REQUEST FOR QUOTES SANITARY SEWER REPAIR AT 1608 Broadway
Project Information
- Bid Title
- REQUEST FOR QUOTES SANITARY SEWER REPAIR AT 1608 Broadway
- Issuing Agency
- Gary Sanitary District
- Location
- Indiana
- Published Date
- Oct 29, 2026
- Closing Date
- Nov 19, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Project ID:
Title: REQUEST FOR QUOTES SANITARY SEWER REPAIR AT 1608 Broadway
Addenda: 0
Release Date: 10/29/2026
Due Date: 11/19/2026
REQUEST FOR QUOTES SANITARY SEWER REPAIR AT 1608 BroadwayFollowRequest For ProposalEngineering67012 , 91063 , 91345 , 91381Project ID: 2026-RFP-063Release Date: Thursday, October 29, 2026· Due Date: Thursday, November 19, 2026 2:00pmPosted Thursday, October 29, 2026 2:21pmAll dates & times in Central Time - ChicagoDraft Response No Bid20 days, 18 hours, 16 minutesOverview
Post Information
Posted At:Thu, Oct 29, 2026 2:21 PM
Sealed Bid Process:Yes (Bids Sealed / Pricing Sealed)
Private Bid:No
SummarySanitary Sewer Repair at 1608 Broadway in the City of Gary, IN.
Furnish all labor, materials, tools, equipment, superintendence, and all necessary incidentals for the repair of sanitary sewer pipe.
Manhole No. 507 Sewer Invert Depth is ± 13.7
Manhole No. 508 Sewer Invert Depth is ± 13.9
POINT REPAIR
Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507.
CIPP LINING
-
- CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507.
BackgroundPOINT REPAIR
- Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507.
- Contractor shall ensure pipe penetrations are sealed and watertight.
- Contractor shall connect new pipe to existing good pipe with a watertight connection. Connect new pipe to existing PVC pipe with neoprene rubber coupling with stainless steel straps or coupling provided by the manufacturer and approved by the owner. When adjoining new pipe to existing, the maximum space between the abutting pipes shall be 1/8 inches or less.
CIPP LINING
- CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507.
- The CIPP liner shall extend 4-inches into existing manholes.
- The Contractor shall install a pre-liner and/or perform chemical grouting of infiltration points as necessary
Timeline
Release RFP Date:October 29, 2026Question Submission Deadline:November 12, 2026, 12:00pmProposal Submission Deadline:November 19, 2026, 2:00pm -
- Commodity Codes
-
- NAICS 237110Water and Sewer Line and Related Structures Construction
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
PMC2703722060 Brown County St...
Project name and number PMC2703722060 Brown County State Park Fire and Security 2-Year
State Government of Indiana
Bid Due: 1/20/2027
Quantity Purchase Award (QPA)...
Description: Quantity Purchase Award (QPA) Agreement for Repair Parts for INDOT Paint Trucks
State Government of Indiana
Bid Due: 12/07/2026