6665--Multi-gas detection equipment

Project Information

Bid Title
6665--Multi-gas detection equipment
Issuing Agency
VETERANS AFFAIRS, DEPARTMENT OF
Location
Maryland
Published Date
Apr 17, 2026
Closing Date
Apr 30, 2026
Government Level
Federal
Status
Closed
Ref. #
36C24526Q0466
Original Source
Join to Access Full Details
Project Description
Follow
6665--Multi-gas detection equipment
Active
Contract Opportunity
Notice ID
36C24526Q0466
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Apr 17, 2026 11:22 am EDT
  • Original Response Date: Apr 30, 2026 09:00 am EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jun 29, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6665 - HAZARD-DETECTING INSTRUMENTS AND APPARATUS
  • NAICS Code:
    • 334519 - Other Measuring and Controlling Device Manufacturing
  • Place of Performance:
    Perry Point VA Medical Center Perry Point, , MD 21902
    USA
Description
Sources Sought Notice

Sources Sought Notice

Page 4 of 4
Sources Sought Notice
*= Required Field
Sources Sought Notice

Page 1 of 4
DESCRIPTION
REQUEST FOR INFORMATION

This RFI is being sent solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.

The Department of Veteran Affairs, located at Perry Point VA Medical Center located at 361 Boiler House Rd, Perry Point, Maryland, 21902 is seeking a multi-gas detection equipment.
The associated North American Industrial Classification System (NAICS) code for this procurement is 334519- Other Measuring and Controlling Device Manufacturing, size standard is 600 employees.
Salient Characteristics:
Equipment/Supply/Instrument Dimensions:

Height up to 4.1in
Width up to 2.3in
Depth up to 2.4in
Weight up to 8.5oz

Display/Monitor/Screen:

Height up to 1.8in
Width up to 1.8in

Power Requirements:

Voltage (AC/DC) (compliant to U.S electrical outlets)
Power Cable Length 4ft
Grounded
Battery Powered/Backup
Rechargeable, Expendable
Hours to Recharge: up to 4hrs
Working Volume/ Product Performance/Additional requirements:

Operating hours: up to 4hrs

Accessories/Consumables:

Filters

Warranty and Parts/Service Requirements:

Minimum Warranty Months/Years: Lifetime Warranty
Parts/Service/Support options: Lifetime Warranty

Cleaning Instructions (If sterilization is required):

Easy access to all panels for access to components needing sterilization purposes if needed
Cleaning cloth for the LCD monitor.

Other pertinent information that describes the item, material or service needed:

Monitor that allows the user to monitor up to five gases simultaneously and manage worker safety. Sensor configuration to include, at a minimum:
Oxygen (O2)
Carbon Monoxide (CO)
Hydrogen Sulfide (H2S)
Hydrogen Cyanide (HCN)
Lower Explosive Limit (LEL)

Multi-gas monitor that connects workers for live monitoring to instantly receive real-time location data, man-down alarms, and gas alerts.

Responses:

The response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
Does vendor offer an annual service plan, Yes or No?

If Yes:
What does the plan cover?
Does plan cover software updates only?
Does the plan cover parts repair or replacement only?
Does the plan cover both software and parts?

Vendor are requested to provide documentation that shows information on their service plan.

Is the service provided by the OEM or a subcontractor?

Full name and address of company
DUNS number/ CAGE Code/ SAM UIE
Business Size
Manufacturer or Distributor
If distributor provide full name, business size and address of manufacturer.
Country of Origin designation for all products MUST COMPLETE THIS SECTION
Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.
Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
Authorized Distributor Letter Certified by OEM with a current date.

Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
Attachments/Links
Contact Information
Contracting Office Address
  • 8849 International Drive Suite 215
  • LINTHICUM , MD 21090
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 17, 2026 11:22 am EDTSources Sought (Original)
Commodity Codes
  • FSC 66Instruments and Laboratory Equipment
  • NAICS 334519Other Measuring and Controlling Device Manufacturing
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.

Government Bids

Empower Your Bidding Strategy

Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.

  • Access an extensive database of bids, including comprehensive local and state opportunities.
  • Receive customized alerts for the bids that matter most to your business.
  • Explore detailed specifications to ensure precise and competitive submissions.
  • Gain a competitive edge with up-to-date information and exclusive opportunities.

See Also

UV LIGHT CURING SYSTEM ANTON ...

Follow UV LIGHT CURING SYSTEM ANTON PAAR MCR 502 WESP STRESS CONTROLLED SHEAR

COMMERCE, DEPARTMENT OF

Bid Due: 6/10/2026

Vacuum Pumps and Controllers

Follow Vacuum Pumps and Controllers Active Contract Opportunity Notice ID 1333ND26QNB030179 Related Notice

COMMERCE, DEPARTMENT OF

Bid Due: 6/05/2026