Addendum No. 1: Stormwater Maintenance Equipment Rebid
Project Information
- Bid Title
- Addendum No. 1: Stormwater Maintenance Equipment Rebid
- Issuing Agency
- Borough of Seaside Park
- Location
- New Jersey
- Published Date
- Apr 6, 2026
- Closing Date
- Apr 16, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Description Opening Date Closing Date
Addendum No. 1: Stormwater Maintenance Equipment Rebid
April 06, 2026
12:50
PM
April 16, 2026
11:00
AM
- Attachment Preview
-
BOROUGH OF SEASIDE PARKOCEAN COUNTY, NEW JERSEYOUR FILE: 1528-U-088NJIB CLEAN WATER APPLICATION STORMWATER MAINTENANCEEQUIPMENT REBIDADDENDUM #1April 6, 2026The following additions to the Contract Documents will be written into any Contract for the“NJIB CLEAN WATER APPLICATION STORMWATER MAINTENANCEEQUIPMENT REBID” project and must be taken into account in rendering a Proposal for thework.The following items shall be revised as follows at this time:1. Section 11200 “VACUUM COMBINATION STORM SEWER CLEANER” of thetechnical specifications has been revised. The revised Section 11200 “VACUUMCOMBINATION STORM SEWER CLEANER” can be found attached to thisaddendum.All specifications and bids shall be revised accordingly.Please complete the “Acknowledgement of Receipt of Addenda” (Page P-3), attachedhereto, for receipt of this Addendum letter and include with bid documents submission.The Acknowledgement of receipt of addenda page is a mandatory required document andfailure to submit shall be deemed a fatal defect.Alan B. Dittenhofer, PE, PP, CMENJ PE License #37672SEAL1528U088 Addendum #1_Rebid.docPAGE 1SECTION 11200VACUUM COMBINATION STORM SEWER CLEANERPART I – GENERAL1.01 SUMMARYThis section includes the requirements for furnishing and delivering a Vactor 2100i 10 Yd. Debris Combo(or approved equal) Vacuum Combination Storm Sewer Cleaner with a water Capacity of 1000 gallons.The contractor shall perform all necessary operations and furnish all tools, equipment, labor, and materials instrict accordance with the Bid documents to complete the required work of this section. The unit shall be anew model. No discontinued models will be accepted. The equipment must be BABA (Build America, BuyAmerica) compliant. Federal infrastructure investments obligated on or after May 14, 2022, must complywith the Build America, Buy America (BABA) Act, which requires the use of domestic iron and steel,manufactured products, and construction materials in covered infrastructure projects. Products thatqualify for a de minimis waiver cumulatively may comprise no more than a total of five percent of thetotal project cost, otherwise a project specific SRF Waiver must be obtained.Bids will be accepted for consideration on any make or model that is equal or superior to the equipmentspecified. Decisions of equivalency will be at the sole interpretation of the Purchasing and Public ServicesDirector.Bidder may be required to demonstrate a reasonable likeness of the equipment being offered within areasonable time of request. The equipment demonstrated shall be equipped with all accessories andcomponents required in this specification to ascertain equivalence.1.02 RELATED SECTIONS1. Appendix: The Appendix, located within the Technical Specifications, contains a ComplianceWorksheet for Contractor’s submitting “approved equal” equipment and accessories.1.03 SERVICE AND SUPPORT1. Location of warranty service center and amount of inventory shall be noted which may beverified and inspected.1.04 SUBMITTALSA. A submittal shall be made with the Bid Package for the proposed Vacuum Combination StormSewer Cleaner. The submittal shall consist of one concise document containing the following:1. Cover page2. An information section for the Vacuum Combination Storm Sewer Cleaner containing at leastthe following:a. Catalog Cut containing descriptive literature of model featuresb. Equipment Specifications (Water capacity, debris capacity, body color, tool storage,transmission intake pipe sizing, controls, rotatable boom inlet hose specifications, camerasystem specifications, dimensions, operating specifications, cab features, chassisspecifications, length, height, and Engine specifications)c. Manufacturer warranty information (see 1.05)Vacuum Combination Storm Sewerd. Completed compliance worksheet found in the appendix for Contractor’s seeking anapproved equal vacuum truck and accessories.1.04 DELIVERY, STORAGE, AND HANDLINGA. Schedule delivery of the vacuum truck and associated equipment as to avoid delays and disruptionsto the Borough.B. Schedule by coordinating with the Engineer’s Office. Delivery will be at a location specified bythe Borough in the Borough of Seaside Park.C. Handle and transport equipment in compliance with the manufacturer’s recommendation and in amanner satisfactory to the Engineer.D. If damage, theft, or loss of materials occurs prior to documented completion of unit delivery, theContractor shall be held responsible with no additional payment(s). Damage after documentedcompletion of unit delivery, if by fault of the Contractor or related parties shall also be theContractor’s responsibility.1.05 WARRANTYA. Truck chassis shall be covered by a (1) One year base warranty 100% parts & labor. Basewarranty shall include (1) Year towing coverage for up to 500.00 per occurrence. Diesel enginewarranty shall be Five (5) years / 100,000 miles 100% parts and labor. Coverage shall include:turbocharger, injectors, engine electronics, and water pump as well as the EmissionAftertreatment System. Chassis/Frame warranty shall be five (5) years/ unlimited miles 100%parts and labor.B. The manufacturer shall provide a warranty of a minimum of five (5) years for the water tank, five(5) years on debris tank, one (1) year Positive displacement blower, and two (2) years on thewater pump. All other equipment including the truck/chassis shall be warranted a minimum ofone (1) year from the date of receipt and acceptance of the equipment. The engine shall becovered by the warranty for five (5) years including after treatment and the transmission shall becovered by the warranty for three (3) years. The warranty shall cover both parts and labor torepair any defective parts or assemblies. Bidders must include warranty statement for both chassisand body. It is the responsibility of the manufacturer to deliver the entire unit to the Borough.C. Copies of all warranty certificates shall be submitted with the bid to allow personnel to comparewarranties. If no warranty certificates are submitted, the bid will be considered incomplete andwill be rejected.D. The bidding dealer shall be perform all warranty work and shall not sub-contract any warrantywork.PART 2 – PRODUCTS2.01 MANUFACTUERED UNITSThe equipment shall be of the quality and rating as specified herein, and the manufactured unitsshall be as follows:Vacuum Combination Storm SewerA. Truck Mounted Single Engine Combination Sewer Cleaner and chassis:1. Vactor 2100i 10 Yd. Debris Combo2. Approved Equal2.02.1 COMPONENTS AND FEATURESA. Engine:1. The engine shall be designed, manufactured and warranted by the machine manufacturer toensure maximum compatibility to the other major components.2. The engine shall meet U.S. EPA Tier 4 Interim emission standards.3. The rated net power shall be 370 hp.4. The air cleaner shall feature a two stage filter and include an air filter service indicator toidentify the need for filter cleaning or changing.5. A 120-volt engine coolant heater and glow plugs shall be provided for improved starting incold weather.6. The engine shall have replaceable valve guides and valve seats for extended service life7. There shall be an electric fuel priming pump to facilitate engine starting after servicing thefuel system.8. The engine shall have fan guards to prevent access when the engine is running.9. There shall be a quick release fuel filter / water separator for protection of the engine fuelsystem from contaminated fuel.10. The starting and charging system shall be 12 volt.11. Extended life coolant shall be used.12. The engine compartments shall be lockable13. A non-spill engine oil drain valve shall be providedB. Transmission / Power Train (Allison 3000 RDS Automatic Transmission):1. An inching function transmission neutralizer shall be provided2. The machine design shall not allow starting the machine when the transmission shifter isengaged in forward or reverse.3. The transmission shall neutralize when the parking brake is applied, making it impossible todrive through the parking brake.4. Maximum torque to the wheels shall be possible without down shifting the transmission.C. Automatic Chassis:The machine shall be mounted on a 2026 Peterbilt model 548 or equal Automatic Chassis.D. Subframe:1. The equipment shall be of modular design consisting of vacuum system, water tanks system,debris body and drive system.2. A sub frame shall be fabricated to the exact dimensions of the truck chassis for mounting ofmodular components.3. All components of the module shall attach to the sub frame and not directly to the chassis.4. Sub frame shall be designed to ASME standards for maximum applied loads, chassis framemovement and even distribution of weight to the chassis and suspension.Vacuum Combination Storm Sewer5. Sub frame shall be continuous and uninterrupted from back of cab to end of frame.E. Debris Body:1. The debris body is to be made of abrasion and corrosion resistant steel with 3/16" thickness, aminimum yield point of 50,000 PSI, and minimum tensile strength of 70,000 PSI. Mild steel ofany thickness is deemed unacceptable.2. The debris body is to be round for maximum strength and ease of dumping and is to have aminimum useable capacity of 10 cubic yards. (Not to exceed 35 ft).3. The body is to have a full-sized rear door hydraulic open and close that is hinged at the top andthat is equipped with a replaceable neoprene type seal to prevent leakage. A hydraulic door locksystem is to be mounted on a flat rear door of the debris body. The system is to be activated atthe same curbside location as the debris body dump control to protect the operator fromdischarged materials, The dump controls are enclosed in a locking control box.4. Dual outward mounted rear door props shall be included as standard to prevent operator fromentering door swing path when engaging rear door prop.5. For optimal particulate separation, vacuum shall be drawn from separate ports in the top of thedebris body.6. Body shall be dumped by raising the body to a 50-degree angle utilizing a forward mounted,double acting hydraulic dump cylinder.7. Dump controls, accessory controls, e-stop control shall be provided at a central curb side locationdirectly behind the cab of the truck.8. For stability and safety, dumping must be accomplished while the pivot point of the body remainsfixed to the subframe.9. Industrial style rear debris body door shall be flat and shall open and close hydraulically bycylinders mounted at the top of the body. Door shall open 50 degrees from the fully closedposition. Door shall be unlocked, opened, closed, and locked by a failsafe hydraulically activatedsequential positive locking system, cam operated by a single hydraulic cylinder, with all controlslocated behind truck cab, forward of the debris body, so operator is not subject to sewage whendumping.10. The body is to be equipped with a load level indicator to show the load level and when the bodyis loaded to capacity. The rear door is to be equipped with two 6" body drain valve and drainhose that will allow the operator to drain off excess liquids while retaining solids for greater on-site productivity. (Located at 6:00 and 3:00 position with knife valve).11. The debris body shall be equipped with a rear door drain to drain off excess liquids whileretaining solids. No valve included12. The debris body shall be equipped with a rear door drain at bottom dead center to drain off excessliquids with an internal screen to prevent large solids from passing. A manually operated 6" knifevalve with cam-lock coupler and 25' of lay flat hose having camlock quick connects shall beincluded at this location.13. Full Swinging Decant Screen: Available Only on Valve Installed At Lowest Point In Door shallbe provided.14. (4) Dual vertical (cyclone) centrifugal separators shall be installed in-line between the debrisbody and the air mover, (2) per side for each debris body discharge port. Each dual separator shallinclude large fallout chamber cleanout door.15. For safety, a minimum of (5) vacuum tubes shall be stored on curbside storage racks to minimizeoperator exposure to traffic side of unit. Shall include quick release retainer handles (no bungeesor clamps).16. A curbside, folding 3-pipe rack shall be provided, constructed of steel tubing, spring assisted.Shall include quick release retainer handles (no bungees or clamps).Vacuum Combination Storm Sewer
- Commodity Codes
-
- NAICS 811219Other Electronic and Precision Equipment Repair and Maintenance
- NAICS 811310Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Print Shop Machinery - Servic...
Project ID: 06Q-27 Title: Print Shop Machinery - Services, Repair and Maintenance Addenda:
Passaic Public Schools
Bid Due: 7/17/2026
PREVENTIVE MAINTENANCE AND RE...
Project ID: Title: PREVENTIVE MAINTENANCE AND REPAIR SERVICE TO VARIOUS LIFT STATIONS, PUMPS,
Middlesex County
Bid Due: 7/21/2026