Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06 Addendum 1
Project Information
- Bid Title
- Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06 Addendum 1
- Issuing Agency
- Liberty County School System
- Location
- Georgia
- Published Date
- Dec 11, 2025
- Closing Date
- Jan 6, 2026
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06Title:Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06Description:The Liberty County School System (the “LCSS” or the “District”) wishes to announce that we are requesting Statements of Proposals to Upgrade the HVAC System at Frank Long Elementary School RFP 2026-06, by a firm authorized to do business in the State of Georgia. The advertising dates for this RFP 2026-06 are November 24, 2025 through January 6, 2026. Statements of Proposals will be accepted prior to 11:00 A.M. on January 6, 2026. A mandatory Pre-Proposal
Conference will be held on December 3, 2025 at 11:00 A.M., at Frank Long Elementary School in the Media Center, located at 920 Long Frasier Drive, Hinesville, Georgia 31313.Start Date:
11/24/2025
Contact Name:ArnoldContact Phone:JacksonContact Email:Contact Address:
200 Bradwell St
Contact City:
Hinesville
Contact State:
Ga
Contact Zip:
31313
Files:- 2026-06 - Addendum _1 (7.67 MB)
- 2026-06 Bid Requirements (269 KB)
- 2026-06 Drawings (6.25 MB)
- 2026-06 Invitation to Bid (146 KB)
- 2026-06 Project Manual (2.38 MB)
- Attachment Preview
-
FLE HVAC UpgradesRFP 2026-06RFP ADDENDUM #1Page 1 of 1RFP ADDENDUM #1Date of Addendum: December 10, 2025NOTICE TO ALL POTENTIAL RESPONDENTSThe Request for Proposals (RFP) is modified as set forth in this Addendum. The original RFP Documentsand any previously issued addenda remain in full force and effect, except as modified by this Addendum,which is hereby made part of the RFP. Respondent shall take this Addendum into consideration whenpreparing and submitting its Proposal.PROPOSAL SUBMITTAL DEADLINEThe Proposal submittal deadline remains the same and is not changed by thisAddendum.QUESTIONS AND ANSWERS1. Question: PTAC units will not be replaced at this time. How does this affect thebipolar ionization device and ventilation rates?a. Bipolar isolation devices will not be provided for each classroom. This willbe done in the future replacement of PTAC units.2. Question: Shall the contractor be responsible for providing restrooms forconstruction personnel?a. Temporary restroom facilities (portable toilets) for construction personnelshall be provided, maintained, and removed by the contractor. Locationsshall be coordinated with owner prior to project start. Owner-furnished ofexisting restrooms shall not be used unless specifically approved in writing.3. Question: Existing roof hatch is installed backwards. Will this be addressed in newwork?a. Roof hatch shall be rotated to open away from the access ladder.4. The Pre-bid Sign-in sheet is attached to this addendum.END OF ADDENDUMELECTRICAL ABBREVIATIONS LIST1P1 POLE (2P, 3P, 4P, ETC.)A, AMP AMPEREACABOVE COUNTERACLG ABOVE CEILINGADO AUTOMATIC DOOR OPENERAFAMP FRAMEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT CIRCUITINTERRUPTERAHU AIR HANDLING UNITALALUMINUMALT ALTERNATEAMP AMPEREAMPL AMPLIFIERANNUN ANNUNCIATORAPPROX APPROXIMATELYAQ-STAT AQUASTATARCH ARCHITECT, ARCHITECTURALASAMP SWITCHATAMP TRIPATS AUTOMATIC TRANSFER SWITCHAUTO AUTOMATICAUX AUXILIARYAVAUDIO VISUALAWG AMERICAN WIRE GAUGEBATT BATTERYBDBOARDBLDG BUILDINGBMS BUILDING MANAGEMENT SYSTEMCCONDUITCAB CABINETCAT CATALOGCATV CABLE TELEVISIONCBCIRCUIT BREAKERCCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCLG CEILINGCOMB COMBINATIONCMPR COMPRESSORCONN CONNECTIONCONST CONSTRUCTIONCONT CONTINUATION OR CONTINUOUSCONTR CONTRACTORCONV CONVECTORCPCIRCULATING PUMPCRT CATHODE-RAY TUBECTCURRENT TRANSFORMERCTR CENTERCUCOPPERDCP DOMESTIC WATER CIRCULATING PUMPDEPT DEPARTMENTDET DETAILDIA DIAMETERDISC DISCONNECTDIST DISTRIBUTIONDNDOWNDPR DAMPERDSSAFETY DISCONNECT SWITCHDTDOUBLE THROWDWG DRAWINGECELECTRICAL CONTRACTORELEC ELECTRIC, ELECTRICALELEV ELEVATORELU EMERGENCY LIGHTING UNITEM EMERGENCYEMS ENERGY MANAGEMENT SYSTEMEMT ELECTRICAL METALLIC TUBINGEPELECTRIC PNEUMATICEQUIP EQUIPMENTEWC ELECTRIC WATER COOLEREXIST EXISTINGEXH EXHAUSTEXP EXPLOSION PROOFFAFIRE ALARMFABP FIRE ALARM BOOSTER POWERSUPPLY PANELFACP FIRE ALARM CONTROL PANELFCU FAN COIL UNITFIXT FIXTUREFLR FLOORFLUOR FLUORESCENTFUFUSEFUDS FUSED SAFETY DISCONNECT SWITCHGA GAUGEGAL GALLONGALV GALVANIZEDGC GENERAL CONTRACTORGEN GENERATORGFI GROUND FAULT CIRCUIT INTERRUPTERGFP GROUND FAULT PROTECTORGND GROUNDGRS GALVANIZED RIGID STEEL (CONDUIT)GYP BD GYPSUM BOARDHOA HANDS-OFF-AUTOMATIC SWITCHHORIZ HORIZONTALHPHORSEPOWERHPF HIGH POWER FACTORHTHEIGHTHTG HEATINGHTR HEATERHVHIGH VOLTAGEHVAC HEATING, VENTILATING AND AIRCONDITIONINGICINTERRUPTING CAPACITYIGISOLATED GROUNDIMC INTERMEDIATE METAL CONDUITINCAND INCANDESCENTIRINFRAREDI/W INTERLOCK WITHJ-BOX JUNCTION BOXKVKILOVOLTKVA KILOVOLT-AMPEREKVAR KILOVOLT-AMPERE REACTIVEKW KILOWATTKWH KILOWATT HOURLOC LOCATE OR LOCATIONLTLIGHTLTG LIGHTINGLTNG LIGHTNINGLVLOW VOLTAGEMAX MAXIMUMMAG.S MAGNETIC STARTERM/C MOMENTARY CONTACTMC MECHANICAL CONTRACTORMCB MAIN CIRCUIT BREAKERMCC MOTOR CONTROL CENTERMDC MAIN DISTRIBUTION CENTERMDP MAIN DISTRIBUTION PANELMFR MANUFACTURERMFS MAIN FUSED DISCONNECT SWMH MANHOLEMIC MICROPHONEMIN MINIMUMMISC MISCELLANEOUSMLO MAIN LUGS ONLYMMS MANUAL MOTOR STARTERMOA MULTIOUTLET ASSEMBLYMSP MOTOR STARTER PANELBOARDMSBD MAIN SWITCHBOARDMT MOUNTMT.C EMPTY CONDUITMTS MANUAL TRANSFER SWITCHMTR MOTOR, MOTORIZEDN.C. NORMALLY CLOSEDNEC NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICALMANUFACTURER'S ASSOCIATIONNFDS NON-FUSED SAFETY DISCONNECTSWITCHNIC NOT IN CONTRACTNLNIGHT LIGHTN.O. NORMALLY OPENNPF NORMAL POWER FACTORNTS NOT TO SCALEOH OVERHEADOLOVERLOADSPAPUBLIC ADDRESSPBPULL BOX OR PUSHBUTTONPEPNEUMATIC ELECTRICPED PEDESTALPFPOWER FACTORPHPHASEPIV POST INDICATING VALVEPNL PANELPPPOWER POLEPRPAIRPRI PRIMARYPROJ PROJECTIONPRV POWER ROOF VENTILATORPTPOTENTIAL TRANSFORMERPVC POLYVINYL CHLORIDE (CONDUIT)PWR POWERQUAN QUANTITYRCPT RECEPTACLEREQD REQUIREDRM ROOMRSC RIGID STEEL CONDUITRTU ROOF TOP UNITSABC SMALL APPLICANCE BRANCHCIRCUITSCSURFACE CONDUITSEC SECONDARYSHT SHEETSIM SIMILARS/N SOLID NEUTRALSPEC SPECIFICATIONSPKR SPEAKERSPSPARESPD SURGE PROTECTION DEVICESRSURFACE RACEWAYSSSTAINLESS STEELSSW SELECTOR SWITCHS/S STOP/START PUSHBUTTONSSTA STATIONSTD STANDARDSURF SURFACE MOUNTEDSW SWITCHSWBD SWITCHBOARDSYM SYMMETRICALSYS SYSTEMTEL TELEPHONETEL/DATA TELEPHONE/DATATERM TERMINALTLTWIST LOCKTRTAMPER RESISTANTT-STAT THERMOSTATTTC TELEPHONE TERMINAL CABINETTVTELEVISIONTVTC TELEVISION TERMINAL CABINETTYP TYPICALUC UNDER COUNTERUEUNDERGROUND ELECTRICALUG UNDERGROUNDUH UNIT HEATERUNO UNLESS NOTED OTHERWISEUTUNDERGROUND TELEPHONEUTIL UTILITYUVULTRAVIOLETVVOLTVAVOLT-AMPERESVDT VIDEO DISPLAY TERMINALVERT VERTICALVFD VARIABLE FREQUENCY DRIVEVOL VOLUMEWWATTW/WITHWG WIRE GUARDWH WATER HEATERW/O WITHOUTWP WEATHERPROOFXFMR TRANSFORMERXFR TRANSFER∠ ANGLE@ AT▲ DELTA' FEET" INCHES# NUMBERØ PHASEC CENTER LINEP PLATEELECTRICAL SYMBOL LEGENDLIGHTING SYMBOLSPOWER SYMBOLSTELECOM SYMBOLSLIGHTING FIXTURES, TYPICAL, RECTANGULAR(VARIOUS SYMBOLS)FILLED CIRCLES INDICATE RECESSED,OPEN CIRCLES INDICATE SURFACE-MOUNTEDDIAGONAL LINE INDICATES LENSEDOUTER DOTS INDICATE SUSPENDEDSIMPLEX RECEPTACLEDUPLEX RECEPTACLELIGHTING FIXTURES, TYPICAL, ROUNDCENTER DOT INDICATES PENDANTDIAGONAL LINE INDICATES LENSEDCHEVRON INDICATES WALL WASHWALL-MOUNTED FIXTURES, TYPICALSTRIP FIXTUREDIRECTIONAL LIGHT, TRACK, FLOODLINEAR LIGHT, TAPE LIGHTEMERGENCY LIGHTING UNIT, CEILING-MOUNTED,INTEGRAL BATTERYEMERGENCY LIGHTING UNIT, CEILING-MOUNTED, REMOTE BATTERYEMERGENCY LIGHTING UNIT, WALL-MOUNTED, INTEGRAL BATTERYEMERGENCY LIGHTING UNIT, WALL-MOUNTED, REMOTE BATTERYEXIT LIGHT, CEILING-MOUNTED, SHADINGAND ARROWS INDICATE FACES ANDDIRECTIONEXIT LIGHT, WALL-MOUNTED, SHADINGAND ARROWS INDICATE FACES ANDDIRECTIONEXIT/ELU COMBOPOLE/AREA LIGHTSPOST-TOP AREA LIGHTBOLLARD LIGHTDIAGONAL HATCH INDICATESEMERGENCY LIGHTOSVSOS DVS DOSVSOSTCSINGLE POLE SWITCH3-WAY SWITCH4-WAY SWITCHKEYED SWITCHLOW VOLTAGE MOMENTARY PUSHBUTTON ORDECORATOR SWITCHSWITCH W/PILOTDIMMER SWITCHFAN SPEED CONTROLLER. COORDINATE TYPEWITH FAN MANUFACTURER.OCCUPANCY SENSOR W/ MANUAL SWITCHVACANCY SENSOR W/ MANUAL SWITCHOCCUPANCY SENSOR W/ 0-10V DIMMERVACANCY SENSOR W/ 0-10V DIMMEROCCUPANCY SENSOR, CEILING MOUNTEDVACANCY SENSOR, CEILING MOUNTEDCORRIDOR OCCUPANCY SENSOR, CEILINGMOUNTEDTIMER SWITCHTIME DELAY SWITCHTIME CONTROL SWITCHLIGHTING TAGSTOP VALUE: FIXTURE TYPE IDS3dBOTTOM VALUE: LOWERCASE LETTER: SWITCH IDBOTTOM VALUE: NUMBER(S): CIRCUIT NUMBERABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THEONLY SWITCH IN THE SPACE. AN "nl" IN PLACE OF THE SWITCH IDINDICATES NIGHT LIGHT (UNSWITCHED).SWITCH ID INDICATED BY A LOWERCASE LETTER. SWITCHIDS ARE UNIQUE PER SPACE. A SWITCH WITH AN ID "a"CONTROLS ALL DEVICES WITHIN THE SPACE IN WHICH ITIS LOCATED TAGGED WITH "a". A SWITCH WITHOUT ATAGGED ID CONTROLS ALL LIGHTING FIXTURES WITHIN ASPACE. ID TAGS MAY BE USED ON CONTROL DEVICESOTHER THAN SWITCHES, SUCH AS OCCUPANCY SENSORSOR CONTACTORS.QUADRUPLEX RECEPTACLESPECIAL RECEPTACLE, TYPE AS INDICATEDJ J J JUNCTION BOXRECEPTACLE MODIFIERS:##": HEIGHT AFF OCAC: ABOVE COUNTERWP: WEATHERPROOF IN-USE COVERW/ WR RATED GFI RECEPTACLEWPD: WEATHERPROOF NOT-IN-USE COVERW/ WR RATED GFI RECEPTACLEIG: ISOLATED GROUNDCENTER SHADING INDICATES GFIHALF SHADING INDICATES SPLIT(TYPICALLY SWITCHED)OUTER SHADING INDICATES EMERGENCYMULTIOUTLET ASSEMBLY,FILLED SQUARES INDICATED 120V OUTLETSRANGE RECEPTACLE, NEMA 14-50RCORD REEL, DEVICE VARIESDROP CORD, DEVICE VARIESFLOORBOX, TYPE AS INDICATEDPOKE THRU DEVICE, TYPE AS INDICATEDEPOEMERGENCY POWER OFF SWITCHMETERSAFETY SWITCH, NON-FUSEDSAFETY SWITCH, FUSEDMOTOR STARTERCOMBINATION STARTER/DISCONNECTPUSHBUTTONMOTORGROUND BARPOWER DEVICE AND EQUIPMENT TAGSd ELECTRICAL DEVICE TAGS: THE CIRCUIT DESIGNATION ISINDICATED BY A NUMBER. THE SWITCH DESIGNATION ISINDICATED BY A LOWER CASE LETTER (WHERE APPLICABLE).EXAMPLE: SPLIT DUPLEX RECEPTACLE IS CONNECTED TOCIRCUIT 1 AND ONE RECEPTACLE OUTLET IS CONTROLLED BYSWITCH "d".EQUIPMENT TAGS: EQUIPMENT ID IS INDICATED BY ANUNDERLINED TAG ADJACENT TO THE EQUIPMENT. SEE THEEQUIPMENT CONNECTION SCHEDULE FOR DESCRIPTION,XX-1 ELECTRICAL REQUIREMENTS, AND PANEL AND CIRCUIT NUMBER.SYMBOLS/GRAPHIC APPEARANCE OF EQUIPMENT VARIES.POWER DISTRIBUTION EQUIPMENTMDP HP1A LP1ASB1HATCHED FILL INDICATES DISTRIBUTION PANEL ORSWITCHBOARD.SOLID FILL INDICATES BRANCH PANEL OR LOAD CENTER.DASHED BOX INDICATES CODE-REQUIRED CLEARANCE (WIDTHAND DEPTH). DOOR INDICATES FRONT OF RECESSED PANEL.T1 TRANSFORMER: TYPICALLY TRANSFORMER NAMES BEGIN WITHOR CONTAIN THE LETTER "T". SEE SINGLE-LINE DIAGRAM FORDESCRIPTION AND REQUIREMENTS.WIRINGCONDUIT SHOWN WITHOUT SLASH MARKS SHALLCONTAIN 1 # 12 CONDUCTOR PER PHASE, NEUTRAL, ANDGROUND IN 1/2" CONDUIT UNLESS SPECIFIC EQUIPMENTREQUIRES A DIFFERENT SIZE.#10P4N-1021, 3, 5CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTORPER PHASE IN ELECTRICAL CODE SIZED MINIMUMCONDUIT UNLESS A CONDUCTOR AND CONDUIT SIZE ISSHOWN ADJACENT.HOME RUN TO BRANCH CIRCUIT PANELBOARD. THEPANELBOARD DESIGNATION IS SHOWN ADJACENT TOTHE HOME RUN ARROW AS A NUMERATOR AND THECIRCUIT DESIGNATION IS SHOWN AS THE DENOMINATOR.CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARESHOWN IN THE PANELBOARD SCHEDULE WITH THECORRESPONDING PANELBOARD AND CIRCUITDESIGNATION. EXAMPLE: HOME RUN TO PANELBOARDP4N-102; CIRCUITS 1, 3, 5. LONG TICKMARKS INDICATENUMBER OF PHASE CONDUCTORS. SHORT TICK MARKSINDICATE NUMBER OF GROUNDED CONDUCTORS(NEUTRALS). AN EQUIPMENT GROUNDING CONDUCTORIS NOT INDICATED BUT SHALL BE INSTALLED. NUMBEROF ARROWHEADS INDICATE NUMBER OF CIRCUITS.CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BYFIELD CONDITIONSCONDUIT IN FLOORDATA OUTLETVOICE OUTLETDATA/VOICE OUTLETWIRELESS ACCESS POINTCATV OUTLETSECURITY SYMBOLSWALL MOUNTED SECURITY CAMERACEILING MOUNTED SECURITY CAMERACRCARD READERCKCARD READER W/ KEYPADDCDOOR CONTACTESELECTRIC STRIKEMLMAGNETIC LOCKCOMBINATION LOCKREQUEST TO EXIT BUTTONMDMOTION DETECTORSECURITY SYSTEM KEYPADSOUND SYSTEM SYMBOLSWALL MOUNTED SPEAKERSCEILING MOUNTED SPEAKERVVOLUME CONTROLCONSTRUCTION PHASING(TYPICAL ALL SYMBOLS AND EQUIPMENT)(E)EXISTING TO REMAINEXISTING TO BE REMOVEDNEWEXISTING TO BE DEMOLISHEDMISCELLANEOUSAREA NOT IN CONTRACT1KEY NOTE (SEE SCHEDULE)-NUMBER OF DETAIL ON SHEET---NUMBER OF SHEET WHERE DETAIL APPEARS1Room6REVISION NUMBER - SHOWN ON PLANSROOM NAME AND NUMBERSHEETE000E101E201E202E301E302E303E304E401ELECTRICAL SHEET INDEXDESCRIPTIONELECTRICAL TITLE SHEETCOMPOSITE ELECTRICAL DEMOLITION PLANCOMPOSITE POWER PLANCOMPOSITE ROOF POWER PLANENLARGED POWER PLAN - ADMIN, MEDIA, & CAFEENLARGED POWER PLAN - GYM & WING AENLARGED POWER PLAN - WING B & CENLARGED POWER PLAN - WING D & EELECTRICAL EQUIPMENT SCHEDULESELECTRICAL GENERAL NOTESA THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BEUSED IN THIS SET OF DRAWINGS.B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS SHALLBE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE SPACESOR INSTALLED WHERE EXPOSED AND SUBJECT TO PHYSICAL DAMAGE. LOWVOLTAGE CABLES MAY BE RUN IN CABLE TRAY. LOW VOLTAGE CABLES MAY BE RUN INCABLE SUPPORT HOOKS ABOVE ACCESSIBLE CEILINGS. LOW VOLTAGE CABLES SHALLBE PLENUM RATED IN PLENUM SPACES.C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS ANDDETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVERLOCATIONS SHOWN ON ELECTRICAL DRAWINGS.D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITINGSHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA. PROVIDEDEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING ,UNLESS NOTEDOTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER CONDUCTORS INCLUDINGEQUIPMENT GROUNDING CONDUCTORS PROPORTIONALLY FOR NO MORE THAN 3%VOLTAGE DROP ON BRANCH CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION OFELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TOMAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS ABOVEACCESSIBLE CEILINGS.F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF EQUIPMENT.CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS WITHEQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO ROUGH-IN AND AT NOADDITIONAL COST TO THE OWNER.G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS, EMPTYCARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS SPAREEQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURINGCONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGNMATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.H CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE THESTRUCTURE SHALL BE PVC.I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOODWORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION(NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE NATIONALELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND ORDINANCES.J FIELD COORDINATE FINAL MECHANICAL AND PLUMBING EQUIPMENT LOCATIONSALONG WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TOROUGH-IN. ADJUST CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCHCIRCUITING ACCORDINGLY. PROVIDE ADDITIONAL BRANCH CIRCUITS FROM SPARECIRCUIT BREAKERS TO ACCOMMODATE ANY CONTROL PANELS AND ACCESSORIESREQUIRING POWER.K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A LICENSEDMASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEESASSOCIATED WITH THIS WORK.L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTINGLABORATORY UNO.M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING APPROVEDSUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT SUPPLIED,ANDMANUFACTURER'S OPERATION AND MAINTENANCE INSTRUCTIONS.N THE CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL WIRING TERMINATIONS TOPRE-INSTALLED RECEPTACLES IN OFFICE FURNITURE. CONTRACTOR IS RESPONSIBLEFOR WIRING AND INSTALLING VOICE/DATA DEVICES IN OFFICE FURNITURE.COORDINATE PLACEMENT OF DEVICES WITH FURNITURE LAY-OUT.O SECURITY SYSTEM TO BE PROVIDED UNDER SEPARATE CONTRACT. IT IS THERESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE CONDUIT PROVISIONS, BACKBOXES, ROUGH-INS, SLEEVES AND POWER TO HEAD END EQUIPMENT FOR EXACTREQUIREMENTS PRIOR TO START OF WORK.P CONDUIT AND WIRE SHALL NOT BE INSTALLED BELOW FLOOR SLAB UNLESSINDICATED ON PLAN BY DASHED CONDUIT.Q CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN ONDRAWINGS EXCEPT FOR ITEMS LISTED BELOW. THESE ITEMS SHALL CONSIST OF ABACK BOX WITH CONDUIT STUBBED ABOVE THE ACCESSIBLE CEILING, SEE STUB UPDETAIL. VERIFY SIZE OF BACK BOX REQUIRED WITH DEVICE TO BE INSTALLED.LOCATE BACK BOXES 6" FROM ADJACENT POWER RECEPTACLE INTENDED FORCOMPUTER USE.- TV OUTLETS- VOLUME CONTROLS- TELEPHONE OUTLETS- DATA OUTLETS- FIRE ALARM DEVICESR FURNISH AND INSTALL CONDUIT FROM BACK BOXES FOR THE FOLLOWING DEVICESINTO THE ACCESSIBLE CEILING SPACE IN THE CORRIDOR, UNLESS NOTEDOTHERWISE:- 1"C TV OUTLETS- 1/2"C VOLUME CONTROLS- 3/4"C DOOR SECURITY DEVICES (CARD READERS, DOOR STRIKES ETC.)- 1"C TELEPHONE OUTLETS- 1"C DATA OUTLETS- 3/4"C FIRE ALARM DEVICESELECTRICAL REMODEL NOTESA BRANCH CIRCUITING INDICATED ON PLANS AND SCHEDULES IS BASED UPON EXISTINGPLANS AND SITE OBSERVATION, CONTRACTOR TO FIELD VERIFY.B PROVIDE TYPED CIRCUIT BOARD DIRECTORIES TO REFLECT AS-CONSTRUCTEDCONDITIONS. FIELD VERIFY DURING CONSTRUCTION AND REVISE ACCORDINGLY.C PROVIDE NECESSARY DEMOLITION TO FACILITATE NEW CONSTRUCTION WORKASSOCIATED WITH THIS PROJECT. COORDINATE OUTAGES WITH OWNER MINIMUM 72HOURS IN ADVANCE. OWNER RETAINS RIGHT TO FIRST SALVAGE. PROVIDE DISPOSALOF REMOVED MATERIAL. MAINTAIN CIRCUIT CONTINUITY AS REQUIRED.D IT IS THE INTENT OF THESE DIAGRAMMATIC DRAWINGS TO PROVIDE THE PROJECTSCOPE INCLUDING, BUT NOT LIMITED TO PHASED DEMOLITION AND NEWCONSTRUCTION. EXISTING INFORMATION INDICATED ON THESE PLANS DOES NOTREPRESENT ALL EXISTING CONDITIONS. THIS CONTRACTOR SHALL BECOME FAMILIARWITH EXISTING CONDITIONS, SCOPE OF PHASING, AND PROJECT INTENT PRIOR TO BIDSUBMISSION.E PROVIDE CUTTING, PATCHING, AND RESTORATION OF FINISHES NECESSARY FORWORK SURFACES DAMAGED BY THIS WORK. SPACES AROUND CONDUITS PASSINGTHROUGH FLOORS AND WALLS SHALL BE NEATLY PATCHED AND FINISHED TO MATCHNEW/EXISTING. STRUCTURAL MEMBERS SHALL NOT BE CUT OR PENETRATED IN ANYMANNER. THE SPACES AROUND THE CONDUITS SHALL BE SEALED TO PREVENTENTRANCE OF MOISTURE. PROVIDE FIRE STOPPING PER UL APPROVED METHODS.F REMOVE ABANDONED WIRING COMPLETE. AT CONTRACTORS OPTION, UTILIZEEXISTING ABANDONED RACEWAY TO EXTENT AVAILABLE. EXPOSED ABANDONEDRACEWAY SHALL BE REMOVED.No.G COORDINATE WORK IN PHASES WITH GENERAL CONTRACTOR AND OWNER TOFACILITATE DEMOLITION AND NEW CONSTRUCTION.H REMOVE ELECTRICAL RELATED EQUIPMENT (I.E JUNCTION BOXES, RECEPTACLES,SWITCHES, DEVICES, ETC... ) AFFECTED/ABANDONED AS A RESULT OF DEMOLITIONAND NEW CONSTRUCTION.1020 Drayton St., Suite 101Savannah, GA 31401(912) 963-1611www.MethodEG.comEOREGIRGSTEREDINo. PE041545PROFESSIONAL11/21/25TOENGINEERPHER G.SHRevision ScheduleDescriptionDateELECTRICALTITLE SHEETProject numberDateDrawn byChecked by2123NOVEMBER 2025ELPCGSE000DEMOLITION SHEET NOTESA SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR PHASES OFDEMOLITION AND CONSTRUCTION. COORDINATE WITH GENERAL CONSTRUCTION.B DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES AND LIGHTING FIXTURES INDEMOLITION AREAS UNLESS NOTED OTHERWISE.C DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES IN WALLS TO BEDEMOLISHED. WALLS TO BE DEMOLISHED ARE SHOWN DASHED. DISCONNECTAND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO LAST REMAINING DEVICE.FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OFCIRCUIT(S) TO ANY EXISTING DEVICES TO REMAIN. COORDINATE AND VERIFYREQUIREMENTS WITH NEW WORK IN AREA.D FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR CONTINUITY OFANY FEEDERS OR BRANCH CIRCUITS ORIGINATING OUTSIDE THE DEMOLITIONAREA THAT SERVES ANY ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTERDEMOLITION. MODIFY OR REPLACE AS REQUIRED.E FURNISH AND INSTALL CONDUIT AND/OR COMMUNICATIONS/DATA WIRING ASNECESSARY FOR CONTINUITY OF ANY WIRING ORIGINATING OUTSIDE THEDEMOLITION AREA THAT SERVES ANY COMMUNICATIONS/DATA EQUIPMENT ORDEVICES TO REMAIN AFTER DEMOLITION. MODIFY OR REPLACE AS REQUIRED.F DISCONNECT AND REMOVE LIGHT SWITCHES IN DEMOLITION AREAS ASNECESSARY TO ACCOMMODATE NEW DOOR CONFIGURATIONS.G DISCONNECT AND REMOVE ANY EXISTING ELECTRICAL DEVICES AND BACK BOXESAS NECESSARY WHERE NEW WALL CONSTRUCTION WILL INTERSECT AN EXISTINGWALL. FURNISH AND INSTALL CONDUIT AND WIRE AS REQUIRED FOR CONTINUITYOF CIRCUIT(S).H FURNISH AND INSTALL BLANK COVER PLATES OVER ALL EXISTING UNUSEDOPENINGS.1020 Drayton St., Suite 101Savannah, GA 31401(912) 963-1611www.MethodEG.comWING AWING BWING CWING DSTORAGE SHED001CLASSROOM512CLASSROOM511GYMNASIUMEXISTING AIR HANDLINGUNIT BEING DEMOLISHED.CCLLAASSSSRROOOOMM551133CLASSROOM510(E)AHU-3STORAGE622BOYS TOILET621JANITORGYM620617GIRLS TOILET619OFFICE618ELECT612(E)LPF(E)BOOK STORAGE613HPF(E)GIRLS TOILET614JANITOR615Space002BOYS TOILET616CORRIDOR601CLASSROOM611CLASSROOM610CLASSROOM609CLASSROOM514CORRIDOR501CLASSROOM509CLASSROOM515CLASSROOM508CLASSROOM516BOOK STORAGE517MECHANICAL502VESTIBULE506JANITOR507VESTIBULE503BOYS TOILET505GIRLS TOILET504EXISTING ERU BEINGDEMOLISHED.(E)ERU-4BOOK STORAGE606 CORRIDORHPC (E)(E)(E)LPCART607KILN608605CONFERENCE(E)LPC1604(E)HPDBOOK STORAGE(E)603(E)AV STORAGE151ELECTRICAL602MEDIA DISTRIBUTION150CLASSROOM412CLASSROOM413CLASSROOM411CLASSROOM410CLASSROOM312CLASSROOM313CLASSROOM311CLASSROOM310CLASSROOM212CLASSROOM213CLASSROOM211CLASSROOM210WING ECLASSROOM807CLASSROOM806CLASSROOM414CORRIDOR401CLASSROOM409CLASSROOM415CLASSROOM408CLASSROOM314CORRIDOR301CLASSROOM309CLASSROOM315CLASSROOM308CLASSROOM214CORRIDOR201CLASSROOM209CLASSROOM215CLASSROOM208CLASSROOM808CLASSROOM805CLASSROOM809CORRIDOR801CLASSROOM804CLASSROOM416VESTIBULE406JANITOR407BOYS TOILET405VESTIBULE403GIRLS TOILET404CLASSROOM316(E)ERU-3MECHANICAL402EXISTING ERU BEINGDEMOLISHED.FACULTY DINING124CORRIDOR125(E)AHU-2OFFICE144RESOURCE142MENS TOILET127MB(E)MECHANICAL126WORK ROOM145MEDIACENTERWOMENS TOILET141PASSAGE128SUPPLY140TOILET131VESTIBULE152EXISTING AIR HANDLINGUNITS BEING DEMOLISHED.CAFETERIATOILET139MEDIA PRODUCTION146(E)GF-1CLINIC137VICE PRINCIPAL136VAULT135PRINCIPAL129OFFICE132CONFERENCE133RECEPTION134OFFICE102LOBBY101VESTIBULE306VESTIBULE206BOYS TOILET205JANITOR307VESTIBULE303MECHANICAL302CORRIDOR317(E)ERU-2CLASSROOM216JANITOR207VESTIBULE203GIRLS TOILET204EXISTING ERU BEINGDEMOLISHED.(E)ERU-1MECHANICAL202EXISTING ERU BEINGDEMOLISHED.CLASSROOM810CLASSROOM803EXISTING ERU BEINGDEMOLISHED.SPED CONFERENCE (E)ERU-5811MECHANICAL802CORRIDOR (E)AHU-1125ELECTRICAL118CORRIDOR123JANITOR116BOOK STORAGE115TOILET114(E) LPB(E)HPB(E)LPA(E)(E)HPAMECHANICAL117MSB(E)HPK(E)HPK1(E)(E)LPK (E)LPK1(E)CONFERENCE120BOOK STORAGE119CONFERENCE121DISH RETURN105FREEZER00EMPLOYEE LOCKER113COOLER00SERVING107JANITOR111MADRY STORAGE (E)112KITCHENCAN WASH110SERVING104DISH WASH106(E)(E)OFFICE109(E)(E)EXISTING CEILINGRECESSED UNITVENTILATORSBEING DEMOLISHED.EXISTING AIRHANDLING UNIT,PUMPS AND BOILERBEING DEMOLISHED.EXISTING CHILLERBEING DEMOLISHED.CONFERENCE122BOOK ROOM703SPED CONFERENCE702ELECT704CLASSROOM705(E) HN1(E) HNLN1(E)LN(E)(E)CORRIDOR701VEST. JANITOR VEST.G02 707 G05BOYS TOILET706GIRLS TOILET708CLASSROOM709(E)CU-5EXISTING SPLITERU CONDENSINGUNIT BEINGDEMOLISHED.CONFERENCE148EXISTING CEILINGRECESSED UNITVENTILATORSBEING DEMOLISHED.1 COMPOSITE ELECTRICAL DEMOLITION PLANE101 1" = 20'-0"ABCDEGYMADMIN/MEDIA/CAF/KITCHENKEY PLANEOREGIRSTEGREDINo. PE041545PROFESSIONAL11/21/25TOENGINEERPHER G.SHRevision ScheduleNo.DescriptionDateCOMPOSITEELECTRICALDEMOLITIONPLANProject numberDateDrawn byChecked by2123NOVEMBER 2025ELPCGSE101POWER SHEET NOTESA WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN INDIVIDUALRECEPTACLE (SIMPLEX OR DUPLEX), THE RECEPTACLE SHALL BE RATED AT 20A.B CIRCUIT WIRING IS NOT SHOWN, PROVIDE PROPER NUMBER OF CONDUCTORS TOACHIEVE CIRCUITING AND SWITCHING SHOWN.C CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEEPANELBOARD SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TOTHE CIRCUIT BREAKER RATING, UNLESS INDICATED OTHERWISE ON THEELECTRICAL EQUIPMENT SCHEDULE.D PROVIDE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED AND GRADE MOUNTEDELECTRICAL EQUIPMENT. MINIMUM REQUIREMENTS: 4" HIGH, 4% AIR ENTRAINED,POLYFIBER REINFORCED CONCRETE, 4" WIDER AND 4" LONGER THAN EQUIPMENTTO BE PLACED ON IT. REFER TO ELECTRICAL DETAIL DRAWINGS FORTRANSFORMER, GENERATOR, OR SWITCHGEAR PADS THAT MAY EXCEED THESEREQUIREMENTS.1020 Drayton St., Suite 101Savannah, GA 31401(912) 963-1611www.MethodEG.comWING ACLASSROOM512CLASSROOM511GYMNASIUMGYM617HP-3-1WPHP-3-2AH-3-1HTAH-3-2DH-3MC1STORAGE622BOYS TOILET621JANITOR620GIRLS TOILET619OFFICE618(E)LPF BOOK STORAGE(E)613HPF(E)GIRLS TOILET614JANITOR615Space002BOYS TOILET616CORRIDOR601ARTCLASSROOMCLASSROOMCLASSROOM607611610609CLASSROOM513CLASSROOM510CLASSROOM514CORRIDOR501CLASSROOM509CLASSROOM515CLASSROOM508CLASSROOM516BOOK STORAGE517VESTIBULE506JANITOR507BOYS TOILET505VESTIBULE503GIRLS TOILET504MECHANICAL502DOAS-1CORRIDOR501THBOOK STORAGE606CORRIDOR605KILN608(E)HPC (E)(E)(E) LPCCONFERENCE604(E)LPC1(E)HPDBOOK STORAGE(E)AV STORAGE151603 LPD (E)ELECTRICAL602WING BCLASSROOM412CLASSROOM413CLASSROOM411CLASSROOM410WING CCLASSROOM312CLASSROOM313CLASSROOM311CLASSROOM310WING DCLASSROOM212CLASSROOM213CLASSROOM211CLASSROOM210STORAGE SHED001WING ECLASSROOM807CLASSROOM806CLASSROOM414CORRIDOR401CLASSROOM409CLASSROOM415CLASSROOM408CLASSROOM314CORRIDOR301CLASSROOM309CLASSROOM315CLASSROOM308CLASSROOM214CLASSROOM209CLASSROOM215CORRIDOR201CLASSROOM208CLASSROOM808CLASSROOM805CLASSROOM809CORRIDOR801CLASSROOM804CORRIDOR125CLASSROOM416VESTIBULE406BOYS TOILET405JANITOR407VESTIBULE403GIRLS TOILET404DOAS-2THCORRIDOR401MECHANICAL402CLASSROOM316FACULTY DINING124OFFICETH144RESOURCE142MENS TOILET127MECHANICAL126(E)MBAH-2MEDIACENTERWORK ROOM145WOMENS TOILET141AH-4MEDIA PRODUCTION146SUPPLY140TOILET139CLINIC137TOILET131VESTIBULE152PRINCIPAL129VICE PRINCIPAL136OFFICE132VAULT135CONFERENCE133CAFETERIARECEPTION134OFFICE102LOBBY101BOYS TOILET305VESTIBULE303GIRLS TOILET304THCORRIDOR317DOAS-3MECHANICAL302CLASSROOM216VESTIBULE206BOYS TOILET205JANITOR207VESTIBULE203GIRLS TOILET204THDOAS-4MECHANICAL202CLASSROOM810CLASSROOM803SPED CONFERENCE811THMECHANICAL802DOAS-5DISH RETURN105SERVING104DISH WASH106COR1R2I5DTORELECTRICAL118BOOK STORAGEJANITOR(E)LPB116MECHANICAL117 (E)HPB(E)BOOK STORAGELPA (E)115 AH-1-1(E)HPA (E)119HPK(E)HPK1(E)LPK(E)LPK1(E)CONFERENCE120TOILET114MSB(E)FREEZER EMPLOYEE LOCKER00113COOLER00AH-1-2MA(E)MCT-LCLCWPSERVING107DAH-2DRY STORAGE112JANITOR111CAN WASHWP110DHP-2(E)OFFICE109(E)(E)(E)HP-1-2HP-1-1KITCHENDAH-1WPDHP-1CORRIDOR123CONFERENCE121CORRIDOR701CONFERENCE122BOOK ROOMSPED CONFERENCE 703702ELECT704CLASSROOM705(E)HN1(E) HNLN1 (E)LN (E)(E)VEST. JANITOR VEST.G02707G05BOYS TOILET GIRLS TOILET706708CLASSROOM709EOREGIRSTEGREDINo. PE041545PROFESSIONAL11/21/25TOENGINEERPHER G.SHRevision ScheduleNo.DescriptionDateCOMPOSITEPOWER PLAN1 COMPOSITE POWER PLANE201 1" = 20'-0"ABCDEGYMADMIN/MEDIA/CAF/KITCHENKEY PLANProject numberDateDrawn byChecked by2123NOVEMBER 2025ELPCGSE201POWER SHEET NOTESA WHERE CONNECTED TO A 20A. BRANCH CIRCUIT SUPPLYING AN INDIVIDUALRECEPTACLE (SIMPLEX OR DUPLEX), THE RECEPTACLE SHALL BE RATED AT 20A.B CIRCUIT WIRING IS NOT SHOWN, PROVIDE PROPER NUMBER OF CONDUCTORS TOACHIEVE CIRCUITING AND SWITCHING SHOWN.C CIRCUIT NUMBERS AT DEVICES CORRESPOND TO PANELBOARD BREAKERS (SEEPANELBOARD SCHEDULE). BRANCH CIRCUITS SHALL BE SIZED ACCORDING TOTHE CIRCUIT BREAKER RATING, UNLESS INDICATED OTHERWISE ON THEELECTRICAL EQUIPMENT SCHEDULE.D PROVIDE HOUSEKEEPING PADS FOR ALL FLOOR MOUNTED AND GRADE MOUNTEDELECTRICAL EQUIPMENT. MINIMUM REQUIREMENTS: 4" HIGH, 4% AIR ENTRAINED,POLYFIBER REINFORCED CONCRETE, 4" WIDER AND 4" LONGER THAN EQUIPMENTTO BE PLACED ON IT. REFER TO ELECTRICAL DETAIL DRAWINGS FORTRANSFORMER, GENERATOR, OR SWITCHGEAR PADS THAT MAY EXCEED THESEREQUIREMENTS.ADDITIONAL ROOF POWER SHEET NOTESA WHERE BRANCH CIRCUITS TO EQUIPMENT ARE INSTALLED HORIZONTALLYABOVE THE ROOF, PROVIDE ROOF SUPPORTS SUCH THAT CONDUITS AREINSTALLED APPROXIMATELY 6" ABOVE ROOF. BASIS OF DESIGN ROOFSUPPORT SHALL BE EATON DURA-BLOK. CONDUCTORS AMPACITIES,INCLUDING EQUIPMENT GROUNDING CONDUCTOR, SHALL BE INCREASED BY10% AND A MINIMUM ONE SIZE ABOVE WHAT IS INDICATED ON EQUIPMENTCONNECTIONS SCHEDULE. CONDUIT SHALL BE INCREASED AS NECESSARYFOR NEW SIZE CONDUCTORS PER NEC FILL CAPACITIES.B COORDINATE WITH DIV. 23 FOR LOCATIONS OF EQUIPMENT AND MOUNTING OFRECEPTACLES TO EQUIPMENT OR SUPPORT STRUCTURES. PROVIDEADDITIONAL RECEPTACLES ON SAME RECEPTACLE CIRCUIT AS REQUIRED TOHAVE A RECEPTACLE WITHIN 25' OF ALL EQUIPMENT.KEYNOTES1 PROVIDE NEW 25A/3P BREAKER IN EXISTING PANEL MB (MECHANICAL 126) FORCONNECTION TO NEW MECHANICAL EQUIPMENT. BREAKER AND WIRE SIZE SHALLMATCH WHAT IS SHOWN ON ELECTRICAL EQUIPMENT SCHEDULE.2 PROVIDE NEW 20A/1P BREAKER IN EXISTING PANEL LPF (ELECTRICAL 612) FORCONNECTION TO NEW WP,GFCI DUPLEX RECEPTACLE. UTILIZE ONE 1P SPACE INPANEL.1020 Drayton St., Suite 101Savannah, GA 31401(912) 963-1611www.MethodEG.comGYMNASIUMWING AWING BWING CWING DWING E1 COMPOSITE ROOF POWER PLANE202 1" = 20'-0"1HP-2HP-4(E)(E)MEDIA(E)2LC6,8(E)CAFETERIACENTER(E)(E)(E)(E)(E)KITCHEN(E)(E)EOREGIRSTEGREDINo. PE041545PROFESSIONAL11/21/25TOENGINEERPHER G.SHRevision ScheduleNo.DescriptionDateCOMPOSITEROOF POWERPLANABCDEGYMADMIN/MEDIA/CAF/KITCHENKEY PLANProject numberDateDrawn byChecked by2123NOVEMBER 2025ELPCGSE202
- Commodity Codes
-
- NAICS 238220Plumbing, Heating, and Air-Conditioning Contractors
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
26-272 Deans Bridge Road MSW ...
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-72155-NONST-2026-000000194
State Government of Georgia
Bid Due: 8/06/2026
160-172 Dalrymple Road Stormw...
Project: 160-172 Dalrymple Road Stormwater Improvement Ref. #: 26-053 Type: ITB Status: Open
City of Sandy Springs
Bid Due: 7/07/2026