Public Safety Fuel Site Renovation
Project Information
- Bid Title
- Public Safety Fuel Site Renovation
- Issuing Agency
- Charlotte County
- Location
- Florida
- Published Date
- Jan 29, 2026
- Closing Date
- Feb 26, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- 26-229
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
File No:
26-229
Description:
Public Safety Fuel Site Renovation
Contact:
Kimberly.Chamberlain@charlottecountyfl.gov
File number:
20260229
Due Date:2/26/2026 3:00:00 PMNotice:Package:Registered Vendors Notified:Presubmittal Sign-in:Tabulation:Recommendation:Addendum:Commodity Codes:
05585, 40509, 46020, 55770, 56047, 57833, 72004, 72041, 90662, 91439, 92574, 92845, 95850, 99245, 99265
- Attachment Preview
-
PURCHASING DIVISIONCharlotte County Administration Center18500 Murdock Circle, Suite 344Port Charlotte, Florida 33948-1094Phone 941.743.1378Fax 941.743.1384TO: PROSPECTIVE PROPOSERSDATE: JANUARY 29, 2026RE: ADDENDUM #1, RFP NO. 20260229, PUBLIC SAFETY FUEL SITE RENOVATIONPROPOSAL DUE DATE: 3:00 p.m. (EST), FEBRUARY 26, 2026Firms are hereby notified that this addendum shall be made a part of the above-named proposal and contractdocuments. The following are issued to revise/clarify the proposal and contract documents, and these items shallhave the same force and effect as the original proposal and contract documents. Proposals to be submitted on theabove-specified date at Purchasing shall conform to the revisions and clarifications as listed herein.ITEM #1 REVISIONThe two (2) existing above-ground storage fuel tanks that are being replaced is a 5,200-gallon diesel tank and a500-gallon unleaded tank.ITEM #2 QUESTIONS/ANSWERSQ1: How many dispensers / fueling points for each tank?A1: We want two (2) dispensers or double handled per pump.Q2: Do you need high flow for the diesel dispensers? 22gpm or 50gpm?A2: We want 22gpm flow.Q3: Any tractors or trucks with saddle tanks which would require satellite dispenser.A3: There are not any tractors or trucks with saddle tanks.Q4: Hose length?A4: We want the hose length to be at least 25 feet.Q5: High hose hangers or reels?A5: YesQ6: Canopy? If yes, size?A6: There will be no canopy.Q7: For the above ground piping would Charlotte County want all stainless-steel pipe or black iron pipe with paint?A7: Black iron pipe with paintQ8: ATG connected to fuel Management?A8: Not necessaryQ9: Ladder or stairs with catwalks on the tanks?A9: YesQ10: Painted steel, galvanized, or aluminum?A10: GalvanizedQ11: Full length cat walks? If not how long?A11: Full LengthQ12: Both tank cat walks connected or independent?A12: IndependentQ13: Would you want the dispenser to be Super stainless steel or powder coated?A13: Powder coatedQ14: Remote fill, would you want that to be stainless steel?A14: Yes, stainless steelQ15: Would you like one (1) concrete slab to fit both tanks or two (2) separate concrete slabs for the tanks?A15: If possible but maybe dictated by the placement to accommodate the site location.Q16: Is the tank build wanting to be all above ground pipe or would you want a transition sump and undergroundpipe?A16: All above groundQ17: I understand we are to remove and reuse fuel management system, but would you be in need of a tank gaugesystem like Omntec. If you have an Omntec existing, you will only need to change out the probes and a few sensorsto be added such as interstitial sensors and sump sensors if wanted.A17: The system will need a Omntec monitoring with all necessary probes.Q18: Are the 3000- and 500-gallon tanks existing ul 142 or 2085?A18: The existing tanks are 5,200-gallon and 500-gallon as stated above in the revision. These tanks are double-walled fire-resistant concrete tanks.Q19: What are the required bollard specifications?A19: We are requiring 6” galvanized pipe bollards (7’ overall length).ITEM #3 ADDITIONThe existing 5,200-gallon diesel storage tank also runs the generator for the Fire/EMS Maintenance Building sowhen installing the new diesel storage tank, provisions can be made to tie in existing genset for the MaintenanceBuilding or recommendation for auxiliary supply diesel fuel tank for generator.This addendum is binding and is to be considered as if contained within the original proposal documents of RFPNo. 20260229. Firms are required to acknowledge receipt of this addendum on their proposal forms.Kimberly A. Corbett, C.P.M., CPPBSenior Division Manager - PurchasingKC/kchcc: ClerkFile
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
800 MHz Radio Tower Demo Boca...
Description: 800 MHz Radio Tower Demo Boca Site Department: Facilities Dev & Ops
Palm Beach County
Bid Due: 3/25/2029
800 MHz Radio Tower Demo Boca...
Description: 800 MHz Radio Tower Demo Boca Site Department: Purchasing Buyer: Jonathan Silva
Palm Beach County
Bid Due: 9/26/2029