APPLICABLE CODE: 2022 CBCMEP COMPONENT ANCHORAGE NOTEALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON THEDSA-APPROVED CONSTRUCTION DOCUMENTS. THE FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THEFORCE AND DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2022 CBC SECTIONS 1617A.1.18 THROUGH 1617A.1.26 ANDASCE 7-16 CHAPTERS 13, 26, AND 30:1. ALL PERMANENT EQUIPMENT AND COMPONENTS.2. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G., HARD WIRED) TO THE BUILDINGUTILITY SERVICES SUCH AS ELECTRICITY, GAS OR WATER. “PERMANENTLY ATTACHED” SHALL INCLUDE ALL ELECTRICALCONNECTIONS EXCEPT PLUGS FOR 110/220 VOLT RECEPTACLES HAVING A FLEXIBLE CABLE.3. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT WHICH IS HEAVIER THAN 400 POUNDS OR HAS A CENTER OF MASS LOCATED4 FEET OR MORE ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT IS REQUIRED TOBE RESTRAINED IN A MANNER APPROVED BY DSA.THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE BUT NEEDNOT DEMONSTRATE DESIGN COMPLIANCE WITH THE REFERENCES NOTED ABOVE. THESE COMPONENTS SHALL HAVE FLEXIBLECONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. FLEXIBLECONNECTIONS MUST ALLOW MOVEMENT IN BOTH TRANSVERSE AND LONGITUDINAL DIRECTIONS:A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVING A CENTER OF MASS LOCATED 4 FEET OR LESS ABOVE THEADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT.B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PERFOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.THE ANCHORAGE OF ALL MECHANICAL, ELECTRICAL AND PLUMBING COMPONENTS SHALL BE SUBJECT TO THE APPROVAL OFTHE DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE OR STRUCTURE ENGINEER DELEGATED RESPONSIBILITY ANDACCEPTANCE BY DSA. THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN ANCHOREDIN ACCORDANCE WITH THE ABOVE REQUIREMENTS.MEP DISTRIBUTION SYSTEM BRACING NOTE FOR PIPING, DUCTWORK AND ELECTRICAL CONDUIT:PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTSPRESCRIBED IN ASCE 7 SECTION 13.3 AS DEFINED IN ASCE 7 SECTIONS 13.6.5, 13.6.6, 13.6.7 AND 13.6.8 AND 2022 CBC, SECTIONS 1617A.1.24,1617A.1.25 AND 1617A1.26.THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE IDENTIFIED DISTRIBUTION SYSTEMS ARE AS NOTEDBELOW. THE MEP DESIGN PROFESSIONAL ENGINEER RESPONSIBLE FOR CONTENT ON THESE SHEETS HAS VERIFIED THAT THE DESIGNMETHODS IDENTIFIED BELOW ARE IN ACCORDANCE WITH DSA IR 16-13.MECHANICAL PIPING (MP), MECHANICAL DUCTS (MD), PLUMBING PIPING (PP), ELECTRICAL DISTRIBUTION SYSTEMS (E):MPMDPPE X OPTION 1: PROJECT-SPECIFIC DESIGN.GENERAL NOTES1. VISIT JOB SITE AND VERIFY EXISTING CONDITIONS PRIOR TO BID.2. THE ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE2022 CALIFORNIA ELECTRICAL CODE AND ALL APPLICABLE LOCALORDINANCES. WHERE PLANS CALL FOR A HIGHER STANDARD THANAPPLICABLE CODES, THE PLANS SHALL GOVERN.3. CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATIONSSHALL BE DETERMINED IN THE FIELD TO SUIT FIELD CONDITIONS.4. ALL ELECTRICAL EQUIPMENT, APPLIANCES AND LIGHTING FIXTURES SHALL BELISTED BY A RECOGNIZED TEST LAB AND BEAR THAT LABEL OF APPROVAL.5. CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT ALL MATERIAL ANDEQUIPMENT FOR THIS WORK UNLESS OTHERWISE NOTED.6. FURNISH DISCONNECT SWITCHES AT REMOTE MOTORS.7. ALL SPACES AS INDICATED ON PANELS OR SWITCHBOARDS SHALL BECOMPLETE WITH HARDWARE AND BUSSING FOR FUTURE BREAKER ORSWITCH.8. CHECK ARCHITECTURAL PLANS FOR DOOR SWINGS BEFORE INSTALLINGSWITCH OUTLETS.9. GROUNDING AND BONDING SHALL BE PER CODE PLUS ANY ADDITIONALPROVISIONS SPECIFIED OR SHOWN ON DRAWINGS.10. ALL CONDUIT RUNS SHALL CONTAIN A CODE SIZED GREEN GROUND WIRE.11. THESE PLANS ARE NOT COMPLETE UNTIL APPROVED BY THE AUTHORITYHAVING JURISDICTION.12. ALL CONDUCTORS SHALL BE IN CONDUIT.13. ALL CONDUCTORS SHALL BE COPPER WITH TYPE THHN/THWN INSULATION.14. COORDINATE WITH SERVING ELECTRICAL UTILITY COMPANY AND MAKEPROVISIONS FOR ELECTRICAL SERVICE ACCORDINGLY. INCLUDE ALLSERVICE COSTS AND UTILITY COMPANY CHARGES IN BID.15. COORDINATE WITH SERVING TELEPHONE UTILITY COMPANY AND MAKEPROVISIONS FOR TELEPHONE SERVICE ACCORDINGLY. INCLUDE ALLSERVICE COSTS AND ANY UTILITY COMPANY CHARGES IN BID.16. COORDINATE WITH SERVING CABLE TELEVISION COMPANY AND MAKEPROVISIONS FOR CABLE TELEVISION ACCORDINGLY. INCLUDE ALLSERVICE COSTS AND ANY UTILITY COMPANY CHARGES IN BID.17. ALL PERMITS SHALL BE OBTAINED AND PAID FOR BY CONTRACTOR.SYMBOLSCONDUIT EXISTINGCONDUIT CONCEALED IN WALL OR CEILINGCONDUIT CONCEALED UNDER FLOOR OR BELOW GRADECONDUIT STUBBED OUT AND CAPPEDCONDUIT TURNED UPCONDUIT TURNED DOWNHATCH MARKS INDICATE NO. OF #12 WIRES IN CODE SIZEDCONDUIT (3) MAX. IN 1/2" C., (5) MAX. IN 3/4" C.,A-3(8) MAX. IN 1"C., NO MARKS = 2#12HOME RUN: LETTER INDICATES PANEL, NUMBER(S) INDICATESCIRCUIT(S).SAWCUTGROUND CONNECTIONDISTRIBUTION SWITCHBOARD OR PANELPANEL, BRANCH CIRCUIT TYPE, SURFACE AND FLUSHSIGNAL TERMINAL CABINET, SURFACE & FLUSHLINEAR SURFACE FIXTURE2OUTLET DATA: BAR INDICATES WALL MOUNT, LETTER INDICATESaSWITCH CONTROL, NO. INDICATES CIRCUIT.SURFACE FIXTURE ON FLUSH OUTLET.RECESSED FIXTURE WITH JUNCTION BOX FOR THRU WIRINGEXIT LIGHT WITH ARROWS AS SHOWN ON PLANS, WALL ANDCEILING MOUNT.LOW LEVEL EXIT SIGN, +6" AFF, +4" FROM DOOR JAMBALIGHT FIXTURE DESIGNATION, LETTER INDICATES TYPE,100NO. INDICATES WATTAGE. SEE FIXTURE SCHEDULE.FC1MGFIMECHANICAL EQUIPMENT DESIGNATION.SEE MECHANICAL DRAWINGS.SPECIAL RECEPTACLE - SEE PLANMETERFLUSH FLOOR RECEPTACLERECEPTACLE, DUPLEX, 15A, 125V, NEMA 5-15R +18" U.N.O.DUPLEX RECEPTACLE MTD. ABOVE BACKSPLASHDUPLEX RECEPTACLE W/LOWER HALF SWITCHEDGROUND FAULT CIRCUIT INTERRUPTING RECEPTACLEDOUBLE DUPLEX RECEPTACLECEILING RECEPTACLERECEPTACLE, DUPLEX, 20A, 125V, NEMA 5-20R +18" U.N.O.JJUNCTION BOX 4" SQUARE, 1-1/2" DEEP U.N.O.TTHERMOSTAT F.B.O. +48"2MOTOR, NO. INDICATES HORSEPOWERCLOCK OUTLET +7'-6" U.N.O.DISCONNECT SWITCH, NON-FUSEDFDISCONNECT SWITCH FUSED HORSEPOWER RATED OR SIZED ASNOTEDCOMBINATION MAGNETIC STARTER WITH DISCONNECT SWITCH ANDFUSESMAGNETIC MOTOR STARTER W/OVERLOADS IN EACH PHASEDDIMMER W/INTEGRAL "ON-OFF" SW.PUSHBUTTONPCPHOTOCELLSDSMOKE DETECTOR, INTERCONNECTED W/ BATTERY BACK-UPSCCOMBINATION SMOKE AND CO DETECTOR, INTERCONNECTEDW/ BATTERY BACK-UPTELEPHONE/COMPUTER/DATA OUTLET, TWO GANG BOX W/1 GANGCOVERPLATE & GROMMETED OPENING +18" U.N.O.TVCABLE TV OUTLET +18" U.N.O.MMOTION SENSORSEXISTING SWITCHSSINGLE POLE SWITCHS2DOUBLE POLE SWITCH QUIET TOGGLE TYPE RATED ATS3THREE WAY SWITCH20A, 120/277V A.C. +42" U.N.O.SPSWITCH W/PILOT LT.SMMANUAL MOTOR STARTERFACPGFILSTMLOw/C.O.W.P.F.B.O.U.N.O.N.E.C.N.I.C.(E)(N)(R)(RL)S/MU/GCWPAFFHACRN.L.FIRE ALARM CONTROL PANELGROUND FAULT CIRCUIT INTERRUPTINGLABOR SAVING TANDEMMAIN LUGS ONLYWITHCONDUIT ONLYWEATHERPROOFFURNISHED BY OTHERS, INSTALL & CONNECTUNLESS NOTED OTHERWISENATIONAL ELECTRICAL CODENOT IN CONTRACTEXISTINGNEWREMOVERELOCATESURFACE MOUNTUNDERGROUNDCOLD WATER PIPEABOVE FINISHED FLOORHEATING AND AIR CONDITIONING RATEDNIGHT LIGHTCIRCUIT BREAKERNOTE: NOT ALL SYMBOLS SHOWN ARE USED ON THIS PROJECT.HEADQUARTERS OFFICE:99 S. Lake Avenue, Suite 300Pasadena, CA 91101P 323.543.8300E-Mail: fm-pasadena@flewelling-moody.comANTELOPE VALLEY OFFICE:1035 West Lancaster BoulevardLancaster, California 93534P 661.949.0771E-Mail: fm-lancaster@flewelling-moody.comPEELECTRICAL ENGINEERINGLIGHTING DESIGNCA REGISTRATION NO E13083EXTERIOR FINISHESAND NEW FENCING ATTHE EDUCATION SERVICE CENTER1051 SOUTH "A" STREETOXNARD, CA 93030OXNARD SCHOOL DISTRICTSYMBOLS, NOTES& SCHEDULES321010 - 28 - 2025BC-E-1BID CLARIFICATION DRAWING 12/1/2025(E) F.H.ACAC(E) MILL BUILDINGACACCONNECT KEYPAD & INDUCTIONLOOP BACK TO GATE OPERATORSEEAE2MOTORIZED GATECONNECT GATEOPERATOR(N)1-1/4"C.W/DATA CABLING(E) HVACENCLOSURE(N)A-22, 3/4"C.W/2#10,1#10GND.(E) F.H.AC(E)DATA ROOM(E)PANEL "A"(E) EDUCATIONAL SERVICE CENTER(E) STORAGEBUILDINGACAC(E) F.H.AC(E) F.H.ELECTRICAL SITE PLANSCALE: 1"=30'-0"ALLEYACGATE OPERATOR3/4"C. POWER1-1/4"C. DATA(NOT IN SCOPE)(NOT IN SCOPE)(NOT IN SCOPE)(NOT IN SCOPE)(E) BUILDING(NOT IN SCOPE)(E)IDF(E) BUILDING(NOT IN SCOPE)(E) BUILDING(NOT IN SCOPE)(E) BUILDING(NOT IN SCOPE)(N) 1-1/4"C. W/ DATA CABLINGKEY PAD3/4"C. W/ LOW VOLTAGE CABLE3/4"C. W/LOW VOLTAGECABLEINDUCTIONLOOPENLARGED PLANASCALE : NONEE-2FLUSH PULLBOX, UNOFINISHED GRADE3"1/2" GALVINIZED STEELCHECKER PLATEH/20 LOADING CENTER3"COVERING BOTTOM3"SIZE PER PLAN3"METAL LATHEOPEN BOTTOM12"GRAVELFLUSH PULLBOX DETAILBSCALE : NONEE-2HEADQUARTERS OFFICE:99 S. Lake Avenue, Suite 300Pasadena, CA 91101P 323.543.8300E-Mail: fm-pasadena@flewelling-moody.comANTELOPE VALLEY OFFICE:1035 West Lancaster BoulevardLancaster, California 93534P 661.949.0771E-Mail: fm-lancaster@flewelling-moody.comPEELECTRICAL ENGINEERINGLIGHTING DESIGNCA REGISTRATION NO E13083(E) BUILDING(NOT IN SCOPE)CONNECT GATEOPERATORB11 x 17. SEEE2(E) HAND BALLWALL(NOT IN SCOPE)(E) BUILDING(NOT IN SCOPE)(E)LOADCENTER "X"CONNECT KEYPAD & INDUCTIONLOOP BACK TO GATE OPERATORS. "A" S T(N)MOTORIZED GATEASEEE2(N)X-12, 3/4"C.W/2#10,1#10GND.EXTERIOR FINISHESAND NEW FENCING ATTHE EDUCATION SERVICE CENTER1051 SOUTH "A" STREETOXNARD, CA 93030OXNARD SCHOOL DISTRICTELECTRICALSITE PLANNorth3210BC-E-210 - 28 - 2025BID CLARIFICATION DRAWING 12/1/2025LIMITED LEAD BASED PAINT SURVEYDATE:November 6, 2025ATTENTION:Oxnard School DistrictSUBJECT PROPERTY:1051 South A StreetOxnard, California 93030INTRODUCTION:On November 4, 2025, Insight Environmental, Inc. performed a Limited Lead-Based PaintSurvey at the subject property. The purpose of this survey was to determine the presence orabsence of lead-based paint in the proposed work areas of the property prior to the disturbanceof building materials. This Survey was limited to the accessible building materials within thework areas identified by the client. This survey was conducted by Casey Bressler (CSST #22-7273 & CDPH Sampling Technician LRC-00010923) under the supervision of RobertAugspurger (CAC #19-6515 & CDPH Inspector/Assessor #LRC-0009459).LEAD GUIDELINES:The Department of Housing and Urban Development (HUD) Guidelines and the EPA’sRenovation, Repair, and Paint Rule consider lead levels of 0.5 percent lead by weight (5000parts per million (ppm) or mg/kg) or greater; alternatively, an action level of 1 milligram persquare centimeter or greater, as lead-based paint which may be a potential hazard. In LosAngeles County, an action level of 0.7 milligrams per square centimeter has beenestablished. In 1978, the Consumer Product Safety Commission (CPSC) banned lead-containing paint containing greater than 0.06% (600 ppm) lead in residential paint.Cal-OSHA Certified Asbestos Consultant / DHS Lead Certified Inspector AssessorCertified Residential Indoor Environmentalist / Radon Measurement Technician / NIOSH 582 Microscopist
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Follow Castle Creek Bridge Repair Active Contract Opportunity Notice ID 127EAW26Q0039 Related Notice
AGRICULTURE, DEPARTMENT OF
Bid Due: 7/08/2026
Pavement repair, drainage, MG...
Pavement repair, drainage, MGS, Mod lighting systems and TMS.Details Event ID 04-1W7104 Format/Type:
State Government of California
Bid Due: 8/04/2026