RFQ - Materials Testing Services
Project Information
- Bid Title
- RFQ - Materials Testing Services
- Issuing Agency
- State Government of North Carolina
- Location
- North Carolina
- Published Date
- May 27, 2026
- Closing Date
- Jun 25, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- 345-05/27/2026
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Solicitation Number: 345-05/27/2026 Project Title: RFQ - Materials Testing Services Description: Cape Fear Public Utility Authority (CFPUA) desires to contract with a qualified materials testing firm to provide materials testing services associated with CFPUA Southside Water Reclamation Facility expansion project. Opening Date: 6/25/2026 2:00 PM Posted Date: 5/28/2026 Status: Open Department: CAPE FEAR PUBLIC UTILITY AUTHORITY Solicitation Number*345-05/27/2026DepartmentCAPE FEAR PUBLIC UTILITY AUTHORITYStatus ReasonOpenOpening Date2026-06-25T14:00:00.0000000Posted Date*2026-05-27T19:12:54.0000000ZPrimary Commodity CodeProfessional engineering servicesMandatory Conference/Site Visit——Special InstructionsNo pre-submittal meeting to be heldSolicitation Type*Select RFP IFB RFIOwnerTeresa McPhersonDescriptionCape Fear Public Utility Authority (CFPUA) desires to contract with a qualified materials testing firm to provide materials testing services associated with CFPUA Southside Water Reclamation Facility expansion project. - Attachment Preview
-
REQUEST FOR QUALIFICATIONSMATERIALS TESTING SERVICESFOR THE CAPE FEAR PUBLIC UTILITY AUTHORITYWILMINGTON, NORTH CAROLINAMay 27, 2026GENERALCape Fear Public Utility Authority (CFPUA) desires to contract with a qualified materials testingfirm to provide materials testing services associated with CFPUA Southside Water ReclamationFacility expansion project.This project includes the design of replacement and upgraded treatment facilities at the SouthsideWater Reclamation Facility (SSWRF) in Wilmington, North Carolina. Cape Fear Public UtilityAuthority (Owner) has contracted with HDR to serve as Owner’s Advisor (OA). CrowderConstruction Company (Design-Builder) and Hazen and Sawyer (Design Consultant) have beenselected as the Design-Builder and Design Consultant, respectively, as the Design-Build Team toconstruct the new plant. McKim and Creed is serving as a Design Sub-Consultant to Hazen forselected engineering related services.Southside Water Reclamation Facility is located at 3436 River Rd, Wilmington NC on propertyowned by CFPUA. The existing 12 MGD treatment plant will be expanded to 20 MGD. Designof the SSWWTP is generally restricted to the plant site (i.e. ‘inside the fence’) and is expected toinclude:• Modifications to the influent as it enters the SWRF• Preliminary Treatment Facility• Primary Clarifiers and Sludge Pumping• Secondary process: 3-stage BNR with Densification• Blower Facility• Secondary Clarifiers• Odor Control for Primary Treatment and Solids• RAS Pumping Station• Tertiary Disc filters• UV Disinfection• Outfall piping to riverbank• Non-Potable Water Pump Station• Dewatering Building• Liquid Sludge Storage Tanks• Cake Storage drainage improvements and push wall• Drain Pump Station• Administration Building with integrated Laboratory• Maintenance Building Storage (conversion of existing Dewatering Building)• Emergency Generators, switch gear facility and fuel storageThe work for the material testing firm may consist of, but not be limited to, soils testing toprovide soil percent compaction and soil classification; pavement testing to provide pavementthickness and density; concrete testing to provide material composition, temperature, slump,shrinkage, and strength; structural steel, welds, torque inspections; and any additional specialtyinspection (SI) required by building code. The selected firm will coordinate with CFPUAcontracted engineering consultants/inspectors, but report directly to the CFPUA. The selectedfirms will be expected to test materials for specified conditions and report results, includingbring attention to material conditions out of what is to be expected or ordinary.CFPUA hereby requests qualified firms to submit a Qualification Statement to provide materialstesting services for the Term of this agreement, which shall be for one (1) year upon execution ofthe contract with the option to renew for up to 5 additional one-year terms.SUBMISSION OF A STATEMENT QUALIFICATION (SOQ)Materials testing firms are invited to submit a Statement of Qualification to the CFPUAto be received no later than 2:00 PM on June 25, 2026. Submittals received after thisdeadline will not be considered.CFPUA will address questions regarding the RFQ until 2:00 PM on June 16, 2026.Questions submitted after this time will not addressed. Questions concerning thisadvertisement should be directed to Ben Guerrieri, Procurement Manager, CapeFear Public Utility Authority, at bids@cfpua.org.SOQ’s shall be limited to 25-pages or less, excluding cover page, table of contents,tabs, resumes and appendices.Firms shall submit their statement of qualifications for consideration in .pdf format tobids@cfpua.org. Maximum file size for .pdf submission is 25MB. A reply will be sent to theemail address submitting the statement of qualifications to confirm receipt. It is thesubmitting firms’ responsibility to confirm that CFPUA has received statement ofqualifications via email. If email reply is not received from bids@cfpua.org, please call910-332-6472 or 910-332-6651 before deadline for submission.Submitted information shall comply with N.C.G.S. 143-64.31 through 64.34 (aka MiniBrooks Act).All SOQ’s will be evaluated by a CFPUA selection team.EVALUATIONFirms submitting Statements of Qualifications to perform the Materials Testing Services will beevaluated based upon the firm's experience, knowledge and familiarity in materials testing,specifically related to large water and wastewater treatment plants expansions along withexperience with common soils found in this region of North Carolina. Firm shall also haveexperience with various roadway materials currently required by the North Carolina Departmentof Transportation (NCDOT) and the City of Wilmington, and various concrete mixes.SELECTIONCFPUA will follow a qualifications-based selection process. Firm must demonstrate their level ofcompetence and qualification, and each sub-consultant's level of competence and qualification, withrespect to the listed evaluation factors for the needed services.SOQ’s will be evaluated based on the following four (4) considerations and the level of importancefor each consideration. The SOQ shall be formatted consistent with the evaluation consideration.Criteria shown under each of the four (4) considerations are to be addressed in the SOQ.Consultant’s may provide additional information as necessary.Item1234Evaluation CriteriaProject understanding and approachRelevant firm experienceOverall staff experienceRecord of success by the consultantTotal Possible PointsMaximum Points203525201001. Project understanding and approach (20%)a. Understanding of testing requirements for a large plant expansion project,projects overall program and objectives2. Relevant firm experience (35%)a. Experience with material testing and specialty inspections.b. Projects of similar and scope3. Overall staff experience proposed for this project (25%)a. Adequate staffing/resources to perform the workb. Personnel staff with proper certificationsc. Organization Chart4. Record of success by the material testing firm (20%)a. Record of project success, demonstrated by work previously performed forCFPUA or similar work performed for othersb. Ability to compile with contractors schedule and flexibility with materialtesting and inspections (24/7).A more detailed scope of work and fee schedule will be negotiated with the best qualified firm.If negotiations are not successful with any selected firm, CFPUA will terminate negotiationswith that firm and initiate negotiations with the next best qualified firm.Qualifying Statements shall at a minimum include:1. Firm name, address, telephone number, fax number, email address, and contact person(s).2. Qualifications and experience of personnel who would be providing material testingservices for the project(s),a. Including a list of five (5) projects with similar materials testing to includei. a summary of the testing requirements and testing methods performed,ii. the owner of the projectINSURANCE REQUIREMENTSThe following criteria will be deemed necessary for selection:• The firm must meet the following insurance requirements. Workers Compensation maybe waived if firm has no employees.• General Liability $1,000,000 per occurrence/$2,000,000 aggregate. Authority must beadditional insured and endorsement required.• Workers Compensation $500,000/$500,000/$500,000. Waiver of Subrogation against theAuthority and endorsement required.• Auto Liability Insurance $1,000,000 per occurrence combined single limits applicable toclaims due to bodily injury and/or property damage. Authority must be additional insuredand endorsement required.• Professional Liability not less than $2,000,000 per loss.• Any firm wishing to be considered must be properly registered with the Office of theSecretary of State.CFPUA will select one firm to provide the materials testing services based on the criterion statedin this notice and other relevant materials that may be submitted by applicants.NOTIFICATIONThe selected firms will be notified by telephone and/or email.The CFPUA reserves the right to reject any and all Submittals.Any questions concerning this advertisement should be directed to Ben Guerrieri,Procurement Manager, Cape Fear Public Utility Authority, at bids@cfpua.org by June 16,2026, at 2:00pm. Questions submitted after this time will not be addressed.END
- Commodity Codes
-
- NAICS 541380Testing Laboratories
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Asbestos Inspection Services ...
Solicitation Number: 10474849-03-26 Project Title: Asbestos Inspection Services for Lee County Community Development
State Government of North Carolina
Bid Due: 7/07/2026
Construction Material Testing...
Solicitation Number: 367-OC5484 Project Title: Construction Material Testing and Special Inspections Services For
State Government of North Carolina
Bid Due: 7/07/2026