF UTILITY SERVICE THROUGHOUTCONSTRUCTION. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR FINALRELOCATIONS, IF NECESSARY, AT THE COMPLETION OF THE WORK.EXISTING CONTOURSUNDERGROUND FIBEREXISTING STORM SEWEREXISTING WATER LINEEXISTING OVERHEAD TELECOMEXISTING OVERHEAD ELECTRIC &TELECOMEXISTING ELECTRIC POLEEXISTING HEADWALLN 330,722HEADWALLINV. IN = 502.94HEADWALLINV. IN = 501.15RCPEX. 18-INN 330,717500HEADWALLINV. OUT = 500.05N 330,719N05'10'GRAPHIC SCALE: 1" = 5'CONTOUR INTERVAL = 1'SECTION OR DETAIL NO.TARGET DRAWINGREFERENCE KEYISSUED FOR CONSTRUCTIONJONES RUN FLOOD GATE REPAIREXISTING CONDITIONS04N 330,724N 330,722CP #101N=3968679.246E=5175977.858El=512.17'IPC QK4 CTRLHEADWALLINV. IN = 500.862INSTALL KYTC08 SILT TRAP TYPE CHEADWALLINV. OUT = 501.93EX. STRUCTUREN 330,719505ASPHALT SAW-CUTLINE5'-0"50550524'-0"REMOVE ALL MATERIAL WITHINRAIL SLOTS INCLUDING ASPHALT,CONCRETE, AND TIMBER. (TYP)LIMITS OF ASPHALTPAVEMENT REMOVALCONTRACTORWORK LIMITS5055051SILT FENCE08N 330,717PROPOSED 1SILT FENCE 08ASPHALT SAW-CUTLINELIMITS OF ASPHALTPAVEMENT REMOVALHEADWALLINV. IN = 502.942 INSTALL PROPOSED KYTC08SILT TRAP TYPE CHEADWALLINV. IN = 501.15EX. 16-IN CMPAERIAL ELECTRIC TRANSFORMERBANKN 330,724NOTES:1. HORIZONTAL COORDINATES ARE BASED ON THE KENTUCKY STATE PLANECOORDINATE SYSTEM, SINGLE ZONE, NORTH AMERICAN DATUM OF 1983(NAD83). ELEVATIONS ARE REFERENCED TO THE NORTH AMERICAN VERTICALDATUM OF 1988 (NAVD88).2. EXISTING SITE FEATURES, DIMENSIONS, RIGHT-OF-WAY, PROPERTYBOUNDARIES, AND TOPOGRAPHY WERE OBTAINED FROM SURVEYSPERFORMED BY QK4 IN JUNE 2025. EXISTING CONDITIONS MAY HAVECHANGED SINCE THAT TIME. THE CONTRACTOR IS RESPONSIBLE FORVERIFICATION OF ALL EXISTING SITE FEATURES, DIMENSIONS, ANDELEVATIONS PRIOR TO BID SUBMITTAL.3. SOME MECHANICAL COMPONENTS AND BURIED UTILITIES MAY NOT BE SHOWNHEREON. THE CONTRACTOR SHALL LOCATE AND VERIFY ALL MECHANICALCOMPONENTS AND BURIED UTILITIES PRIOR TO CONSTRUCTION. THECONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE AND REPAIRTO THE EXISTING UTILITIES, WHETHER SHOWN OR NOT SHOWN ON THEDRAWINGS DUE TO ITS OPERATIONS. IT IS THE CONTRACTOR'S SOLERESPONSIBILITY TO MAKE APPROPRIATE ARRANGEMENTS REGARDINGRELOCATION AND MAINTENANCE OF UTILITY SERVICE THROUGHOUTCONSTRUCTION. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR FINALRELOCATIONS, IF NECESSARY, AT THE COMPLETION OF THE WORK.4. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INSTALLING ANDMAINTAINING MEASURES THAT CONTROL EROSION AND THE TRANSPORT OFSEDIMENT INTO THE STORM SYSTEM. EROSION AND SEDIMENT CONTROLMEASURES SHALL BE IN PLACE PRIOR TO ANY SITE DISTURBANCE AND SHALLBE MAINTAINED THROUGHOUT THE WORK IN ACCORDANCE WITH THESEDRAWINGS. AT A MINIMUM, EROSION AND SEDIMENT CONTROL MEASURESSHALL INCLUDE SILT FENCE AND SILT TRAPS. AS NECESSARY, ADDITIONALMEASURES SHALL BE PERFORMED IN ACCORDANCE WITH THE MANUAL"KENTUCKY BEST MANAGEMENT PRACTICES FOR CONSTRUCTION ACTIVITIES"AND IN COMPLIANCE WITH APPLICABLE PERMITS. THE EROSION ANDSEDIMENT CONTROL PLAN PROVIDED ON THIS PLAN IS FOR GENERALREFERENCE ONLY. THE CONTRACTOR SHALL SUBMIT AN EROSION ANDSEDIMENT CONTROL PLAN FOR ENGINEER ACCEPTANCE.5. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LAYDOWN AREASWITH THE CITY OF FRANKFORT, AS NEEDED.N 330,722EXISTING CONTOURSUNDERGROUND FIBEREXISTING STORM SEWEREXISTING WATER LINEEXISTING OVERHEAD TELECOMEXISTING OVERHEAD ELECTRIC &TELECOMEXISTING ELECTRIC POLEEXISTING HEADWALLSAWCUT LINEASPHALT PAVEMENT REMOVALCONCRETE PAVEMENT REMOVALPROPOSED SILT FENCEPROPOSED SILT TRAP TYPE CCONTRACTOR WORK LIMITSRCPEX. 18-INN 330,717500HEADWALLINV. OUT = 500.05N 330,719N05'10'GRAPHIC SCALE: 1" = 5'CONTOUR INTERVAL = 1'SECTION OR DETAIL NO.TARGET DRAWINGREFERENCE KEYISSUED FOR CONSTRUCTIONJONES RUN FLOOD GATE REPAIRDEMOLITION AND EPSC PLAN05
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
UPCOMING!! RFP 20262019 T&O H...
Project: UPCOMING!! RFP 20262019 T&O HVAC & BARN BOILER REPLEACEMENT AND REPAIR SERVICES
The Transit Authority of River City
Bid Due: 8/01/2026
Fire Alarm System Maintenance...
Description: Fire Alarm System Maintenance TCOB & KSOB Department: Facilities & Support Services
State Government of Kentucky
Bid Due: 10/14/2026