2025 Fire Prevention System Inspections

Project Information

Bid Title
2025 Fire Prevention System Inspections
Issuing Agency
City of Valdez
Location
Alaska
Published Date
Oct 17, 2024
Closing Date
Nov 15, 2024
Government Level
State & Local
Status
Closed
Original Source
Join to Access Full Details
Project Description
Bid Title: 2025 Fire Prevention System Inspections
Category: Current Projects
Status: Open
Description:

Bid Posting Date: October 17, 2024
Project: 2025 Fire Prevention System Inspections
Quotes Due: Quotes will be accepted until 2:00 PM local time on Friday, November 15, 2024

This project includes, but is not necessarily limited to:

  1. Fire Alarm Panel Inspections:
    1. Inspect all fire alarm panels and certify that they are in good functioning order.    Note any problems or issues that need to be corrected.
    2. Certify (Tag) all panels with appropriate documentation as required by code.  If deficiencies in panel operation are found, perform corrections if possible.  If correction of the problem is not possible, notify the city maintenance staff of the need to have certified technicians hired to correct the problem.  Any problem to a panel that needs to be corrected may be billed as an extra charge to the City of Valdez at pre-agreed hourly rate.  If repairs are not possible during the inspection trip, vendor will provide the City of Valdez with a proposal for correcting the problem at a later date.
    3. Send an annual documentation report of panel certifications to the City of Valdez within 30 days of inspection.
  1. Fire Suppression Systems Inspections:
    1. Inspect all sprinkler systems for correct operation as per code.
    2. Maintain accurate records of benchmark inspections, including but not limited to: annual inspections, pressure gauge calibrations and or replacement, five-year interior pipe inspections, and ten-year dry sprinkler replacement.   Notify the City of these additional benchmark services in the appropriate years.
    3. Correct any minor deficiencies found to suppression systems that can be accomplished during the inspection trip.  Additional work to correct found deficiencies may be billed to City at hourly rates.   If repairs are not possible during the inspection trip, vendor will provide the City of Valdez with a proposal for correcting the problem at a later date.
    4. Tag sprinklers with annual inspection tag.
    5. Send an annual documentation and report of sprinkler certifications to the City of Valdez within 30 days of inspection.
  1. Backflow Preventer Inspections:
    1. Inspect all backflow preventers with required inspection and tag with annual inspection certification tag.
    2. Correct any problems with backflow preventer that can be corrected within the inspection visit.  Additional work may be charged to the City of Valdez at agreed rates.  If correction to backflow preventer is not possible during inspection trip, vendor will provide the City of Valdez with a proposal for correcting the problem at a later date.
    3. Send an annual documentation and report of backflow preventers to the City of Valdez within 30 days of inspection.
  1. Annual Fire Extinguisher Inspections:
    1. Vendor will inspect all fire extinguishers on-site and verify all extinguishers meet all code requirements.
    2. Vender will notify the city maintenance of any defective extinguishers so the extinguisher can be replaced.
    3. The City of Valdez will provide the Vendor with an accurate list of all the fire extinguishers with accompanying serial number for tracking.
    4. Vendor will keep accurate records of annual inspections of existing fire extinguishers and shall notify the City of Valdez when six year and hydro tests are due.
    5. In the event of the need for six-year inspections, it is expected that Vender will perform the required emptying, refilling and recharging extinguishers at the building site and immediately replacing the extinguishers back into service with appropriate tags.
    6. When hydro testing is required, the vendor shall notify the City of Valdez in advance so a process of replacement can be negotiated in a way that the City of Valdez can maintain the required number of functioning fire extinguishers in every building.
    7. Any fire extinguishers that are unavailable to be inspected during the scheduled visit can be charged an extra charge to the city to re-inspect.
    8. Send an annual extinguisher report to the City of Valdez within 30 days of inspection.
  1. Semi-Annual /Annual Hood Inspections and chemical suppression systems:
    1. Inspect and clean kitchen hoods twice a year and tag as per code.
    2. Inspect hood fire suppression system as per code and tag.
    3. Keep records of pressure vessel inspections and replace or recharge as needed.
    4. If deficiencies are found, Vendor should try to correct during inspection visit at regular hourly rate.  If correction is not possible on inspection trip, Vendor will provide a proposal for a return trip to complete necessary work.
    5. Send inspection reports to the City of Valdez within 30 days of inspection.


Any question regarding this project should be directed to Stanley Porritt , Facilities Maintenance Manager.

Quotes will be accepted until  2:00 PM local time on Friday, November 15, 2024 , at the office of the Facilities Maintenance Manager, 555 West Egan Drive,  PO Box 307, Valdez, Alaska 99686. Quotes will be accepted via email, fax, mail, or in person.

Questions can be directed to Stanley Porritt , City of Valdez Project Manager.

Bid documents may also be downloaded from the links below.

The City reserves the right to waive any irregularities or informalities in a quote, to reject any and all quotes without cause, and to re-solicit for quotes.

Current minimum prevailing wage rates as published by the Alaska Department of Labor must be paid if required by law.

Requirements of the Alaska Employment Preference (AS 36.10) must be met.

The City of Valdez encourages disadvantaged, minority and women-owned firms to respond and is available to assist said firms in learning how to do business with the City.

The City of Valdez “ Standard Specifications and Standard Details ” shall be used.

Reference Documents

Publication Date/Time:
10/17/2024 8:00 AM
Closing Date/Time:
Open Until Contracted
Contact Person:
Stanley Porritt
Project Manager
PH: (907) 835-5412
Fax: (907) 835-5410
Business Hours:
M-F 8-4:30pm
Fax Number:
(907) 835-5410
Related Documents:
Commodity Codes
  • NAICS 541350Building Inspection Services
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.

Government Bids

Empower Your Bidding Strategy

Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.

  • Access an extensive database of bids, including comprehensive local and state opportunities.
  • Receive customized alerts for the bids that matter most to your business.
  • Explore detailed specifications to ensure precise and competitive submissions.
  • Gain a competitive edge with up-to-date information and exclusive opportunities.

See Also

Audiometric Booth

Follow Audiometric Booth Active Contract Opportunity Notice ID W91ZRU_SS_AudiometricBooth Related Notice Department/Ind. Agency

DEPT OF DEFENSE

Bid Due: 7/08/2026

Request for Offers: Stair Pre...

Follow Request for Offers: Stair Pressurization System Inspections and Testing at FAA fFacilities

TRANSPORTATION, DEPARTMENT OF

Bid Due: 7/10/2026