Structural Reading Pavilion Dalton Whitfield County Public Library
Project Information
- Bid Title
- Structural Reading Pavilion Dalton Whitfield County Public Library
- Issuing Agency
- Whitfield County
- Location
- Georgia
- Published Date
- Oct 24, 2025
- Closing Date
- Nov 24, 2025
- Government Level
- State & Local
- Status
- Closed
- Original Source
- Join to Access Full Details
- Bid Inquiries
- Join to Access Full Details
- Bid Documents
- Join to Access Full Details
- Project Description
-
Description Opening Date/Time Closing Date/Time
Structural
Reading Pavilion Dalton Whitfield County Public Library
October 24, 2025
8:00
AM
November 24, 2025
2:00
PM
- Attachment Preview
-
I. GENERAL NOTESA. THESE NOTES SHALL APPLY EXCEPT WHERE OTHERWISE INDICATED BYTHE DRAWINGS OR SPECIFICATIONS.B. WHERE A DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FORALL LIKE OR SIMILAR CONDITIONS EVEN THOUGH NOT SPECIFICALLYMARKED ON THE DRAWINGS.C. IF APPLICABLE, CONTRACTOR SHALL CHECK AND VERIFY ALL DIM-ENSIONS AND CONDITIONS OF EXISTING BUILDINGS AFFECTING NEWCONSTRUCTION, AND DISCREPANCIES ARE TO BE REPORTED IMMEDIATELYTO THE ARCHITECT/ENGINEER IN WRITING.D. GENERAL CONTRACTOR SHALL ENSURE THAT ALL MATERIALS ARE INCOMPLIANCE WITH THE PLANS AND SPECIFICATIONS.E. ALL MASONRY WALLS BELOW GRADE SHALL BE BACKFILLED ON BOTHSIDES OF WALL SIMULTANEOUSLY. PROVIDE TEMPORARY BRACING ASREQUIRED TO ADEQUATELY SUPPORT STRUCTURE DURING CONSTRUCTIONAND BACKFILLING. BRACING SHALL REMAIN IN PLACE UNTIL ALL FLOORAND ROOF CONNECTIONS ARE COMPLETE.F. CENTER LINE OF COLUMN = CENTER LINE OF FOOTING = CENTER LINEOF ANCHOR BOLT TEMPLATE UNLESS NOTED OTHERWISE. NO PIPINGSHALL PASS THROUGH OR UNDER ANY FOOTING WITHOUT PRIOR APPROVALOF THE ENGINEER.G. DIMENSIONS AT FRAMED OPENINGS TO BE VERIFIED WITH APPLICABLESUB-CONTRACTOR BEFORE FABRICATION OF STEEL. IF ANY DISCREPANCIESARE FOUND, THE ARCHITECT/ENGINEER IS TO BE IMMEDIATELY NOTIFIEDIN WRITING.H. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONSPRIOR TO ORDERING MATERIAL. DISCREPANCIES BETWEEN FIELD MEASURMENTSOF THE EXISTING CONDITIONS AND THE DIMENSIONS INDICATED ON THECONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTIONOF THE ENGINEER.I. SUBMIT SHOP DRAWINGS OF ALL FABRICATED MATERIALS FOR REVIEW. CONTRACTDOCUMENTS REPRODUCED FOR USE AS SHOP DRAWINGS WILL BE RETURNEDUNREVIEWED AND UNSTAMPED. SHOP DRAWINGS WILL NOT BE REVIEWED UNLESSTHEY ARE STAMPED "APPROVED" OR "APPROVED AS NOTED" BY THE GENERALCONTRACTOR.J. COORDINATE FOUNDATION TO ACCOMODATE DESIGN OF METAL BY OTHERS.II. DESIGN CRITERIA:A. BUILDING CODE : 2018 INTERNATIONAL BUILDING CODEB. DESIGN LOADS:1. ADDITIONAL DESIGN LOADS INDICATED ON STRUCTURALDRAWINGS SHALL BE IDENTIFIED AS FOLLOWS:LL = LIVE LOADWL = WIND LOADEL = SEISMIC LOADSN = SNOW LOADSD = SNOW DRIFT2. WIND:a. VULT = 105 mphb. RISK CATEGORY = II IMPORTANCE FACTOR = 1.00c. MEAN ROOF HT = 22'-6"d. EXPOSURE Be. END ZONE = 5'-0"f. ENCLOSED BUILDING, GC pi=+/-0.18g. WIND PRESSURES FOR COMPONENTS AND CLADDING BY TRIBUTARY AREA.VALUES BASED ON WINDSPEED=105 MPH AND EXPOSURE=B. VALUES AREUNFACTORED AND MAY BE USED IN EITHER STRENGTH DESIGN ORALLOWABLE STRESS DESIGN LOAD COMBINATIONS OF ASCE 7-10.REGION10 ft 21+11.2/-40.8TRIBUTARY AREA20 ft250 ft 2+9.2/-40.8+8.2/-22.42e +11.2/-40.8+9.2/-40.8+8.2/-22.42n +11.2/-61.2+9.2/-53.0+8.2/-40.82r+11.2/-61.2+9.2/-53.0+8.2/-40.83e +11.2/-61.2+9.2/-53.0+8.2/-40.83r+11.2/-73.4+9.2/-61.2+8.2/-49.04 +20.4/-22.4+19.4/-20.4+17.3/-20.45+20.4/-28.6+19.4/-26.5+17.3/-24.5LOADS TO BE APPLIED PER FIGURES 30.3-1 AND 30.3-2B OFASCE 7-16.100 ft 2+6.1/-10.2+6.1/-10.2+6.1/-32.6+6.1/-32.6+6.1/-32.6+6.1/-36.7+16.3/-18.4+16.3/-20.4III. CONCRETE:A. CONCRETE SHALL BE PROPORTIONED, MIXED AND PLACED IN ACCORDANCE WITHACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ANDACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS."B. CEMENT TO BE PORTLAND TYPE 1 OR APPROVED EQUAL.C. MIX DESIGN SHALL BE DOCUMENTED IN ACCORD WITH SECTION 03300 OF THEPROJECT SPECS AND ACI 301, CHAPTER 3 "PROPORTIONING". MIX DESIGNSWHICH ARE SUBMITTED WITHOUT THE REQUIRED DOCUMENTATION WILL BEREJECTED. FIELD SLUMPS RECORDED AT JOB SITE SHALL NOT EXCEED THESLUMP ESTABLISHED FOR THE MIX DESIGN.D. CONCRETE SHALL HAVE AN ALLOWABLE COMPRESSIVE STRENGTH ASNOTED BELOW:* INTERIOR SLABS ON GRADE, F'c = 3,000 PSIFOUNDATIONSF'c = 3,000 PSIE. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT:FOOTINGS3"F. EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3/4 INCH UNLESSNOTED.G. CONCRETE SHALL NOT BE POURED IN WATER OR ON FROZEN GROUND ANDSHALL BE PROTECTED FROM FROST DURING CONSTRUCTION.H. CONTRACTOR SHALL COORDINATE ALL CONTRACT DRAWINGS FOR THELOCATION OF ANCHOR BOLTS, FLOOR DRAINS, INSERTS, ETC., BEFOREPOURING CONCRETE.I. SLABS:1. SLAB THICKNESS INDICATED ON DRAWINGS IS MINIMUM AND SHALL BEMEASURED FROM LOW POINT ON FLOOR. CONTRACTOR SHALL COORDINATEALL DRAWINGS TO ASSURE THAT ALL FLOORS HAVE PROPER SLOPE TODRAIN IN TOILETS, SHOWERS, ETC.2. "C.J.", AS INDICATED ON SLAB, INDICATES 3/4" DEEP SAW CUT CONTROLJOINT OR KEYED CONSTRUCTION JOINT IN SLAB-ON-GRADE. MAKE CUTSWITHIN 12 HOURS AFTER CONCRETE PLACEMENT.J. REINFORCEMENT:1. ALL DETAILING, FABRICATION AND PLACEMENT OF REINFORCING STEEL,MIXING, HANDLING, PLACING, FINISHING AND CURING OF CONCRETE SHALLBE IN ACCORDANCE WITH ACI-315 AND ACI-318.2. WIRE MESH REINFORCEMENT SHALL BE CENTERED IN SLAB, BY USEOF HIGH CHAIR WELDING WASHERS OR CONTINUOUS BEAM BOLSTERS.3. WELDED WIRE FABRIC AND WIRE SHALL BE LAPPED THE SPACING OFTHE CROSS WIRES PLUS 2".IV. STRUCTURAL STEEL:A.. DESIGN, FABRICATION, & ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCEWITH THE MANUAL OF STEEL CONSTRUCTION OF THE AMERICAN INSTITUTE OF STEELCONSTRUCTION NINTH EDITION UNLESS OTHERWISE MODIFIED ON THE DRAWINGS ORIN SPECIFICATIONS.B. MATERIAL SHALL MEET THE REQUIREMENTS OF THE FOLLOWING SPECIFICATIONUNLESS NOTED:STRUCTURAL STEEL- ASTM A992 (Fy=50 ksi)ROUND PIPE STEEL- ASTM A53 GRADE B (Fy=35ksi)TUBE STEEL- ASTM A500 GRADE B (Fy=46ksi)HIGH STRENGTH BOLTS- ASTM A325-86A, 3/4"ØWELD STEEL- AWS CLASS E70C. ALL SHOP CONNECTIONS SHALL BE WELDED OR MADE WITH HIGH STRENGTH BOLTSUNLESS NOTED SPECIFICALLY.D. FIELD CONNECTIONS SHALL BE MADE WITH 3/4" HIGH STRENGTH BOLTS. FIELD WELDINGWILL BE ALLOWED ONLY WHERE NOTED ON THE DRAWINGS AND DETAILS.E. ALL HIGH STRENGTH BOLTED CONNECTIONS SHALL BE BEARING TYPE WITH THREADSINCLUDED IN THE SHEAR PLANE UNLESS NOTED.F. ALL HIGH STRENGTH FIELD BOLTED CONNECTIONS SHALL BE TIGHTENED BY THE"TURN-OF-THE-NUT" METHOD AS SPECIFIED IN "THE ALLOWABLE STRESS DESIGNSPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS."G. FRAMED BEAM CONNECTIONS SHALL DEVELOP THE REACTION SHOWNON ENDS OF BEAMS ON STRUCTURAL PLANS. WHERE REACTIONS ARENOT SHOWN THE CONNECTION SHALL DEVELOP ONE-HALF THE ALLOWABLEUNIFORM LOAD FOR LATERALLY SUPPORTED BEAMS AS SHOWN INTABLES IN PART 2 OF THE AISC MANUAL. CONNECTION DESIGN TO BE SUBMITTEDBY ENGINEER LICENSED IN THE PROJECT STATE.H. ALL STRUCTURAL STEEL BELOW GRADE SHALL BE ENCASED WITHA MINIMUM OF 4" CONCRETE COVER OR PAINTED WITH A COAL TAR3. SEISMIC:a. RISK CATEGORY = II IMPORTANCE FACTOR = 1.00b. SITE CLASS = Dc. SS = 0.52 SDS= 0.48S I = 0.122 SDI = 0.192d. SEISMIC DESIGN CATEGORY = Ce. EQUIVALENT LATERAL FORCE PROCEDUREf. STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE R=3g. CS= 0.16h. DESIGN BASE SHEAR = 8.0 k4. SNOW:a. RISK CATEGORY = II IMPORTANCE FACTOR = 1.00b. Pg = 10 psf Pf = 7 psfc. Ce = 1.0 Ct= 1.0C. FOUNDATIONS:1. FOUNDATION DESIGN IS BASED ON SUBSURFACE EXPLORATION REPORTPREPARED BY: TERRACON2. IF, AFTER EXCAVATION, THE CONDITION OF THE SOIL INDICATES ASAFE BEARING CAPACITY OF LESS THAN 2000 p.s.f. THE ENGINEERSHALL BE NOTIFIED AND THE FOOTINGS REVISED IF NECESSARY.3. ALL GRADING AND FILLING SHALL BE DONE AS RECOMMENDED BYA GEOTECHNICAL ENGINEER. GENERAL CONTRACTOR SHALL ESTABLISHAND MAINTAIN SITE DRAINAGE TO DIRECT WATER AWAY FROMFOOTING EXCAVATIONS AND FILL PLACEMENT.4. ALL FOOTINGS SHALL BE POURED ON FIRM, UNDISTURBED EARTH ORENGINEERED CONTROLLED BACKFILL. BOTTOM OF EXTERIOR FOOTINGSSHALL BE A MINIMUM OF 18 INCHES BELOW FINISH GRADE UNLESSOTHERWISE NOTED, AND TOP OF FOOTING MUST COURSE WITH FINISH FLOOR.FROST LINE FOR THIS PROJECT IS 12 BELOW FINISH GRADE.2x4Fb1,500 psiFv175 psiFc1,650 psiFc565 psiE 1,600,000 psiMINIMUM WOOD PROPERTIESDIMENSIONAL LUMBER#2 SOUTHERN YELLOW PINE (SYP)2x62x82x10LAMINATED VENEER2x12LUMBER (LVL)1,250 psi1,200 psi1,050 psi975 psi2,925 psi175 psi175 psi175 psi175 psi285 psi1,600 psi1,550 psi1,500 psi1,450 psi1,600 psi565 psi565 psi565 psi565 psi750 psi1,600,000 psi1,600,000 psi 1,600,000 psi1,600,000 psi2,000,000 psiPARALLEL STRANDLUMBER (PSL)2,400 psi190 psi2,500 psi545 psi1,800,000 psiSCHEDULE NOTES:1. ALL COLUMNS TO BE CONTINUOUS U.N.O.COLUMN SCHEDULEMARKC1C2COLUMNBASEPLATEANCHORBOLTNOTESHSS6"x6"x1/4"3/4"x12"x1'-0"34" HEAVY HEX BOLTSEE SCHEDULEDWG. S0.1HSS10"x10"x1/4"3/4"x16"x1'-4"34" HEAVY HEX BOLTSEE SCHEDULEDWG. S0.1C3HSS4"x4"x1/4"3/4"x10"x0'-10"34" HEAVY HEX BOLTSEE SCHEDULEDWG. S0.1ANCHOR BOLT EMBEDMENTSSCHEDULEDIAMETER GRADE "P" "E"1/2"F1554 (36KSI)6"10"5/8"F1554 (36KSI)6"10"3/4"F1554 (36KSI)6"10"7/8"F1554 (36KSI)6"11"1"F1554 (36KSI)6"12"1 1/8"F1554 (36KSI)6"14"1 1/4"F1554 (36KSI)6"15"V. METAL STUDS:1. UNLESS NOTED OTHERWISE THE FOLLOWING SHALL APPLY2. MINIMUM YIELD STRENGTH FOR 20ga AND 18ga STUDS SHALL BE 33 ksiMINIMUM YIELD STRENGTH FOR 16ga, 14ga AND 12ga STUDS SHALL BE50 ksi - ALL TRACKS SHALL BE 33 ksi - WIND STRAPS ARE BASED ON THEUSE OF 40,000 psi FY MIN3. ALL STUDS, TRACK, BRIDGING AND ACCESSORIES SHALL BE FORMEDFROM STEEL HAVING A G-60 GALVANIZED COATING MEETING THEREQUIREMENTSOF A.S.T.M. A525.4. BOTH STUD FLANGES MUST BE FASTENED TO TRACK AT TOP AND BOTTOMAS SHOWN ON DRAWINGS.5. PANELS MUST BE FABRICATED WITH WELDS. WELDS SHALL BE PERFORMEDOPERATORS QUALIFIED IN ACCORDANCE WITH SECTION 6.0 OF THE AMERICANWELDING SOCIETY'S "STRUCTURAL WELDING CODE - SHEET METAL (AWS D1.3-8)6. ALL WELDS SHALL BE TOUCHED UP WITH ZINC RICH PAINT.7. STUDS SHALL HAVE FULL BEARING AGAINST INSIDE TRACK WEB PRIOR TOATTACHMENT AT BOTH ENDS - NO SPLICES, CUTS OR NOTCHES PERMITTEDAT LOAD BEARING STUDS.8. AT TRACK BUTT JOINTS, ABUTTING PIECES OF TRACK SHALL BE SECURELYANCHORED TO A COMMON STRUCTURAL ELEMENT, OR THEY SHALL BEBUTT-WELDED OR SPLICED TOGETHER9. A MINIMUM OF 10" OF UN-PUNCHED STEEL IS REQUIRED AT BOTH ENDS OF STUDS10. BRIDGING SHALL BE 1.5" CRC PLACED THROUGH PUNCH OUTS AND WELDEDON BOTH SIDES BRIDGING IS TO BE SPACED AT NO MORE THAN 3'-6" VERTICALLYAT APPROXIMATELY THE THIRD POINT - CRC BRIDGING IN 6" STUDS REQUIREA CLIP ANGLE AT EACH CONNECTION LOCATION11. USE THREE (3) STUDS AT THE CORNER OF ALL EXTERIOR WALLS USE THREE(3) STUDS AT THE INTERSECTION OF ALL LOAD BEARING WALLS (EXTERIORAND/OR INTERIOR)12. ALL MULTIPLE STUD GROUPS SHALL BE WELDED TOGETHER WITH 1" OFWELD @ 12"o.c. MAX ON BOTH FACES.13. TRACKS SHOWN @ BOTTOM OF DOOR OPENINGS ARE FOR EASE OF HANDLINGAND MAY BE REMOVED IN AREA OF DOOR AFTER PANEL IS ERECTED14. THE DRYWALL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADDING ANYMETAL STUDS, BLOCKING, OR FURRING THAT MAY BE NEEDED FOR DRYWALLATTACHMENT15. ALL STUD WALLS SHALL EXTEND TO BOTTOM OF STRUCTURE ABOVE.16. STUDS MUST BE INSTALLED UNDER ALL JOIST BEARING LOCATIONS.17. MINIMUM STRUCTURAL PROPERTIES LISTED IN THE LIGHT GAGE FRAMINGSCHEDULE SHALL APPLY. SEE SCHEDULE THIS SHEET.18. CONTRACTOR TO SUBMIT LIGHT GAUGE SHOP DRAWINGS STAMPED ANDSIGNED BY P.E. LICENSED IN STATE OF GEORGIA.VI. FASTENERS:EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE ON DRAWINGS:A. ALL POWDER ACTUATED FASTENERS (P.A.F.) TO BE .145" SHANK DIAMETERx 1 1/4" LONG HILTI X-DNI 32 P8 OR .177" SHANK DIAMETER x 1 1/4"LONG HILTI DS 37 P10, TYP. U.N.O.B. ALL EXPANSION ANCHORS TO BE HILTI KWIK BOLT II5/8"Ø - MIN. EMBED = 4"3/4"Ø - MIN. EMBED = 4 3/4"1"Ø - MIN. EMBED = 6"C. ALL SLEEVE ANCHORS TO BE HILTI CARBON STEEL SLEEVE ANCHORS.1/2"Ø - MIN. EMBED = 1 1/2"D. ALL EPOXY ANCHORS TO BE HILTI HIT HY200 ADHESIVE ANCHORS.5/8"Ø - MIN. EMBED = 5"3/4"Ø - MIN. EMBED = 6 5/8"7/8"Ø - MIN. EMBED = 7 1/2"1"Ø - MIN. EMBED = 8 1/4"E. ALL CONCRETE/MASONRY SCREWS TO BE HILTI KWIK-CON II+.3/16"Ø - MIN. EMBED = 1"1/4"Ø - MIN. EMBED = 1 3/4"F. ALL FASTENERS ARE SIZED PER HILTI SPECIFICATIONS. ALL FASTENERS MAYBE SUBSTITUTED BY AN EQUIVALENT THAT MUST BE SUBMITTED TO THEENGINEER FOR APPROVAL.VII. WOOD FRAMING NOTES1. WALL STUDS SHALL BE DOUBLED AT ALL ANGLES, CORNERS,AND AROUND ALL OPENINGS.2. REFER TO PLAN FOR ALL SHEAR WALL LOCATIONS.3. PROVIDE ALL BLOCKING AND FIRE STOPS REQUIRED BY THEBUILDING OFFICIAL.4. UNLESS OTHERWISE NOTED, ALL TIMBER CONNECTIONS SHALLBE NAILED IN CONFORMANCE WITH THE 1997 UNIFORM BUILDINGCODE.5. FLOOR SHEATHING SHALL BE DOUGLAS FIR-LARCH 3/4" TONGUE AND GROOVEPLYWOOD (C-D OR C-C) - NAILS SHALL BE 10d WITH MIN OF 1 1/2"PENETRATION IN FRAMING - PLYWOOD SHALL BE BLOCKED WITH CONTINUOUSPANEL NAIL SPACING OF 4" (UNO) ALONG BEARING WALLS, SHEAR WALLS ANDCORRIDORS - NAIL SPACING AT OTHER PANEL EDGES SHALL BE 6" (UNO)6. ROOF SHEATHING SHALL BE DOUGLAS FIR-LARCH 5/8" PLYWOOD (C-D OR C-C)NAILS SHALL BE 8d WITH MIN OF 1 1/2" PENETRATION IN FRAMINGNAILS SHALL BE SPACED @ 6"o/c AT SUPPORTED EDGESEORG I REGISTEREDNO ERO ESSIONA10 2 EESNG IBRNEEI ANRHO25JOB NO.2320DATE 2 OCTOBER 25DRAWN BYJ.C.REVISIONSLEGENDSECTION CUTNUMBER ORDETAIL LETTERDRAWING TITLESTRUCTURALNOTESDENOTES DRAWINGWHERE SECTION ORDETAIL IS CUT.DENOTES DRAWINGWHERE SECTION ORDETAIL IS SHOWN.March 310 Dodds Ave.P.O. Box 3689Adams& Chattanooga, Tennessee 37404Associates PH: (423)698-6675Consulting Engineers MAA JN: 24133SHEET NO.S0.1VIII. SPECIAL INSPECTIONS:THE FOLLOWING SPECIAL INSPECTIONS SHALL BE PERFORMED PER CHAPTER 17OF THE 2018 INTERNATIONAL BUILDING CODE:GENERAL NOTES:1. INSPECTION OF FABRICATORS: SPECIAL INSPECTOR IS TO VERIFY THAT FABRICATORS MAINTAIN DETAILED FABRICATION AND QUALITYCONTROL PROCEDURES THAT PROVIDE A BASIS FOR INSPECTION CONTROL OF THE WORKMANSHIP AND THE FABRICATOR'S ABILITYTO CONFORM TO THE APPROVED CONSTRUCTION DOCUMENTS AND REFERENCED STANDARDS. SEE 1704.2.5.1.2. REFERENCE CURRENT STATE BUILDING CODE FOR APPLICABLE REFERENCED STANDARD SPECIFIC EDITION INFORMATION.3. CONTRACTOR RESPONSIBILITY:a. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND- OR SEISMIC-FORCE-RESISTING SYSTEM,DESIGNATED SEISMIC SYSTEM OR A WIND- OR SEISMIC-RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIALINSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TOTHE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALLCONTAIN ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS.IBC 2018 SECTION 1705.2REQUIRED SPECIAL INSPECTIONS AND TESTS OF STEEL CONSTRUCTION1. SPECIAL INSPECTION FOR STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE QUALITY CONTROL AND QUALITY ASSURANCEREQUIREMENTS OF THE LATEST EDITIONS OF AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AND THE COMMENTARY OFAISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS.2. SPECIAL INSPECTIONS AND QUALIFICATION OF WELDING SPECIAL INSPECTORS FOR COLD-FORMED STEEL FLOOR AND ROOF DECK SHALLBE IN ACCORDANCE WITH THE QUALITY ASSURANCE INSPECTION REQUIREMENTS OF SDI QA/QC.IBC 2018 TABLE 1705.3REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTIONVERIFICATION AND INSPECTION1. INSPECTION OF REINFORCING STEEL, INCLUDINGPRESTRESING TENDONS, AND PLACEMENT.2. REINFORCING BAR WELDING:a. VERIFY WELDABILITY OF REINFORCING BARSOTHER THAN ASTM A-706b. INSPECT SINGLE PASS FILLET WELDS, MAXIMUM 156"c. INSPECT ALL OTHER WELDS3. INSPECT ANCHORS CAST IN CONCRETE.4. INSPECT ANCHORS POST-INSTALLED IN HARDENEDCONCRETE MEMBERS.a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY ORUPWARDLY INCLINED ORIENTATIONS TO RESISTSUSTAINED TENSION LOADS.b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOTDEFINED IN 4.A.5. VERIFY USE OF REQUIRED DESIGN MIX.6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENSFOR STRENGTH TESTS, PERFORM SLUMP AND AIRCONTENT TESTS, AND DETERMINE THE TEMPERATURE OFTHE CONCRETE.7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FORPROPER APPLICATION TECHNIQUESCONTINUOUS---X-PERIODICXX-XREFERENCEDSTANDARDACI 318 Ch. 20, 25.2,25.3, 26.6.1-26.6.3AWS D1.4ACI 318: 26.6.4ACI 318: 17.8.2X-ACI 318: 17.8.2.4-XACI 318: 17.8.2-XACI 318: Ch. 19,26.4.3, 26.4.4ASTM C 172X-ASTM C 31ACI 318: 26.5, 26.12X-ACI 318: 26.58. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATUREAND TECHNIQUES-XACI 318: 26.5.3-26.5.59. INSPECT PRESTRESSED CONCRETE FOR:a. APPLICATION OF PRESTRESSING FORCES; ANDb. GROUTING OF BONDED PRESTRESSING TENDONS.10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS.11. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TOSTRESSING OF TENDONS IN POST-TENSIONED CONCRETEAND PRIOR TO REMOVAL OF SHORES AND FORMS FROMBEAMS AND STRUCTURAL SLABS.12. INSPECT FORMWORK FOR SHAPE, LOCATION ANDDIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.X-ACI 318: 26.10X--XACI 318: Ch. 26.9-XACI 318: 26.11.2-XACI 318: 26.11.1.2(b)IBC REFERENCE1908.4---1904.1, 1904.2,1908.2, 1908.31908.101908.6, 1908.71908.81908.9IBC 2018 TABLE 1705.6REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILSVERIFICATION AND INSPECTION1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS AREADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.CONTINUOUSLY DURINGTASK LISTED-2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTHAND HAVE REACHED PROPER MATERIAL.-3. PERFORM CLASSIFICATION AND TESTING OF COMPACTEDFILL MATERIALS.-4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFTTHICKNESSES DURING PLACEMENT AND COMPACTION OFXCOMPACTED FILL.5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVESUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED-PROPERLY.PERIODICALLY DURINGTASK LISTEDXXX-XEORG I REGISTEREDNO ERO ESSIONA10 2 EESNG IBRNEEI ANRHO25JOB NO.2320DATE 2 OCTOBER 25DRAWN BYJ.C.REVISIONSDRAWING TITLESTRUCTURALNOTESMarch 310 Dodds Ave.P.O. Box 3689Adams& Chattanooga, Tennessee 37404Associates PH: (423)698-6675Consulting Engineers MAA JN: 24133SHEET NO.S0.212'-2"11'-2"28'-3"23'-4"6'-10"38'-3"DL -9.6kLL -6.4kRLL -1.9kWLX ±0.789k, ±0.3kYWLY 1.4kWLZ ±0.762k, ±0.2kYELX ±4.0k, ±0.3kYELZ ±4.0k, ±0.4kYDL -9.2kLL -6.0k6RLL -1.9kS2.0WLX ±0.789k, ±0.3kYWLY 1.4kWLZ ±0.762k, ±0.3kYELX ±4.0k, ±0.3kYELZ ±4.0k, ±0.4kY12'-1183"1S1.041'-0"CAAAAAA4A(C1)(-0'-10")(C1)GB-3(-0'-10")GB-3(C3)(-0'-10")GB-3 (C3)(-0'-10")(C1)GB-3(-0'-10")(C1)GB-3(-0'-10")S2.0DL -16.5k21" EXP. JOINTLL -7.7kRLL -3.1kWLX ±0.789k, ±0.6kYWLY 1.5kWLZ ±0.762k, ±2.6kYELX ±4.0k, ±0.5kYELZ ±4.0k, ±1.7kYDL -20.2kLL -13.9k2.32.7RLL -2.4kWLX ±0.789k, ±0.2kYWLY 1.8kWLZ ±0.762k, ±0.9kYELX ±4.0k, ±0.1kYELZ ±4.0k, ±0.0kYDL -21.1kLL -14.6kRLL -2.6kWLX ±0.789k, ±0.3kYWLY 1.9kWLZ ±0.762k, ±0.2kYELX ±4.0k, ±0.2kYELZ ±4.0k, ±0.0kYDL -14.9kRLL -1.3kLL -3.1kWLX ±0.789k, ±1.0kYWLY 2.3kWLZ ±0.762k, ±1.2kYELX ±4.0k, ±0.7kYELZ ±4.0k, ±0.7kY5S2.0PILE CAP (TYP.)4BSIZE TBD AFTER HELICAL DESIGNS2.0CGB-2GB-1GB-2DL -20.0kLL -15.5k(C1)(-0'-10")(C2)B(-0'-10")(C2)B(-0'-10")RLL -2.6kBA (C1)(-0'-10")WLX ±0.789k, ±0.4kYWLY 2.0kDL -21.0kTEMPORARILY SHORE LL -16.6kEXISTING FOUNDATION RLL -2.3kBY CONTRACTOR'SWLX ±0.789k, ±1.3kYSHORING ENGINEER WLY 1.7kWLZ ±0.762k, ±0.0kYELX ±4.0k, ±0.9kY1ELZ ±4.0k, ±0.0kYS2.1DL -72.9kLL -50.7kRLL -10.1kWLX ±0.789k, ±0.6kYWLY 6.8kWLZ ±0.92k, ±1.7kY#5 @ 8"T&B#4 @ 12"T&BDL -68.3kLL -51.4k6RLL -8.5kS2.0WLX ±0.789k, ±0.9kYWLY 6.8kWLZ ±0.762k, ±1.0kYWLZ ±0.762k, ±0.3kYELX ±4.0k, ±0.0kYELZ ±4.0k, ±0.2kYDL -7.1kEXISTING FOOTINGELX ±2.0k, ±0.5kYELX ±4.0k, ±1.0kYLL -3.7kELEVATION (-) 6'-4"ELZ ±2.0k, ±0.6kYELZ ±4.0k, ±1.1kYB.3(C3)(-0'-10")RLL -1.9kWLX ±0.789k, ±0.7kYWLY 1.4k3'-1131"6S3.0 21 S3.0AWLZ ±0.762k, ±0.3kYELX ±4.0k, ±0.4kYELZ ±4.0k, ±0.3kY3'-6 16315'-4"(C1)(-0'-10")B.710" CONC. SLAB ON 10 MIL VAPOR RETARDERON 6" WASHED STONE FILLDL -73.9kLL -51.2kRLL -9.7kWLX ±0.789k, ±1.8kYB.7(C3)(-0'-10")ADL -7.4kLL -4.0kRLL -1.9kWLX ±0.789k, ±0.6kYWLY 1.4kWLZ ±0.762k, ±0.3kYWLY 6.5kELX ±4.0k, ±0.4kYDL -18.3kLL -15.1kRLL -1.2kWLX ±0.789k, ±0.2kYWLY 1.3kWLZ ±0.762k, ±0.2kY(C1)(-12'-0")1'-6"FD30'-9"1'-6"GB-1WLZ ±0.762k, ±1.1kYELX ±4.0k, ±0.5kYELZ ±4.0k, ±0.5kYGB-2ELZ ±4.0k, ±0.3kYDL -19.8kLL -15.1kELX ±4.0k, ±0.1kYELZ ±4.0k, ±0.2kY12" CONCRETE RETAINING WALL 12'-0" TALL. (TYP.)ON 10'-0"x16"xCONT. WALL FOOTING w/ (2) HELICAL PILES@ 4'-0" O.C. LOADS FOR EA. HELICAL ARE AS FOLLOWS:DL -40.0kLL -2.0kDL -11.6k(C1)(-0'-10")(C2)(-0'-10")(C1)(-0'-10")15'-1561"DL -69.4kLL -50.5kRLL -8.0kWLX ±0.789k, ±0.6kYWLY 6.0kWLZ ±0.762k, ±1.3kY(C2)B(-0'-10")RLL -2.4kC(C1)WLX ±0.789k, ±0.7kY(-0'-10")WLY 1.8kAWLZ ±0.762k, ±0.2kYELX ±4.0k, ±0.1kYELZ ±4.0k, ±0.2kYPILE CAP (TYP.)LL -8.0kELX ±4.0k, ±0.5kYRLL -1.4kWLX ±0.789k, ±1.5kYELZ ±4.0k, ±0.9kY2.2(C1)(-0'-10")WLY 0.7kWLZ ±0.762k, ±0.1kYELX ±4.0k, ±1.0kYDL -20.8kLL -15.1kCGB-4DL -36.1kLL -24.3kGB-4(C1)(-0'-10")DL -15.0kLL -5.9kELZ ±4.0k, ±1.0kY(C1)RLL -1.9kRLL -2.4kRLL -3.2kD(-0'-10")WLX ±0.789k, ±0.2kYWLX ±0.789k, ±0.2kYWLX ±0.789k, ±2.8kYWLY 1.4kCWLZ ±0.762k, ±0.7kYWLY 1.8kWLZ ±0.762k, ±1.9kYCWLY 1.5kWLZ ±0.762k, ±0.8kYELX ±4.0k, ±0.1kYELX ±4.0k, ±0.1kYELX ±4.0k, ±1.7kYELZ ±4.0k, ±0.4kYELZ ±4.0k, ±1.0kYELZ ±4.0k, ±0.5kY-12'-8"16'-721"12'-11176"LEGENDDL - DEAD LOADLL - LIVE LOADRLL - ROOF LIVE LOADWLX - WIND LOAD X-DIRECTIONWLY - WIND LOAD Y-DIRECTIONWLZ - WIND LOAD Z-DIRECTIONSL - SNOW LOAD+Y (UP)+X+ZNOTE: SNOW LOAD REACTIONS ARE EQUALTO12EACHRLLREACTIONALL REACTIONS ARE UNFACTOREDSTRUCTURAL NOTES:1. ALL PILE CAPS SHALL BE CENTERED UNDER COLUMNSAND BEAM BEARING WALL REINFORCEMENTS U.N.O.2. SEE SHEET S2.1 FOR ADDITIONAL SECTIONSAND DETAILS3. ALL SECTIONS TYP U.N.O.STRUCTURAL LEGEND:(?)COLUMN DESIGNATION - SEECOLUMN SCHEDULE THIS SHEETEORG I REGISTEREDNO ERO ESSIONA10 2 EESNG IBRNEEI ANRHO25SCHEDULE NOTES:1. ALL COLUMNS TO BE CONTINUOUS U.N.O.COLUMN SCHEDULEMARKC1C2COLUMNBASEPLATEANCHORBOLTNOTESHSS6"x6"x1/4"3/4"x12"x1'-0"34" HEAVY HEX BOLTSEE SCHEDULEDWG. S0.1HSS10"x10"x1/4"3/4"x16"x1'-4"34" HEAVY HEX BOLTSEE SCHEDULEDWG. S0.1C3HSS4"x4"x1/4"3/4"x10"x0'-10"34" HEAVY HEX BOLTSEE SCHEDULEDWG. S0.1MARKABCPILE CAP TYPESCAPACITYNO. OF PILES40 TON350 TON440 TON3MAX. LOAD-k-k-kDETAIL1/ S2.02/ S2.03/ S2.0, 4/ S2.0GRADE BEAM SCHEDULEMARKGB-1GB-2GB-3BEAM SIZE (W x D)REINFORCEMENTNOTES14W x 22D(3) #8 T & B#4 STIRRUPS @ 9" O.C.3" CLEAR COVER BOTTOM34" CLEAR COVER TOP14W x 22D(4) #6 TOP(2) #6 BOTTOM#4 STIRRUPS @ 9" O.C.3" CLEAR COVER BOTTOM34" CLEAR COVER TOP12W x 22D(2) #6 T & B#4 STIRRUPS @ 9" O.C.3" CLEAR COVER BOTTOM34" CLEAR COVER TOPGB-414W x 30D(3) #7 T & B#4 STIRRUPS @ 12" O.C.3" CLEAR COVER BOTTOM34" CLEAR COVER TOPJOB NO.2320DATE 2 OCTOBER 25DRAWN BYJ.C.REVISIONSNORTH1 FOUNDATION PLANS1.0 SCALE: 1/4"=1'-0"#4 @ 12" T & B#5 @ 8" T & BFINISHED FLOOR ELEVATION10" CONCRETE SLAB6" CRUSHED STONE FILL1 SECTIONS1.0 SCALE: 1/2"=1'-0"TYP. SLAB CONSTRUCTIONGRADE BEAM, DEPTH VARIES, SEE SCHEDULEDRAWING TITLEFOUNDATIONPLANMarch 310 Dodds Ave.P.O. Box 3689Adams& Chattanooga, Tennessee 37404Associates PH: (423)698-6675Consulting Engineers MAA JN: 24133SHEET NO.S1.0"w"1'-0" CLAYCAP#5 @ 12" o.c.FOR 10" - 12"THICK WALLSWRAP STONE BACKFILL INGEOTEXTILE FABRICCONC.V-BARS"a"221"2WASHED STONE BACKFILL13" DIAMETER WEEP HOLESw/ SCREENS @ 6'-0" o.c.#5 @ 12"o.c.#5 @ 12"o.c.3"TYP3"X-BARS(1) #5"c""d"SITE RETAINING WALL SCHEDULE"H"ft.-in.2'-0"4'-0"6'-0"8'-0"10'-0""w" "a" "b" "c"inft.-in. ft.-in. ft.-in.12"1'-0" ----------12"1'-0" ----------12"1'-0"----------12"1'-0"----------12"1'-6"----------"d"ft.-in.3'-0"3'-0"5'-6"7'-6"9'-0""t" V-BARSin12" #5 @ 12"o.c.12" #5 @ 12"o.c.12" #5 @ 12"o.c.16" #5 @ 12"o.c.16" #6 @ 12"o.c.NOTE:1) PROVIDE EXPANSION JOINTS IN WALL AT 24'-0" ONCENTER.2) MINIMUM BAR LAP IS 40 DIAMETERSSECTIONNTSSEE SECTION 2/ S1.0AFOR RETAINING WALL2S1.0A S1.0A121"MIN.X-BARS#5 @ 12"o.c.#5 @ 12"o.c.#5 @ 12"o.c.#6 @ 12"o.c.#6 @ 12"o.c.NOTE:SEE ARCH. DWGS. FORBRICK & PIER FINISHT/ PIEREL. 800.00'1'-2"PIERPLAN(8) #5's#4 TIES @ 12" O.C.APAVILIONFINISH FLOOREL. 796.00'T/ RETAINING WALLSEE ARCH. DWGS. FORBRICK & PRECAST FINISHEL. 795.00'PIER(8) #5's#4 TIES @ 12" O.C.EXTEND FOOTING TO 1'-6"AROUND LIGHT POLE PIERSSEE DWG. E1.0 FOR LIGHTPOLE LOCATIONS1'-6"107842" RCP25'-0"SSMHTOP= 791.0OUT 768.85IN= 769RETAINING WALL9S1.0B10'-0S"WMHBSRIGICNKTOP=782.6OUT 768.5IN= 773.5IN= 768.615'-2"19'-7"TOW-2"-2 1/2"-2 1/2"-4 1/2"5'-1"3'-1"8T-O2"WS1.0B-2" 7-19" 4.67STORYHOUR221LIGHT POLE (TYP.)5S1.0B19'-0"4S1.0B12'-0"1'-8"-4"-4"LIGHT POLE (TYP.)19'-0"-2 1/2"-4"RETAINING WALLTOW-2"9'-5"28'-1"9'-5"-4 1/2"APPROX. LOCATION WATER LINES-1/2"CLOSETCHILDREN'SREADING219WAUGH STRE8"ESTAN8S4E'WRE/RWLINEEXISTING SIDEWALKWAUGH STREET 84' R/W9'-5"-2 1/2"-1/2"TOW-2"9'-6"19'-0"9'-6"-3 1/2"-2 1/2"6'-10"11'-5"4'-9"11'-8"-2"2-2 1/2"9'-6"19'-0"-3 1/2"ADJUSTED9'-6"FRONT3YARD9'-6"SETBACK-BY19'-0"VARI4ANC9'E-6"7'-7"-2"-3 1/2"T-O2"W9'-7"19'-3"9'-7"1/2"1/2"-1"9'-6"19'-0"-2 1A /2"RETAINING WALL2.32.75'-8"9'-3"-2 1/29'-6"-2'-0"-1'-10"10S1.0BDNCHILDREN'SREADING222T-O2"W7'-8"-2'-3"PROJECTIONROOM234-2'-0"UP STORAGE233MULTI-PURPOSEROOM232CHILDREN'SCIRC. DESK223CHILDREN'SWORKROOM224FFE = 796.00'CHILDREN'SREFERENCE220KITCH.229MULTI-PURPOSECORRIDOR225EXIST. RAMP DN1:12DNSTAIR1091:12CHILDREN'SCOLLECTIONS217B.7STOR.216AMEN216CO21R3RIDORVEST.214STOR.281PAVILION282FFE = 796.00'KITCHEN2802.2CLOSET280AWOMEN215STOR.212ASTOR.215A-1/2"-3 1/2B5'-3"-4-2 1/2"T-O2"W-2"-2"-4R23'-6"B.3-3 1/2-2 1/2-1/2 0"2'-4"8'-0"-2 1/4"6S1.0BB.7-2" 5'1-7/6"" /ft-2 1/2"-2"-4T-O2"W-2"-4"12'-0"101'-/54"" / ft12'-8"C1'-8" 5'-8"7'-11"-3 1/2"8'-7"+ - 2"-2 1/2"-3 1/2-1 3/4"163'/-166"" /ftWATER VALVE- 2"1-1/2"D-1/2"- 1"-2"S1.0BC.C. FLUMEGENERALREADING214SPECIALCOLLECTION2111'-11"11"1'-0"1'-2"9"PIERNORTH1 RETAINING WALL PLANS1.0A SCALE: 3/32"=1'-0"BUILDING FINISH FLOOR ELEVATION = 796.00TOW = TOP OF PRECAST COPING AT -2", EL. 795.83TOP OF RETAINING WALL AT -1-0", EL. 795.00TOP OF PIERS AT +4'-0", EL. 800.00NOTE:REFER TO ARCHITECTURAL DRAWINGS FORLIGHT POLE LOCATIONSRETAINING WALLSEE DETAIL 2/ S1.0ARETAINING WALL FTG.SEE DETAIL 2/ S1.0AEORG I REGISTEREDNO ERO ESSIONA10 2 EESNG IBRNEEI ANRHO25JOB NO.2320DATE 2 OCTOBER 25DRAWN BYJ.C.REVISIONSDRAWING TITLERETAININGWALL PLANA3 RETAINING WALL PIERS1.0A SCALE: 3/4"=1'-0"SECTION ~ AAMarch 310 Dodds Ave.P.O. Box 3689Adams& Chattanooga, Tennessee 37404Associates PH: (423)698-6675Consulting Engineers MAA JN: 24133SHEET NO.S1.0ASEE ARCH DWGS FORFINISH DETAILSFFE 796.001'-0"8" 4"GRADE 795.00T/ WALL 794.95SEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILS1 RETAINING WALL SECTIONS1.0B SCALE: 3/4"=1'-0"SEE ARCH DWGS FORFINISH DETAILSFFE 796.00T/ WALL 794.951'-0"8" 4"GRADE 790.00SEE ARCH DWGS FORFINISH DETAILSFFE 796.001'-0"8" 4"T/ WALL 794.95GRADE 794.00SEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILS2 RETAINING WALL SECTIONS1.0B SCALE: 3/4"=1'-0"T/ PIER 800.001'-2"9"PIERSEE DETAIL FOR 3REINFORCING S1.0AGRADE 795.007S1.0BFFE 796.00SEE ARCH DWGS FORFINISH DETAILST/ WALL 794.951'-0"8" 4"SEE ARCH DWGS FORFINISH DETAILSFFE 796.001'-0"8" 4"T/ WALL 794.95GRADE 793.00SEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILS3 RETAINING WALL SECTIONS1.0B SCALE: 3/4"=1'-0"T/ PIER 800.001'-2"9"PIERSEE DETAIL FOR 3REINFORCING S1.0A7S1.0BFFE 796.00T/ WALL 794.95SEE ARCH DWGS FORFINISH DETAILS1'-0"8" 4"GRADE 790.00EXTEND FOOTING TO 1'-6"AROUND LIGHT POLE PIERSSEE DWG. E1.0 FOR LIGHTPOLE LOCATIONS1'-6"11"SEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILS4 RETAINING WALL PIER SECTIONS1.0B SCALE: 3/4"=1'-0"EORG I REGISTEREDNO ERO ESSIONA10 2 EESNG IBRNEEI ANRHO25SEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILS5 RETAINING WALL SECTIONS1.0B SCALE: 3/4"=1'-0"SEE ARCH. DWGS. FOR GUARDRAIL121"#5's x CONT.T/ WALL EL. 795.66'±MATCH EXIST. SLAB1'-121"1'-0"BACKFILL AND POUR NEW SLAB TOMATCH EXISTING AFTER RETAININGWALL INSTALLATION#4's @ 12" O.C.EXIST. SLABEL. VARIESXXXXXT/ WALLEL. 795.00'#5's @ 12" O.C. EACH WAYT/ RAMPEL. VARIES (SEE PLAN)794.00' - 795.83'SIZE SLAB(SEE CIVIL DWGS.)#5's @ 12" O.C.T/ FTG.EL. 793.00'1'-2"8"1'-2"3'-0"10 RETAINING WALL SECTIONS1.0B SCALE: 3/4"=1'-0"EXTEND FOOTING TO 1'-6"AROUND LIGHT POLE PIERSSEE DWG. E1.0 FOR LIGHTPOLE LOCATIONS1'-6"11"SEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILS6 RETAINING WALL PIER SECTIONS1.0B SCALE: 3/4"=1'-0"EDGE OF TURNDOWN SLABEXTEND FOOTING TO 1'-6"AROUND LIGHT POLE PIERSSEE DWG. E1.0 FOR LIGHTPOLE LOCATIONSRETAINING WALLPIER1'-2"9"8" 4"1'-6"11"1'-0"WALL7 PIER PLANS1.0B SCALE: 3/4"=1'-0"SEE ARCH DWGS FORFINISH DETAILSFFE 796.001'-0"8" 4"T/ WALL 794.95GRADE 793.00T/ RAMP 795.83SEE ARCH DWGS FORFINISH DETAILSFFE 796.001'-0"8" 4"T/ RAMP 794.00GRADE 793.00T/ WALL 794.95RAMP DOWN FROM 795'-10" TO 794'-0"RETAINING WALL TO FOLLOW SLOPE OF RAMPSEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILSSEE SCHEDULE ON S1.0A FORRETAINING WALL DETAILSJOB NO.2320DATE 2 OCTOBER 25DRAWN BYJ.C.REVISIONS8 RETAINING WALL SECTION @ TOP OF RAMPS1.0B SCALE: 3/4"=1'-0"9 RETAINING WALL SECTION @ BOTTOM OF RAMPS1.0B SCALE: 3/4"=1'-0"March 310 Dodds Ave.P.O. Box 3689Adams& Chattanooga, Tennessee 37404Associates PH: (423)698-6675Consulting Engineers MAA JN: 24133DRAWING TITLERETAININGWALLSECTIONSSHEET NO.S1.0B
- Commodity Codes
-
- NAICS 541330Engineering Services
* Disclaimer: Government BidHub provides information on bids, RFPs (Requests for Proposals), and RFQs (Requests for Qualifications) solely for convenience and informational purposes. This site is not an official public notice board. For official details, responses, or inquiries, please contact the relevant government agency directly.
Empower Your Bidding Strategy
Unlock Government BidHub's unparalleled access to high-quality, tailored bid information.
- Access an extensive database of bids, including comprehensive local and state opportunities.
- Receive customized alerts for the bids that matter most to your business.
- Explore detailed specifications to ensure precise and competitive submissions.
- Gain a competitive edge with up-to-date information and exclusive opportunities.
See Also
ITB #26-97 Riverdale Library ...
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-63100-NONST-2026-000000097
State Government of Georgia
Bid Due: 7/30/2026