Thermal Arc Sound Attenuation Booth
Project Information
- Bid Title
- Thermal Arc Sound Attenuation Booth
- Issuing Agency
- DEPT OF DEFENSE
- Location
- Oklahoma
- Published Date
- Oct 2, 2026
- Closing Date
- Oct 13, 2026
- Government Level
- Federal
- Status
- Closed
- Ref. #
- W911S227U0010
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Set Aside
- Total Small Business Set-Aside (FAR 19.5)
- Project Description
-
FollowThermal Arc Sound Attenuation BoothActiveContract OpportunityNotice IDW911S227U0010Related NoticeDepartment/Ind. AgencyDEPT OF DEFENSESub-tierDEPT OF THE ARMYMajor CommandAMCSub CommandACCSub Command 2MISSION INSTALLATION CONTRACTING COMMANDSub Command 3419TH CSBOfficeW6QM MICC-FT DRUMGeneral InformationLooking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Oct 02, 2026 02:47 pm CDT
- Original Date Offers Due: Oct 13, 2026 12:00 pm CDT
- Inactive Policy: Manual
- Original Inactive Date: Oct 02, 2027
-
Initiative:
- None
Classification- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 5410 - PREFABRICATED AND PORTABLE BUILDINGS
-
NAICS Code:
- 332322 - Sheet Metal Work Manufacturing
-
Place of Performance:
McAlester Army Ammunition Plant; 1 C Tree Rd Building 6; McAlester, OK 74501 74501
DescriptionThermal Arc Booth Salient Characteristics MCAAP Engineering will verify and validate the proposal from the vendor prior to award.Scope: Thermal Arc Sound Attenuation Booth. Includes all necessary parts and hardware for a completely erected (in 2 halves) Thermal Arc Booth.Item/Model #: QT100118128TA or similar. 1 EAProduct Description:77.5-inch x 102.5-inch x 116-inch Booth.Includes all necessary parts and hardware for a completely erected (in 2 halves) Thermal Arc Booth.18ga galvanized flat panel construction with single slope style roof. Rockwool insulation enclosed in between the 3-inch-deep exterior wall panel and the galvanized, perforated interior liner. Unit is to be assembled and shipped with doors loose. Door hardware and switches included.All onsite installation, mounting, etc. are by others. All auxiliary components (exhaust fan, lights, switches, etc.) are supplied and installed by others.Model: Qualitech thermal arc sound attenuation booth model QT77102116TA or similar. 1 EA.Product Description:100-inch x 118.5-inch x 128-inch Booth.Includes all necessary parts and hardware for a completely erected (in 2 halves) Thermal Arc Booth.18ga galvanized flat panel construction with single slope style roof. Rockwool insulation enclosed in between the 3-inch-deep exterior wall panel and the galvanized, perforated interior liner. Unit is to be assembled and shipped with doors loose. All onsite installation, mounting, etc. are by others. All auxiliary components (exhaust fan, lights, switches, etc.) are supplied and installed by others.Thermal Arc Booth Dimensional specs:102.5-inch overall outer dimension entrance to exit face.86.5-inch overall outer dimension of booth depth.36.5-inch outer dimension of front booth section depth.20-inch outer dimension of back booth section depth including the welding arm offset.44-inch outer dimension wide by 9-inch outer dimension deep welding arm offset centered on the back booth section with a 114-inch tall and 26-inches wide cut out.30-inch door gap between the front and back booth sections.10-inch gap on the top between the front and back booth sections for monorail fed items.120-inch minimum interior height.3-inch-deep exterior wall panels.18-inch x 18-inch hole for duct transition piece located on the front booth section above the internal plenum.Features: Internally mounted entrance door that swings towards the front.Externally mounted exit door that swings towards the front.Door hardware and switches including cylinders and controls.Internal plenum in the front booth section for ventilation.Welding arms offset and cut out.18ga galvanized flat panel construction with single slope style roof.Rockwool insulation.Galvanized perforated interior liner.Mounting plates for floor anchoring.Anchoring hardware. Internal bracing.MCAAP to provide: Building air. Installation. Auxiliary components.DETAILED DESCRIPTION REQUIRED PRIOR TO AWARD: The MCAAP Engineering Support Division will validate and verify/approve the contractor listed equipment concept before award is granted. In order to meet this review requirement, the offeror shall submit with their proposal a detailed technical description of the thermal arc booth. The offeror���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������s description submittal shall account for each one of the required product features located in this qualifying statement. Conceptual drawings that are not detail ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������as built��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� drawings are required for submittal with the detailed description.Approval drawing(s) is/are requested. 3D models requested can be in native SolidWorks format, IGES, and/or STEP within two weeks after award.Attachments/LinksContact InformationHistoryContracting Office Address- MICC FORT DRUM 4205 PO VALLEY RD
- FORT DRUM , NY 13602-5220
- USA
Primary Point of Contact- Eric Markland
- eric.w.markland.civ@army.mil
- Phone Number 15206872958
Secondary Point of Contact
- Oct 02, 2026 02:47 pm CDTCombined Synopsis/Solicitation (Original)
- Commodity Codes
-
- FSC 54Prefabricated Structures and Scaffolding
- NAICS 332322Sheet Metal Work Manufacturing
- Related bids
-
Oct 5, 2026 [Combined Synopsis/Solicitation (Updated)] Thermal Arc Sound Attenuation Booth
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Solicitation 2027-001-007- RF...
Procurement #164957 Title Solicitation 2027-001-007- RFB Concrete Above Ground Storm Shelters Status Active
Cherokee Nation
Bid Due: 10/23/2026