ITB 6897 Walk-in Freezer Replacement
Project Information
- Bid Title
- ITB 6897 Walk-in Freezer Replacement
- Issuing Agency
- City of Johnson City
- Location
- Tennessee
- Published Date
- Apr 9, 2026
- Closing Date
- Apr 27, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Submittals due by April 27, 2026 at 11am ET.
Site visit required before bid submission.
Attached Document :
ITB 6897 -Walk-in freezer replacement project SHHS.pdf
- Attachment Preview
-
INVITATION TO BIDCITY OF JOHNSON CITY, TENNESSEEWWW.JOHNSONCITYTN.ORG/PURCHASINGPURCHASING DEPARTMENT423/975-2711Bid Name / NumberDue Day / Date / TimeBid Location / Mail AddressBid Contact / TelephoneBid Issue DateProject locationFOBPayment TermsAnticipated Award Date:Walk-in Freezer Replacement / #6897Monday / April 27, 2026 /11:00 AM (at which time it will be opened publicly)Johnson City Purchasing Department, Debbie Dillon-Director,209 Water Street, Johnson City, TN 37601Hannah Upchurch; UpchurchH@jcschools.org; purchasing@johnsoncitytn.orgApril 9, 2026Science Hill High Schoool,1509 John Exum Pkwy, Johnson City TN 37604Destination, freight prepaid and allowed - Johnson City, TNNet 30May 11th .Bidder is responsible for completing the remaining portion of this bid documentLUMPSUMDESCRIPTIONProvide all labor, materials and equipment to remove existing walk-in freezerand install new including re-use of existing (2) refrigeration systems as per $_______________the attached price sheet, specifications & diagram.COMPLETED CONTRACTORS ENVELOPE FORM MUST BEATTACHED TO OUTERMOST ENVELOPE.Project must be completed by July 15, 2026. Specify: ___________________NOTE: MANDATORY ON-SITE VISIT PRIOR TO BID SUBMISSION.CALL FOR AN APPOINTMENT. 423-434-5228.Solicitations will be opened publicly via a simultaneous virtual and in-person meeting.Join Zoom Meeting: ITB# 6897 - Walk-in Freezer Replacement Project virtual bid opening; Meeting ID: 8282810 5070 ; Passcode: 495214.If you do not have access to a webcam, or you have no audio with your system, you may call this number tojoin: (646) 518-9805. Any issues accessing the zoom web meeting please call 423.975.2711 for directassistance.Bidder’s Reminder: ● Bid to be signed by authorized company representative; ● Verify prices, extensions and total as correctBy signing this document, the undersigned hereby agrees to the prices and all other terms and conditions, including the attached Sealed SolicitationGeneral Terms & Conditions and the City’s Requirements for Bids, Requests for Proposals, and Contracts Between the City of Johnson City and OtherParties and the Requirements of the Iran Divestment Act and Non-Boycott of Israel Act (Sealed Solicitations General Terms & Conditions #16 & #19)contained in this bid and associated documents relating to this bid and will furnish items as specified if this bid is accepted. By submission of this bid,each bidder and each person signing on behalf of any bidder certifies, and in the case of a joint bid each party thereto certifies as to its own organization,under penalty of perjury, that to the best of its knowledge and belief that each bidder complies pursuant to T.C.A. § 12-12-106 & T.C.A. § 12-4-119.SUBMITTAL INSTRUCTIONS:Place signed bid response in a sealedenvelope plainly identified on the outside withvendor name and bid name and number.Vendor responsible for delivery to JohnsonCity Purchasing Dept., Debbie Dillon- Director,209 Water Street, Johnson City, TN 37601 on orbefore the bid opening date and time.Firm Name____________________________________________By________________________________________________PRINTED & SIGNEDAddress______________________________________________________________________________________________Telephone_____________________________________________E-Mail________________________________________________THIS SHEET MUST BE SIGNED AND RETURNED WITH BID TO BE VALIDITB# 6897 – WALK-IN FREEZER REPLACEMENT PROJECTBIDDERS INSTRUCTIONS1. INSURANCEThe attached Insurance Checklist (which includes a section for the Insurance agent tofill-out) and General Contract Form shall be completed and returned with the bidpackage. Successful vendor shall provide certificate of insurance, as specified, prior tocontract release by Purchasing.2. DRUG FREE WORKPLACEAll bidders must execute the enclosed Drug Free Workplace Affidavit to verifycompliance with TCA 50-9-113 and return same with bid response. Failure to complywith this requirement will declare that bid non-responsive.SECTION I – PURPOSE OF THE DRUG & ALCOHOL TESTING PROGRAMThe City of Johnson City recognizes its responsibility to provide safe and efficientoperations for our employees, our citizens and the general public. Our commitmentto provide safe and efficient operations is shown by the implementation of programsand procedures which ensure compliance with appropriate safety measures, as wellas the letter and intent of all applicable laws and regulations. There is sufficientevidence to conclude that the use of illegal drug/alcohol; drug/alcohol dependenceand drug/alcohol abuse seriously impairs an employee’s performance and generalphysical and mental health. The illegal possession and use of drugs, alcohol and/ornarcotics by employees of the City is a crime in this jurisdiction and is clearlyunacceptable. Therefore, the City of Johnson City has adopted this written policy toensure an employee’s fitness for duty as a condition of employment; to ensure thedrug tests and alcohol tests are conducted on safety-sensitive positions in thecategories of: pre-employment, random testing, suspicion testing, and return-to-dutytesting.To comply with TCA Title 50 Chapter 9 Part 1, all bidders and/or those proposing todo service with the City must have a testing program of the same or better than therequirements of the City of Johnson City.3. STATE CONTRACTORS LICENSEBidder must be a licensed contractor in the State of Tennessee, as required by theContractor's Licensing Act of 1994, State of Tennessee. The attached “ContractorsEnvelope Form” must be completed and attached to the outermost bid submittalenvelope. A copy of Bidder’s State Contractor’s License shall be included withbid package.4. ADDENDAIn the event it becomes necessary to revise any part of this bid, addenda will be issuedto all known interested parties and posted on the City’s website. It’s the bidder’sresponsibility to check prior to submitting. Any verbal communications are not bebinding.5.REQUIREMENTS FOR BIDS, REQUEST FOR PROPOSALS AND CONTRACTSThis Proposal, and any response to it, includes the City’s “Requirements for Bids,Requests for Proposals, and Contracts, etc.” and the “Sealed Solicitation GeneralTerms and Conditions” attached hereto and set forth herein as if verbatim.6.LICENSES, FEES AND PERMITSThe Contractor is responsible for furnishing the proper licenses, fees, and permitsrequired by law to do business in the City of Johnson City in completion of therequirements stated herein. All work shall be done in accordance with the latestbuilding codes, state and federal laws relative to this project.7.CRIMINAL HISTORY AFFIDAVITAll bidders must execute the attached Criminal History Affidavit. Contractor shallcomply with Tennessee Code Annotated Section 49-5-413, which requires allcontractors to conduct a criminal history records check conducted by the TennesseeBureau of Investigation and the Federal Bureau of Investigation on each employeeprior to permitting the employee to have contact with students or enter school groundswhen students are present.8.JOBSITE VISITContractor responsible for accurate measurements and fit. Jobsite visit required priorto bidding. Contact Hannah Upchurch to make an appointment for inspection.ITB# 6897 – WALK-IN FREEZER REPLACEMENT PROJECT FOR SCIENCE HILL HIGHSCHOOLSPECIFICATIONSAll equipment shall be in strict compliance with standards of all local, state, and federal regulationsincluding the National Sanitation Foundation, and in full compliance with Public Health Regulations ofState of Tennessee. Each unit shallhave a e "seal of approval" label from the National SanitationFoundation. Other standards that apply including but not limited to ANSI; NFPA, ASME and AGA, asapplicable.All equipment bid is to be based on the attached custom build diagram with no substitutions.Remove and properly dispose of existing walk-in freezerInstall new custom built walk-in Freezer per diagram.19' 0" x 23' 0" x 7' 6" HighInsulation: 4" DURATHANE, all‐urethane foamed‐in‐place (Class 1)Exterior: Stucco AluminumInterior Walls: Stucco AluminumInterior Ceilings: White Stucco AluminumInterior Floors: 1/8" Aluminum TreadplateFreezer with Floor(1) 48" x 76" Flush Mounted Entrance Door(s), with hardware, Pilotlight & switchassembly, vapor proof light & dial thermometer. NSF LISTED(1) Interior Ramp(1) Door(s) with (3) Hinges per door(1) Weather tight light switch(1) 36"H 1/8" Aluminum Treadplate kickplates int & ext(1) Concealed locking bar(s)(1) Backup frame heater wire(s)(1) Vinyl strip curtain(s)(1) Sloped weather roof with vinyl weather cap(1) Pressure relief vent(s)(6) 48" LED light fixture(s) w/ bulbsAluminum coved base on exposed exteriorCeiling & floor SpliceInterior beam & post supportTrim: (1) Row of vinyl bumper rails on exposed exteriorRe-use existing refrigeration systems (2)Includes all electrical connections, run all drains, start-up, making necessary adjustments and finish readyfor use.IMPORTANT!Thermo-Kool Standard Floor: Thermo-Kool’s standard floor panelscan handle 600 lbs. of stationary load. NO ROLLING TRAFFIC.Proper cleaning practices must be followed to ensure durability andwarranty compliance, including avoiding water exposure or wet mopping.These drawings represent our understanding of therequirements of your order. We submit them to you forthe purpose of securing complete approval of sizes,finishes, framing, insulation, dimensions, specifications, andinterpretations. The return of these drawings to uswith instructions to proceed, or subsequent instructionsto that effect, shall constitute complete approval.Approved byDate4.00"TRIMWARNINGDO NOT EXPOSE CARTONED ORSTACKED PANELS TO MOISTUREOR HIGH HUMIDITY CONDITIONSDURING STORAGE. STAINING OROXIDIZING OF METAL SKINS MAYOCCUR.NOTICETHIS ORDER CANNOT BE PLACED INTO PRO-DUCTION UNTIL WE RECEIVE FINAL APPROVEDDRAWING AND SPECIFICATIONS. THE DATE OFRECEIPT CAN AFFECT YOUR PROMISED DELI-VERY DATE.THIS THERMO-KOOL WALK-IN WILL BE MANUFACTUREDTO UL & NSF REQUIREMENTS. THERMO-KOOL ACCEPTSNO LIABILITY FOR LOCAL CODE REQUIREMENTS OFWHICH THERMO-KOOL HAS NOT BEEN MADE AWARE INWRITING PRIOR TO FABRICATION.ACROVYN GUARDCONTINUOUS ALUM.EXTRUSIONFASTENERS 16" O.C.MAX.EXTRUDEDALUMINUM/VINYLBUMPER RAILVERIFYVINYL BUMPER RAILSBACKUPWALK-IN WALLFIN. FLOORRWALK-IN PANELThermo-Kool/Mid-South Industries, Inc.R-14781ASSIFICUSRBUILDING UNITS1F68USASURFACE BURNING CHARACTERISTICSMATERIAL DETAILSFLAMESMOKESPREAD DEVELOPEDALUMINUM PANELS, PAINTED OR UNPAINTED, 5" OR LESS15300-400GALVANIZED OR STAINLESS STEEL PANELS, PAINTED OR UNPAINTED,5" OR LESS20 450-OVER 500CORE MATERIAL, 6" THICK20250PULL DOWN RATE TO 45° F IS UNRESTRICTED.AFTER 45 ° F, PULL DOWN RATE SHOULD BERESTRICTED TO 10° F PER/ 24 HOUR PERIOD."THERMO-KOOL WALK-IN COOLERS AND FREEZERSCOMPLY WITH 2021 INTERNATIONAL ENERGYCONSERVATION CODE (IECC), SECTION C403.11"NOT APPROVEDQUOTATION SUBMITTALREVISED* VERIFY HEIGHT AND LOCATION OF BUMPER RAILS.WEATHERCAP FLASHES DOWN 6"SILICONE (BY OTHERS)TRIM ATTACHMENT(BY THERMO-KOOL)WEATHERCAP FASCIA BAR W/ COVERThermo-Kool Standard Floor: Thermo-Kool’s standard floor panels can handle 600 lbs. of stationary load. NOROLLING TRAFFIC. Proper cleaning practices must be followed to ensure durability and warrantycompliance, including avoiding water exposure or wet mopping.WALK-IN DOORADJUSTABLE SWEEPGASKETHEAVY GA. THRESHOLDANTI SWEAT HEATERLOW DENSITY URETHANEHIGH DENSITY URETHANEOUTSIDEWALL6" ALUMINUM COVED BASEON EXPOSED EXTERIOR4" CONCRETE SUB SLABINT. RAMPWATERTIGHT SEAL FORMEDBY ASPHALT PAPER OR6 MIL POLYETHYLENESHEETS. JOINTS SEALED.(BY OTHERS)SECTIONTHRU DOORSECTION THRUOUTSIDE WALLFASCIA BAR W/ COVER19'-0" [228.00"]18'-4" [220.00"]EXPOSEDPOSTLED LIGHT FIXTURELED LIGHT FIXTURE4.00"1" FLANGE(TYP)THESE TWO ENDSOVERLAP FORADJUSTMENTSLOTS FOR 3/8" BOLTS THATATTACH COLUMN TO THE BEAMISOMETRIC VIEWLED LIGHT FIXTUREEXPOSEDPOSTINTERIORBEAMFREEZERW/FLOORLED LIGHT FIXTURELED LIGHT FIXTUREEXPOSEDPOSTVINYL BUMPERRAILS10'-8" [128.00"]LED LIGHT FIXTURE#1832 PR VENTLED LIGHTDIAL THERM4'-0" [48.00"]TRIM4'-4" [52.00"]Exterior Metal SkinInsulated PrefabPanel# 8 X 3/4" S/SADJUSTABLE THRAUTSSSHHAEPAEDDSMSBEAM COVER6061-T6 ALUMINUM STRUCTURALWIDE FLANGE BEAM 6" X 4" X .1903/4" PLYWOOD BACKUP3/4" PLYWOOD BACKUPSHIM IF REQUIRED3/8 Washer3/8 X 2" LAG BOLT 23" O.C.BEAM COVERFLANGE1/2" BRASS RIVET NUT THREADEDFOR A 3/8" BOLT, RIVET NUTEMBEDDED IN BEAM3/8" X 1 1/2" MACHINE BOLTW/ WASHER (4-PER POST)3" SCHEDULE 406061-T6 ALUMINUM PIPE(3 1/2" DIA.)3/8 X 2" LAG BOLT(4-PER POST)Q47248-25OVERALL DIMENSIONSFINISH-ExteriorWIDTH 19'-0"DEPTH 23'-0"HEIGHT 7'-6"Interior (walls and ceiling)5426 Ga. Stucco Embossed Galv. Steel.040 Stucco Aluminum20 Ga. Type 304 #3 Finish Stainless SteelWhite Stucco AluminumWhite Smooth AluminumWALLSCEILING26 Ga. Stucco Embossed Galv. Steel.040 Stucco Aluminum20 Ga. Type 304 #3 Finish Stainless SteelWhite Stucco AluminumWhite Smooth AluminumWhite Stucco Galv.White Stucco Galv.White Smooth Galv.FINISH-Interior FloorWhite Smooth Galv.Built-in by others. (Breaker strip must be under all wall panels including partitions)4" x 2" Vinyl U-Channel Screeds14 Ga. Bright Galvanized SteelWall Anchors4 1/4" Foam Screeds16 Ga. Stainless Steel.SEE DETAIL BELOWSmooth Aluminum1/8" Treadplate Aluminum Foamed-In-PlaceTHERMO-KOOL WALK-IN FLOOR PANELS ARE DESIGNED TO WITHSTAND UNIFORMLY DISTRIBUTED STATIONARYLOADS OF 600 LBS. PER SQUARE FOOT. THERMO-KOOL'S WARRANTY DOES NOT COVER DAMAGE DUE TO PALLETJACKS, MOBILE CARTS, MOBILE SHELVING, FORK LIFTS, OR ANY OTHER FORM OF ROLLING TRAFFIC. A CONC.WEARING FLOOR MUST BE INSTALLED ON TOP OF THE WALK-IN FLOOR PANELS FOR THIS APPLICATION.SECTION FASTENERS-Thermo-Kool cam type Insta-LokINSULATION-4" thickness "Foamed-in-place" urethane-DURATHANE CONSTRUCTION CLASS IOUTDOOR INSTALLATIONVinyl weather roof W/ Facia Bar & CoverSloped Foam__5_2_9__SQ. FT. OF 4-MIL POLYETHYLENE (BETWEEN SLOPED FOAM & VINYL WEATHERCAP)INDOOR INSTALLATIONELECTRICAL-All wiring contained within the door sections is 115/60/1Ø. Connections to this and all other lightsand refrigeration supplied by others.UNEXPOSED CONDUIT - Wiring stubs out top of panels 8"EXPOSED CONDUIT - Wiring terminates in a field service box at top of panelsENTRANCE DOOR-Flush infitting type with poly vinyl magnetic gasket and vinyl sweep gasket on bottom edge.Heater cables are built in around door opening to prevent frost accumulation and sweating. Ext. has athermometer, indicating light and toggle switch. Interior has LED light. Hinges are cam action type.* Door finishes will be the same as adjacent panels unless specified otherwise under Door Accessories.DOOR SIZE & QTYHARDWARE(1) 48" x 74"( ) 30" x 76"( ) 36" x 78"1238-C LATCH, (2) 1346 PERFORMER ADJUSTABLE HINGES, DOOR CLOSER1238-C LATCH, (3) 1346 PERFORMER ADJUSTABLE HINGES, DOOR CLOSERSWINGRHLHDOOR ACCESSORIES( ) 14" x 14" Peep Window(s)W/ HEATED FRAME & GLASS( ) 14" x 24" Peep Window(s)W/ HEATED FRAME & GLASS(1) WEATHERTIGHT LIGHT SWITCH (SEE ELEVATION)1/8" ALUMINUM TREADPLATE INT/EXT KICKPLATES 36" HIGH(1) CONCEALED LOCKING BAR(S)(1) BACKUP FRAME HEATER WIRE(S) (INSTALLED BUT NOT OPERATIONAL)(1) VINYL STRIP CURTAIN TO FIT THE ABOVE DOOR SIZENOTE: 74" IS MAX DOOR HEIGHT FOR THIS WALK-IN.MISCELLANEOUS EQUIPMENT( ) Lights (NOT MOUNTED) 1 AMP EACH(1) Interior Floor RampExterior Floor Ramp# 1825 LE Heated Pressure Relief Vent .5 AMPS EACH# 1830 Heated Pressure Relief Vent .5 AMPS EACH(1) # 1832-4 Heated Pressure Relief Vent .5 AMPS EACHTrim & Enclosures (see detail)FLAT VINYL WEATHER CAP(6) 48" LED LIGHT FIXTURE(S) W/ BULBS (.4 AMPS)6" HIGH ALUMINUM COVED BASE ON EXPOSED EXTERIORCEILING & FLOOR SPLICEINTERIOR BEAM AND POST SUPPORT (SEE DETAILS)(2) 3" x 3" x 7'-6" TRIM PIECE(S)(1) ROW OF VINYL BUMPER RAILS ON 19'-0" EXPOSED SIDE (SHIPPED LOOSE)REFRIGERATION-AircooledWatercooledBy OthersVINYL WEATHERCAPWALK-IN CEILINGVINYL WEATHERCAPWALK-IN CEILING* SEAL INTERIOR & EXTERIOR OFALL CONDUIT PENETRATIONS TOPREVENT CONDENSATION.1346 SPRINGLOADED HINGEDOOR CLOSER19'-0" [228.00"]#1832 PR VENTDIAL THERMHAZARD PLACARDWEATHER TIGHT LIGHT SWITCH1238-C LATCHCONCEALED LOCKING BARVINYL BUMPERRAILSTREADPLATEKICKPLATE6" HIGH ALUMINUMCOVED BASEFRONT ELEVATIONDOOR SECTION 2.5 AMPSNOTE: IF REFRIGERATION IS NOT SUPPLIED WITHWALK-IN, BASED ON AN AMBIENT OF 100 DEGREES F,FOR NSF APPLICATIONS AT STANDARD HOLDINGTEMPERATURES FOR A FREEZER THE BTU RATING SHALLBE 21250 .ITEM # 1DATE3-25-2026REV. BYEKYCONTROL KIT-The following controlsindicated with a mark are included.Condensing unit indoorCondensing unit outdoorSide Mounted Self ContainedTop Mounted Self ContainedQuick ConnectRemoteTop MountedExpansion valveDryerSight glassTemperature controlPump down solenoid valvePrewired, Preassembled RemoteFreezer Time ClockPressure controlSuction line vibration eliminatorWinter controlCrankcase heaterCondensing unit coverCoil Mounting KitRNOTES: Aircooled condensing units should be placed in a well ventilated area with a minimum of1000 CFM's per/H.P.Evaporator drain connections by others.NOTE: THERMO-KOOL recommends a 1" min. clearance between walk-in & building walls.REVISIONS DESCRIPTIONREMOVED SLOPE FOAM AND ADDED FLAT WEATHER ROOFNOTE: THIS DRAWING, AND ALL DRAWINGS ORSPECIFICATIONS SUBMITTED BY THERMO-KOOL,AND REPRODUCTIONS THEREOF IN WHOLE OR INPART SHALL REMAIN THE LEGAL PROPERTY OFMID-SOUTH INDUSTRIES, INC., SUBJECT TO RECALLAT ANY TIME AND SHALL NOT BE USED FORINSTALLATIONS OR PRODUCTION BY OTHERS EXCEPTBY OUR SPECIAL PERMISSION IN WRITING.Walk-in panels manufactured underPatent # 5,424,118.Thermo-Kool®Mid-South Industries, Inc.Laurel Mississippi 39441FAX 601/649-0558P.O. Box 989Phone 601/649-4600SUBJECTWALK-IN REFRIGERATIONFORSCIENCE HILL HIGH SCHOOLJOHNSON CITY, TNDR. BYEKYDATE3-25-2026CH. BY/SCALE3/8"=1'-0"DWG. NO.Q47248-25SHEET NO.1 OF 1
- Commodity Codes
-
- NAICS 333415Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.