Seabreeze High - Reroof Bldg. 7
Project Information
- Bid Title
- Seabreeze High - Reroof Bldg. 7
- Issuing Agency
- Volusia County Schools
- Location
- Florida
- Published Date
- Jul 7, 2026
- Closing Date
- Jul 13, 2026
- Government Level
- State & Local
- Status
- Closed
- Ref. #
- Project No. 2648242
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Seabreeze High - Reroof Bldg. 7 - Project No. 2648242
Mandatory Prebid Meeting: June 25, 2026 at 9:30 AM Bid: July 13, 2026 at 1:00 PM Project Bid Documents: Plans
Project Manual
Prebid Sign-in
Addendum No. 1 issued 7/07/2026Estimate: $387,369.04 Consultant: Gale Associates \South\, Inc.
Alan Craigo
(407) 599-7031Owner: VCS Project Manager
Tony Franco
(386) 947-8786Bid Status: Active - Attachment Preview
-
VOLUSIACOUNTY SCHOOLS"LEADING WITH GRACE AND RESPECT"THE SCHOOL BOARD OF VOLUSIACOUNTY FLORIDA200 North Clara AvenueDeLand, Florida 32720SEABREEZE HIGHREROOF BLDG. 7VCS Project NO. 26482422700 N. OLEANDER AVENUE,DAYTONA BEACH, FL 32118SCHOOL BOARDMEMBERSRUBEN COLONKRISTA GOODRICHDONNA BROSEMERJAMIE HAYNESJESSICA THOMPSONBOARD CHAIRBOARD VICE CHAIRMEMBERMEMBERMEMBERCARMEN J. BALGOBINSUPERINTENDENTGale Associates, Inc.Engineers Architects Planners217 N. Westmonte Drive, Suite 3033Altamonte Springs, FL 32714P 407.599.7031 F 407.599.7077 www.gainc.comGale Associates (South), Inc. FL CA Lic. No: 6114Boston Baltimore Orlando Hartford©2025DESCRIPTION OF WORKREPLACEMENT OF ROOFING SYSTEMS ON BUILDING 7 ( AREA A, C & D). REPAIR EXISTING ROOF SYSTEM ON AREA B ANDAPPLY A RECOVERY ROOF COATING SYSTEM.Architect's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe Florida Building Code.BUILDING DATAA. SURVEY PARCEL IDB. LEGAL DESCRIPTIONC. OCCUPANCY TYPED. CONSTRUCTION TYPEE. RISK CATEGORYF. AUTOMATIC SPRINKLERG. BUILDING AREAH. BUILDING HEIGHTI. OCCUPANT LOADN/AN/AN/AN/AIIIN/A12,200 SF (ROOFS)25 FT (DOUBLE STORY ROOFS)N/ALOCATION MAPENGINEERS & CONSULTANTSDISCIPLINE: ARCHITECTURAL / ENGINEERINGGALE ASSOCIATES\SOUTH\, INC.217 N. WESTMONTE DRIVE SUITE 3033ALTAMONTE SPRINGS, FL 32714407-599-7031WWW.GALEASSOCIATES.COMENGINEER OF RECORD: ALAN S. CRAIGOe-mail address: ASC@GAINC.COMPROJECT MANAGER: MATTHEW S. TANOUSe-mail address: MST@GAINC.COMGale Associates, Inc.Engineers Architects Planners217 N. Westmonte Drive, Suite 3033Altamonte Springs, FL 32714P 407.599.7031 F 407.599.7077 www.gainc.comGale Associates (South), Inc. FL CA Lic. No: 6114Boston Baltimore Orlando HartfordG001G002A101A301A302A501A502A503A504A505A506A507A508COVER SHEETSTANDARD LEGEND, SYMBOLS AND GENERAL NOTESROOF PLAN BLDG 7ROOF SYSTEM INFORMATIONROOF SYSTEM INFORMATIONDETAILSDETAILSDETAILSDETAILSDETAILSDETAILSDETAILSDETAILSNOT TO SCALECONSTRUCTION DOCUMENTS 04/13/2026EngineerAlan S. Craigo, P.E.ARCH/ENGR OF RECORDDESIGNED BYASC/MSTDRAWN BYJWN/VLISSUE DATE04/13/2026AE PROJECT NUMBER678444SHEET TITLECOVER SHEETDRAWING NO.G001GENERAL NOTESOVERALL CAMPUS PLANDESCRIPTION OF WORKTHE GENERAL SCOPE OF WORK FOR THIS PROJECT INCLUDES ROOF REPLACEMENT OR REPAIR AS INDICATED ON THE DRAWINGS.1. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA A): REMOVE THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEMS DOWN TO THE EXISTING LIGHTWEIGHT INSULATINGCONCRETE SUBSTRATE, REMOVE AND CAP ABANDON CURB WHERE INDICATED AND INSTALL NEW MODIFIED BITUMEN ROOFING SYSTEM WITH A REINFORCED PMMA SURFACING.REFER TO SECTION 012000 - ALTERNATES FOR MORE INFORMATION ON AREA A.2. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA B): THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOF IS SCHEDULED TO REMAIN. REPLACE ROOF DRAINS AND SCUPPERFLASHINGS AND INSTALL A NEW REINFORCED PMMA COATING OVERTOP THE EXISTING ROOF. REMOVE AND REPLACE PARAPET CAPS.3. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA C): REMOVE THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEMS DOWN TO THE EXISTING LIGHTWEIGHT INSULATINGCONCRETE SUBSTRATE, REPAIR/ REPLACE DAMAGED OR WET AREAS OF LIGHTWEIGHT INSULATING CONCRETE AND INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFINGSYSTEM.4. ON LOW-SLOPED ROOF ON BUILDING 7 (AREA D): REMOVE THE EXISTING MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEMS DOWN TO THE EXISTING LIGHTWEIGHT INSULATINGCONCRETE SUBSTRATE AND INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEM.DEMOLITION NOTES1. THE INFORMATION SHOWN ON THE DRAWINGS HAS BEEN COMPILED FROM VARIOUS SOURCES, AND MAY NOT REFLECT THE ACTUAL CONDITIONS AT THE TIME OFCONSTRUCTION. FIELD VERIFY ALL DIMENSIONS AND QUANTITIES.2. THE BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL SCHEDULE AND EXECUTE WORK TO AVOID INTERRUPTIONS TO BUILDINGOPERATIONS.3. CONTRACTOR SETUP LOCATIONS SHALL BE AS INDICATED BY THE OWNER DURING THE PRE-CONSTRUCTION MEETING.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COVERING ALL INTERIOR ITEMS THAT MIGHT BE AFFECTED BY THE WORK, INCLUDING FLOORS AND EQUIPMENT PRIOR TODEMOLITION. ONCE REMOVAL IS COMPLETE FOR THE DAY, THE PLASTIC COVERINGS SHALL BE REMOVED AND THE INTERIOR AREAS CLEANED. CLEANING SHALL INCLUDE, BUTNOT BE LIMITED TO, SWEEPING OF FLOORS AND DUST REMOVAL FROM THE TOPS OF LIGHT FIXTURES AND EQUIPMENT WHERE ACCESSIBLE.5. THE CONTRACTOR SHALL REPORT DETERIORATED OR UNSUITABLE ROOF DECK OR SUBSTRATE COMPONENTS TO THE OWNER PRIOR TO PERFORMING ROOFING INSTALLATION.6. REMOVE AND DISPOSE OF EXISTING ROOF SYSTEM AND ALL ASSOCIATED MATERIALS DOWN TO THE EXISTING STRUCTURAL DECK UNLESS OTHERWISE INDICATED ON THEDETAIL DRAWINGS TO REMAIN. REMOVE AND DISPOSE OF ALL ITEMS TO INCLUDE ROOFING, FLASHINGS, DETERIORATED BLOCKING, AND APPURTENANCES SCHEDULED TO BEREMOVED. REFER TO EXISTING ROOF SYSTEM CROSS SECTION INFORMATION ON THIS SHEET.7. PROVIDE TEMPORARY OVERHEAD PROTECTION AT THE MAIN ENTRANCE AND AT OTHER LOCATIONS AS NECESSARY TO PROVIDE UNINTERRUPTED ACCESS TO BUILDING.8. REMOVALS SHALL BE PERFORMED IN ACCORDANCE WITH THE SUBMITTED AND APPROVED REMOVAL PLAN, THE DETAIL DRAWINGS AND SPECIFICATIONS.INSTALLATION NOTES1. FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE ROOF PLANS HAS NOT BEEN INDICATED. EXISTING AND NEW DETAILS HAVE BEEN INDICATED FOR TYPICALCOMPONENTS AT RANDOM LOCATIONS.2. COMPONENTS SHOWN ON THE DETAIL DRAWINGS SHALL BE NEW UNLESS SPECIFICALLY INDICATED AS EXISTING.3. ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT.4. FOR THE SAKE OF CLARITY, SECUREMENT FASTENERS ARE NOT SHOWN ON THE DRAWINGS IN THEIR ENTIRETY. REFER TO SPECIFICATIONS FOR FASTENER TYPES/SPACING.5. ANY DISCREPANCIES ON THE DRAWINGS NOTED BY THE CONTRACTOR SHALL BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO BID SUBMISSION.6. ITEMS OF CONSTRUCTION SHALL BE 100% WATERTIGHT ON THE SAME DAY OF WORK. PHASED CONSTRUCTION MUST BE APPROVED BY THE OWNER PRIOR TO CONSTRUCTION.7. DETAILS NOT DEPICTED SHALL BE CONSTRUCTED IN A MANNER CONSISTENT WITH THE DETAIL DRAWINGS. FIELD VERIFY ALL DIMENSIONS.8. IF THERE IS A POTENTIAL HAZARDOUS MATERIAL ENCOUNTERED DURING THE COURSE OF WORK THAT IS NOT IDENTIFIED IN THE CONTRACT DOCUMENTS, THE CONTRACTORWILL STOP WORK IMMEDIATELY AND CONTACT THE OWNER WHO IS TO MAKE A DETERMINATION IF THE MATERIAL IS HAZARDOUS.9. ALL DUMPSTERS MUST BE AT LEAST 15 FEET FROM THE BUILDING UNLESS EMPTIED AT THE END OF EACH WORK DAY.10. MATERIALS MAY NOT BE STORED CLOSER THAN 15 FEET FROM BUILDINGS AND MAY NOT BE PLACED IN FRONT OF EXITS OR ANY FIRE PROTECTION EQUIPMENT. REFUELING OFGASOLINE POWERED EQUIPMENT WILL NOT BE PERMITTED ON THE ROOF. GASOLINE MUST BE STORED IN UL LISTED AND APPROVED CONTAINERS.11. METAL FABRICATION NOTES: FILE SMOOTH ALL EXPOSED SHARP EDGES. FABRICATE METAL TRANSITIONS AND TERMINATIONS IN ONE-PIECE CONSTRUCTION. LOCK AND SEAL ORSOLDER ALL JOINTS SOLID, AS SPECIFIED, TO MAKE WATERTIGHT.STATEMENT OF COMPLIANCE1. TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND THE PROJECT MANUAL ARE COMPLETE AND COMPLY WITH THE FLORIDA BUILDING CODE.2. BUILDING CODE REFERENCE: FLORIDA BUILDING CODE, 8TH EDITION (2023).N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.BUILDING 7N.I.C.N.I.C.AREA CBUILDING 7:SEE ROOF PLAN SHEET A101AREA DAREA AAREA BN.I.C.NORTHCAMPUS PLANSCALE: N.T.S.N.I.C. = NOT IN CONTRACTSTANDARD LEGEND AND SYMBOLSNOTE: NOT ALL SYMBOLS NECESSARILY USEDROOF EDGEPARAPETCRICKETVPVENT PIPE (DIAMETER SHOWN)4PRIMARY 4 INCH ROOF DRAINPRIMARY SCUPPERSOFFSECONDARY SCUPPERSEXHAUST FANVGRAVITY VENTHROOF HATCHABANDONED PENETRATIONLIGHTNING PROTECTION DOWN CONDUCTORTAPERED INSULATION SLOPESTRUCTURAL SLOPEEXPANSION JOINTVPEXHAUST VENT STACKDETAIL IDENTIFIER1A500SHEET WHERE DETAILS SHOWNSECTION INDICATORDETAIL IDENTIFIER1A500SHEET WHERE DETAILS SHOWNDETAIL INDICATORBUILDING 7 ROOF AREA SUMMARYAREA #SQUAREFOOTAGE (SF)ROOFSLOPEEXISTINGROOFNEW ROOFA9,450 S.F.1/8 : 12MOD. BIT. MOD-BIT WITH REINF.OVER LWIC* PMMA SURFACINGMOD. BIT. ROOF RECOVER WITHB2,000 S.F.1/4 : 12 OVER RIGID REINFORCED PMMAINSULATIONSURFACINGC650 S.F.1/4 : 12MOD. BIT.OVER LWICMOD. BIT. OVER LWICD100 S.F.1/8 : 12MOD. BIT.OVER LWICMOD. BIT. OVER LWICTOTAL12,200 S.F.NOTE: SEE SHEET A301 FOR ROOF SYSTEMINFORMATIONTABLE LEGENDSF= SQUARE FEETMOD. BIT. = MODIFIED BITUMEN MEMBRANE ROOFINGLWIC = LIGHTWEIGHT INSULATING CONCRETENOTE: QUANTITIES ARE PROVIDED TO ASSIST BIDDERS IN ESTABLISHING THEPROJECT SCOPE. FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS ANDQUANTITIES PRIOR TO SUBMITTING A BID FOR THIS PROJECT.* ROOF AREA A CONSISTS OF 2 LAYERS OF EXISTING ROOFING WITH 2LAYERS OF LIGHTWEIGHT CONCRETE SUBSTRATES.*REFER TO SECTION 012300 - ALTERNATES FOR ROOF AREA.ASPECIFIED PER FLORIDA BUILDING CODE (2023) CH. 16AND IN ACCORDANCE WITH ASCE 7-22ULTIMATE DESIGN WIND SPEED155 MPHNOMINAL DESIGN WIND SPEED120 MPHBUILDING RISK CATEGORYIIIWIND EXPOSUREEXPOSURE CINTERNAL PRESSURE COEFFICIENT0.18 (ENCLOSED)BUILDING HEIGHT (DESIGN MEAN)25 FTDESIGN WIND LOAD PRESSURES IN PSF(BASED ON NOM. WIND SPEED)ZONE 1'1'ZONE 11ZONE 22ZONE 33N/A-55.43-73.12-99.66* ANSI/SPRI ES-1 TEST METHODS FOR COPINC CAP ANDEDGE METAL SYSTEMS:- MIN. HORIZONTAL LOAD: 108 PSF (CORNERS 134 PSF)- MIN. VERTICAL LOAD: 186 PSF (CORNERS 280 PSF)WIND DESIGN INFORMATION15'-0"TYP.335'-0" TYP.25'-0"TYP.2213315'-0"TYP.325'-0" TYP.3WIND LOAD SCHEMATICSCALE = N.T.S.15'-0"TYP.3125'-0" TYP.332315'-0"TYP.215'-0"TYP.3Gale Associates, Inc.Engineers Architects Planners217 N. Westmonte Drive, Suite 3033Altamonte Springs, FL 32714P 407.599.7031 F 407.599.7077 www.gainc.comGale Associates (South), Inc. FL CA Lic. No: 6114Boston Baltimore Orlando Hartford©2025EngineerAlan S. Craigo, P.E.ARCH/ENGR OF RECORDDESIGNED BYASC/MSTDRAWN BYJWN/VLISSUE DATE04/13/2026AE PROJECT NUMBER678444SHEET TITLESTANDARD LEGEND,SYMBOLS ANDGENERAL NOTESDRAWING NO.G002KEY NOTESROOF REPLACEMENT NOTESALTERNATE NO. 11 REMOVE EXISTING ABANDONED PIPE PENETRATINS THROUGH THE ROOF, FILL IN ROOF ASINDICATED AND ROOF OVER. SEE DETAIL 5/A501.2 POWERWASH SURFACES OF (EACH) EXISTING PAINTED CONCRETE EYEBROWS, REMOVEEXISTING LOOSE COATINGS, AND APPLY A NEW ACRYLIC WATERPROOF COATING ASSPECIFIED (WITH INTEGRAL WHITE FINISH COLOR). SEE DETAIL 2/A501 (QTY 14, VERIFY).1. ROOF AREA A, C & D1.1. REMOVE EXISTING MULTI-PLY MODIFIED BITUMEN ROOF ASSEMBLY (AND MECHANICALLY ATTACHEDBASE SHEET) DOWN TO THE EXISTING LIGHTWEIGHT INSULATING CONCRETE (LWIC) SUBSTRATE.INSTALL NEW MULTI-PLY MODIFIED BITUMEN ROOFING SYSTEM (WITH MECHANICALLY ATTACHEDBASE SHEET) AS SPECIFIED. REFER TO ROOF SYSTEM CROSS SECTION INFORMATION, SHEET A301.ROOF AREA A: AS AN ALTERNATE TO THE BASE BID SCOPE OF WORK, WHICH INCLUDESTHE APPLICATION OF REINFORCED PMMA SURFACING OVER THE NEW MODIFIED BITUMENROOFING SYSTEM, PROVIDE AN ALTERNATE (DEDUCT) COST FOR INSTALLING A 3-PLYMODIFIED BITUMEN ROOF SYSTEM (2 BASE-PLIES WITH 1 GRANULE SURFACED CAP SHEETPLY WITH BRIGHT WHITE GRANULES). REFER TO SECTION 012300-ALTERNATES3 AT EXISTING LOCATIONS WHERE THERE IS EVIDENCE OF A HISTORY OF STANDING WATER,REMOVE EXISTING ROOFING DOWN TO THE EXISTING LIGHTWEIGHT INSULATING CONCRETE(LWIC) SUBSTRATE. CUT OUT AND REMOVE TOP SURFACE (APPROX. 2-INCHES) OF LWIC ANDREPAIR AS SPECIFIED AND FLOAT SURFACE OF LWIC TO MAINTAIN POSITIVE ROOF SLOPE TOHELP ELIMINATE EXISTING “FLAT AREAS” WHERE STANDING WATER OCCURS. SEE DETAILS5/A301 (QTY. UP TO 40 SF).4 REMOVE AND REPLACE EXHAUST VENT/CAP AT EXISTING VENT FLUE ON AREA B ASINDICATED. CORROSION TREAT AND APPLY PMMA FLASHING ONTO EXISTING GALVANIZEDFLUE. INSPECT EACH VENT FROM SOURCE BELOW, DO NOT INSTALL SCREEN WITH VENT CAPAT ANY DRYER VENTS. SEE DETAIL 1/A504.5 INSTALL NEW SECONDARY (OVERFLOW) SCUPPERS THROUGH THE EXISTING PARAPETWHERE INDICATED (SIZE: 10”W X 4”H). LOCATE SECONDARY SCUPPERS WITHIN 2-FT MIN. OR4-FT MAX. FROM THE EXISTING PRIMARY SCUPPERS. FIELD VERIFY EXISTING WALLCONSTRUCTION PRIOR TO INSTALLING SECONDARY SCUPPERS. SEE DETAIL 5/A504.6 REMOVE AND REPLACE EXISTING ROOF DRAINS WHERE INDICATED ON AREA B, REPLACINGROOFING AND INSULATION AROUND EACH DRAIN TO FORM A 4-FT X 4-FT SUMP, AND TIE BACKINTO THE EXISTING ROOFING SYSTEM PRIOR TO THE APPLICATION OF THE NEW REINFORCEDPMMA ROOF SURFACING. SEE DETAIL 1/A503.1.2. ROOF AREA A: APPLY A REINFORCED FLUID-APPLIED PMMA SURFACE OVER TOP OF THE NEWMODIFIED BITUMEN MEMBRANE ROOF AS INDICATED (AREA A ONLY). *SEE ALTERNATE NO. 1.1.3. ROOF AREA C: REPLACE EXISTING SCUPPER DRAIN FLASHINGS, CONDUCTOR BOXES ANDDOWNSPOUTS AND INSTALL NEW OVERFLOW SCUPPERS AS INDICATED.1.4. SLOPE IS BUILT INTO THE EXISTING LWIC ROOF SUBSTRATE, SEE ROOF PLAN BELOW.2. ROOF AREA B2.1. EXISTING MULTI-PLY MODIFIED BITUMEN ROOF MEMBRANE IS SCHEDULED TO REMAIN IN PLACE.REPAIR EXISTING ROOFING AND FLASHING AND INSTALL NEW REINFORCED FLUID-APPLIED PMMASURFACING AS INDICATED. REFER TO ROOF SYSTEM CROSS SECTION INFORMATION, DETAIL 3/A301.2.2. REPLACE ROOF DRAINS AND OVERFLOW SCUPPERS FLASHINGS AS INDICATED.2.3. SLOPE IS BUILT INTO THE EXISTING STEEL ROOF DECK, SEE ROOF PLAN BELOW.3. PROVIDE ROOF PROTECTION (WALKWAY) PATHS WHERE INDICATED ONTHE ROOF PLAN, INCLUDING AROUND SERVICEABLE ROOFTOPEQUIPMENT. COORDINATE PLACEMENT AND LAYOUT WITH OWNER.7 REMOVE AND REPLACE EXISTING SECONDARY (OVERFLOW) SCUPPER FLASHINGS (SIZE: 8”WX 4”H) AND TIE BACK INTO THE EXISTING ROOFING SYSTEM PRIOR TO THE APPLICATION OF3.1. NOTE: FOR FLUID-APPLIED ROOF SURFACE AREAS, WALKWAYS (OR WALKPATHS) MAY BE PROVIDEDUSING AN ADDITIONAL LAYER OF GREY-COLORED PMMA SURFACING WITH SKID RESISTANT FINISHTHE NEW REINFORCED PMMA ROOF SURFACING. SEE DETAIL 2/A503.4. ROOFTOP LIGHTNING PROTECTION: REMOVE AND REPLACE EXISTING ALUMINUM ROOFTOP LIGHTNING28 PROVIDE CONCRETE SPLASH BLOCK AT THE BASE OF DOWNSPOUTS AS SPECIFIED.PROTECTION SYSTEM TO ACCOMMODATE ROOF REPLACEMENT AS INDICATED. INSTALL NEWCOMPONENTS TO REPLACE MISSING OR DAMAGED TO PROVIDE A COMPLETE SYSTEM AS SPECIFIED.A5052A506N.I.C.2 TYP.2 TYP.1A501TYP.165'-6"±2 TYP.1A505LIGHTNING PROTECTIONTHROUGH COPING CAP, SEE1/A5085VP3VPA504OFEXISTING J-BOX THRUROOF FLASHINGS,SEE 6/A50482A50441'-6"±3A501WALKWAY, SEENOTE 3.1 ABOVE84A504OF5VPVP2A502FSIM.WALKWAY, SEENOTE 3.1 ABOVEVPHISTORY OF STANDING WATERIN THESE LOCATIONS, TYP. 33VPA502TYP.VPVPVP3VPA502TYP.3A502 TYP. VP4A501HISTORY OF STANDING WATERIN THESE LOCATIONS, TYP. 3ADJACENT ROOF (N.I.C.)RAISED EXPANSION JOINTWALKWAY1A501TYP.LIGHTNING PROTECTIONTHROUGH COPING CAP, SEE1/A50816'-0"±1A506N.I.C.PROVIDE GUTTERS AT ROOF CORNERWHERE INDICATED (EXTEND MIN. 6-FT INEACH DIRECTION FROM CORNER, TYP.),SEE 4/A502NOTE: PROVIDE SPLASH PAN AT BASEOF DOWNSPOUT ON EXISTING CANOPY,SEE 3/A507VPDS11A501TYP.WALKWAY, SEENOTE 3.1 ABOVEVP V1A502H6A501PROVIDE SAFETY RAILING ATROOF HATCH EGRESS AREA TOMEET CODE REQUIREMENTS,EXTEND MIN. 48-INCHESBEYOND EDGE OF HATCH,SEE 5/A5021A501TYP.HISTORY OF STANDING WATERIN THESE LOCATIONS, TYP. 32 TYP.2 TYP.5A5065A5034A5033A508462 TYP.DS13A501 A503TYP.3A5031A501TYP.VP VP VP644A50346465A50348'-6"±N.I.C.5A506SIM.PROVIDE GUTTERS AT ROOF CORNERWHERE INDICATED (EXTEND MIN. 6-FT INEACH DIRECTION FROM CORNER, TYP.),SEE 4/A502NOTE: EXTEND DOWNSPOUT TO DEPOSITRUNOFF TO ROOF BELOW AND PROVIDECONCRETE SPLASHBLOCK SET INADHESIVE ONTO ROOF SURFACE.OF7PLANNORTH1 ROOF PLAN BUILDING 7A101 SCALE: 1/8"=1'-0"OF64'-6"±7OF57A503Gale Associates, Inc.Engineers Architects Planners217 N. Westmonte Drive, Suite 3033Altamonte Springs, FL 32714P 407.599.7031 F 407.599.7077 www.gainc.comGale Associates (South), Inc. FL CA Lic. No: 6114Boston Baltimore Orlando Hartford©2025EngineerAlan S. Craigo, P.E.ARCH/ENGR OF RECORDDESIGNED BYASC/MSTDRAWN BYJWN/VLISSUE DATE04/13/2026AE PROJECT NUMBER678444SHEET TITLEDRAWING NO.ROOF PLANBLDG 7A101EXISTING 2-PLY MODIFIED BITUMEN ROOFMEMBRANE SYSTEM AND MECHANICALLY ATTACHEDBASE SHEET, TO BE REMOVEDEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC), TO REMAIN· LWC TOPPING AVERAGE 2" THICK· EPS INSULATION VARIES TYP. 1" TO 8"±EXISTING MODIFIED BITUMEN ROOF SYSTEM WITHMECHANICALLY ATTACHED BASE SHEET, TO REMAINEXISTING CELLULAR LIGHTWEIGHT CONCRETE,TO REMAINEXISTING ROOF SYSTEMEXISTING CORRUGATED STEEL FORM DECK,TO REMAINREINFORCED FLUID APPLIED (PMMA) SURFACINGOVER (NEW) MODIFIED BITUMEN ROOF SYSTEM,SEE 4/A302MODIFIED BITUMEN ROOF MEMBRANE: SMOOTHSURFACED BASE-PLY MEMBRANE OVER MECH.ATTACHED BASE SHEET (TORCH APPLIED)MECHANICALLY ATTACHED BASE SHEETEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC)· LWC TOPPING AVERAGE 2" THICK· EPS INSULATION VARIES TYP. 1" TO 5"±EXISTING MODIFIED BITUMEN ROOF SYSTEM WITHMECHANICALLY ATTACHED BASE SHEETEXISTING CELLULAR LIGHTWEIGHT CONCRETENEW ROOF SYSTEMEXISTING CORRUGATED STEEL FORM DECKNOTE: REFER TO ALTERNATE DETAIL 6/A302 AND SECTION 012300 - ALTERNATES FOR ROOF AREA A.1 ROOF SYSTEM CROSS SECTION INFORMATION (AREA A)A301 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING 2-PLY MODIFIED BITUMEN ROOF MEMBRANE:GRANULAR SURFACED CAP SHEET OVER SMOOTHBASE-PLY MEMBRANE, TO REMAINEXISTING 5/8" THICK GYPSUMCOVERBOARD, TO REMAINEXISTING ROOF SYSTEMREINFORCED FLUID APPLIED (PMMA) SURFACING OVER(EXISTING) MODIFIED BITUMEN ROOF SYSTEM,SEE 5/A302EXISTING 2-PLY MODIFIED BITUMEN ROOF MEMBRANE:GRANULAR SURFACED CAP SHEET OVER SMOOTHBASE-PLY MEMBRANEEXISTING 5/8" THICK GYPSUM BOARD,TO REMAINEXISTING 3" POLYISOCYANURATEINSULATION, TO REMAINEXISTING SLOPED TYPE -B STEEL DECK,TO REMAINEXISTING 5/8" THICKGYPSUM COVERBOARDNEW ROOF SYSTEMEXISTING 5/8" THICK GYPSUMCOVERBOARDEXISTING 3" POLYISOCYANURATEINSULATIONEXISTING SLOPED TYPE -B STEEL DECKNOTE: FOR TYP. ROOF REPAIRS, SEE 5/A3012 ROOF SYSTEM CROSS SECTION INFORMATION (AREA B)A301 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING ROOF SYSTEMEXISTING 2-PLY MODIFIED BITUMEN ROOFMEMBRANE SYSTEM AND MECHANICALLYATTACHED BASE SHEET, TO BE REMOVEDEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC), TO REMAIN· LWC TOPPING AVERAGE 3" THICK· EPS INSULATION VARIES TYP. 3.5" TO 8"±EXISTING CORRUGATED STEEL FORM DECK,TO REMAINGale Associates, Inc.Engineers Architects Planners217 N. Westmonte Drive, Suite 3033Altamonte Springs, FL 32714P 407.599.7031 F 407.599.7077 www.gainc.comGale Associates (South), Inc. FL CA Lic. No: 6114Boston Baltimore Orlando Hartford©20252-PLY MODIFIED BITUMEN ROOF MEMBRANE:GRANULAR SURFACED CAP SHEET OVER SMOOTHBASE-PLY MEMBRANE (TORCH APPLIED)MECHANICALLY ATTACHED BASE SHEETEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC), TO REMAIN· LWC TOPPING AVERAGE 3" THICK· EPS INSULATION VARIES TYP. 3.5" TO 8"±NEW ROOF SYSTEMNOTE: FOR TYP. LWIC REPAIRS, SEE 6/A301EXISTING CORRUGATED STEEL FORM DECK3 ROOF SYSTEM CROSS SECTION INFORMATION (AREA C)A301 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING ROOF SYSTEMEXISTING 2-PLY MODIFIED BITUMEN ROOFMEMBRANE SYSTEM AND MECHANICALLYATTACHED BASE SHEET, TO BE REMOVEDEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC), TO REMAINEXISTING PRECAST CONCRETE DECK,TO REMAIN2-PLY MODIFIED BITUMEN ROOF MEMBRANE:GRANULAR SURFACED CAP SHEET OVER SMOOTHBASE-PLY MEMBRANE (TORCH APPLIED)MECHANICALLY ATTACHED BASE SHEETEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC)EXISTING PRECAST CONCRETE DECKNEW ROOF SYSTEMNOTE: FOR TYP. LWIC REPAIRS, SEE 6/A3014 ROOF SYSTEM CROSS SECTION INFORMATION (AREA D)A301 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)CUT OUT AND REMOVE BLISTERED MEMBRANE OR WHEREWRINKLES OR OTHER DAMAGE IS OBSERVED, REPAIR BACK TOWHERE EXISTING SUBSTRATE MATERIAL IS SOUND AND DRYCUT OUT AND REMOVE EXISTING INSULATION SUBSTRATEMATERIALS WHERE FOUND TO BE DAMAGED OR IF MOISTUREIS IDENTIFIED, REPAIR BACK TO EXISTING GOOD (SOUND/DRY)SUBSTRATE; FOR SUBSTRATE MATERIALS REFER TO 2/A301STEP 1EXISTING STEEL ROOF DECKREINFORCED FLUID-APPLIED (PMMA) ROOF COATING SYSTEMCONTINUOUS OVER THE WHOLE ROOF AREA (APPLY AFTERPATCH HAS CURED)COVER REPAIR AREA WITH MIN. 1-LAYER OF GRANULARSURFACED MODIFIED BITUMEN ROOFING MEMBRANE,TORCH-ADHERE AND EXTEND MIN. 4" ONTO ADJACENTEXISTING ROOF SURFACE (DE-GRANULATE CAP SHEETAT OVERLAP TO ENSURE ADHESION ); THEN APPLYREINFORCED FLUID-APPLIED MEMBRANE PATCH, EXTENDPATCH MIN. 6" BEYOND THE REPAIRINSTALL SAME NUMBER OF PLIES AS ARE REMOVED, BUILDUP DEPRESSION IN ROOFING AT PATCH LOCATION TO MAKESURFACE LEVELEXISTING MODIFIED BITUMEN ROOFING WITH GRANULARSURFACED CAP SHEETSTEP 2REPLACE EXISTING INSULATION SUBSTRATE MATERIALS ONLYAS REQUIRED TO ADDRESS DAMAGE, AS INDICATED ABOVEEXISTING STEEL ROOF DECK5 TYP. REPAIRS TO EXISTING ROOF ASSEMBLY (AREA B)A301 SCALE: 3" = 1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)REMOVE AND REPLACE ROOFINGAS INDICATED, SEE 1/A301ROOF AREA AREMOVE AND REPLACE ROOFINGAS INDICATED, SEE 3/A301INSPECT UNDERLYING LIGHTWEIGHT INSULATINGCONCRETE (LWIC) SUBSTRATES FOR DAMAGE ORMOISTURE, CUT OUT AND PATCH AS SPECIFIED(FLOAT TO MAINTAIN POSITIVE ROOF SLOPE ANDALLOW TO CURE BEFORE INSTALLING ROOFING)REMOVE DAMAGED OR WET LWIC BACK TOSOUND/DRY SUBSTRATE MATERIALSCUT OUT AND REPLACE EXISTING RIGIDPOLYSTYRENE INSULATION BOARDS ATISOLATED AREAS TO FACILITATE REPAIRSAT REPAIR AREAS, INSPECT FOR MOISTUREBETWEEN ROOF SYSTEMS AND VACUUM OUTMOISTURE WHERE OBSERVEDEXISTING ASPHALT MEMBRANE ROOF SYSTEM(BETWEEN LWIC LAYERS). PATCH OR REPAIRWHERE DAMAGED DURING DEMO PROCEDURESEXISTING LIGHTWEIGHT CONCRETE ONCORRUGATED STEEL FORM DECKINSPECT UNDERLYING LIGHTWEIGHT INSULATINGCONCRETE (LWIC) SUBSTRATES FOR DAMAGE ORMOISTURE, CUT OUT AND PATCH AS SPECIFIED(FLOAT TO MAINTAIN POSITIVE ROOF SLOPE ANDALLOW TO CURE BEFORE INSTALLING ROOFING)REMOVE DAMAGED OR WET LWIC BACK TOSOUND/DRY SUBSTRATE MATERIALSCUT OUT AND REPLACE EXISTING RIGIDPOLYSTYRENE INSULATION BOARDS ATISOLATED AREAS TO FACILITATE REPAIRSROOF AREA C, DEXISTING CORRUGATED STEEL FORM DECK6 TYP. REPAIRS TO LWIC (AREA A, C, D)A301 SCALE: 3" = 1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EngineerAlan S. Craigo, P.E.ARCH/ENGR OF RECORDDESIGNED BYASC/MSTDRAWN BYJWN/VLISSUE DATE04/13/2026AE PROJECT NUMBER678444SHEET TITLEROOF SYSTEMINFORMATIONDRAWING NO.A3018"MIN.3"4" MIN.SECTIONEXTEND ROOFMEMBRANE ABOVE HEADOF CANT AND ADHERETO WALL OR ROOF CURBTERMINATION BAR2-PLY MODIFIED BITUMENBASE FLASHINGLOW PROFILEFIBER CANT2" MIN.NOTE: FIBER CANT STRIPS MAY BE ELIMINATEDWHEN USING POLYESTER - REINFORCEDMEMBRANE BASE FLASHINGS, WITH ROOFSYSTEM MANUFACTURER WRITTEN CONSENT.NOTE: FOR WOOD OR PLYWOOD SUBSTRATES,UTILIZE A SELF-ADHERING BASE PLY FLASHINGMEMBRANE WITH TOP SURFACE CAPABLE OFTORCHING TOP PLIES, AS SPECIFIED.ROOF CURB OR RISING WALLNEW MODIFIED BITUMEN BASE FLASHINGMEMBRANE (SMOOTH), UP AND OVER TOPOF CURB/WALL AS SHOWNSEE SHEET A301EXISTING OR NEW ROOFINGAND BASE FLASHINGS,REFER TO ROOF SYSTEMASSEMBLY INFORMATIONON SHEET A302, AND SEEDETAIL 1/A302GRANULAR SURFACED MODIFIED BITUMENBASE FLASHING CAP PLYSEE SHEET A301ROOF CURB OR RISING WALLREINFORCED FLUID-APPLIED (PMMA)BASE FLASHING SYSTEMREINFORCED FLUID-APPLIED (PMMA) ROOFSURFACING OR COATING SYSTEMGRANULAR SURFACED MODIFIEDBITUMEN ROOF MEMBRANE CAP SHEETSEE SHEET A301MODIFIED BITUMEN ROOF MEMBRANE BASEPLY (SMOOTH)SEE SHEET A301LOW PROFILE FIBER CANT STRIP, SET INADHESIVE AND APPLY PRIMER OVER FACETO RECEIVE ROOFINGLIGHTWEIGHT INSULATING CONCRETE (LWIC)SUBSTRATE (BASE SHEET NOT SHOWN)SEE SHEET A3011 TYP. MOD. BIT. MEMBRANE BASE FLASHING INSTALLATIONA302 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)CLEAN AND PREP ROOF SURFACE TORECEIVE FLUID-APPLIED ROOFING ANDFLASHING SYSTEM(S)2 TYP. FLUID-APPLIED BASE FLASHINGA302 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING OR NEW ROOFING ANDFLASHINGS, REFER TO ROOF SYSTEMASSEMBLY INFORMATION ON SHEET A302ROOFING SUBSTRATE VARIESSEE SHEET A301FLUID-APPLIED ROOF COATING TOPCOAT, 2-LAYERS (OR AS REQUIREDTO MEET SPECIFIED WARRANTYREQUIREMENTS), ENTIRE ROOFFLUID-APPLIED ROOF COATING,BASE COATPOLYESTERREINFORCEMENT FABRICFLUID-APPLIED ROOF COATING TOPCOAT, 2-LAYERS (OR AS REQUIREDTO MEET SPECIFIED WARRANTYREQUIREMENTS), ENTIRE ROOFFLUID-APPLIED ROOF COATING,BASE COATPOLYESTERREINFORCEMENT FABRICREINFORCED FLUID-APPLIED (PMMA) SURFACINGOVER MODIFIED BITUMEN ROOF SYSTEM WHERESPECIFIED, SEE SHEET A301Gale Associates, Inc.Engineers Architects Planners217 N. Westmonte Drive, Suite 3033Altamonte Springs, FL 32714P 407.599.7031 F 407.599.7077 www.gainc.comGale Associates (South), Inc. FL CA Lic. No: 6114Boston Baltimore Orlando HartfordMODIFIED BITUMEN ROOF6"MEMBRANE STRIPPING PLYMETAL FLANGE, PRIME BOTHSIDES, SET IN ROOF MASTIC ANDFASTEN TO WOOD BLOCKING©2025EDGE METALTURN BASE PLY MEMBRANE DOWNOVER FACE BEHIND METAL TOCOVER WOOD BLOCKING ORWRAP EDGE WITH SELF-ADHEREDMEMBRANE FLASHINGPERIMETER WOOD BLOCKING, TOMATCH INSULATION HEIGHT ANDFLUSH WITH EDGE, TYP.EXISTING LIGHTWEIGHTINSULATING CONCRETE (LWIC)SUBSTRATEMODIFIED BITUMEN ROOFMEMBRANE BASE PLY (SMOOTH),OVER MECHANICALLY ATTACHEDBASE SHEET, TYP.3 TYP. EMBEDDED EDGE FLASHING (AREA A)A302 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING 2-PLY MODIFIED BITUMEN ROOFMEMBRANE SYSTEM AND MECHANICALLY ATTACHEDBASE SHEET, TO BE REMOVEDEXISTING ROOF SYSTEMEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC), TO REMAIN· LWC TOPPING AVERAGE 2" THICK· EPS INSULATION VARIES TYP. 1" TO 8"±EXISTING MODIFIED BITUMEN ROOF SYSTEM WITHMECHANICALLY ATTACHED BASE SHEET, TO REMAINEXISTING CELLULAR LIGHTWEIGHT CONCRETE,TO REMAINEXISTING CORRUGATED STEEL FORM DECK,TO REMAINPROVIDE SURFACE PRIMERS ORCONDITIONERS AS REQUIRED BY THEMANUFACTURER TO PROMOTE ADHESION.NOTE: FOR FLUID-APPLIED ROOF SURFACE AREAS,WALKWAYS (OR WALKPATHS) MAY BE PROVIDEDUSING AN ADDITIONAL LAYER OF GREY-COLOREDPMMA SURFACING WITH SKID RESISTANT FINISHMODIFIED BITUMEN ROOF MEMBRANE:SMOOTH SURFACED BASE PLY MEMBRANEOVER MECHANICALLY ATTACHED BASESHEET (TORCH APPLIED) SEE 1/A301ALTERNATE (AREA A): AS AN ALTERNATE TO APPLYING A MODIFIEDBITUMEN ROOF SYSTEM WITH PMMA SURFACING, PROVIDE A DEDUCTCOST FOR INSTALLING A 3-PLY MODIFIED BITUMEN ROOF SYSTEM(2-BASE PLIES WITH 1 GRANULE SURFACED CAP PLY). REFER TOALTERNATES, SECTION 012300 AND DETAIL 6/A302.4 TYP. FLUID-APPLIED ROOF SURFACING SYSTEM (AREA A)A302 SCALE: NTS(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EXISTING MODIFIED BITUMEN ROOFINGSYSTEM WITH GRANULAR SURFACED CAPSHEET, MAKE REPAIRS THEN CLEAN ANDAPPLY CONDITIONER AND/OR PRIMER ASPRESCRIBED BY THE MANUFACTURER TOPROMOTE ADHESION5 TYP. FLUID-APPLIED ROOF COATING SYSTEM (AREA B)A302 SCALE: NTS(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)3-PLY MODIFIED BITUMEN ROOF MEMBRANE:GRANULAR SURFACED CAP SHEET OVER 2-PLIES OFSMOOTH BASE PLY MEMBRANE(S) (TORCH APPLIED).MECHANICALLY ATTACHED BASE SHEETEXISTING TAPERED CELLULAR LIGHTWEIGHTINSULATING CONCRETE (LWIC)· LWC TOPPING AVERAGE 2" THICK· EPS INSULATION VARIES TYP. 1" TO 5"±EXISTING MODIFIED BITUMEN ROOF SYSTEM WITHMECHANICALLY ATTACHED BASE SHEETEXISTING CELLULAR LIGHTWEIGHT CONCRETENEW ROOF SYSTEM (ALTERNATE)EXISTING CORRUGATED STEEL FORM DECKNOTE: THIS ROOF SYSTEM CROSS SECTIOPN IS PROVIDED AS AN ALTERNATE TO 1/A301, REFER TO SECTION 012300 - ALTERNATES6 ALTERNATE ROOF SYSTEM (AREA A)A302 SCALE: 3"=1'-0"(ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING)EngineerAlan S. Craigo, P.E.ARCH/ENGR OF RECORDDESIGNED BYASC/MSTDRAWN BYJWN/VLISSUE DATE04/13/2026AE PROJECT NUMBER678444SHEET TITLEROOF SYSTEMINFORMATIONDRAWING NO.A302
- Commodity Codes
-
- NAICS 236220Commercial and Institutional Building Construction
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
Columns Repair and Structural...
Title: Columns Repair and Structural Improvements at Northeast Transfer Station Truck Wash Building
Miami-Dade County
Bid Due: 8/14/2026
Vault Room and Oil Room Project
Project ID: Title: Vault Room and Oil Room Project Addenda: 0 Release Date:
Sarasota County
Bid Due: 8/26/2026