Spirit Elementary - Upgrade HVAC Bldg. 7
Project Information
- Bid Title
- Spirit Elementary - Upgrade HVAC Bldg. 7
- Issuing Agency
- Volusia County Schools
- Location
- Florida
- Published Date
- Mar 4, 2026
- Closing Date
- Mar 24, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Project No. 2648250
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Spirit Elementary - Upgrade HVAC Bldg. 7 - Project No. 2648250
Mandatory Prebid Meeting: March 3, 2026 at 3:00 PM Bid: March 24, 2026 at 2:00 PM Project Bid Documents: Plans
Project Manual
Prebid Sign-in SheetsEstimate: $310,648 Consultant: TLC Engineering Solutions, Inc.
Jim Mullen
(321) 877-4260Owner: VCS Project Manager
Mike Semon
(386) 947-8786Bid Status: Active - Attachment Preview
-
VOLUSIACOUNTY SCHOOLS"LEADING WITH GRACE AND RESPECT"THE SCHOOL BOARD OF VOLUSIACOUNTY FLORIDA200 North Clara AvenueDeLand, Florida 32720SPIRIT ELEMENTARYUPGRADE HVAC BLDG. 7VCS Project NO. 2648250SCHOOL BOARDMEMBERSRUBEN COLÓNKRISTA GOODRICHDONNA BROSEMERJAMIE HAYNESJESSICA THOMPSONCARMEN J. BALGOBINBOARD CHAIRVICE BOARD CHAIRMEMBERMEMBERMEMBERSUPERINTENDENTSEAL1500 MEADOWLARK DRDELTONA, FL 32725DESCRIPTION OF WORKREPLACEMENT OF THE 60 TON CHILLER SERVING BUILDING 7.ADD ALTERNATE REPLACEMENT OF THE PUMPS SERVING THE 60 TON CHILLER.Architect's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe Florida Building Code.BUILDING DATAA. SURVEY PARCEL IDB. LEGAL DESCRIPTIONC. OCCUPANCY TYPED. CONSTRUCTION TYPEE. RISK CATEGORYF. AUTOMATIC SPRINKLERG. BUILDING AREAH. BUILDING HEIGHTI. OCCUPANT LOADXXXXXXXXXTYPE XXXXXXXXXXXXXXXXXXLOCATION MAPENGINEERS & CONSULTANTSMEPTLC ENGINEERING SOLUTIONS7370 CABOT CT, SUITE 103MELBOURNE, FL 32940321.636.0274JIM MULLENJIM-MULLEN@TLC-ENG.COMWWW.TLC-ENGINEERS.COMSheet NumberG001COVER SHEETSHEET MANAGERSheet NameE001ELECTRICAL SYMBOLS, LEGEND, AND ABBREVIATIONSE002ELECTRICAL GENERAL NOTES AND INDEXE101ELECTRICAL PLANE501ELECTRICAL DETAILSE601ELECTRICAL PANEL AND EQUIPMENT SCHEDULESED101ELECTRICAL DEMO PLANM001M101MD101M601MECHANICAL SYMBOLS. LEGEND, NOTES, AND INDEXMECHANICAL PLANMECHANICAL DEMOLITION PLANMECHANICAL CONTROLSNOT TO SCALEConstruction Documents 12/01/2025ENGINEER OF RECORDJIM MULLENDESIGNED BYLUKE ADAMSDRAWN BYLUKE ADAMSISSUE DATE12/01/2025AE PROJECT NUMBER525260SHEET TITLECOVER SHEETDRAWING NO.G001ELECTRICAL SYMBOL LEGENDBASIC MATERIALSSYMBOLDESCRIPTIONDEVICE ABBREVIATION TAGS:6CPOKE-THRU WITH 6" CORE DRILL8CPOKE-THRU WITH 8" CORE DRILL4GFOUR-GANG FLOOR BOX6GSIX-GANG FLOOR BOX8GEIGHT-GANG FLOOR BOXAVDOUBLE DUPLEX RECEPTACLE WITH DEDICATED CIRCUIT FOR AV RACK OR CARTCRECEPTACLE CONTROLLED PER ASHRAE 90.1 (2010); PROVIDE POWER PACK FORRECEPTACLE CIRCUIT, TO BE CONTROLLED THROUGH LOCAL ROOM OCCUPANCYSENSOR(S); PROVIDE DEVICE WITH BLUE DOT OR UNIVERSAL POWER SYMBOLETREXISTING TO REMAINHHOSPITAL GRADEIGISOLATED GROUND (ORANGE DEVICE)RLRELOCATEDTRTAMPER RESISTANTTVRECEPTACLE MOUNTED ADJACENT TO TV OUTLET, COORDINATE HEIGHT W/ ARCHITECTUDUPLEX RECEPTACLE WITH (2) USB PORTSWPWEATHERPROOFOSWALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOROSDLDLVSVSPCJCEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSORDAYLIGHT SENSOR CEILING MOUNTEDDAYLIGHT SENSOR WALL MOUNTEDVACANCY SENSOR CEILING MOUNTEDVACANCY SENSOR WALL MOUNTEDPHOTOCELL, MOUNTED ON ROOF FACING NORTHNOTE: DIAGONAL MARKS INDICATED ON ANY DEVICE REPRESENTS DEVICECONNECTED TO EMERGENCY CIRCUIT (RED DEVICE FOR RECEPTACLE);TYPICAL FOR ANY DEVICE IN LEGENDSINGLE RECEPTACLEDUPLEX RECEPTACLETWO DUPLEX RECEPTACLES (QUAD) WITH COMMON COVERPLATEDUPLEX RECEPTACLE MOUNTED ABOVE COUNTERTWO DUPLEX RECEPTACLES (QUAD) WITH COMMON COVER MOUNTED ABOVE COUNTERDUPLEX RECEPTACLE; EACH RECEPTACLE ON SEPARATE CIRCUIT (PROVIDEBREAKER WITH 2-POLE COMMON TRIP HANDLE)SPLIT-WIRED CONTROLLED DUPLEX RECEPTACLEGFCI RECEPTACLE; "WP" INDICATES CAST METAL "IN-USE" WEATHERPROOF COVER,WEATHER-RESISTANT LISTEDTWO GFCI DUPLEX RECEPTACLES (QUAD) WITH COMMON COVERPLATEGFCI RECEPTACLE MOUNTED ABOVE COUNTERGNDGROUND BUS BAR, COPPERSPDSURGE PROTECTIVE DEVICEMOTOR CONNECTIONMDMOTORIZED DAMPER CONNECTIONVFDVARIABLE FREQUENCY DRIVEDDCDIRECT DIGITAL CONTROL PANELBASBUILDING AUTOMATION SYSTEM CONTROL PANELLCPLIGHTING CONTROL PANELSYMBOLDESCRIPTIONMHMANHOLEPBPULLBOXHHHANDHOLETTRANSFORMERATS30ARNF3R30AR20AF3RMCPAMPERERATING30/303RAUTOMATIC TRANSFER SWITCHNEMA RATING; NEMA 1 UNLESS OTHERWISE NOTEDNON-FUSED DISCONNECT SWITCH, RATING AS NOTEDNF = NON-FUSEDAR = AMPERE RATING OF SWITCH4X SS = NEMA 4X STAINLESS STEEL ENCLOSURENEMA RATING; NEMA 1 UNLESS OTHERWISE NOTEDFUSED DISCONNECTAF = AMPERE RATING OF FUSEAR = AMPERE RATING OF SWITCH4X SS = NEMA 4X STAINLESS STEEL ENCLOSURE# OF POLESNEMA RATING; NEMA 1 UNLESS OTHERWISE NOTEDCOMBINATION MAGNETIC MOTOR STARTER, SIZE AS NOTED, 3-POLE UNLESS OTHERWISENOTED4X SS = NEMA 4X STAINLESS STEEL ENCLOSURENEMA STARTER SIZESWITCHBOARD/ SWITCHGEAR/ DISTRIBUTION PANELBRANCH CIRCUIT PANELBOARD, OVER 240 VOLTS, SURFACE MOUNTEDBRANCH CIRCUIT PANELBOARD, OVER 240 VOLTS, FLUSH MOUNTEDBRANCH CIRCUIT PANELBOARD, UNDER 240 VOLTS, SURFACE MOUNTEDBRANCH CIRCUIT PANELBOARD, UNDER 240 VOLTS, FLUSH MOUNTEDCONDUIT CONCEALED ABOVE CEILING OR IN WALCONDUIT EXPOSEDCONDUIT CONCEALED IN SLAB, UNDERGROUND OR UNDER FLOORCONDUIT HOMERUN TO ELECTRICAL PANELUP CONDUIT TURNING UPDN CONDUIT TURNING DOWNCONDUIT STUBBED OUT OR UPCONDUIT CONTINUEDFLEXIBLE CONDUITCONDUIT SEAL-OFF FITTINGGROUND OR GROUND ROD AS NOTEDEXISTING TO BE REMOVED (HEAVY, DASHED LINE)EXISTING TO REMAIN (LIGHT, SOLID LINE)NEW (HEAVY, SOLID LINE)ABBREVIATIONSA/CAIR CONDITIONINGACALTERNATING CURRENTABV CLG ABOVE CEILINGADAAMERICANS WITH DISABILITIES ACTAFAMPERE FRAMEAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEAHUAIR HANDLING UNITAICAMPERE INTERRUPTING CAPACITYALALUMINUMAMPAMPEREANSIAMERICAN NATIONAL STANDARDS INSTITUTEASAAMERICAN STANDARDS ASSOCIATIONATAMPERE TRIPATSAUTOMATIC TRANSFER SWITCHAUXAUXILIARYAWGAMERICAN WIRE GUAGEBCBARE COPPERBILBASIC IMPULSE LEVELBASBUILDING AUTOMATION SYSTEMBMSBUILDING MANAGEMENT SYSTEMBRKR OR BKR BREAKERCCONDUIT OR RACEWAYCABCABINETCKTCIRCUITCBCIRCUIT BREAKERCBMCERTIFIED BALLAST MANUFACTURERSCATVCABLE TELEVISIONCCTVCLOSED CIRCUIT TELEVISIONCLECCLOCK EQUIPMENT CABINETCLGCEILINGCOCONDUIT OR RACEWAY ONLYCOAXCOAXIAL CABLECONDCONDUCTORCONNCONNECTIONCPUCENTRAL PROCESSING UNITCRTCATHODE RAY TERMINAL (VIDEO DISPLAY TERMINAL)CTCURRENT TRANSFORMERCUCOPPERCWCOLD WATERDCDIRECT CURRENTDDCDIRECT DIGITAL CONTROLDEGDEGREEDFDEMAND FACTORDISCDISCONNECTDISC SW DISCONNECT SWITCHDODRAW OUTDNDOWNDPSTDOUBLE POLE SINGLE THROWEDHELECTRIC DUCT HEATEREMTELECTRIC METALLIC TUBINGEOELECTRICALLY OPERATEDEOLEND OF LINEEORENGINEER OF RECORDETREXISTING TO REMAINEWCELECTRIC WATER COOLERFAFIRE ALARMFAAPFIRE ALARM ANNUNCIATOR PANELFATCFIRE ALARM TERMINAL CABINETFBCFLORIDA BUILDING CODEFCUFAN COIL UNITFLAFULL LOAD AMPERESFMFACTORY MUTUALFPUFAN POWERED UNITFTFEETGFGROUND FAULTGFAGROUND FAULT ALARMGFCIGROUND FAULT CIRCUIT INTERRUPTERGFRGROUND FAULT RELAYGND, GGROUNDHPHORSEPOWERHOAHAND-OFF-AUTOMATICHORIZHORIZONTALIBCINTERNATIONAL BUILDING CODEICINTERCOMICUINTENSIVE CARE UNITIECCINTERNATIONAL ENERGY CONSERVATION CODENOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT.ABBREVIATIONS (CONT.)IEEEINSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERSIESILLUMINATING ENGINEERING SOCIETYIMCINTERMEDIATE METAL CONDUITININCHESIPCEAINSULATED POWER CABLE ENGINEERS ASSOCIATIONITINSTANTANEOUS TRIPJB OR J-BOX JUNCTION BOXKCMILONE THOUSAND CIRCULAR MILSKVKILOVOLTKVAKILOVOLT AMPERESKWKILOWATTKWHKILOWATT HOURSLBSPOUNDSLEDLIGHT EMITTING DIODELPLIGHTNING PROTECTIONLTLIGHTLTGLIGHTINGLSIGLONG TIME, SHORT TIME, INSTANTANEOUS, GROUNDLSIALONG TIME, SHORT TIME, INSTANTANEOUS, ALARMLSILONG TIME, SHORT TIME, INSTANTANEOUSMAXMAXIMUMMCAMINIMUM CIRCUIT AMPSMCBMAIN CIRCUIT BREAKERMCCMOTOR CONTROL CENTERMDPMAIN SERVICE DISTRIBUTION PANELMICMICROPHONEMINMINIMUMMLOMAIN LUGS ONLYMOCPMAXIMUM OVERCURRENT PROTECTIONMSBMAIN SERVICE SWITCHBOARDMTDMOUNTEDMTGMOUNTINGMTRMOTORMTSMANUAL TRANSFER SWITCHMUXMULTIPLEX (TRANSPONDER) PANELMVAMEGA VOLT AMPSNNEUTRALNCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODENEMANATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNFPANATIONAL FIRE PROTECTION ASSOCIATIONNICNOT IN CONTRACTNFNON-FUSEDNLNON-LINEARNONORMALLY OPEN OR NUMBEROLOVERLOADOSHAOCCUPATIONAL SAFETY & HEALTH ADMINISTRATIONPPOLEPBPULLBOXPFPOWER FACTORPIVPOST INDICATOR VALVEPNLPANELPRPAIRPRIPRIMARYPTPOTENTIAL TRANSFORMERPVCPOLYVINYLCHLORIDEPWRPOWERREC, RECEPT RECEPTACLEREFREFRIGERATORRGS, GRC RIGID GALVANIZED STEEL CONDUITRLARUNNING LOAD AMPERESRMSROOT-MEAN-SQUARERPMREVOLUTIONS PER MINUTERTUROOF TOP UNITSCASHORT CIRCUIT AMPERESSDSMOKE DETECTORSECSECONDARYS/NSOLID NEUTRALSPDSURGE PROTECTIVE DEVICESPKRSPEAKERSPSTSINGLE POLE SINGLE THROWSSSTAINLESS STEELSSTSOLID STATE TRIPSTDSHORT TIME TRIPSWSWITCHSWBDSWITCHBOARDSWGRSWITCHGEARTELTELEPHONETTBTELEPHONE TERMINAL BOARDTTCTELEPHONE TERMINAL CABINETTVECTELEVISION EQUIPMENT CABINETTYPTYPICALUGUNDERGROUNDUONUNLESS OTHERWISE NOTEDULUNDERWRITERS LABORATORIESUTILUTILITYVVOLTVAVOLTAMPEREVARVOLT AMPERE REACTIVEVAVVARIABLE AIR VOLUMEVFDVARIABLE FREQUENCY DRIVEWWIREWPWEATHER PROOFXFMRTRANSFORMERXFRTRANSFERSEALENGINEER OF RECORDMONCEF M. HADIJIDESIGNED BYJOEY HOLTDRAWN BYJOEY HOLTISSUE DATE12/01/2025AE PROJECT NUMBER525260SHEET TITLEELECTRICAL SYMBOLS,LEGEND, ANDABBREVIATIONSDRAWING NO.E001ELECTRICAL DEMOLITION NOTESELECTRICAL GENERAL NOTES1. DEVICES, LIGHT FIXTURES AND EQUIPMENT SHOWN IN BOLD LINE TYPE ARE EXISTING TO BE DEMOLISHED; DEVICES, LIGHTFIXTURES AND EQUIPMENT SHOWN IN LIGHT (SCREENED) SOLID LINE TYPE ARE EXISTING TO REMAIN, UNLESS NOTEDOTHERWISE.2. EXISTING EQUIPMENT, LIGHT FIXTURES AND DEVICES SHOWN ARE BASED ON FIELD SURVEYS AND DRAWINGS PROVIDED BYTHE OWNER, AND ARE NOT NECESSARILY INCLUSIVE OF ALL EXISTING ELECTRICAL EQUIPMENT, LIGHT FIXTURES ANDDEVICES WITHIN PROJECT AREAS. IT IS THE INTENT THAT THE DEMOLITION PLANS PROVIDE A GENERAL KNOWLEDGE OF THEEXISTING CONDITIONS WITHIN THE PROJECT AREA. ANY DISCREPANCIES OR CONDITIONS NOT SHOWN ON THE PLAN SHALLBE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR REQUIREDELECTRICAL DEMOLITION WHETHER INDICATED ON THE PLANS OR NOT.3. EXISTING CIRCUITING SHOWN IS BASED ON RECORD DRAWINGS AND THE SURVEYED PANEL DIRECTORIES, WHERE THEYWERE AVAILABLE. THE ACTUAL CONDITIONS MAY VARY. ALL EXISTING CONDITIONS MUST BE VERIFIED BY THE CONTRACTORPRIOR TO BID. THE CONDITIONS SHOWN ARE INTENDED TO SHOW THE GENERAL LOCATIONS OF EXISTING DEVICES, LIGHTFIXTURES AND EQUIPMENT, WHERE SHOWN ON THE PLAN DRAWINGS, AND IN NO WAY RELIEVES THE CONTRACTOR FROMPROVIDING ANY AND COORDINATION NECESSARY TO COMPLETE THE NEW WORK. FIELD CONDITIONS SHALL GOVERN.4. WHERE EXISTING DEVICES ARE INDICATED TO REMAIN OR BE RELOCATED, ARE WITHIN THE SCOPE OF THIS PROJECT ANDEXISTING CIRCUITING INFORMATION IS UNAVAILABLE, CONTRACTOR SHALL PROVIDE CIRCUIT TRACING TO IDENTIFY PANELAND CIRCUIT SERVING THE DEVICE. THEY SHALL PROVIDE THAT INFORMATION TO THE ARCHITECT/ENGINEER PRIOR TOROUTING CONDUITS AND WIRING FOR THESE DEVICES AND EQUIPMENT.5. WHERE EXISTING DEVICES ARE TO REMAIN, CONTRACTOR SHALL EXTEND EXISTING CIRCUITING WHERE NECESSARY TOMAINTAIN CONTINUITY OF CIRCUIT.6. COORDINATE WITH THE OWNER FOR DISPOSAL OF ELECTRICAL ITEMS TO BE DEMOLISHED. OWNER SHALL HAVE THEOPTION TO RETAIN REUSABLE ITEMS SUCH AS COVERPLATES, RECEPTACLES, LIGHT FIXTURES, PANELBOARDS,TRANSFORMERS, ETC. NOT BEING USED IN THE FINISHED WORK. COORDINATE WITH THE OWNER PRIOR TO START OFDEMOLITION. PROPERLY AND LEGALLY DISPOSE OF EQUIPMENT AND MATERIALS BEING REMOVED.7. COORDINATE EXACT AREAS, WALLS, CEILINGS, ETC. TO BE DEMOLISHED WITH ARCHITECTURAL, STRUCTURAL, PLUMBING ANDMECHANICAL DEMOLITION PLANS.8. WHERE EXISTING DEVICES, LIGHT FIXTURES AND EQUIPMENT ARE INDICATED TO BE DEMOLISHED, REMOVE ASSOCIATEDBOXES, CONDUIT AND WIRING BACK TO SOURCE PANEL OR TO NEAREST JUNCTION BOX TO MAINTAIN CIRCUIT CONTINUITYOF DEVICES AND EQUIPMENT TO REMAIN. WHERE PANELS ARE TO REMAIN, TURN BREAKER TO "OFF" POSITION AND LABELTHE CIRCUIT AS "SPARE" ON THE PANEL DIRECTORY.9. AREAS OUTSIDE THE SCOPE OF CONSTRUCTION ARE TO REMAIN ENERGIZED. COORDINATE PHASING WITH CONSTRUCTIONMANAGER AND OWNER PRIOR TO DEMOLITION OF ANY ITEM WHICH MAY RESULT IN THE INTERRUPTION OF POWER.10. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EXTENT OF AREA REQUIRING DEMOLITION AND ADDITIONALINFORMATION ON ELECTRICAL DEMOLITION WITHIN THAT AREA. DISCONNECT ELECTRICAL SERVICE TO EQUIPMENT BEINGREMOVED. DEMOLITION SHALL BE PHASED AS REQUIRED BY DIVISION 1, OR AS DIRECTED BY THE OWNER.11. REMOVE CONDUIT LEFT EXPOSED BY REMOVAL OF WALLS AND CEILINGS IN REMODELED OR RENOVATED AREA. CAP BOTHENDS OF REMAINING CONDUIT IN WALL OR FLOOR WHERE CUT.12. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING OPENINGS IN EXISTING CONSTRUCTION AFTER REMOVAL OFEQUIPMENT, LIGHT FIXTURES, AND DEVICES UNLESS OTHERWISE NOTED ON ARCHITECTURAL PLANS. REPAIRS ARE TO BEDONE TO LOGICAL EDGES OF SURFACES AFFECTED AND SHALL MATCH THE IMMEDIATE ADJACENT AREAS IN CONSTRUCTION,MATERIAL, FIRE RATING, FINISH AND COLOR.13. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF WORK AND OBTAIN CLARIFICATIONSFROM ARCHITECT / ENGINEER IF NECESSARY.14. COORDINATE POWER INTERRUPTION WITH CONSTRUCTION MANAGER, OWNER, LANDLORD, AND UTILITY COMPANY (WHEREAPPLICABLE) AND DO NOT INTERRUPT POWER WITHOUT WRITTEN PERMISSION. PROVIDE A MINIMUM OF ONE WEEK'SWRITTEN NOTIFICATION PRIOR TO WHEN POWER IS DESIRED TO BE INTERRUPTED. CONTRACTOR SHALL INVESTIGATE ANDIDENTIFY LOADS TO BE AFFECTED BY THE REQUESTED INTERRUPTION. CONTRACTOR SHALL SUBMIT WRITTEN SEQUENCE OFSTEPS FOR EACH SHUTDOWN ALONG WITH THE ESTIMATED INTERRUPTION DURATIONS. MAKE ARRANGEMENTS TO MAINTAINPOWER TO EXISTING NECESSARY LIGHTING, DEVICES AND EQUIPMENT AS NEEDED AND REQUESTED BY THE OWNER PRIORTO COMMENCEMENT OF WORK.15. EXERCISE EXTREME CAUTION WHEN REMOVING / RELOCATING WIRING AND EQUIPMENT. IT IS THE CONTRACTOR'SRESPONSIBILITY TO ENSURE THAT OTHER WIRING DEVICES, EQUIPMENT AND LIGHT FIXTURES THAT MAY BE CONNECTED TOTHE SAME CIRCUIT REMAIN OPERATIONAL AND ACTIVE.16. INFORMATION INDICATED IN THE DEMOLITION PORTION OF THE CONTRACT DRAWINGS IS DIAGRAMMATIC IN NATURE. FIELDVERIFY ELECTRICAL CIRCUIT HOMERUNS TO ITEMS SCHEDULED OR NOTED TO BE DEMOLISHED AND PERFORM THE WORK ASINTENDED AND DEPICTED ON THE DRAWINGS OR DIRECTED IN THE FIELD.17. UPDATE EXISTING ELECTRICAL EQUIPMENT NAMEPLATES AND DIRECTORIES AS NECESSARY TO REFLECT FINAL AS-BUILTCONDITIONS AT THE END OF CONSTRUCTION.18. STORE ITEMS INDICATED TO BE RETURNED TO THE OWNER IN A DRY, CLEAN AND PROTECTED AREA. NOTIFY OWNER WHENITEMS ARE READY TO BE REMOVED.19. COORDINATE ANY ALTERATION AND CHANGES TO THE EXISTING ELECTRICAL SERVICE WITH THE LOCAL UTILITY COMPANYAND THE OWNER PRIOR TO COMMENCEMENT OF WORK.20. PROVIDE ANY NECESSARY REPROGRAMMING OF EXISTING BUILDING FIRE ALARM SYSTEMS TO DISABLE FIRE ALARM DEVICESTHAT ARE BEING DISCONNECTED AND REMOVED, AND FOR ANY NEW DEVICES THAT ARE ADDED, AS PART OF BID PRICE.21. CONDUITS SERVING OTHER SPACES THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTIONSO AS NOT TO CAUSE DISRUPTION TO THESE OTHER SPACES. ENSURE THAT CONDUITS, NEW OR EXISTING WITHIN THEPROJECT AREA ARE PROPERLY SUPPORTED IN ACCORDANCE WITH THE NEC.22. REMOVE ABANDONED OR UNUSED RACEWAYS INCLUDING CONDUCTORS, JUNCTION BOXES, SUPPORTS, AND FASTENERSTHAT ARE WITHIN THE PROJECT AREA PRIOR TO THE END OF CONSTRUCTION.GENERAL REQUIREMENTS1. THE DRAWINGS AND APPLICABLE SPECIFICATIONS SHALL BE CONSIDERED SUPPLEMENTARY, ONE TO THE OTHER AND ARECONSIDERED THE "CONTRACT DOCUMENTS". WORKMANSHIP, METHODS AND/OR MATERIALS DESCRIBED OR IMPLIED BY ONEAND NOT DESCRIBED OR IMPLIED BY THE OTHER SHALL BE PROVIDED, FURNISHED OR PERFORMED AS IF IT HAD APPEARED INBOTH SECTIONS. THE TERM "CONTRACT DOCUMENTS" DESCRIBED HEREIN IS NOT LIMITED SOLELY TO THE ELECTRICALPORTION OF THE DRAWINGS AND SPECIFICATIONS, BUT ENCOMPASSES THE DRAWINGS AND SPECIFICATIONS OF ALLDIVISIONS AS A WHOLE.2. THE DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EVERY DETAIL OF CONSTRUCTION, METHODS,MATERIALS AND EQUIPMENT, OR EXACT LOCATIONS, ROUTING, ETC. THEY INDICATE THE RESULT TO BE ACHIEVED BY THEASSEMBLAGE OF SEVERAL SYSTEMS FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. DO NOT SCALE THECONTRACT DOCUMENTS. COORDINATE EXACT EQUIPMENT LOCATIONS WITH THE ARCHITECTURAL, CIVIL, STRUCTURAL,MECHANICAL, PLUMBING, AND FIRE PROTECTION CONTRACT DOCUMENTS, AS WELL AS FIELD CONDITIONS, APPROVED SHOPDRAWINGS AND WORK OF OTHER DIVISIONS/TRADES.3. THE TERM "PROVIDE" USED IN THE CONTRACT DOCUMENTS INDICATES TO FURNISH AND INSTALL MATERIALS REQUIRED FORCORRECT INSTALLATION OF A COMPLETE SYSTEM, UNLESS SPECIFICALLY NOTED OTHERWISE.4. UNLESS NOTED AS EXISTING, ELECTRICAL SYSTEMS AND DEVICES INDICATED ON THE CONTRACT DOCUMENTS SHALL BE NEW,SHALL BE U.L. LISTED, AND SHALL BEAR A U.L. LABEL. WHERE NO U.L. LABEL OR LISTING IS AVAILABLE, THE MATERIAL SHALL BELISTED WITH AN APPROVED, NATIONALLY RECOGNIZED ELECTRICAL TESTING AGENCY AS DEFINED BY OSHA.5. PROVIDE EXPERIENCED, QUALIFIED AND RESPONSIBLE SUPERVISION FOR WORK REQUIRED BY THE CONTRACT DOCUMENTS.ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, TO THE SATISFACTION OF THEARCHITECT/ENGINEER AND OWNER.6. CARRY INSURANCE REQUIRED TO PROTECT AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THISPROJECT.7. GUARANTEE MATERIALS AND WORKMANSHIP ARE FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROMTHE DATE OF FINAL ACCEPTANCE BY THE ARCHITECT/ENGINEER AND OWNER, UNLESS NOTED OTHERWISE IN DIVISION 1. ATNO ADDITIONAL COSTS, PROVIDE THE CORRECTION OF ANY DEFECTS INCLUDING REPAIR OR REPLACEMENT.8. INCLUDE COSTS ASSOCIATED WITH PERMITS, LICENSES, FEES, INSPECTIONS, TESTING AND TEMPORARY POWER IN THE BIDPRICE, UNLESS NOTED OTHERWISE.9. IF HAZARDOUS MATERIALS ARE ENCOUNTERED, COMPLY WITH APPLICABLE RULES, REGULATIONS AND GUIDELINESCONCERNING REMOVAL, HANDLING, DISPOSAL AND PROTECTION AGAINST ENVIRONMENTAL EXPOSURE OR POLLUTION.PROVIDE DOCUMENTATION OF SAID COMPLIANCE.10. PROVIDE ELECTRONIC SUBMITTALS (PRODUCT DATA & SHOP DRAWINGS) FOR EACH MAJOR COMPONENT OF THE ELECTRICALSYSTEM FOR REVIEW BY THE ARCHITECT/ENGINEER AND OWNER. MAJOR COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO,RACEWAYS, BOXES, WIRE AND CABLE, EQUIPMENT, DEVICES, LIGHT FIXTURES, SWITCHGEAR, PANELBOARDS, CIRCUITBREAKERS, SAFETY SWITCHES, FIRE ALARM SYSTEM, ETC. SUBMITTALS ARE TO BE REVIEWED AND APPROVED BY THECONTRACTOR FOR CONFORMANCE WITH THE PROJECT REQUIREMENTS PRIOR TO SUBMITTING TO THE ARCHITECT/ENGINEER.ALLOW A MINIMUM OF TEN (10) BUSINESS DAYS FOR REVIEW BY ARCHITECT/ENGINEER, UNLESS NOTED OTHERWISE INDIVISION 1.11. THE ELECTRICAL PORTION OF THE CONTRACT DOCUMENTS ARE COORDINATED WITH THE DESIGN BASIS EQUIPMENTSPECIFIED BY DIVISION 26 AND OTHER DIVISIONS. WHERE THE CONTRACTOR ELECTS TO SUBSTITUTE A PRODUCT IN LIEU OFPROVIDING THE DESIGN BASIS, AND SAID SUBSTITUTION IS ACCEPTED BY THE ARCHITECT/ENGINEER AND OWNER, THECONTRACTOR SHALL MAKE CORRECTIONS TO THE ELECTRICAL SYSTEM NECESSARY IN ORDER TO ENSURE A COMPLETE ANDOPERATIONAL INSTALLATION OF THE EQUIPMENT AT NO ADDITIONAL COSTS. WHERE THE CONTRACTOR'S DESIGNSUBSTITUTION RESULTS IN THE NEED FOR THE ENGINEER TO REVISE THE CONTRACT DOCUMENTS, THE ENGINEER RESERVESTHE RIGHT TO REQUEST COMPENSATION FROM THE CONTRACTOR FOR SAID SERVICES.12. MAINTAIN A CURRENT AND ACCURATE SET OF PROJECT RECORD DOCUMENTS (AS-BUILTS) AT THE SITE THROUGHOUT THEDURATION OF THE PROJECT. RECORD DRAWINGS SHALL BE UPDATED EACH DAY TO REFLECT THE ACTUAL LOCATIONS, SIZES,ROUTING, ETC. OF EACH PORTION OF THE ELECTRICAL SYSTEM AFFECTED BY THIS WORK. A FINAL SET OF RECORDDOCUMENTS SHALL BE ISSUED TO THE ARCHITECT/ ENGINEER FOR REVIEW AND THEN SUBMITTED TO THE OWNER WITHIN 30DAYS AFTER THE DATE OF FINAL ACCEPTANCE. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION INCLUDINGSINGLE LINE DIAGRAM, POWER RISER DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM, SITE PLANS ANDELECTRICAL FLOOR PLANS, DETAILS, PANEL SCHEDULES, ETC.13. PROVIDE AN OPERATING AND MAINTENANCE MANUAL TO OWNER PRIOR TO THE FINAL ACCEPTANCE. THE MANUAL SHALLINCLUDE, AS A MINIMUM, (1) SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OFEQUIPMENT REQUIRING MAINTENANCE, (2) PROVIDE TWO OPERATIONS AND MAINTENANCE MANUALS FOR EACH PIECE OFEQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS AND METHOD OF OPERATION FOREQUIPMENT SHALL BE CLEARLY IDENTIFIED, AND THE NAME, PHONE NUMBER AND ADDRESS OF AT LEAST ONE QUALIFIEDSERVICE AGENCY.14. INCLUDE IN BID COSTS FOR EXCAVATION, SAW CUTTING, DIRECTIONAL BORING, CORE DRILLING, BACKFILLING, SURFACERESTORATION, REPAIR OF FINISHES, ETC. THAT IS REQUIRED IN ORDER TO MEET THE PROJECT REQUIREMENTS.15. INCLUDE IN BID COSTS ASSOCIATED WITH TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR USE BY TRADES DURINGCONSTRUCTION. REMOVE TEMPORARY POWER AT THE COMPLETION OF THE PROJECT. OBTAIN AND PAY FOR REQUIREDPERMITS FOR TEMPORARY POWER. ENGINEER OF RECORD SHALL BE PROVIDED WITH ADDITIONAL COMPENSATION FROM THECONTRACTOR WHERE SIGNED & SEALED DRAWINGS ARE REQUESTED BY THE CONTRACTOR TO THE ENGINEER OF RECORD IFREQUIRED BY THE AHJ FOR THE TEMPORARY POWER.16. PRIOR TO TRENCHING IN ANY AREA LOCATE, IDENTIFY, PROTECT AND DOCUMENT UTILITY LINES LOCATED WITHIN THEPROJECT BOUNDARY. FOR LOCATING SITE UTILITIES, CONTACT LOCAL MUNICIPALITIES AND UTILITIES AT LEAST 48 HOURSPRIOR TO DIGGING.17. INCLUDE IN BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF WASTE MATERIALS GENERATED BY THIS PROJECT INACCORDANCE WITH LOCAL, STATE AND FEDERAL RULES, REGULATIONS AND GUIDELINES APPLICABLE. COMPLY FULLY WITHAPPLICABLE STATUTES REGARDING MERCURY-CONTAINING DEVICES, AND WITH LOCAL, STATE AND FEDERAL APPLICABLEGUIDELINES AT THE TIME OF DISPOSAL. PROVIDE OWNER WITH WRITTEN CERTIFICATION OF ACCEPTED DISPOSAL.GROUNDING1. FIRE PROTECTION PIPING SHALL NOT BE USED FOR GROUNDING.2. FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE AN EQUIPMENT GROUND CONDUCTOR. METAL RACEWAYS SHALL NOT BEUSED AS THE SOLE EQUIPMENT GROUND.3. WHERE A PHASE CONDUCTOR IS INCREASED IN SIZE DUE TO VOLTAGE DROP, THE EQUIPMENT GROUND CONDUCTOR SHALL BEINCREASED IN SIZE PROPORTIONATELY.COORDINATION1. VERIFY AND COORDINATE LOCATIONS OF ANY MISCELLANEOUS EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS (I.E.,COPIERS, FAX MACHINES, PRINTERS, KITCHEN APPLIANCES, LAUNDRY APPLIANCES, PROJECTION SCREENS, SHOP TOOLS,MACHINE, ELEVATORS, ETC.) WITH APPROVED SHOP DRAWINGS, OWNER-PROVIDED CUT SHEETS, MANUFACTURER'SINSTRUCTIONS, AND EQUIPMENT NAMEPLATE INFORMATION, PRIOR TO ROUGH IN, AND PROVIDE NECESSARY ELECTRICALREQUIRED.2. VERIFY AND COORDINATE LOCATIONS AND EXACT ELECTRICAL REQUIREMENTS FOR MECHANICAL, PLUMBING AND FIREPROTECTION EQUIPMENT PRIOR TO SUBMITTAL OF SHOP DRAWINGS OF ELECTRICAL EQUIPMENT. PROVIDE NECESSARYRACEWAYS, CONDUCTORS, BOXES, EQUIPMENT, ACCESSORIES, ASSOCIATED DISCONNECT SWITCHES, CIRCUIT BREAKERS,CONTROL TRANSFORMERS, FIRE ALARM SHUTDOWN, ETC. REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM.COORDINATE WITH APPROPRIATE TRADE'S APPROVED SHOP DRAWINGS, MANUFACTURER'S INSTRUCTIONS, AND EQUIPMENTNAMEPLATE INFORMATION, PRIOR TO ROUGH IN, AND PROVIDE NECESSARY ELECTRICAL REQUIRED, UNLESS NOTEDOTHERWISE.3. THIS PROJECT REQUIRES COORDINATION DRAWINGS BY THE CONTRACTOR. PARTICIPATE IN THE COORDINATION DRAWINGPREPARATION PROCESS AND PROVIDE NECESSARY INFORMATION REQUIRED TO COORDINATE TRADE INFORMATION.4. WORK ON THE ELECTRICAL SYSTEM REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE COORDINATED WITH THE WORK OFOTHER DIVISIONS/TRADES PRIOR TO COMMENCEMENT OF WORK. AVOID INTERFERENCES WITH THE PROGRESS OF OTHERDIVISIONS/TRADES.5. WHERE WALLS ARE OF TILT-UP OR PRE-CAST CONSTRUCTION, PROVIDE COORDINATION FOR EXACT DIMENSIONS ANDOPENINGS REQUIRED FOR ELECTRICAL COMPONENTS INSTALLED WITHIN SUCH WALLS DURING THE SHOP DRAWING REVIEWPROCESS OF THE WALLS, PRIOR TO CONSTRUCTION OF THE WALLS.6. LOCATIONS OF VFD'S, DISCONNECTS, MOTOR STARTERS, ETC. FOR HVAC EQUIPMENT ARE DIAGRAMMATIC ON THE PLANDRAWINGS. EXACT LOCATIONS ARE TO BE COORDINATED WITH CONTRACTOR'S COORDINATION DRAWINGS PRIOR TO ROUGH-IN TO ENSURE PROPER NEC CLEARANCES AND APPROPRIATE MOUNTING SURFACES.7. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, CIVIL, LANDSCAPE, INTERIOR DESIGN, TECHNOLOGY,STRUCTURAL, AND VENDOR EQUIPMENT DRAWINGS FOR RELATED INFORMATION AND ADDITIONAL INSTALLATIONREQUIREMENTS TO BE PERFORMED AS PART OF THE WORK.8. WHERE A DISCREPANCY OR CONFLICT IS FOUND BETWEEN ONE DRAWING AND ANOTHER, OR BETWEEN A DRAWING ANDAPPLICABLE SPECIFICATIONS, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY IN WRITTEN FORM. IN GENERAL, THE MOSTSTRINGENT REQUIREMENT SHALL GOVERN UNLESS THE DISCREPANCY CONFLICTS WITH APPLICABLE CODES OR OWNER'SDESIGN STANDARDS, WHEREIN THE CODE OR OWNER'S DESIGN STANDARDS SHALL GOVERN.9. CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND/OR SITE AFFECTED BY THIS WORK PRIOR TO SUBMITTING BIDPRICE, SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT MAY AFFECT EXECUTION OF THEWORK. SUBMISSION OF A BID PRICE SHALL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE. LATERCLAIMS FOR LABOR, EQUIPMENT AND/OR MATERIALS REQUIRED DUE TO DIFFICULTIES ENCOUNTERED THAT COULD HAVEBEEN REASONABLY OBSERVED WILL NOT BE RECOGNIZED.10. COORDINATE PROJECT SCHEDULING AND PHASING REQUIREMENTS WITH ARCHITECT/ENGINEER AND OWNER PRIOR TOSUBMITTING BID PRICE. THIS PROJECT MAY REQUIRE PHASING SEQUENCES AND POTENTIAL PREMIUM TIME WORK AND ALLCOSTS FOR SUCH SHALL BE INCLUDED IN THE BID PRICE. PROVIDE ADEQUATE WORK FORCE AND EQUIPMENT, AND INCLUDEPREMIUM TIME AS MAY BE REQUIRED IN ORDER TO ADHERE TO THE PROJECT SCHEDULE. ADDITIONALLY, ENSURE THAT LONGLEAD ITEMS DO NOT IMPACT THE PROJECT'S SCHEDULE OR PHASING.11. ANY TEMPORARY INTERRUPTION OF POWER REQUIRED FOR THE SYSTEM TIE-IN OR SWITCHOVER FOR ANY PORTION OF THEELECTRICAL SYSTEM SHALL BE PRE-APPROVED IN WRITING BY THE OWNER AND SCHEDULED IN ADVANCE.12. COORDINATE EXACT REQUIREMENTS WITH THE LOCAL UTILITY COMPANIES AND PROVIDERS (ELECTRIC, TELEPHONE, CABLETV, ETC.) AND INCLUDE COSTS FOR PROVIDING TEMPORARY AND PERMANENT SERVICES REQUIRED FOR THIS PROJECT INTHE BID PRICE. BID PRICE SHALL INCLUDE, BUT NOT BE LIMITED TO, EXCAVATION, RACEWAYS, BACKFILL, EQUIPMENT,EQUIPMENT PADS, BACKBOARDS, METERS, GROUNDING, UTILITY ENGINEERING AND IMPACT FEES.13. CONDUCT WORK OPERATIONS AND DEBRIS REMOVAL IN A MANNER THAT ENSURES MINIMUM INTERFERENCE WITH NORMALBUSINESS OPERATIONS, TRAFFIC, PARKING, ETC. ONGOING IN ADJACENT OCCUPIED SPACES OR FACILITIES. PROVIDE ALLTHAT IS REQUIRED TO EFFECTIVELY PROTECT SURROUNDING OCCUPANTS, EQUIPMENT, FINISHES, FURNITURE, ETC. FROMDAMAGE OR EXCESSIVE NOISE THROUGHOUT THE DURATION OF THIS PROJECT. CONTRACTOR IS RESPONSIBLE FOR ANYLOSSES OR ANY DAMAGE RESULTING FROM THE FAILURE TO ADHERE TO THIS REQUIREMENT. RESTORE DAMAGED ELEMENTSTO ORIGINAL CONDITION TO THE SATISFACTION OF THE ARCHITECT/ENGINEER AND OWNER, AT NO ADDITIONAL COSTS.REPORT OF ANY SUCH OCCURRENCE TO THE ARCHITECT/ENGINEER AND OWNER IMMEDIATELY AND AWAIT WRITTENDIRECTION PRIOR TO PROCEEDING WITH REPAIRS.14. COORDINATE THE LOCATION OF LIGHT FIXTURES, DEVICES AND BOXES WITH WINDOWS, MIRRORS, MILLWORK, CABINETS,GLASS CURTAIN WALLS, AND GLASS WALLS PRIOR TO INSTALLATION OF CONDUITS OR BOXES. REVIEW CONTRACT DRAWINGSTO ASCERTAIN ANY CONFLICTS PRIOR TO BIDDING. OBTAIN CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO BID.CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL COMPENSATION FOR WORK REQUIRED TO RELOCATE OUTLET BOXESOR RACEWAYS FOR COORDINATION WITH OTHER TRADE'S WORK.CONDUCTORS1. CONDUCTOR SIZE SHALL BE ASSUMED TO BE #12 AWG MINIMUM OR OTHERWISE SIZED TO MEET NEC OR VOLTAGE DROPREQUIREMENTS.2. BRANCH CIRCUITS SHALL BE INCREASED IN SIZE AS REQUIRED TO COMPENSATE FOR VOLTAGE DROP FROM LENGTH OFCIRCUIT DUE TO FIELD ROUTING. FINAL INSTALLATION SHALL NOT EXCEED A MAXIMUM OF 3% VOLTAGE DROP FOR BRANCHCIRCUITS. REFER TO VOLTAGE DROP TABLE BELOW FOR CONDUCTOR SIZES FOR BRANCH CIRCUITS AS FOLLOWS:A. 120V, 20A CIRCUITS SHALL BE:i. #12 FROM 0-70 FTii. #10 FROM 71-115FTiii. #8 FROM 116-180FTB. 277V, 20A CIRCUITS SHALL BE:i. #12 FROM 0-140FTii. #10 FROM 141-220FTiii. #8 FROM 221-350FTANYTHING LONGER THAN THE ABOVE SHALL BE SUBMITTED TO THE ENGINEER WITH CALCULATIONS FOR APPROVAL.3. CONDUCTORS IN CABINETS MUST BE CAREFULLY FORMED AND HARNESSED SO THAT EACH CONDUCTOR DROPS OFFDIRECTLY OPPOSITE TO TERMINAL.4. CONDUCTORS ARE BASED ON AMPACITIES FOR 60 OR 75 DEGREE CELSIUS TEMPERATURE RATING UP TO 100A OR UP TO #1AWG AND 60 OR 75 DEGREE CELSIUS TEMPERATURE RATING ABOVE 100A OR ABOVE #1 AWG PER NEC 110.14(C)(1)(a)/(b) ANDTABLE 310.15(B)(16).RACEWAYS1. FLEXIBLE METAL CONDUIT AND LIQUID-TIGHT FLEXIBLE METAL CONDUIT (FMC & LFMC) SHALL NOT BE USED IN LENGTHSTHAT EXCEED 6'-0" UNLESS SPECIFICALLY NOTED OTHERWISE, OR UNLESS THE ARCHITECT/ENGINEER GRANTS WRITTENPERMISSION.2. FEEDER AND BRANCH CIRCUIT CONDUCTORS, INCLUDING LOW VOLTAGE SYSTEMS, SHALL BE INSTALLED IN A COMPLETERACEWAY SYSTEM (CONDUIT) UNLESS SPECIFICALLY NOTED OTHERWISE.3. THE USE OF ELECTRICAL NON-METALLIC TUBING (ENT) AND LIQUID-TIGHT FLEXIBLE NON-METALLIC CONDUIT (LFNC) AREPROHIBITED UNLESS SPECIFICALLY NOTED OTHERWISE, OR UNLESS THE ARCHITECT/ENGINEER OR OWNER GRANTSWRITTEN PERMISSION.4. CONNECTIONS TO TRANSFORMERS, AHU'S, AND PUMPS SHALL BE FLEXIBLE METAL CONDUIT (FMC) FOR INDOOR, DRYLOCATIONS AND LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC) FOR EXTERIOR OR INDOOR WET LOCATIONS.5. PVC CONDUIT SHALL NOT BE USED INSIDE BUILDING UNLESS OTHERWISE NOTED. UNDERGROUND OR IN-SLABINSTALLATIONS ARE ACCEPTABLE. WHERE AN UNDERGROUND RACEWAY ENTERS A BUILDING OR STRUCTURE, IT SHALL BESEALED AS PER NEC ARTICLES 230.8 AND 300.5(G). CONDUITS STUB-UPS WITHIN BUILDING SHALL BE MADE WITHGALVANIZED RIGID CONDUIT. NO NON-METALLIC RACEWAY ALLOWED WITHIN BUILDING (ASSEMBLY OCCUPANCY, NECARTICLE 518)6. CONDUIT TERMINATIONS AT TERMINAL BOARDS SHALL HAVE GROUNDING BUSHINGS AT CONDUIT ENDS.7. CONDUITS SHALL BE CONCEALED UNLESS IMPOSSIBLE DUE TO EXISTING CONDITIONS (I.E., EXPOSED CEILINGS, BUILDINGEXTERIOR WALL RUNS). CONCEAL CONDUITS ABOVE CEILINGS OR IN WALLS AND MILLWORK. WHERE EXISTING CONDITIONSDICTATE THAT CONDUITS CANNOT BE CONCEALED, NOTIFY ARCHITECT/ENGINEER PRIOR TO INSTALLING CONDUIT FORRESOLUTION TO ROUTING.8. SEAL PENETRATIONS AND OPENINGS MADE DURING EXECUTION OF WORK IN FIRE-RATED AND SMOKE-RATED WALLS.WALLS SHALL BE SEALED WITH UL-APPROVED PRODUCT WITH THE SAME OR GREATER RATING OF WALL PENETRATED.9. PROVIDE PENETRATIONS THROUGH FLOORS, WALLS, CEILINGS AND ROOFS WHERE REQUIRED. COORDINATE LOCATIONSAND SIZES WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS, FIELD CONDITIONS AND WORK OF OTHERDIVISIONS/TRADES. PENETRATIONS THROUGH FLOORS, WALLS, CEILINGS AND ROOFS SHALL BE WATERTIGHT.10. RACEWAYS THAT TURN UP THROUGH THE SLAB OR INTO ELECTRICAL EQUIPMENT FROM UNDERGROUND SHALL BE RIGIDGALVANIZED STEEL (RGS) WITH BITUMASTIC COATING FOR AT LEAST THE FINAL 18" LENGTH. THE USE OF NON-METALLICCONDUIT ABOVE GRADE IS PROHIBITED.11. PANEL SCHEDULES AND FLOOR PLANS MAY INDICATE DEDICATED HOMERUNS FOR EACH BRANCH CIRCUIT. BRANCHCIRCUITS MAY BE GROUPED IN A COMMON HOMERUNS WHERE THE HOMERUN DOES NOT EXCEED 3 PHASE CONDUCTORS,3 NEUTRAL CONDUCTORS, AND 1 EQUIPMENT GROUND. THE HOMERUN RACEWAY SIZE AND CONDUCTOR SIZE SHALL BEINCREASED AS NECESSARY TO COMPLY WITH THE NEC FOR 40% MAXIMUM FILL AND DERATING REQUIREMENTS.12. PROVIDE SEAL OFF FITTINGS, APPROVED FOR SUCH USE, WHERE RACEWAYS PENETRATE BETWEEN A DRY, CONDITIONEDENVIRONMENT AND THE EXTERIOR OR OTHER WET ENVIRONMENTS AND ADDITIONAL AREAS WHERE CONDUITS PASSFROM WARM TO COLD LOCATIONS SUCH AS WALK-IN COOLERS OR FREEZERS, BOILER ROOMS, ETC.13. PROVIDE POLYOLEFIN JET-LINE #232 (NYLON PULL STRING) IN EACH EMPTY CONDUIT WITH ENGRAVED METAL TAGINDICATING CONDUIT DESIGNATION.14. HOMERUNS SHALL BE IN 3/4" RACEWAY MINIMUM. 1/2" RACEWAY IS ACCEPTABLE FOR A SINGLE CIRCUIT FROM THEHOMERUN TO REMAINING DEVICES.15. WHERE AN UNDERGROUND RACEWAY ENTERS A BUILDING OR STRUCTURE, IT SHALL BE SEALED AS PER NEC ARTICLES230.8 AND 300.5(G).16. CONDUIT SHALL USE SET SCREW TYPE FITTINGS OR COMPRESSION FITTINGS.17. WHERE RACEWAYS ARE INSTALLED IN SLABS, THE MINIMUM SPACING, MAXIMUM RACEWAY SIZE, AND ANY OTHERSTRUCTURAL LIMITATIONS SHALL BE COORDINATED WITH THE STRUCTURAL DRAWINGS AND THE STRUCTURAL ENGINEERPRIOR TO INSTALLATION.IDENTIFICATION1. PROVIDE TYPED PANEL DIRECTORIES FOR ALL NEW PANELBOARDS, AND EXISTING PANELBOARDS AFFECTED BY THIS PROJECT.DIRECTORIES SHALL REFLECT PROJECT AS-BUILT CONDITIONS FOR BRANCH CIRCUITS. DIRECTORIES SHALL INCLUDE WHEREEACH PANEL IS FED FROM. ADDITIONALLY, EACH BRANCH CIRCUIT LOAD DESCRIPTION SHALL INCLUDE THE ROOM NUMBER(S)FOR EACH LOAD (I.E., RECEPTACLES-RMS 501,503). ROOM NUMBERS SHALL BE BASED ON ACTUAL ROOM SIGNAGE INSTALLED INFIELD. COORDINATE EXACT ROOM NUMBERS WITH ARCHITECT/ENGINEER AND OWNER PRIOR TO COMPLETION OF PANELDIRECTORIES.2. PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS ON EACH SWITCHBOARD, SWITCHGEAR, DISTRIBUTION PANEL,PANELBOARD, MOTOR CONTROL CENTER, SAFETY SWITCH, ENCLOSED CIRCUIT BREAKER, CABINET, STEP-DOWNTRANSFORMER, TRANSFER SWITCH, ETC., AND ANY OTHER MAJOR COMPONENT OF THE ELECTRICAL SYSTEM.3. PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS FOR EACH DISTRIBUTION BREAKER OR BRANCH CIRCUIT BREAKER INSWITCHGEAR, SWITCHBOARDS, MOTOR CONTROL CENTERS AND OTHER DISTRIBUTION EQUIPMENT. NAME TAG SHALL INCLUDELOAD DESCRIPTION AND ROOM NUMBER FOR EACH LOAD.4. ARC FLASH DANGER/WARNING LABELS SHALL BE APPLIED TO SWITCHBOARDS, PANELBOARDS, EQUIPMENT CONTROLLERS ANDOTHER DISTRIBUTION EQUIPMENT PER NEC.5. PROVIDE NEATLY, HANDWRITTEN IDENTIFICATION ON THE EXTERIOR COVER OF JUNCTION BOXES, PULLBOXES AND WIREWAYS,IDENTIFYING THE PANEL(S)/ CIRCUIT NUMBER(S) CONTAINED WITHIN.6. PROVIDE A PERMANENT LABEL ON PANELBOARDS, SWITCHBOARDS, SWITCHGEAR, MOTOR CONTROL CENTERS ANDDISTRIBUTION PANELS STATING "DO NOT WORK ON EQUIPMENT WHILE ENERGIZED. LOCK- OUT TAG-OUT REQUIRED".7. PROVIDE REQUIRED IDENTIFICATION PER ANSI STANDARDS, NEC REQUIREMENTS, AND OWNER'S PUBLISHED DESIGNSTANDARDS WHERE APPLICABLE.8. PROVIDE ENGRAVED PHENOLIC LABEL ON NEW SERVICE EQUIPMENT TO INDICATE THE MAXIMUM AVAILABLE FAULT CURRENTAND THE DATE THE FAULT CURRENT CALCULATION WAS PERFORMED. PROVIDE LABEL ON EXISTING SERVICE EQUIPMENT WHENMODIFICATIONS OCCUR THAT AFFECT THE MAXIMUM AVAILABLE FAULT CURRENT AT THE SERVICE.APPLICABLE CODESAPPLICABLE CODES:WORK UNDER THIS DIVISION SHALL BE IN STRICT COMPLIANCE AND IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THEFOLLOWING CODES AND STANDARDS INCLUDING THE REGULATIONS OF GOVERNING LOCAL, STATE, COUNTY AND OTHERAPPLICABLE CODES. REFER TO SPECIFICATIONS FOR ADDITIONAL CODE REQUIREMENTS:BUILDING CODES:• FLORIDA BUILDING CODE, 8TH EDITION (2023)• FLORIDA ENERGY CONSERVATION CODE, 8TH EDITION (2023)• FLORIDA FIRE PREVENTION CODE, 8TH EDITION (2023)ADDITIONAL CODES, STANDARDS, AND REQUIREMENTS1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI).2. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE).3. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA).4. REQUIREMENTS OF LOCAL POWER COMPANY.5. THE AMERICANS WITH DISABILITIES ACT (ADA).6. OWNER'S PUBLISHED DESIGN STANDARDS.ALL MATERIALS SHALL BE NEW AND FREE OF DEFECTS, AND SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LAB, ASDEFINED BY OSHA. WHERE NO LABELING OR LISTING SERVICE IS AVAILABLE FOR CERTAIN TYPES OF EQUIPMENT, TEST DATASHALL BE SUBMITTED TO VALIDATE THAT EQUIPMENT MEETS OF EXCEEDS AVAILABLE STANDARDS.NATIONAL FIRE PROTECTION (NFPA) STANDARDS:• NFPA 70, 2020 EDITION, NATIONAL ELECTRICAL CODE®.• NFPA 101, 2021 EDITION, LIFE SAFETY CODE®.• NFPA 110, 2019 EDITION, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS.4. PROVIDE A GROUND BUS BAR IN EACH ELECTRICAL ROOM AND TELECOMMUNICATIONS / IDF/ MDF ROOM FOR NEWCONSTRUCTION AND NEW ROOMS IN EXISTING CONSTRUCTION, AND IN EXISTING CONSTRUCTION WHERE THERE IS NONEINSTALLED WITHIN AN EXISTING ROOM.ELECTRICAL EQUIPMENT1. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BEINSTALLED. COMPONENTS OF THE ELECTRICAL SYSTEM LOCATED OUTDOORS OR INDOORS WHERE EXPOSED TO SIGNIFICANTMOISTURE SHALL BE WEATHERPROOF, NEMA 3R, AS A MINIMUM, WHETHER INDICATED ON THE CONTRACT DRAWINGS OR NOT.2. TERMINATION PROVISIONS FOR ELECTRICAL EQUIPMENT (PANELBOARDS, SWITCHBOARD, TRANSFORMERS, DISCONNECTSWITCHES, MOTOR CONTROLLERS, AUTOMATIC TRANSFER SWITCHES, ENCLOSED CIRCUIT BREAKERS, BUSWAYS, ETC.) SHALLBE LISTED AND IDENTIFIED FOR USE WITH MINIMUM 75 DEGREES FAHRENHEIT CONDUCTORS IN ACCORDANCE WITH NEC.3. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC.4. THE ELECTRICAL DEDICATED EQUIPMENT SPACE EXTENDING FROM FLOOR TO 6' ABOVE ELECTRICAL EQUIPMENT OR TO THESTRUCTURAL CEILING, WHICHEVER DISTANCE IS LOWER, WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARDMUST BE CLEAR OF PIPING, DUCTS, ARCHITECTURAL APPURTENANCES AND OTHER EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION IN ACCORDANCE WITH NEC. IF SPACE IS AVAILABLE, FOREIGN SYSTEMS MAY BE PRESENT ABOVE THEDEDICATED EQUIPMENT SPACE PROVIDED PROTECTION IS INSTALLED TO PREVENT DAMAGE TO ELECTRICAL EQUIPMENTBELOW FROM CONDENSATION, LEAKS, OR BREAKS IN THESE SYSTEMS.5. PROVIDE A REINFORCED CONCRETE PAD, SIZED 4" LARGER IN ALL DIRECTIONS THAN THE FOOTPRINT OF THE EQUIPMENT ANDFOR FREESTANDING, FLOOR-MOUNTED ELECTRICAL EQUIPMENT. PROVIDE VIBRATION ISOLATORS AND/OR ANCHORS PERMANUFACTURER'S INSTRUCTIONS.6. PROVIDE HACR RATED CIRCUIT BREAKER FOR HVAC EQUIPMENT.5. CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE NOTED, THHN/THWN-2 90 DEGREES CELSIUS; SOLID FOR #10 AWG ANDSMALLER; STRANDED FOR #8 AWG AND LARGER.6. CONDUCTORS USED IN WET LOCATIONS, INCLUDING BUT NOT LIMITED TO UNDERGROUND CONDUITS/DUCTBANKS ANDEXTERIOR CONDUITS SHALL COMPLY WITH NEC 310.10 AND BE LISTED FOR USE IN WET LOCATIONS.7. POWER CIRCUITS HAVE BEEN DESIGNED TO MEET 2% OR LESS VOLTAGE DROP FOR FEEDERS, AND 3% OR LESS VOLTAGEDROP FOR BRANCH CIRCUITS.8. BRANCH CIRCUIT NEUTRALS SHALL BE DEDICATED UNLESS OTHERWISE NOTED. CIRCUITS SHARING A COMMON NEUTRALMUST HAVE COMMON TRIP CIRCUIT BREAKERS TO ALLOW ALL TO BE TURNED OFF SIMULTANEOUSLY, AS PER NEC 210.4(B).ELECTRICAL DEVICES OUTLET BOXES, JUNCTION BOXES1. COMPONENTS OF THE ELECTRICAL SYSTEM (INCLUDE RACEWAYS, ELECTRICAL EQUIPMENT, OUTLET BOXES, JUNCTION BOXES,ETC.) LOCATED IN A HAZARDOUS (CLASSIFIED) LOCATION SHALL BE APPROVED FOR USE IN SAID LOCATION, AS DEFINED BY THENEC, WHETHER INDICATED ON THE CONTRACT DOCUMENTS OR NOT.2. DEVICES SHALL BE MOUNTED VERTICALLY, UNLESS NOTED OTHERWISE.3. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE-RESISTIVE ASSEMBLIES, THEY SHALL BE INSTALLED WITHOUTAFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET:A. ELECTRICAL BOXES SHALL BE METALLIC.B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE.C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES.D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OROTHER APPROVED MATERIAL).E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BEMAINTAINED.F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET.G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUMHORIZONTAL DISTANCE OF 24 INCHES.H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS.I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THEOUTLET BOX AND THE EDGES OF THE OPENING.SHEETE001E002E101E501E601ED101ELECTRICAL DRAWING INDEXDESCRIPTIONELECTRICAL SYMBOLS, LEGEND, AND ABBREVIATIONSELECTRICAL GENERAL NOTES AND INDEXELECTRICAL PLANELECTRICAL DETAILSELECTRICAL PANEL AND EQUIPMENT SCHEDULESELECTRICAL DEMO PLANWHERE THERE IS A DISCREPANCY BETWEEN ABOVE GENERAL NOTES AND SPECIFICATIONS, WHERE APPLICABLE, SPECIFICATIONS SHALL BE FOLLOWEDSEALENGINEER OF RECORDMONCEF M. HADIJIDESIGNED BYJOEY HOLTDRAWN BYJOEY HOLTISSUE DATE12/01/2025AE PROJECT NUMBER525260SHEET TITLEELECTRICAL GENERALNOTES AND INDEXDRAWING NO.E002TOILET700DCH-1MECH EQUIP AREA713TOILET700CM7-211ELECTRICAL PLAN1/4" = 1'-0"EX OAC7CUST700APUMP & MECH. ROOM712PCH7-1PCH7-2P71-14,16,1812P71-38,40,4212T7M7M700ELEC711P71LV71P701C.E.R.710CSTOR710DGENERAL NOTESA. LAYOUT IS BASED UPON NON-INVASIVE FIELD INVESTIGATION AND LIMITED EXISTING AS-BUILTS. CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIESBETWEEN THIS LAYOUT AND FIELD CONDITIONS.# KEYNOTES1. SEE MECHANICAL EQUIPMENT SCHEDULE ON SHEET E601 FOR ALL CONDUCTOR, CONDUIT,AND DISCONNECT SIZES.2. REPLACEMENT OF PUMPS AND ASSOCIATED ELECTRICAL EQUIPMENT IS BID ALTERNATE 1.SEALENGINEER OF RECORDMONCEF M. HADIJIDESIGNED BYJOEY HOLTDRAWN BYJOEY HOLTISSUE DATE12/01/2025AE PROJECT NUMBER525260SHEET TITLEELECTRICAL PLANDRAWING NO.E101METAL SUPPORTSTRUCTURE NEC250-52(A)(2)MAIN GROUNDING BUS(GROUND BAR)GROUNDINGELECTRODECONDUCTORNEC 250-66FINISHED GRADEGROUND ROD NEC250-52(A)(5)INCOMINGSERVICESERVICE EQUIPMENTMAINBUSSINGABCNSUPPLY SIDE BONDING JUMPER.NEC 250-102NEUTRAL BUSMAIN BONDING JUMPER. NEC 250-1021EQUIPMENT GROUND BUSGROUNDING ELECTRODECONDUCTOR. NEC 250-66FINISHED FLOORNOTES:1 BONDING JUMPER. NEC 250.102PROVIDE COMPLETE GROUNDING ELECTRODE SYSTEM AND GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH NECARTICLE 250 AND NEC ARTICLE 250.50.GROUNDING SYSTEM DETAILNo Scale2FINISHED CEILINGWALL MOUNTED LIGHT FIXTURESAS NOTED ON PLANSPANELBOARDC ABOVE COUNTERTELE./DATA OUTLET78" MAX.TO TOP OFHIGHESTOPERABLEDEVICE6" AFC36"AFFCENTEREDOVER DOOR(CEILING OR WALL)CL6" MINCS CB SH T SE S D NCS NURSE CALL DEVICEABOVE COUNTERRECEPTACLECL3" (TYP)48" TOTOP OFDEVICE42" AFF W/36"H COUNTER,39" AFF W/30"H COUNTER,48" AFF WITHOUT COUNTEROR AS NOTED ON PLANSFINISHED FLOORNOTES:1. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL ELEVATIONS, OTHER DISCIPLINES, AND ELECTRICAL PLANS TAKE PRECEDENCE OVER MOUNTING HEIGHTS INDICATED IN THISDETAIL. IF THERE IS A DISCREPANCY IN THE MOUNTING HEIGHTS BETWEEN ARCHITECTURAL ELEVATIONS, OTHER DISCIPLINES, AND THE ELECTRICAL PLANS, THE DIMENSIONS ON THEARCHITECTURAL ELEVATIONS AND OTHER DISCIPLINES SHALL DICTATE MOUNTING HEIGHT. IF NO MOUNTING HEIGHTS ARE INDICATED, INSTALL DEVICES PER THIS DETAIL.2. NOT ALL DEVICES SHOWN APPLY TO PROJECT.WALL-MOUNTED - CENTERED BETWEEN FLOORS & CEILING FOR CEILINGS 10' & LESS, 6"ABOVE DOOR FRAME TO BOTTOM OF EXIT LIGHT FOR CEILINGS GREATER THAN 10'(COORDINATE WITH ARCHITECTURAL ELEVATIONS)WALL-MOUNTED FIRE ALARM STROBE,SPEAKER/STROBE, HORN/STROBE, ORSPEAKERBOTTOM OF STROBELENSMULTI-SERVICE BOX OR SINGLE BOXDEVICES FOR TELEVISION OR MONITOR TVFIRE ALARM PULL FSTATIONCL80"48" TOTOP OFDEVICEWALL PHONEWLIGHT SWITCH SVOICE/DATAOUTLETCL18"3" (TYP)DUPLEX OR QUAD RECEPTACLE,SPECIAL RECEPTACLEWALL FURNITURE FEED (POWER ORDATA)MOUNTING HEIGHT SHALL BEVERIFIED WITH ARCHITECTURALELEVATIONS PRIOR TO ROUGH-INCL18"MULTI-SERVICE BOX FOR AV EQUIP.CABINETTVAVMOUNTING HEIGHTSNo Scale1SEALAHU-X480V, 3ØEMERGENCY BRANCHFED FROM PANEL "XXXX-##"AHU-X480V, 3ØEMERGENCY BRANCHFED FROM PANEL "XXXX-##"TYPICAL EQUIPMENTEQUIPMENT NAMEPLATENo ScaleLETTERING COLOR PER SPECIFICATIONS U.O.N.ON THIS DETAIL1/16" THICK WHITE PLASTIC WITH FACE COLOR PERSPECIFICATIONS U.O.N. ON THIS DETAILFASTEN WITH BRASS SCREWS WHEN LOCATED INNON-CONDITIONED OR EXTERIOR SPACESIDENTIFY BRANCH OF THE ELECTRICAL SYSTEM(E.G. NORMAL, CRITICAL, LIFE SAFETY, EQUIPMENT, EMERGENCY,LEGALLY-REQUIRED STANDBY, OPTIONAL STANDBY)ADHESIVE BACKING WHEN INSTALLEDIN CONDITIONED INTERIOR SPACES (SILICONESEALANT AROUND OUTSIDE EDGE TO PREVENTMOISTURE DAMAGE TO ADHESIVE BACKING)EQUIPMENT NAME (1/2" HIGH LETTERING)1/4" HIGH LETTERING FORREMAINING TEXTEQUIPMENT VOLTAGEBRANCH OF ELECTRICAL SYSTEMEQUIPMENT SOURCE (PANEL & CIRCUIT)BRANCHLIFE SAFETYEQUIPMENTCRITICALNORMALUPSPLATE AND LETTERING COLORYELLOW WITH BLACK LETTERINGGREEN WITH WHITE LETTERINGORANGE WITH WHITE LETTERINGBLACK WITH WHITE LETTERING.BLUE WITH WHITE LETTERING3ENGINEER OF RECORDMONCEF M. HADIJIDESIGNED BYJOEY HOLTDRAWN BYJOEY HOLTISSUE DATE12/01/2025AE PROJECT NUMBER525260SHEET TITLEELECTRICAL DETAILSDRAWING NO.E501
- Commodity Codes
-
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Orange County Corrections Dep...
Project ID: Y25-790-RC Title: Orange County Corrections Department Female Detention Center Two Cell
Orange County
Bid Due: 7/14/2026
Drainage Repair and/or New Pu...
Project ID: 25/26-094 Title: Drainage Repair and/or New Public Works Construction Addenda: 0
Clay County
Bid Due: 7/09/2026