6515--DUOLITH Acute Care Shockwave Therapy Device - 518-26-4-7480-0062
Project Information
- Bid Title
- 6515--DUOLITH Acute Care Shockwave Therapy Device - 518-26-4-7480-0062
- Issuing Agency
- VETERANS AFFAIRS, DEPARTMENT OF
- Location
- Massachusetts
- Published Date
- Sep 25, 2026
- Closing Date
- Sep 29, 2026
- Government Level
- Federal
- Status
- Closed
- Ref. #
- 36C24126Q0850
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Follow6515--DUOLITH Acute Care Shockwave Therapy Device - 518-26-4-7480-0062ActiveContract OpportunityNotice ID36C24126Q0850Related NoticeDepartment/Ind. AgencyVETERANS AFFAIRS, DEPARTMENT OFSub-tierVETERANS AFFAIRS, DEPARTMENT OFOffice241-NETWORK CONTRACT OFFICE 01 (36C241)General InformationLooking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Sep 24, 2026 08:13 pm EDT
- Original Date Offers Due: Sep 29, 2026 02:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Oct 29, 2026
-
Initiative:
- None
Classification- Original Set Aside:
- Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
- 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
-
Place of Performance:
VAMC Bedford MA 200 Springs Street , 01730-1114USA
DescriptionCombined Synopsis Solicitation for Commercial Products and Commercial Services
DuoLith SD1 T TOP Ultra Dual Modality Shockwave Therapy System & OrthoPulse Ultra 100
This is a combined synopsis/solicitation for commercial products prepared in accordance with Revolutionary FAR Overhaul (RFO) in FAR 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through the most recent Federal Acquisition Circular (FAC). Set Aside: UNRESTRICTED (Open Market)
NAICS: 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
PSC/FSC: 6515 Medical and Surgical Instruments, Equipment, and Supplies
Small Business Size Standard: 1,250 employees Procuring Activity
Department of Veterans Affairs
Network Contracting Office 1 (New England)
940 Belmont Street, Brockton, MA 02301
Point of Contact: Harris, Sherrye Sherrye.Harris@va.gov
Delivery Terms and Address
FOB: Destination
Delivery Address: VAMC Bedford, 200 Springs Road, Bedford, MA 01730
Required Delivery Date: Vendor to state best achievable lead time.
Supplies/Services
Line Item 0001 DuoLith SD1 T TOP Ultra Dual Modality Shockwave Therapy System
Quantity: 1 Each
Description: Dual modality shockwave therapy system on a single platform/cart providing both focused (electromagnetic, FSW) and radial/pressure wave (RPW) delivery; configured for shared clinical use by Pain and Podiatry.
Salient Characteristics:
Dual modality shockwave on a single platform/cart: BOTH focused (electromagnetic, FSW) and radial/pressure wave (RPW) delivery. Pain and Podiatry use both modalities for different tissue depths and indications; a single modality device would not meet the shared clinical need.
Focused source with FDA labeling supporting the chronic plantar fasciitis indication for Podiatry s use (PMA/approval for chronic proximal plantar fasciitis).
Focused source parameters: energy flux density approximately 0.01 to 0.55 mJ/mm²; adjustable focal depth via stand offs with focal zones spanning roughly 0 to 65 mm; pulse frequency 1 to 8 Hz.
Radial source parameters: pressure approximately 1 to 5 bar; frequency 1 to 21 Hz; includes a standard musculoskeletal radial transmitter/applicator set.
Required Components
Focused electromagnetic FSW unit
F SW Sepia handpiece
Standard accessory kit: handpiece bracket; water bag; silicon oil; UltraGel coupling gel; power cord; Stand Off I (30 mm); Stand Off II (15 mm); closing ring; operating manual
Mobile stand/cart with second shelf
Tablet with stand (system operation)
Line Item 0002 OrthoPulse Ultra 100 (Radial/Pressure Wave) System
Quantity: 1 Each
Description: Radial/pressure wave therapy system for superficial myofascial and musculoskeletal applications.
Required Components OrthoPulse configuration (Brand Name or Equal):
Radial/pressure wave generator console
Falcon D Actor handpiece
Radial applicator/transmitter set (9) with case
V Actor handpiece
Falcon revision set (replacement wear items: tubes and bullets)
D Actor handpiece brush
EPAT/ESWT patient literature kit
Warranty for Items 1 and 2
Minimum 2 year factory warranty for device(s) and compressor
Minimum 1,000,000 pulse wear warranty
Submission Requirements
Technical Submission: Detailed documentation mapping to each salient characteristic above and FDA PMA evidence for the focused plantar fasciitis indication.
Authorized Distributor Letter: Documentation from the OEM verifying the Offeror is an authorized distributor for the proposed system(s).
Delivery timeline
Evaluation Criteria
Comparative evaluation will be used under RFO Simplified Acquisition Procedures. Award will be made to the lowest priced, technically acceptable quotation that:
Meets all technical requirements and characteristics of the DuoLith SD1 T TOP Ultra (and associated RPW capability) and OrthoPulse Ultra 100
Provides acceptable warranty coverage
Provide Items 1 and Item 2 simultaneously
Demonstrates authorized distribution (OEM provided letter or documentation)
Submission Deadline and Questions
Submission Deadline: September 29, 2026 by 7 PM Eastern Time
Quotes must be emailed to: sherrye.harris@va.gov.
Questions are due no later than September 28, 2026 3:00 PM Eastern Time to: sherrye.harris@va.gov.
Attachments/LinksContact InformationHistoryContracting Office Address- ONE VA CENTER
- TOGUS , ME 04330
- USA
Primary Point of Contact- Sherrye Harris
- Sherrye.Harris@va.gov
- Phone Number 774-826-4827
Secondary Point of Contact
- Sep 24, 2026 08:13 pm EDTCombined Synopsis/Solicitation (Original)
- Commodity Codes
-
- FSC 65Medical, Dental, and Veterinary Equipment and Supplies
- NAICS 334510Electromedical and Electrotherapeutic Apparatus Manufacturing
- Related bids
-
Sep 25, 2026 [Combined Synopsis/Solicitation (Original)] 6515--DUOLITH Acute Care Shockwave Therapy Device - 518-26-4-7480-0062
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
RFR 248431 Medical instrument...
Bid Solicitation: BD-24-1031-LSH00-LSH01-97662 Responses Due in 2703 Days, 20 Hours, 16 Minutes Header
Commonwealth of Massachusetts
Bid Due: 6/29/2031
RFR_185127 Diagnostic Imaging...
Bid # Alternate Id Buyer Description Purchase Method Bid Opening Date Bid Holder
State Government of Massachusetts
Bid Due: 9/30/2027