Deltona High - Reroof Bldg. 26
Project Information
- Bid Title
- Deltona High - Reroof Bldg. 26
- Issuing Agency
- Volusia County Schools
- Location
- Florida
- Published Date
- May 8, 2026
- Closing Date
- May 27, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Project No. 2648207
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Deltona High - Reroof Bldg. 26 - Project No. 2648207
Mandatory Prebid Meeting: May 8, 2026 at 9:30 AM Bid: May 27, 2026 at 1:00 PM Project Bid Documents: Plans
Project Manual
Prebid Sign-inEstimate: $138,000 Consultant: Terracon Consultants, Inc.
Engy Magdy
(407) 618-8371Owner: VCS Project Manager
Tony Franco
(386) 947-8786Bid Status: Active - Attachment Preview
-
VOLUSIACOUNTY SCHOOLSTHE SCHOOL BOARD OF VOLUSIACOUNTY FLORIDA200 North Clara AvenueDeland, Florida 32720DELTONA HIGH SCHOOLREROOF BLDG. 26VCS Project NO. 2648207100 WOLF PACK RUNDELTONA, FL 32725SCHOOL BOARDMEMBERSRUBEN COLONKRISTA GOODRICHDONNA BROSEMERJAMIE HAYNESJESSIE THOMPSONBOARD CHAIRBOARD VICE CHAIRMEMBERMEMBERMEMBERCARMEN J. BALGOBINSUPERINTENDENT1675 LEE ROADWINTER PARK, FL 32789PH. (407) 740-6110| TERRACON.COMTERRACON FL LICENSE NO. 8830DESCRIPTION OF WORKTHE GENERAL SCOPE OF WORK FOR THIS PROJECT INCLUDES ROOF REPLACEMENT WHERE INDICATED ON THE DRAWINGS.LOW-SLOPED ROOF AREA: REMOVE THE EXISTING GRAVEL SURFACED ASPHALT BUILT0UP ROOFING SYSTEM WHEREINDICATED AND INSTALL NEW MULTI-PLY MODIFIED BITUMEN MEMBRANE ROOFING SYSTEM.STEEP-SLOPED ROOF AREAS: REMOVE THE EXISTING TILE ROOF AND INSTALL NEW STANDING SEAM METAL ROOFINGSYSTEM.ENGINEERS & CONSULTANTSDISCIPLINE : ARCHITECTURALFIRM NAME: TERRACON CONSULTANTSADDRESS: 1675 LEE ROADADDRESS: WINTER PARK, FL 32789CONTACT PHONE NUMBER: 407-740-6110PROJECT MANAGER: ENGY MAGDYEMAIL ADDRESS: ENGY.MAGDY@TERRACON.COMWWW.TERRACON.COM1675 LEE ROADWINTER PARK, FL 32789PH. (407) 740-6110| TERRACON.COMTERRACON FL LICENSE NO. 8830Architect's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe Florida Building Code.BUILDING DATAA. SURVEY PARCEL IDB. LEGAL DESCRIPTIONC. OCCUPANCY TYPED. CONSTRUCTION TYPEE. RISK CATEGORYF. AUTOMATIC SPRINKLERG. BUILDING AREAH. BUILDING HEIGHTI. OCCUPANT LOADN/AN/AN/AN/AIIIN/A4100 SF16 FTN/ALOCATION MAPINDEX OF DRAWINGSG001G002A101A501A502A503COVER SHEETGENERAL NOTES , SITE PLAN AND LEGENDROOF PLANROOF DETAILSROOF DETAILSROOF DETAILSNOT TO SCALECONSTRUCTION DOCUMENTS 01/19/2026ENGR OF RECORDENGY MAGDY, P.E.ARCH/ENGR OF RECORDDESIGNED BYEMDRAWN BYWGISSUE DATE01/19/2026SHEET TITLEAE PROJECT NUMBERF9246313COVER SHEETDRAWING NO.G001GENERAL NOTESDESCRIPTION OF WORKTHE GENERAL SCOPE OF WORK FOR THIS PROJECT INCLUDES ROOF REPLACEMENT AS INDICATED ON THE DRAWINGS.1. ROOF AREA A: REMOVE THE EXISTING LOW-SLOPED GRAVEL SURFACED BUILT-UP ROOFING SYSTEM DOWN TO THE EXISTING METAL DECK AND INSTALL 2-PLY MODIFIED ROOFING SYSTEM ASINDICATED. REFER TO SHEET A501 FOR ROOF SYSTEM DETAILS.2. ROOF AREAS B AND C: REMOVE THE EXISTING CLAY TILE ROOF DOWN TO THE EXISTING ROOF DECK AND INSTALL NEW STANDING SEAM METAL PANELS ROOFING SYSTEM AS INDICATED. REFER TOSHEET A501 FOR ROOF SYSTEM DETAILS.DEMOLITION NOTES1. THE INFORMATION SHOWN ON THE DRAWINGS HAS BEEN COMPILED FROM VARIOUS SOURCES, AND MAY NOT REFLECT THE ACTUAL CONDITIONS AT THE TIME OF CONSTRUCTION. FIELD VERIFY ALLDIMENSIONS AND QUANTITIES.2. THE BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL SCHEDULE AND EXECUTE WORK TO AVOID INTERRUPTIONS TO BUILDING OPERATIONS.3. CONTRACTOR SETUP LOCATIONS SHALL BE AS INDICATED BY THE OWNER DURING THE PRE-CONSTRUCTION MEETING.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COVERING ALL INTERIOR ITEMS THAT MIGHT BE AFFECTED BY THE WORK, INCLUDING FLOORS AND EQUIPMENT PRIOR TO DEMOLITION. ONCEREMOVAL IS COMPLETE FOR THE DAY, THE PLASTIC COVERINGS SHALL BE REMOVED AND THE INTERIOR AREAS CLEANED. CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO, SWEEPING OF FLOORSAND DUST REMOVAL FROM THE TOPS OF LIGHT FIXTURES AND EQUIPMENT WHERE ACCESSIBLE.5. THE CONTRACTOR SHALL REPORT DETERIORATED OR UNSUITABLE ROOF DECK OR SUBSTRATE COMPONENTS TO THE OWNER PRIOR TO PERFORMING ROOFING INSTALLATION.6. REMOVE AND DISPOSE OF EXISTING ROOF SYSTEM AND ALL ASSOCIATED MATERIALS DOWN TO THE EXISTING STRUCTURAL DECK UNLESS OTHERWISE INDICATED ON THE DETAIL DRAWINGS TOREMAIN. REMOVE AND DISPOSE OF ALL ITEMS TO INCLUDE ROOFING, FLASHINGS, DETERIORATED BLOCKING, AND APPURTENANCES SCHEDULED TO BE REMOVED. REFER TO EXISTING ROOF SYSTEMCROSS SECTION INFORMATION ON THIS SHEET.7. PROVIDE TEMPORARY OVERHEAD PROTECTION AT THE MAIN ENTRANCE AND AT OTHER LOCATIONS AS NECESSARY TO PROVIDE UNINTERRUPTED ACCESS TO BUILDING.8. REMOVALS SHALL BE PERFORMED IN ACCORDANCE WITH THE SUBMITTED AND APPROVED REMOVAL PLAN, THE DETAIL DRAWINGS AND SPECIFICATIONS.9. HAZARDOUS MATERIALS: INDEPENDENT TESTING OF ROOFING MATERIALS INDICATES THAT THERE ARE NO HAZARDOUS MATERIALS WITHIN THE EXISTING ROOF SYSTEM AND FLASHINGS.INSTALLATION NOTES1. FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE ROOF PLANS HAS NOT BEEN INDICATED. EXISTING AND NEW DETAILS HAVE BEEN INDICATED FOR TYPICAL COMPONENTS AT RANDOMLOCATIONS.2. COMPONENTS SHOWN ON THE DETAIL DRAWINGS SHALL BE NEW UNLESS SPECIFICALLY INDICATED AS EXISTING.3. ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT.4. FOR THE SAKE OF CLARITY, SECUREMENT FASTENERS ARE NOT SHOWN ON THE DRAWINGS IN THEIR ENTIRETY. REFER TO SPECIFICATIONS FOR FASTENER TYPES/SPACING.5. ANY DISCREPANCIES ON THE DRAWINGS NOTED BY THE CONTRACTOR SHALL BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO BID SUBMISSION.6. ITEMS OF CONSTRUCTION SHALL BE 100% WATERTIGHT ON THE SAME DAY OF WORK. PHASED CONSTRUCTION MUST BE APPROVED BY THE OWNER PRIOR TO CONSTRUCTION.7. DETAILS NOT DEPICTED SHALL BE CONSTRUCTED IN A MANNER CONSISTENT WITH THE DETAIL DRAWINGS. FIELD VERIFY ALL DIMENSIONS.8. ALL DUMPSTERS MUST BE AT LEAST 15 FEET FROM THE BUILDING UNLESS EMPTIED AT THE END OF EACH WORK DAY.9. MATERIALS MAY NOT BE STORED CLOSER THAN 15 FEET FROM BUILDINGS AND MAY NOT BE PLACED IN FRONT OF EXITS OR ANY FIRE PROTECTION EQUIPMENT. REFUELING OF GASOLINE POWEREDEQUIPMENT WILL NOT BE PERMITTED ON THE ROOF. GASOLINE MUST BE STORED IN UL LISTED AND APPROVED CONTAINERS.10. METAL FABRICATION NOTES: FILE SMOOTH ALL EXPOSED SHARP EDGES. FABRICATE METAL TRANSITIONS AND TERMINATIONS IN ONE-PIECE CONSTRUCTION. LOCK AND SEAL OR SOLDER ALL JOINTSSOLID, AS SPECIFIED, TO MAKE WATERTIGHT.STATEMENT OF COMPLIANCE1. TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND THE PROJECT MANUAL ARE COMPLETE AND COMPLY WITH THE FLORIDA BUILDING CODE.2. BUILDING CODE REFERENCE: FLORIDA BUILDING CODE, 8TH EDITION (2023).SITE PLANPARKING LOTPARKING LOTPLAY AREAPLAY AREAPLAY AREAPLAY AREAPARKING LOTPARKING LOTPLAY AREAPARKING LOTPLAY AREABUILDING 26PARKING LOTPLAY AREAPLAY AREASTANDARD LEGEND AND SYMBOLSNOTE: NOT ALL SYMBOLS NECESSARILY USEDPARAPET WALLVTRVENT THROUGH ROOFROOF DRAINOFOVERFLOW THRU-WALL SCUPPERFEXHAUST FANEXISTING STRUCTURAL SLOPETAPERED INSULATION SLOPEWIND DESIGN INFORMATIONSPECIFIED PER FLORIDA BUILDING CODE (2023) CH. 16AND IN ACCORDANCE WITH ASCE 7-22ULTIMATE DESIGN WIND SPEEDBUILDING RISK CATEGORYWIND EXPOSUREINTERNAL PRESSURE COEFFICIENTBUILDING HEIGHT (MEAN)DESIGN WIND LOAD PRESSURES155 MPHIIIB0.18 (ENCLOSED)16 FTZONE 1'ZONE 1ZONE 2ZONE 31'-19.74 PSF1-34.37 PSF2-45.34 PSF3-61.79 PSFWIND UPLIFT INFORMATION10'324'110'10'211'14'2310'310'34'10'10'1234'310'1675 LEE ROADWINTER PARK, FL 32789PH. (407) 740-6110| TERRACON.COMTERRACON FL LICENSE NO. 8830ENGR OF RECORDENGY MAGDY, P.E.ARCH/ENGR OF RECORDDESIGNED BYEMDRAWN BYWGISSUE DATE01/19/2026AE PROJECT NUMBERF9246313SHEET TITLEGENERAL NOTES,SITE PLAN AND LEGENDDRAWING NO.G0025A5016OFA5015A5015A501TYP.F3A502VTRTYP.1A502TYP.3A502FVTRTYP.2A502TYP.2A502VTR1/4:12FTYP.3A502ROOF AREA CMEAN ELEV. = 13'±5A5028'-2" ±5:121A5035:126A5024A5025A501ROOF REPLACEMENT NOTESROOF AREA A:1. REMOVE THE EXISTING GRAVEL SURFACED ASPHALT BUILT-UP ROOF SYSTEM AND INSULATION DOWN TOTHE EXISTING METAL ROOF DECK. INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEM ANDINSULATION AS INDICATED. REFER TO ROOF SYSTEM CROSS SECTION DETAIL 1/A501.2. THE EXISTING METAL ROOF DECK IS SLOPED (1/4:12). INSTALL RIGID INSULATION (FLAT) OVER EXISTINGSLOPED ROOF DECK. PROVIDE MIN. 1/2:12 TAPERED INSULATION CRICKETS/SADDLES BETWEEN PRIMARYROOF DRAINS TO MAINTAIN POSITIVE SLOPE AS INDICATED.3. THE TAPERED LAYOUT IS CONCEPTUAL IN NATURE AND INTENDED TO PROVIDE A BASIC CONCEPT FORBIDDING PURPOSES. THE ACTUAL LAYOUT MAY VARY FROM THAT SHOWN. SUBMIT TAPERED INSUALTIONLAYOUT FOR REVIEW AS SPECIFIED.4. REMOVE AND REPLACE ROOF DRAINS AS INDICATED. PROVIDE 4-FTX4-FT MIN. TAPERED INSULATIONDRAIN SUMPS AT ALL ROOF DRAIN LOCATIONS AS INDICATED.5. REMOVE EXISTING EXHAUST FANS AND REINSTALL ATOP OF NEW ROOF CURBS AS INDICATED.ROOF AREAS B AND C:1. REMOVE THE EXISTING CLAY TILE ROOF SYSTEM DOWN TO THE EXISTING PLYWOOD ROOF DECK.INSTALL NEW STANDING SEAM METAL ROOF PANELS OVER NEW MEMBRANE UNDERLAYMENT ASINDICATED. REFER TO ROOF SYSTEM CROSS SECTION DETAIL 2/A501.2. PROVIDE THRU-WALL FLASHING AT THE ROOF TO WALL TRANSITION AS INDICATED.ROOF AREA AELEV. = 16'±TYP.21/4:12A502VTRTYP.F3A5024A501OF6A5014 1/2"4A502TYP.1A502TYP.2VTRA5021A5036A5025A5026A501OF4A5024A501ROOF AREA BMEAN ELEV. = 15'±5A5011675 LEE ROADWINTER PARK, FL 32789PH. (407) 740-6110| TERRACON.COMTERRACON FL LICENSE NO. 88305A50171'-1" ±5A5011ROOF PLANSCALE: 1/4" = 1'-0" 02'4'PLAN NORTH8'ENGR OF RECORDENGY MAGDY, P.E.ARCH/ENGR OF RECORDDESIGNED BYEMDRAWN BYWGISSUE DATE01/19/2026AE PROJECT NUMBERF9246313SHEET TITLEROOF PLANDRAWING NO.A101EXISTING ROOF SYSTEMEXISTING GRAVEL SURFACED ASPHALTBUILT-UP ROOFING, TO BE REMOVEDEXISTING PERLITE INSULATIONAT CRICKETS, TO BE REMOVEDEXISTING POLYISOCYANURATEINSULATION, TO BE REMOVEDEXISTING THICKNESSVARIES (0" TO 4")3" THICKEXISTING 1-1/2" DEEP WIDERIB METAL DECK, TO REMAIN2-PLY MODIFIED BITUMEN ROOF MEMBRANE:GRANULAR SURFACED CAP SHEET OVERSMOOTH BASE-PLY MEMBRANE(TORCH-APPLIED)1/2" THICK GYPSUM COVERBOARD(ADHESIVE ATTACHED)TOP LAYER OF POLYISOCYANURATEINSULATION (ADHESIVE ATTACHED)BASE LAYER OF POLYISOCYANURATEINSULATION (MECHANICALLY ATTACHED)EXISTING ROOF SYSTEMNEW ROOF SYSTEMEXISTING CLAY TILE ROOF, TO BE REMOVEDEXISTING UNDERLAYMENT, TO REMAINEXISTING PLYWOOD DECK, TO REMAIN.REPAIR DAMAGED OR DETERIORATEDDECK AS SPECIFIEDNOTE:1. ON EXISTING WOOD OR PLYWOOD SUBSTRATES, UTILIZE BASEFLASHING BASE-PLY MEMBRANE WITH SELF-ADHERING BOTTOMSURFACE AND TOP (SMOOTH) SURFACE TREATED SO AS TO RECEIVESUBSEQUENT LAYER OF TORCH-APPLIED CAP-PLY FLASHING. APPLYPRIMER TO SURFACES TO RECEIVE SELF-ADHERING MEMBRANE INACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.STANDING SEAM METAL ROOF PANELSSELF-ADHERED MEMBRANEUNDERLAYMENTEXISTING UNDERLAYMENTEXISTING PLYWOOD DECK. REPAIRDAMAGED OR DETERIORATED DECK ASSPECIFIED8"MIN.3"SEALANTTERMINATION BARMODIFIED BITUMENBASE FLASHINGLOW PROFILE FIBERCANT4" MIN.SECTION2" MIN.EXISTING WALL SUBSTRATE (SEE NOTE ABOVE)MODIFIED BITUMEN BASE FLASHING BASE PLY (EXTENDUP AND OVERTOP OF WALL AT PARAPET, TYP.)EXTEND ROOF MEMBRANE ABOVE HEAD OFCANT AND ADHERE TO WALLGRANULAR SURFACED MODIFIEDBITUMEN BASE FLASHING CAP PLY1675 LEE ROADWINTER PARK, FL 32789PH. (407) 740-6110| TERRACON.COMTERRACON FL LICENSE NO. 8830GRANULAR SURFACED MODIFIED BITUMENROOF MEMBRANE CAP SHEETMIN. POLYISO THICKNESSCOMBINED 4.5" THICK, TYP.16"STANDING SEAM METAL ROOF PANELSSELF-ADHERED MEMBRANEUNDERLAYMENTNEW ROOF SYSTEMEXISTING 1-1/2" DEEP WIDERIB METAL DECK1 ROOF SYSTEM CROSS SECTION - ROOF AREA ASCALE: N.T.S.(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)PLYWOOD AND WOOD SHIMS TOPROVIDE SLOPE AS SHOWN2X WOOD BLOCKING22" ±METAL COPING CAP. SEE 2/A503SELF-ADHERED MEMBRANE OVERTOPOF PARAPET, BENEATH COPING CAPNEW ROOF SYSTEM PROFILEEXISTING UNDERLAYMENTEXISTING PLYWOOD DECK. REPAIRDAMAGED OR DETERIORATED DECK ASSPECIFIED2ROOF SYSTEM CROSS SECTION - ROOF AREAS B AND CSCALE: N.T.S.(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)PLYWOOD AND WOOD SHIMS TOPROVIDE SLOPE AS SHOWN2X WOOD BLOCKING17" ±METAL COPING CAP. SEE 2/A503SELF-ADHERED MEMBRANEOVERTOP OF PARAPET,BENEATH COPING CAPMODIFIED BITUMEN ROOF MEMBRANE BASE PLYLOW PROFILE FIBER CANT STRIP, SET IN ADHESIVE ANDAPPLY PRIMER OVER FACE TO RECEIVE ROOFINGROOF INSULATION AND COVERBOARDEXISTING METAL DECK3TYPICAL MEMBRANE BASE FLASHINGSCALE: N.T.S.(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)5.5" ±EXISTING 2X WOODBLOCKINGEXISTING STUCCOEXISTING METALSTUD WALLEXISTING CMU WALL4PARAPET WALLSCALE: 3"=1'-0"0(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)4.5" ±5.5" ±4.5" ±EXISTING STUCCOEXISTING METALSTUD WALLEXISTING 2X WOODBLOCKINGCONTINUOUS SEALANTEXISTING STUCCOSURFACE MOUNTEDCOUNTERFLASHING WITHWIND CLIPSEXISTING METAL1/2" PLYWOODSTUD WALL22" ±SHEATHINGBASE FLASHING,SEE 3/A501EXISTING CMU WALLMODIFIED BITUMENROOFING SYSTEM,SEE 1/A501EXISTING METAL DECK3"6"9"5PARAPET WALLSCALE: 3"=1'-0"0(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)VARIES14" ± TO 22" ±1/2" PLYWOOD SHEATHINGEXISTING STUCCOSEAL AROUNDSCUPPER FACEPLATE, TYP.BASE FLASHING, SEE 3/A501MODIFIED BITUMENROOFING SYSTEM,SEE 1/A501BACKER ROD ANDSEALANT AROUNDSCUPPER SLEEVETHROUGH STUCCOMETAL SCUPPERASSEMBLY,SEE X/A50XEXISTING CMU WALL1/2" PLYWOOD SHEATHINGREINFORCED FLUID-APPLIEDFLASHING SYSTEM AROUNDSCUPPER OPENING, TYP.STRIP IN SCUPPER DECK FLANGEWITH MEMBRANE ROOFING6" NOM. WIDTH WOOD BLOCKING ATSCUPPERS TO PROVIDE NAILINGBASE FOR SCUPPER FLANGE, TYP.MODIFIED BITUMEN ROOFINGSYSTEM, SEE 1/A501EXISTING METAL DECKEXISTING STUCCOEXISTING METALSTUD WALLEXISTING METAL DECK3"6"9"6SECONDARY "OVERFLOW" THRU-WALL SCUPPERSCALE: 3"=1'-0"03"6"9"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)ENGR OF RECORDENGY MAGDY, P.E.ARCH/ENGR OF RECORDDESIGNED BYEMDRAWN BYWGISSUE DATE01/19/2026SHEET TITLEAE PROJECT NUMBERF9246313ROOF DETAILSDRAWING NO.A50124" ±CAST IRON DOME WITH STAINLESSSTEEL HARDWARECAST IRON CLAMPING RING WITH STAINLESSSTEEL HARDWAREEXTEND ROOFING PLIES INSIDE CLAMPING RING30" X 30" LEAD FLASHING SHEET SET IN MASTICMODIFIED BITUMEN STRIPPING PLY, EXTENDMIN. 4" BEYOND EDGE OF LEAD SHEET ANDADHERE TO BASE PLY MEMBRANE1/2:12 TAPERED INSULATIONSUMP (MIN.)ROOFING AND FLASHINGS AT ROOFDRAINMODIFIED BITUMEN ROOFING SYSTEM,SEE 1/A50112" MIN.2" MAX.PVC VENT PIPE EXTENSION, FIT INTO EXISTINGPIPE AND SET IN URETHANE SEALANTREINFORCED FLUID APPLIED FLASHING, EXTENDMIN. 3" UP BEYOND PIPE JOINTMODIFIED BITUMEN ROOFING SYSTEM, SEE 1/A50110" MIN.EXISTING GALVANIZED CURB ADAPTER (RE-USE),PAINT AS SPECIFIEDRE-SECURE EXISTING ROOFTOP EQUIPMENT TOROOF CURB WITH#14 HWH SCREWS WITH SEALINGWASHERS, 8" O.C. MAX. (MIN. 3 PER SIDE)24 GA. STAINLESS STEEL SKIRT WITH WIND CLIPSAT 24" O.C.INSULATED METAL CURBCANT STRIPMODIFIED BITUMEN BASE FLASHING, SEE 3/A501MODIFIED BITUMEN ROOFING SYSTEM, SEE 1/A5011675 LEE ROADWINTER PARK, FL 32789PH. (407) 740-6110| TERRACON.COMTERRACON FL LICENSE NO. 88301ROOF DRAINSCALE: 3"=1'-0"0(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING METAL DECKREMOVE AND REPLACE DRAININSULATION TO FACILITATE WORKCAST IRON DRAIN BOWL, JOSAM MODEL 21500OR APPROVED EQUAL, PROVIDE EXTENSIONAS SPECIFIED TO MATCH INSULATIONTHICKNESS WITHIN SUMP, WITH INTEGRALMETAL DRAIN RECEIVER/PAN AND NO-HUB ORINTERNALLY THREADED DRAIN OUTLETHEAVY DUTY DECK CLAMPNO-HUB COUPLING TO EXISTINGDRAIN LEADER PIPEEXISTING DRAIN LEADER PIPING3"6"9"EXISTING METAL DECKEXISTING VENT PIPE2VENT PIPESCALE: 3"=1'-0"03"6"9"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING STEEL DECKWOOD BLOCKING TO MATCHINSULATION THICKNESS3ROOFTOP EQUIPMENT CURBSCALE: 3"=1'-0"03"6"9"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)METAL ROOF SYSTEM, SEE 2/A501STRIP-IN ROOF EAVE FLASHING(FLANGE) WITH SELF-ADHEREDMEMBRANE PRIOR TO INSTALLINGROOF AT EDGESELF-ADHERED UNDERLAYMENT,EXTEND OVER ROOF EDGE ASSHOWNFIELD CUT, BEND RETURN IN PANELAND HOOK RETURN OVER EAVEFLASHINGMETAL EAVE FLASHING WITHCONTINUOUS CLEATEXISTING STUCCOMETAL ROOF SYSTEM, SEE 2/A501SELF-ADHERED UNDERLAYMENT,EXTEND OVER ROOF EDGE ASSHOWNGABLE FLASHINGTURN PANEL EDGE UPPOLYURETHANE FOAM CLOSURE,TYP."J" CLOSUREMETAL RAKE FLASHINGEXISTING STUCCOFIEW8L"/DMTVYAEPNR.UIFF.YPOP RIVET TO FLUSH LAP OFRIDGE/HIP FLASHINGRIDGE CAP FLASHINGTURN UP AND PROVIDE BOXEDPANEL ENDS, TYP.METAL ROOF SYSTEM, SEE 2/A501"Z" CLOSURE, SET IN TAPE SEALANTSELF-ADHERED UNDERLAYMENT4ROOF EDGESCALE: 3"=1'-0"03"6"9"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)5RAKE EDGESCALE: 3"=1'-0"03"6"9"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING PLYWOOD DECK6RIDGE/HIPSCALE: 3"=1'-0"03"6"9"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)ENGR OF RECORDENGY MAGDY, P.E.ARCH/ENGR OF RECORDDESIGNED BYEMDRAWN BYWGISSUE DATE01/19/2026SHEET TITLEAE PROJECT NUMBERF9246313ROOF DETAILSDRAWING NO.A502
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
BID 25-26-12 51ST YEAR CDBG D...
SOLICITATION DOCUMENTS: BID 25-26-12 51ST YEAR CDBG DRAINAGE IMPROVEMENTS EXHIBIT A - BID
City of Hanllandale Beach
Bid Due: 7/16/2026
Florida National Cemetery, Na...
Follow Florida National Cemetery, National Shrine Turfgrass Renovation Project Active Contract Opportunity Notice
VETERANS AFFAIRS, DEPARTMENT OF