DPS Post 13 Upper Parking Lot Replacement
Project Information
- Bid Title
- DPS Post 13 Upper Parking Lot Replacement
- Issuing Agency
- State Government of Iowa
- Location
- Iowa
- Published Date
- May 7, 2026
- Closing Date
- Jun 4, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- RFB951100-01
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Bid InformationBid Number
RFB951100-01
Solicitation
DPS Post 13 Upper Parking Lot Replacement
Solicitation Type
Request for Bids
CountyDescriptionDescription
The Iowa Department of Administrative Services will be receiving bids for the replacement of the upper parking lot at the Department of Public Safety Post 13, 1300 S Grand Ave, Suite 201, Mount Pleasant, Iowa 52641.
The Iowa Department of Administrative Services anticipates construction to begin late this summer or early fall with completion no later than 10/16/2026.
An optional Pre-Bid meeting will be held on Tuesday, May 12, 2026 at 10:00 am at Department of Public Safety Post 13, 1300 S Grand Ave, Suite 201, Mount Pleasant, Iowa 52641.. This meeting is not mandatory but is highly recommended.
Agency InformationNumber
005
Name
Administrative Services, Dept
Address 1
1305 E Walnut St
Address 2
City/State/Zip
Des Moines, IA 50319
Contact InformationContact Name
Construction Procurement
Contact Title
Katelyn Howells
Contact Email
Contact Phone Number
(515) 721-7856
Contact Phone Extension
Contact Other Number
Contact Fax NumberValid DatesFrom
5/7/2026 12:00:00 PM
Until
6/4/2026 2:00:00 PM
Documents/Attachments - Attachment Preview
-
IOWA DEPARTMENT OF ADMINISTRATIVE SERVICESCONSTRUCTION PLANS FORDPS POST 13 - UPPER PARKING LOT REPLACEMENTDAS PROJECT #9511.00GOVERNING SPECIFICATIONSTHE 2026 EDITION OF THE "IOWA STATEWIDE URBANSPECIFICATIONS FOR PUBLIC IMPROVEMENTS".MUTCD 2009 AS ADOPTED BY IOWA DEPARTMENT OFTRANSPORTATION.ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS ANDORDINANCES WILL BE COMPLIED WITHIN THE CONSTRUCTIONOF THIS PROJECT.NOTE: EXISTING UTILITY INFORMATION SHOWN ON THISPLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THECONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS PRIORTO COMMENCING CONSTRUCTION AS REQUIRED BY STATELAW. NOTIFY IOWA ONE CALL 1-800-292-8989 OR 811THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN ISUTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THISUTILITY LEVEL WAS DETERMINED ACCORDING TO THEGUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARDGUIDELINES FOR THE COLLECTION AND DEPICTION OFEXISTING SUBSURFACE UTILITY DATA."PROJECT LOCATION1300 S. GRAND AVE.MT PLEASANT, IOWA 52641MOUNT PLEASANT, IAMAY, 2026INDEX OF SHEETSSHEET NUMBERSHEET TITLEREVISION ISSUE DATEA.01TITLE SHEET004/027/2026A.02LEGEND004/027/2026B.01TYPICAL SECTIONS004/027/2026B.02TYPICAL DETAILS004/027/2026C.01ESTIMATED PROJECT QUANTITIES004/027/2026C.02ESTIMATE REFERENCE NOTES004/027/2026RD.01PARKING LOT LAYOUT004/027/2026D.02PLAN & PROFILE - ENTRANCE DRIVE004/027/2026F.01REMOVALS004/027/2026G.01CONTROL POINTS & ALIGNMENT DATA004/027/2026J.01STAGING004/027/2026L.01JOINTING LAYOUT004/027/2026R.01GRADING & EROSION CONTROL004/027/2026S.01STOOP REPLACEMENT AND STOREFRONT MODIFICATIONS004/027/2026PROFESS IONALCHRISTOPHERL. MARTINP25714I OWAI HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WASPREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISIONAND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEERUNDER THE LAWS OF THE STATE OF IOWA.CHRISTOPHER L. MARTINLIC. NO.P25714DATE:MY LICENSE RENEWAL DATE IS12/31/2026PAGES OR SHEETS COVERED BY THIS SEAL:SHEET S.0104/20/2026HENRY COUNTY, IAMAP OF THECITY OF MOUNT PLEASANTHENRY COUNTY, IAPROFESS IONALFORREST A.MARTINSONP28860I OWAI HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WASPREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISIONAND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEERUNDER THE LAWS OF THE STATE OF IOWA.FORREST A. MARTINSONLIC. NO. P28860DATE: 04/20/2026MY LICENSE RENEWAL DATE IS12/31/2027PAGES OR SHEETS COVERED BY THIS SEAL:SHEETS A.01 - R.01430 E GRAND AVENUE, SUITE 101DES MOINES, IA 50309Phone: (515) 259-9190DESIGNEDFAMDRAWNTJNCHECKEDREV DESCRIPTION0 ISSUED FOR BIDDATE04/027/2026IOWA DEPARTMENT OF ADMINISTRATIVE SERVICESDPS POST 13 - UPPER PARKING LOT REPLACEMENTSHEETA.01Email: DesMoines@bolton-menk.comFAMRwww.bolton-menk.comCLIENT PROJ. NO.TITLE SHEET9511.000EXISTING TOPOGRAPHIC SYMBOLSACCESS GRATEAC AIR CONDITION UNITANTENNAAUTO SPRINKLER CONNECTIONBARRICADE PERMANENTBASKETBALL POSTBENCHBBIRD FEEDERBBOLLARDBUSHCATCH BASIN RECTANGULAR CASTINGCATCH BASIN CIRCULAR CASTINGCURB STOPCO CLEAN OUTCLVT CULVERT ENDDRINKING FOUNTAINDOWN SPOUTEV ELECTRIC CAR CHARGE STATIONFFILL PIPEFIRE HYDRANTFLAG POLEFLARED END / APRONFUEL PUMPGRILLGUY WIRE ANCHORH HANDHOLEHANDICAP SPACEIRRIGATION SPRINKLER HEADIRRIGATION VALVE BOXCP LIFT STATION CONTROL PANELLLIFT STATIONLIGHT POLEMAILBOXC MANHOLE-COMMUNICATIONEMANHOLE-ELECTRICG MANHOLE-GASH MANHOLE-HEATW MANHOLE-RECLAIMED WATERSMANHOLE-SANITARY SEWERD MANHOLE-STORM SEWERU MANHOLE-UTILITYW MANHOLE-WATERM METERDRIVE-THRU MICROPHONEPARKING METERPAVEMENT MARKINGC PEDESTAL-COMMUNICATIONEPEDESTAL-ELECTRICPEDESTRIAN PUSH BUTTONPICNIC TABLEPOLE-UTILITYPPOSTRAILROAD SIGNAL POLEG REGULATION STATION GASSATELLITE DISHSIGN TRAFFICSIGNAL CONTROL CABINETSOIL BORINGSIRENTELEPHONE BOOTHTILE INLETTILE TILE OUTLETTILE RISERTRANSFORMER-ELECTRICTREE-CONIFEROUSTREE-DEADTREE-DECIDUOUSTREE STUMPTRAFFIC ARM BARRIERTRAFFIC SIGNALTRASHTRASH CANUUTILITY MARKERVALVEVALVE POST INDICATORVALVE VAULTVVAULTVVENT PIPEWS WATER SPIGOTWELLWETLAND DELINEATED MARKERWETLANDWW WET WELLYYARD HYDRANTPROPOSED TOPOGRAPHIC SYMBOLSCLEANOUTMANHOLELIFT STATIONSTORM SEWER CIRCULAR CASTINGSTORM SEWER RECTANGULAR CASTINGSTORM SEWER FLARED END / APRONSTORM SEWER OUTLET STRUCTURESTORM SEWER OVERFLOW STRUCTURECURB BOXFIRE HYDRANTWATER VALVEWATER REDUCERWATER BENDWATER TEEWATER CROSSWATER SLEEVEWATER CAP / PLUGRIP RAPDRAINAGE FLOWTRAFFIC SIGNSLIGHT POLERSURVEY SYMBOLSBENCHMARK LOCATIONCONTROL POINTMONUMENT FOUNDEXISTING TOPOGRAPHIC LINESSURVEY LINESoooR/WR/WR/WR/WR/WR/WEXISTING UTILITY LINES| FM || FM |> SS >> SS >> SS >> SSS >> SSS >>> ST >>>> ST >>>> DT >>>> DT >>WMWMWSWSWSWSWRWRWRWRWRWRPROPOSED UTILITY LINES| FM |> SS >> SSS >>> ST >>>> DT >>WMWSWS> SS >| FM |> SS >> SSS >>> ST >>>> DT >>WMWSWS> SS >GRADING INFORMATIONCAST IRON MONUMENTSTONE MONUMENTRETAINING WALLFENCEFENCE-DECORATIVEGUARD RAILTREE LINEBUSH LINECONTROLLED ACCESSBOUNDARYCENTERLINEEXISTING EASEMENT LINEPROPOSED EASEMENT LINEEXISTING LOT LINEPROPOSED LOT LINEEXISTING RIGHT-OF-WAYPROPOSED RIGHT-OF-WAYSETBACK LINESECTION LINEQUARTER LINESIXTEENTH LINETEMPORARY EASEMENTFORCEMAINSANITARY SEWERSANITARY SERVICESTORM SEWERSTORM SEWER DRAIN TILEWATERMAINWATER SERVICERECLAIMED WATERFORCEMAINSANITARY SEWERSANITARY SERVICESTORM SEWERSTORM SEWER DRAIN TILEWATERMAINWATER SERVICEPIPE CASINGTRENCHLESS PIPE (PLAN VIEW)TRENCHLESS PIPE (PROFILE VIEW)952950952950G/LG/L953.531:4STA:5+67.19980.87EXISTING CONTOUR MINOREXISTING CONTOUR MAJORPROPOSED CONTOUR MINORPROPOSED CONTOUR MAJORPROPOSED GRADING LIMITS / SLOPE LIMITSPROJECT LIMITSPROPOSED SPOT ELEVATIONRISE:RUN (SLOPE)430 E GRAND AVENUE, SUITE 101DES MOINES, IA 50309Phone: (515) 259-9190Email: DesMoines@bolton-menk.comwww.bolton-menk.comDESIGNEDFAMDRAWNTJNCHECKEDFAMCLIENT PROJ. NO.9511.000REV DESCRIPTION0 ISSUED FOR BIDEXISTING PRIVATE UTILITY LINESNOTE:EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFYEXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY IOWA ONE CALL - 1-800-292-8989THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS UTILITY LEVEL WASDETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINE FOR INVESTIGATING AND DOCUMENTINGEXISTING UTILITIES".FFEEGGCCOEOEOCOCOUOUFFEEGGCCOEOEOCOCOUOUUNDERGROUND FIBER OPTICUNDERGROUND ELECTRICUNDERGROUND GASUNDERGROUND COMMUNICATIONOVERHEAD ELECTRICOVERHEAD COMMUNICATIONOVERHEAD UTILITYUTILITIES IDENTIFIED WITH A QUALITY LEVEL OTHER THAN D:LINE TYPES FOLLOW THE FORMAT: UTILITY TYPE - QUALITY LEVELEXAMPLE:G-AG-AUNDERGROUND GAS, QUALITY LEVEL AUTILITY QUALITY LEVEL (A,B,C,D) DEFINITIONS CAN BE FOUND IN CI/ASCE 38-22.UTILITY QUALITY LEVELS:LEVEL D - INFORMATION COMES SOLELY FROM EXISTING UTILITY RECORDS.LEVEL C - SURVEYING ABOVE GROUND UTILITY FACILITIES, SUCH AS MANHOLES, VALVE BOXES, ETC; AND CORRELATING THIS INFORMATION WITHEXISTING UTILITY RECORDS.LEVEL B - THE USE OF SURFACE GEOPHYSICAL TECHNIQUES TO DETERMINE THE EXISTENCE AND HORIZONTAL POSITION OF UNDERGROUNDUTILITIES.LEVEL A - THE USE OF NONDESTRUCTIVE DIGGING EQUIPMENT AT HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES, AS WELLAS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS.ABBREVIATIONSAADJALTB-BBLDGBMPBRBVCBC&GCIPCIPPCLCL.CMPC.O.COMMCSPCLVTDIADIPDWYEESMTELECELEV/ELEOFEREXFESF-FFFF&IFMFOF.O.GRANGRAVGUALGEBRAIC DIFFERENCEADJUSTALTERNATEBACK TO BACKBUILDINGBEST MANAGEMENT PRACTICEBEGIN RADIUSBUTTERFLY VALVECATCH BASINCURB AND GUTTERCAST IRON PIPECURED-IN-PLACE PIPECENTER LINECLASSCORRUGATED METAL PIPECHANGE ORDERCOMMUNICATIONCORRUGATED STEEL PIPECULVERTDIAMETERDUCTILE IRON PIPEDRIVEWAYEXTERNAL CURVE DISTANCEEASEMENTELECTRICELEVATIONEMERGENCY OVERFLOWEND RADIUSEXISTINGFLARED END SECTIONFACE TO FACEFINISHED FLOORFURNISH AND INSTALLFORCEMAINFIBER OPTICFIELD ORDERGRANULARGRAVELGUTTERGVHDPEHHHMAHPHWLHYDIKLLOLPLTMHMINMRNICNMCNTSNWLOHWPCPCCPEPEDPERFPERMPIPLPRCPTPVCPVMTRRCPRETR/WRSCRTGATE VALVEHIGH DENSITY POLYETHYLENEHANDHOLEHOT MIX ASPHALTHIGH POINTHIGH WATER LEVELHYDRANTINVERTCURVE COEFFICIENTLENGTHLOWEST OPENINGLOW POINTLEFTMANHOLEMINIMUMMID RADIUSNOT IN CONTRACTNON-METALLIC CONDUITNOT TO SCALENORMAL WATER LEVELORDINARY HIGH WATER LEVELPOINT OF CURVEPORTLAND CEMENT CONCRETEPERMANENT EASEMENTPEDESTRIAN, PEDESTALPERFORATED PIPEPERMANENTPOINT OF INTERSECTIONPROPERTY LINEPOINT OF REVERSE CURVEPOINT OF TANGENTPOLYVINYL CHLORIDE PIPEPAVEMENTRADIUSREINFORCED CONCRETE PIPERETAININGRIGHT-OF-WAYRIGID STEEL CONDUITRIGHTSANSCHSERVSHLDSTASTDSTMTCTETEMPTNHTPTYPVCPVERTVPCVPIVPTWMWSSANITARY SEWERSCHEDULESERVICESHOULDERSTATIONSTANDARDSTORM SEWERTOP OF CURBTEMPORARY EASEMENTTEMPORARYTOP NUT HYDRANTTOP OF PIPETYPICALVITRIFIED CLAY PIPEVERTICALVERTICAL POINT OF CURVEVERTICAL POINT OF INTERSECTIONVERTICAL POINT OF TANGENTWATERMAINWATER SERVICEACACRESCFCUBIC FEETCVCOMPACTED VOLUMECYCUBIC YARDEAEACHEVEXCAVATED VOLUMELBPOUNDLFLINEAR FEETLSLUMP SUMLVLOOSE VOLUMESFSQUARE FEETSVSTOCKPILE VOLUMESYSQUARE YARDDATE04/027/2026IOWA DEPARTMENT OF ADMINISTRATIVE SERVICESDPS POST 13 - UPPER PARKING LOT REPLACEMENTLEGENDSHEETA.02R7-8 SIGNRESERVEDPARKING18"EXISTING PAVEMENT, 5-6.5", REFER TOGEOTECH REPORT AND G.01 FOR LOCATIONS1 EXISTING PAVEMENTNOT TO SCALE1/2" EXPANSION JOINTAND POLYURETHANE SEALANT2' DETECTABLEWARNINGSIDEWALK, PCC, 4 INCH, CLASS CSUBBASE, MODIFIED, 4 INCH2 SIDEWALK, PCC, 4 INCH, CLASS CNOT TO SCALE1.5% TARGET, 2.0% MAX6 INCH CURB AT LANDINGSEE L.01 FOR TAPER ON RAMP1'PAVEMENT, PCC, 6 INCHSUBBASE, MODIFIED, 6 INCH12 INCH SUBGRADE PREPARATIONSIDEWALK, PCC, 6 INCHSUBBASE, MODIFIED, 4 INCH5 CLASS 'A' SIDEWALK AT LANDINGNOT TO SCALEPAVEMENT, PCC, 6 INCH, CLASS CSUBBASE, MODIFIED, 6 INCH12 INCH SUBGRADE PREPARATION3 PAVEMENT, PCC, 6 INCH, CLASS CNOT TO SCALER78PG SIGN7'VANACCESSIBLER7-8bFOR VAN ACCESSIBLESPACES ONLY2" SQUARE STEELPOST (14 GAUGE)2-1/4" OUTER SOCKETTO BE 2-3" ABOVEGRADEBOTTOM OF 2"SQUARE STEEL POST4'2-1/4" OUTERSOCKET(12 GAUGE)4 SIGN INSTALLATIONNOT TO SCALE1/2" EXPANSION JOINTAND POLYURETHANE SEALANT1/2" EXPANSION JOINTAND POLYURETHANE SEALANT2'TAPER1.5% TARGET, 2.0% MAXSEE L.01 FOR TAPER ON RAMP1'PCC, 6 INCH MIN.SUBBASE, MODIFIED, 4 INCHPAVEMENT, PCC, 6 INCHSUBBASE, MODIFIED, 6 INCH12 INCH SUBGRADE PREPARATION6 CLASS 'A' SIDEWALK AT RAMPNOT TO SCALE2'TAPER1.5% TARGET, 2.0% MAXEXISTING DOWNSPOUT,LENGTH TO BE MODIFIED FORBOOT INSTALLATION.CONTRACTOR TO VERIFY SIZEPRIOR TO ORDERING BOOT.CLEAN OUT 12" MINIMUMABOVE GRADESEE PLANS FOR GRADE12" MINIMUM COVERABOVE BOOT ADAPTORCLEANOUT2x MINIMUM CONCRETE ANCHOR BOLTTO BRICK BUILDING. RUBBER SPACER ORAS REQUIRED BY MANUFACTURER.DOWNSPOUTBOOT ADAPTORR7330 SIGNVISITORPARKING 18"2" SQUARE STEELPOST (14 GAUGE)7'2-1/4" OUTER SOCKETTO BE 2-3" ABOVEGRADEPCC, 4 INCH MIN.SUBBASE, MODIFIED, 4 INCHPAVEMENT, PCC, 6 INCHSUBBASE, MODIFIED, 6 INCH12 INCH SUBGRADE PREPARATION7 CLASS 'A' SIDEWALKNOT TO SCALER4 INCH PVC TO DRAIN,SEE PLANS FOR CONTINUATION90 DEGREE SWEEP, OR2x 45 DEGREE BENDS430 E GRAND AVENUE, SUITE 101DES MOINES, IA 50309Phone: (515) 259-9190Email: DesMoines@bolton-menk.comwww.bolton-menk.com8 CASTIRON DOWNSPOUT BOOTNOT TO SCALEDESIGNEDREVFAMDRAWN0TJNCHECKEDFAMCLIENT PROJ. NO.9511.000DESCRIPTIONISSUED FOR BIDDATE04/027/2026BOTTOM OF 2"SQUARE STEEL POST4'2-1/4" OUTERSOCKET(12 GAUGE)9 SIGN INSTALLATIONNOT TO SCALEIOWA DEPARTMENT OF ADMINISTRATIVE SERVICESDPS POST 13 - UPPER PARKING LOT REPLACEMENTTYPICAL SECTIONSSHEETB.01Edge with 1/8 inch toolfor length of jointSee Detail CT'B'PLAIN JOINT(Abutting Pavement Slabs)See Detail A or BT'C'CONTRACTION JOINTSee Detail FResilientJoint Filler1'' Nominal'E'1'' EXPANSION JOINTSee Detail D-2T'L'CONTRACTION JOINTTJoint Bars Bar Length and Spacing< 8'''L-1'#4 36'' Long at 30'' Centers'L-1' interchangeable with 'BT-1' subject to pouring sequencePavement Edge9'' min. 15'' min.THole Diameter 1/8''Larger than Tie Bar24'' Long #4 Tie Barat 12'' Centers.'RT'ABUTTING PAVEMENT JOINTRIGID TIENOTES:1. JOINT DETAILS SHOWN ARE PROJECT SPECIFIC SUDAS DETAILS ASREFERRED TO ON SHEET D.022. CHANGES IN CONSTRUCTION ACTIVITIES MAY REQUIRE THEIMPLEMENTATION OF OTHER JOINT DETAILS.3. REFER TO 7010.101 (PV-101) FOR FULL LIST OF SUDAS JOINT DETAILS4. REFER TO 7010.102 (PV-102) FOR FULL LIST OF SUDAS CURB DETAILS34'' Dia. Hole for BT-3and BT-4 Joint58'' Dia. Hole for BT-5JointSawing and Sealingof Joint not requiredT9'' min. 15'' min.'BT'ABUTTING PAVEMENT JOINT - RIGID TIE (Drilled)TJoint Bars Bar Length and Spacing< 8'' 'BT-5'#4 24'' Long at 30'' CentersTop of CurbBottom of Saw CutJoint SealantMaterialSaw Cut1 21''Top of SlabT/4 ± 1/4'''C'JOINT IN CURB(Match 'CT', 'CD', or 'C' joint in pavement.)See Detail F, Predrill orpreform holes in joint materialfor appropriate dowel size.T18'' Long 3/4" Dowelat 12'' CentersWidth(See Detail F)'ED'Hole Diameter 1/8''Larger than DowelDOWELED EXPANSION JOINTT/2 TL/2LBAR PLACEMENT(Applies to all joints unless otherwise detailed.)Top of PavementSealant21" to 34''SECTION A-A(Detail at Edge of Pavement)FORMGRADEELEV.721''421''6"R 3"R 3"Slope asper plans6" STANDARD CURBJoint Sealant Material41'' ± 81''41'' ± 116'' Saw CutASaw CutT/4 ± 1/4''.ACrack orJoint LineDETAIL A(Saw cut formed by conventional concrete sawing equipment.)Joint Sealant Material41'' ± 81''1 41'' ± 41''81'' to 156'' Saw CutACrack orAJoint LineDETAIL B(Saw cut formed by approved early concrete sawing equipment.)Joint Sealant Material41'' ± 81''41'' ± 116'' Saw CutA1 41'' ± 41'' Saw CutCrack orAJoint LineDETAIL CJoint Sealant Material41'' ± 116'' Saw CutT/3 ± 41''Crack orJoint LineDETAIL D-2DESIGNEDREV DESCRIPTION430 E GRAND AVENUE, SUITE 101DES MOINES, IA 50309Phone: (515) 259-9190Email: DesMoines@bolton-menk.comFAMDRAWNTJNCHECKEDFAM0 ISSUED FOR BIDRwww.bolton-menk.comCLIENT PROJ. NO.9511.00015 M21''aJteoriniatlSealantJoint58''FillerDETAIL FDATE04/027/2026IOWA DEPARTMENT OF ADMINISTRATIVE SERVICESDPS POST 13 - UPPER PARKING LOT REPLACEMENTTYPICAL DETAILSSHEETB.02ITEM NO.123456789101112131415161718192021222324252627282930ESTIMATED PROJECT QUANTITIES - BASE BIDITEM CODEITEMUNIT2010-CCLEARING, GRUBBING, AND LANDSCAPE REMOVALSLS2010-D-1TOPSOIL, ON-SITECY2010-EEXCAVATION, CLASS 10CY2010-GSUBGRADE PREPARATIONSY2010-JSUBBASE, MODIFIED, 6 INCHESSY4020-E-1TILE, TRENCHED, 4 INCHLF4020-999-A DOWNSPOUT BOOT, CASTIRONLS7010-APAVEMENT, PCC, 6 INCH, C4-WR-C20SY7030-A-1REMOVAL OF SIDEWALKSY7030-ESIDEWALK, PCC, 4 INCHSY7030-ESIDEWALK, CLASS 'A', PCC, 6 INCHSY7030-GDETECTABLE WARNINGSF7030-999-A REMOVAL OF STOOP SLABLS7030-999-A REPLACE STOOP SLAB ON EXISTING STOOP FOUNDATIONLS7040-HPAVEMENT REMOVALSY8020-BPAINTED PAVEMENT MARKINGS, SOLVENT/WATERBORNESTA8020-GPAINTED SYMBOLS AND LEGENDS, WATERBORNE OR SOLVENTEA8040-ATRAFFIC SIGNS, ADAEA8040-ATRAFFIC SIGNS, VISITOR, 12X18EA8040-DPERFORATED SQUARE STEEL TUBE POSTSLF8040-GPERFORATED SQUARE STEEL TUBE POSTS ANCHORS, BREAKAWAY, 2 INCHEA8040-IREMOVE SIGNSEA8040-999-X SALVAGE AND REINSTALL MAILBOXEA9010-BHYDRAULIC SEEDING, SEEDING, FERTILIZING, AND MULCHING, TYPE 1 - PERMANENT LAWNAC9020-ASODSY9040-F-1WATTLE, COMPOST/MULCH SOCKLF9040-F-2WATTLE, REMOVALLF11010-ACONSTRUCTION SURVEYLS11020-AMOBILIZATIONLS11030-AMAINTENANCE OF POSTAL SERVICELSQUANTITY1161210141814186011307905939121113092112303410.323010001000111AS-BUILT QTY.ITEM NO.A1ITEM CODE7030-999-AESTIMATED PROJECT QUANTITIES (ALTERNATE A)ITEMREMOVAL OF STOOP FOUNDATION, INSTALL STOOP FOUNDATION AND SLABUNITLSQUANTITY1AS-BUILT QTY.430 E GRAND AVENUE, SUITE 101DES MOINES, IA 50309Phone: (515) 259-9190DESIGNEDFAMDRAWNTJNCHECKEDREV DESCRIPTION0 ISSUED FOR BIDDATE04/027/2026IOWA DEPARTMENT OF ADMINISTRATIVE SERVICESDPS POST 13 - UPPER PARKING LOT REPLACEMENTSHEETC.01Email: DesMoines@bolton-menk.comFAMRwww.bolton-menk.comCLIENT PROJ. NO.QUANTITIES9511.000
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
- NAICS 237310Highway, Street, and Bridge Construction
- NAICS 238990All Other Specialty Trade Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
7th Avenue at Cedar River Wat...
Bid Number Bid Title Bid Type Organization Bid Issue Date Bid Close Date
City of Cedar Rapids
Bid Due: 7/08/2026
Ruminant Nutrition Laboratory...
Bid Number Bid Title Bid Type Organization Bid Issue Date Bid Close Date
Iowa State University
Bid Due: 7/15/2026