Addendum No. 1 Bid #26-06 14th Ave Stormwater Pump Station
Project Information
- Bid Title
- Addendum No. 1 Bid #26-06 14th Ave Stormwater Pump Station
- Issuing Agency
- Borough of Seaside Park
- Location
- New Jersey
- Published Date
- Jun 18, 2026
- Closing Date
- Jun 30, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Description Opening Date Closing Date
Addendum No. 1
Bid #26-06 14th Ave Stormwater Pump Station
June 18, 2026
:
June 30, 2026
10:30
AM
- Attachment Preview
-
BOROUGH OF SEASIDE PARKOCEAN COUNTY, NEW JERSEYOUR FILE: 1528-U-090BID #26-06 14TH AVENUE STORMWATER PUMP STATIONADDENDUM #1JUNE 18, 2026The following additions to the Contract Documents will be written into any Contract for the“14TH AVENUE STORMWATER PUMP STATION” project and must be taken into accountin rendering a Proposal for the work.The following items shall be revised as follows at this time:1. The access hatches for the pump station and valve vault have been revised to requireHalliday Products Series F1R access hatches or approved equal. Plan Sheets 7 and 8 andSpecification Section 333213.13 have been revised accordingly. The revised plan sheetsand specification section are attached to this Addendum.2. Four (4) explosion-proof terminal boxes, Larson Electronics Model EPJ-6-TB.8, orapproved equal, shall be provided as intermediate transition points between wet wellequipment conductors and the pump control panel. Plan Sheets E2.1 and E3.1 andSpecification Section 333213.13 have been revised accordingly. The revised plan sheetsand specification section are attached to this Addendum.3. The stainless steel ladder extension for the valve vault has been removed from theContract Documents. Plan Sheet 8 and Specification Section 333213.13 have beenrevised accordingly. The revised plan sheet and specification section are attached to thisAddendum.4. The specified air-cushioned check valve for the pump station discharge piping has beenreplaced with a check valve with outside lever and weight. Specification Section333213.13 has been revised accordingly. The revised specification section is attached tothis Addendum.5. The Bid Opening date and time have been revised from June 24, 2026 at 10:30 AMto June 30, 2026 at 10:30 AM. All bids shall be submitted in accordance with therevised bid opening date and time.All specifications and bids shall be revised accordingly.Please complete the “Acknowledgement of Receipt of Addenda” (Page P-3), attachedhereto, for receipt of this Addendum letter and include with bid documents submission.The Acknowledgement of receipt of addenda page is a mandatory required document andfailure to submit shall be deemed a fatal defect.Alan B. Dittenhofer, PE, PP, CMENJ PE License #376721528U090 Addendum #1.docxSEALACKNOWLEDGEMENT OF RECEIPT OF CHANGES TO BID DOCUMENTS FORMBorough Of Seaside Park14th Avenue Stormwater Pump Station(Name of Project)Our File: 1528-U-090(Project or Bid Number)Pursuant to N.J.S.A. 40A:11-23.1a., the undersigned bidder hereby acknowledges receipt of the followingnotices, revisions, or addenda to the bid advertisement, specifications or bid documents. By indicatingdate of receipt, bidder acknowledges the submitted bid takes into account the provisions of the notice,revision or addendum. Note that the local unit’s record of notice to bidders shall take precedence and thatfailure to include provisions of changes in a bid proposal may be subject for rejection of the bid.Local Unit Reference NumberOr Title of Addendum/RevisionNotice, Revision orAddenda No.Addendum #1Title or DescriptionHow Received(mail, fax,pick-up, etc.)Date Bidder’sReceived InitialsAcknowledged by bidder:Name of Bidder:By Authorized Representative:Signature:Printed Name and Title:Date:P-3SECTION 33 32 13.13SPECIFICATIONS FOR PACKAGED SEWAGE LIFT STATIONS, WET WELL TYPEGENERAL1.1 SECTION INCLUDESA.Sewage/Storm Water/ Non-Potable Water1.Pump Stationsa.Extent of packaged pump station work required by this Section is indicatedon Drawings and Schedules and by requirements of this Section.1) Under this Section the Contractor shall furnish and install one (1) pre-packaged, pre–assembled pump station complete with submersiblepumps, precast concrete pump chamber with integral valve vaultstructure, slide rail pump removal system, discharge piping withrequired supports and fittings, discharge check and plug valves, accesshatches, valve vault access ladder, liquid level controls, duplex pumpcontrol panel, internal wiring and other required associate options andappurtenances)as supplied by Mid Atlantic Pump & EquipmentCo.(856-768-3880).2) The pre-packaged pump station shall be manufactured and pre-assembled off site to ensure product quality and consistency. The pre-package pump station manufacturer or their distributors shall providesole-source responsibility to the owner through the warranty period.1.2 RELATED SECTIONSA.03 00 00 ConcreteB.33 00 00 Utilities1.3 REFERENCESWhere applicable, the latest editions of the following standards shall form a part of this specification to theextent referenced. The publications are referenced to in the text of this guide specification by the basicdesignation only.AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS(AASHTO)ACI INTERNATIONAL (ACI)ACI 211.1ACI 211.2ACI 304RStandard Practice for Selecting Proportions forNormal, Heavyweight, and Mass ConcreteStandard Practice for Selecting Proportions forStructural Lightweight ConcreteGuide for Measuring, Mixing, Transporting, and333213.13-1ACI 305RACI 306RACI 309RACI 318ACI 350ACI 517.2RPlacing ConcreteHot Weather ConcretingCold Weather ConcretingConsolidation of ConcreteBuilding Code Requirements forStructural ConcreteCode Requirements for Environmental EngineeringConcrete Structures and CommentaryAccelerated Curing of Concrete at AtmosphericPressureAMERICAN NATIONAL STANDARDS INSTITUTE (ASTM)ASTM A 36Specification for Carbon Structural SteelASTM A 82Specification for Steel Wire, Plain, for ConcreteReinforcementASTM A 615Specification for Deformed and Plain Billet-SteelBars for Concrete ReinforcementASTM C 31Standard Practice for Making and Curing ConcreteTest Specimens in the FieldASTM C 33Specification for Concrete AggregatesASTM C 39Test Method for Compressive Strength of CylindricalConcrete SpecimensASTM C 40Test Method for Organic Impurities in FineAggregates for ConcreteASTM C 70Standard Test Method for Surface Moisture in FineAggregateASTM C 117Standard Test Method for Materials Finer than 75-µm (No. 200) Sieve in Mineral Aggregates byWashingASTM C 123Standard Test Method for Lightweight Particles inAggregateASTM C 136Test Method for Sieve Analysis of Fine and CoarseAggregatesASTM C 138Test Method for Density (Unit Weight), Yield, and AirContent (Gravimetric) of ConcreteASTM C 150Specifications for Portland Cement333213.13-2ASTM C 172ASTM C 192ASTM C 231ASTM C 260ASTM C 494ASTM C 566ASTM C 595ASTM C 617ASTM C 618ASTM C 805ASTM C 857ASTM C 858ASTM C 890ASTM C 891ASTM C 913ASTM C 920ASTM C 990ASTM C 1037Standard Practice for Sampling Freshly MixedConcretePractice for Making and Curing Concrete TestSpecimens in the LaboratoryTest Method for Air Content of Freshly MixedConcrete by the Pressure MethodSpecification for Air-Entraining Admixtures forConcreteStandard Specification for Chemical Admixtures forConcreteTest Method for Total Evaporable Moisture contentof Aggregate by DryingSpecification for Blended Hydraulic CementsStandard Practice for Capping Cylindrical ConcreteSpecimensSpecification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use as a Mineral Admixture inConcreteTest Method for Rebound Number of HardenedConcretePractice for Minimum Structural Design Loading forUnderground Precast Concrete Utility StructuresSpecification for Underground Precast ConcreteUtility StructuresPractice for Minimum Structural Design Loading forMonolithic or Sectional Precast Concrete Water andWastewater StructuresPractice for Installation of Underground PrecastConcrete Utility StructuresSpecification for Precast Concrete Water andWastewater StructuresSpecification for Elastomeric Joint SealantsSpecification for Joints for Concrete Pipe,Manholes, and Precast Box Sections UsingPreformed Flexible Joint SealantsPractice for Inspection of Underground PrecastConcrete Utility Structures333213.13-3
- Commodity Codes
-
- NAICS 237110Water and Sewer Line and Related Structures Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Specifications for West Branc...
Bid # 26-16 : Specifications for West Branch Sluice Repair and Rehabilitation Project,
County of Salem
Bid Due: 7/24/2026
Sea Bright to Manasquan, New ...
Follow Sea Bright to Manasquan, New Jersey FY 26 Renourishment Active Contract Opportunity
DEPT OF DEFENSE
Bid Due: 8/08/2026